Manual Book ParadiseBUC
Manual Book ParadiseBUC
➤ Quick-Start (216595-2)
                                                                                        1 of 1
THIS PAGE LEFT INTENTIONALLY BLANK
Outdoor SSPAs, General Information (216595-1)
                                                                                1 of 10
Outdoor SSPAs, General Information (216595-1)
              This section provides the general information for the Teledyne Paradise Datacom Outdoor Solid State Power Amplifier
              (SSPA) family of products, including the Compact Outdoor SSPA and High Power Outdoor SSPA.
                                                                     2 of 10
Outdoor SSPAs, General Information (216595-1)
              Refer to the SSPA's specification sheet for complete specifications. The latest revision of the specification sheets for the
              Compact Outdoor SSPA and High Power Outdoor SSPA are available on the Teledyne Paradise Datacom web site:
              www.paradisedata.com.
                                                                         3 of 10
Outdoor SSPAs, General Information (216595-1)
              When the unit is received, an initial inspection should be completed. First ensure that the shipping container is not damaged.
              If it is, have a representative from the shipping company present when the container is opened. Perform a visual inspection
              of the equipment to make sure that all items on the packing list are enclosed. If any damage has occurred or if items are
              missing, contact:
                                                                       4 of 10
Outdoor SSPAs, General Information (216595-1)
              To protect the SSPA Chassis during shipment, use high quality commercial packing methods. When possible, use the
              original shipping container and its materials. Reliable commercial packing and shipping companies have facilities and
              materials to adequately repack the instrument.
                                                                      5 of 10
Outdoor SSPAs, General Information (216595-1)
              Potential safety hazards exist unless proper precautions are observed when working with this unit. To ensure safe operation,
              the user must follow the information, cautions and warnings provided in this manual as well as the warning labels placed on
              the unit itself.
                      All probes and tools that contact the equipment should be properly insulated to prevent the operator
                    from coming in contact with the voltage.
The work area should be secure and free from nonessential items.
                      Operators should never work alone on high voltage devices. There should always be another person
                    present in the same work area to assist in the event of an emergency.
                     Operators should be familiar with procedures to employ in the event of an emergency, i.e., remove all
                    power, CPR, etc.
                      An AC powered unit will have 115 VAC or 230 VAC entering through the AC power connector. Caution is
                    required when working near this connector, the AC circuit breaker, or the internal power supply.
                      Operators should never work alone on high risk devices. There should always be another person present
                    in the same area to assist in the event of an emergency.
                                                                      6 of 10
Outdoor SSPAs, General Information (216595-1)
                     Operators should be familiar with procedures to employ in the event of an emergency, i.e., remove all
                    power, CPR, etc.
              Large DC currents are generated to operate the RF Module inside of the enclosure. Extreme caution is required when the
              enclosure is open and the amplifier is operating. Do not touch any of the connections on the RF modules when the amplifier
              is operating. Current in excess of 60 Amperes may exist on any one connector.
              RF Transmission Hazards
              RF transmissions at high power levels may cause eyesight damage and skin burns. Prolonged exposure to high levels of RF
              energy has been linked to a variety of health issues. Please use the following precautions with high levels of RF power.
Always terminate the RF input and output connector prior to applying prime AC input power.
                      Maintain a suitable distance from the source of the transmission such that the power density is below
                    recommended guidelines in ANSI/IEEE C95.1. The power density specified in ANSI/IEEE C95.1-1992 is 10
                    mW/cm2. These requirements adhere to OSHA Standard 1910.97.
                     When a safe distance is not practical, RF shielding should be used to achieve the recommended power
                    density levels.
                      All probes and tools that contact the equipment should be properly insulated to prevent electrical
                    discharge.
The work area should be secure and free from nonessential items.
                      Operators should never work alone on hazardous equipment. There should always be another person
                    present in the same work area to assist in the event of an emergency.
                                                                       7 of 10
Outdoor SSPAs, General Information (216595-1)
                      Operators should be familiar with procedures to employ in the event of an emergency, i.e., remove all
                     power, CPR, etc.
                                                                         8 of 10
Outdoor SSPAs, General Information (216595-1)
              When working with high power amplifier systems that operate into waveguide, the inadvertent creation of arcs is always a
              concern. An arc in waveguide is the air discharge breakdown due to the ionization of the air molecules by electrons. This
              breakdown in waveguide occurs when the rate of electron production becomes greater than the loss of electrons to diffusion
              to the surrounding walls.
              It is extremely difficult to precisely predict the power levels at which the breakdown occurs. It is dependent on a variety of
              factors but the primary factors are:
              When operating such a high power amplifier system it is imperative that the waveguide transmission system be dehydrated
              and pressurized. Operation with an automatic air dehydrator will provide dry pressurized air to ensure that condensation
              cannot form in the waveguide. Also the higher the pressure that can be maintained in the waveguide; the higher the power
              handling is in the waveguide system. Most commonly available air dehydrators are capable of providing pressures of 0.5 to
              7.0 psig (25-362 mmHg).
              At low power levels (uniform field distribution), low pressure can give good results. For non-uniform conditions, highly
              localized breakdown can occur. In this case the waveguide system will require much higher pressure. This occurs with
              bends, waveguide flange joints. If line currents flow across a small gap introduced by poor tolerances, flange mismatch,
              poorly soldered bends, field strengths in excess of that in the main line can occur in the gap. Pressurization with air or high
              dielectric gases can increase the power handling by factors of 10 to 100.
              In High Power Amplifier systems an arc will travel from where it is ignited back to the amplifier. Typical arc travel speed is on
              the order of 20 ft/sec. Increasing the waveguide pressure can reduce the speed of arc travel. It is difficult to get an accurate
              calculation of the amount of pressurization needed, but it is a good practice to get as much pressure as your system can
              handle. All high power systems that meet the criteria of Table 1 are pressure tested at the factory to 1.5 psig.
                      Important! As a guide we recommend using the power levels in Table 1 as the threshold levels where
                     special attention be given to dehydration and the overall simplification of waveguide system design.
              It is a common misconception to look up the maximum theoretical power handling of a particular type of waveguide and
              assume that this is the maximum power handling. This may be the case for a straight waveguide tube with ideal terminations
              but these values must be significantly de-rated in practical systems. Phase combined amplifier systems can be particularly
              sensitive to the potential for waveguide arcing. This is due to the numerous bends, magic tees, multiple waveguide flange
              joints, and other waveguide components. Table 2 shows the power handling capability of some popular waveguide
              components normalized to the waveguide power rating. From this table, we can see how a practical waveguide system's
              power handling will de-rate significantly.
                                                                         9 of 10
Outdoor SSPAs, General Information (216595-1)
              Most waveguide systems have many of these components integrated before reaching the antenna feed. It is not uncommon
              for a Satcom waveguide network to de-rate to 5% of the straight waveguide power rating.
              The load VSWR also has an impact on the breakdown threshold in waveguide networks. Standing waves degrade the power
              handling of any transmission line network. The graph of Figure 4 shows the rapid degradation of waveguide breakdown vs.
              load VSWR. The chart shows that for a 2.0:1 load VSWR, the breakdown potential will be half of what it would be with a
              perfectly matched load. This can degrade even more when high Q elements such as band pass filters are included in the
              waveguide network.
              There are many factors to consider with high power amplifier systems in terms of the output waveguide network. Especially
              when using HPA systems with output power levels of Table 2, it is imperative to ensure that the output waveguide network is
              pristinely clean and dry. An appropriate dehydrator should be used with capability of achieving adequate pressure for the
              system's output power. Take extra precaution to make sure that any waveguide flange joints that are not already in place at
              the factory are properly cleaned, gasket fitted, and aligned. A properly designed and maintained waveguide network will
              ensure that no arcing can be supported and will provide many years of amplifier service life.
                                                                                   10 of 10
Unit Description, Compact Outdoor SSPA (208495-1)
                                                                                1 of 13
Unit Description, Compact Outdoor SSPA (208495-1)
              This section provides information for the initial inspection, installation, external connections, and shipment of the Compact
              Outdoor SSPA unit.
                                                                        2 of 13
Unit Description, Compact Outdoor SSPA (208495-1)
              When the unit is received, an initial inspection should be completed. Ensure that the shipping container is not damaged. If it
              is, have a representative from the shipping company present when the container is opened. Perform a visual inspection of
              the Compact Outdoor Amplifier to make sure that all items on the packing list are enclosed. If any damage has occurred or if
              items are missing, contact:
                                                                       3 of 13
Unit Description, Compact Outdoor SSPA (208495-1)
              The following section details the connector pin-outs for the Compact Outdoor SSPA. Figure 1 shows a typical example of the
              overall dimensioned outline of a C-Band GaN Compact Outdoor Amplifier. Dimensions to the RF output flange may vary
              based on unit options. Refer to the outline drawing for the individual unit.
              For example, if a 50 W Ku-Band Compact Outdoor amplifier is used in a system it has a Psat = 47.0 dBm. Therefore the
              maximum input power should be limited to -28 dBm. Slightly higher input power levels will not damage the amplifier but will
              result in higher levels of distortion in the output signal.
WARNING! The maximum input level should be limited to +15 dBm to avoid damaging the amplifier.
              Figure 2 shows the input side of the Compact Outdoor Amplifier. This side contains the RF input (J1), M&C input (J4), and
              the Interface connections (J5, J6).
RF Output (J2)
                                                                       4 of 13
Unit Description, Compact Outdoor SSPA (208495-1)
              The RF Output is brought out through waveguide in the Compact Outdoor Amplifier. Figure 3 shows the output of a C-Band
              Compact Outdoor Amplifier. The Ku-Band amplifiers have a WR75 grooved flange, while the C-Band and X-Band amplifiers
              have CPR style grooved flanges (CPRG-137 for C-Band; CPRG-112 for X-Band). Ka-Band amplifiers utilize a WR28
              grooved flange. S-Band units are fitted with Type N (F) connectors at the RF Output.
Figure 3: Outline Drawing, RF Output Side, Compact Outdoor SSPA (C-Band shown)
RF Hazards apply! Never look into an open waveguide when the amplifier is operating.
              Caution should be observed here to ensure that the antenna or a suitable termination is connected to this port before
              operating the amplifier. The amplifier is protected against full reflection but dangerous levels of microwave energy can be
              present at this port.
                      Note: Different manufacturers of the MS3116F18-32P circular connector use different labeling
                     conventions, and pin "j" may appear to be pin "I". This manual uses the convention of pin "j".
See the SSPA Operational Basics section for details on special functions available on Port J4.
                                                                        5 of 13
Unit Description, Compact Outdoor SSPA (208495-1)
                                                                   6 of 13
Unit Description, Compact Outdoor SSPA (208495-1)
Note: See previous revisions of this manual for units with serial numbers less than 300000.
                                Pin # on J5                                                   Connection
                                     A                                                         LINK OUT
                                     B                                                          LINK IN
                                  C, D, E                                                  NO CONNECTION
                                     F                                                            GND
                                Pin # on J6                                                   Connection
                                  A, B, D                                                  NO CONNECTION
                                     C                                                          +28 VDC
                                     E                                                           POS 2
                                     F                                                           POS 1
                                      Pin # on J7                                                   Connection
                                            A                                                             L1
                                            B                                                            GND
                                            C                                                             L2/N
                     WARNING! Always terminate the RF input and output connectors prior to applying prime AC input
                    power!
              The power supplies provide universal AC input by using auto-sensing power supplies. The AC input can operate over a
              range of 90-265 VAC, at 47 to 63 Hz. The power supply is also power factor corrected, enabling the unit to achieve a power
              factor greater than 0.93.
                                                                      7 of 13
Unit Description, Compact Outdoor SSPA (208495-1)
              Refer to the unit's specification sheet for information regarding prime power vs. RF output power. The specification sheet
              shows whether your unit operates at 90-265 VAC or 180-265 VAC. An option for 110 VAC prime power is available for the
              higher-powered units.
              Leakage current may exceed 3.5 mA. A connection to earth ground must be made prior to connecting AC mains. Likewise,
              when removing AC mains, keep earth ground connected.
              For the connection to earth ground, use a 12 AWG cable, UL rated for outdoor use. Connect to the chassis ground stud
              using the supplied hardware. Tighten all hardware securely with a wrench.
                      WARNING! The protective earth pin B must be connected to AC mains earth for both safety and EMC
                    regulation compliance.
                      Note: For safety purposes, an isolation switch may be included in the power cable to serve as a
                    disconnect device in the event of an emergency or for unit servicing. The amplifier itself has no on/off
                    switch. As soon as AC power is applied to the unit, the unit's power supplies and microcontroller are
                    enabled. The internal amplifier module is disabled until the Mute Line Input (J4, Pin B) is pulled to Ground
                    (J4, Pin V).
                                      Pin # on J7                                                    Connection
                                             B                                                           +48V
                                             C                                                           +48V
                                             D                                                           +48V
                                             K                                                           -48V
                                             L                                                           -48V
                                             M                                                           -48V
                                             N                                                           GND
                                   Pin # on J7                                                    Connection
                                         A                                                       No Connection
                                         B                                                            +48V
                                         C                                                            +48V
                                         D                                                            -48V
                                         E                                                            -48V
                                                                       8 of 13
Unit Description, Compact Outdoor SSPA (208495-1)
                                        F                                                       No Connection
                                        G                                                            GND
                                  Pin # on J7                                                   Connection
                                       A                                                      External Fault In
                                       B                                                        Fault Pull-up
                                       C                                                         +15V LNA
                                       D                                                          Ground
                                       E                                                       +15V External
                                       F                                                          Ground
                                                                      9 of 13
Unit Description, Compact Outdoor SSPA (208495-1)
              In addition to the I/O connectors, the Compact Outdoor user-friendly features include a summary alarm indicator and
              removable fan tray.
              The cooling system is based on a forced convection technique in which the system fans provide the air intake while the
              exhaust is brought out around the outer perimeter of the fans. The air intake and exhaust are both located on the bottom side
              of the amplifier. The intake is brought through three fans while the exhaust is along the two rows of heatsink fins.
              A minimum clearance of 6 inches (152 mm) should be maintained between the bottom of the amplifier and any mounting
              surface. This will ensure that there is no forced re-circulation of airflow from exhaust to intake.
WARNING! The Compact Outdoor SSPA should NEVER be mounted with the fans facing up!
              The fans should be examined periodically and any obstruction or debris should be cleared. Inadequate air flow can cause the
              amplifier to overheat and cause a temperature fault. See the Maintenance and Troubleshooting Section for instructions on
              how to clean the fan assembly and heatsink.
              In system configurations, ensure that each unit in the system has sufficient ambient airflow, and adequate space to maintain
              the fans for each unit. Figure 5 shows an improper method for mounting a Compact Outdoor SSPA system. Not only do the
              fans oppose each other, thereby potentially causing thermal issues, but the configuration leaves insufficient space to remove
              the fans to periodically clean the heatsink.
                                                                       10 of 13
Unit Description, Compact Outdoor SSPA (208495-1)
                     (2) N-type dust caps - (1) at J1 RF Input Port; (1) at J3 Sample Port
                     (1) #20 circular MIL connector shell cap at J7 AC Input Port
                     (1) #18 circular MIL connector shell cap with chain at J4 M&C Port
                     (3) #10 circular MIL connector shell cap with chain - (1) at J5 Link Port;
                     (1) at J6 Switch Port; (1) at J8 Aux Power Port
              Each connector cover should be screwed to the appropriate connector and tightened until snug. These covers provide a dust
              and water resistant seal to the capped connector. Remove the cover before attempting to connect a cable to the connector.
              Unit Weights
              The Compact Outdoor SSPA is available in a variety of frequency bands and power levels, and have a multitude of options
              which makes each unit weigh slightly different from another.
              The following chart, Table 8, outlines the weights for the most common power levels of Compact Outdoor SSPA and
              additional weight add-ons for common options.
                 Band       Power Level        Base Weight [lbs. (kg)]       With zBUC [lbs. (kg)]        With 110 VAC Option [lbs. (kg)]
                C-Band         < 100W                 36.5 (16.6)                  +1.7 (+0.8)                         N/A
                C-Band          100W                  36..8 (16.7)                 +1.7 (+0.8)                         N/A
                C-Band          140W                  37.0 (16.8)                  +1.7 (+0.8)                      +1.9 (+0.9)
                C-Band          200W                  37.8 (17.2)                  +1.7 (+0.8)                      +1.2 (+0.6)
                C-Band          250W                  45.4 (20.6)                  +1.7 (+0.8)                      +1.2 (+0.6)
                C-Band      300W - 400W               46.9 (21.3)                  +1.7 (+0.8)                         N/A
               Ku-Band          < 40W                 35.1 (16.0)                  +1.7 (+0.8)                         N/A
               Ku-Band           40W                  35.3 (16.1)                  +1.7 (+0.8)                         N/A
               Ku-Band       50W - 70W                35.7 (16.2)                  +1.7 (+0.8)                         N/A
               Ku-Band      100W - 125W               42.5 (19.3)                  +1.7 (+0.8)                      +1.2 (+0.6)
                X-Band           60W                  46.3 (21.1)                  +1.7 (+0.8)                         N/A
                X-Band       75W - 100W               46.7 (21.2)                  +1.7 (+0.8)                         N/A
                X-Band          140W                  47.5 (21.6)                  +1.7 (+0.8)                      +1.2 (+0.6)
                X-Band          200W                  54.9 (25.0)                  +1.7 (+0.8)                      +1.2 (+0.6)
                X-Band          250W                  56.4 (25.6)                  +1.7 (+0.8)                         N/A
                S-Band       50W - 100W               36.0 (16.4)                      N/A                             N/A
                S-Band      200W - 300W               44.0 (20.0)                      N/A                             N/A
               Ka-Band           40W                  44.3 (20.2)                  +1.7 (+0.8)                         N/A
               Ka-Band           80W                  44.3 (20.2)                  +1.7 (+0.8)                         N/A
              Safety Considerations
              These instructions are designed to be used by a single operator. As such, several safety issues should be kept in mind
              during the installation.
              The Teledyne Paradise Datacom Compact Outdoor SSPA unit weighs approximately 36 lbs., and should be handled with
              care to avoid scratching the exterior coating and compromising the unit's corrosion resistance.
All bolts should be tightened to within reasonable limits to avoid stripping the threads.
The section of antenna boom the unit is to be mounted on should be straight, dry, and free from corrosion or defects.
                                                                        11 of 13
Unit Description, Compact Outdoor SSPA (208495-1)
              Inspection
              On receiving the Universal Compact Outdoor Mounting Kit, inspect the contents to ensure all parts listed in Table 9 are
              present.
              * Kits are supplied with two different All-thread lengths (11.0 in. or 15.0 in.) depending on the installation. The 11-inch All-
              thread allows mounting on booms up to six inches in diameter. The 15-inch All-thread allows mounting on booms up to 10
              inches in diameter.
              Installation
              Locate the mounting studs on the bottom of the Compact Outdoor SSPA unit. Using a 1/2" bolt, two flat washers, and a 1/2"
              nut, firmly bolt one mounting bracket to each mounting stud, as shown in Figure 6. Be sure each bracket is vertical, and the
              top flange of the mounting bracket points away from the unit.
              Place one piece of Uni-Strut (open channel up) at each end of the CO unit, across the flanges of the mounting brackets,
              lining up the holes. For each All-Thread stud, run on a 1/2" nut approximately 1" from the rod end. Slip on a lock washer, and
              thread the short end of the stud through the Uni-strut and mounting flange. Secure firmly in place with a flat washer and nut.
              The unit should now look as shown in Figure 7.
                                                                         12 of 13
Unit Description, Compact Outdoor SSPA (208495-1)
              Bring the unit up tight under the boom (with the long axes parallel), sliding the All-Thread studs past the sides of the boom to
              show above the boom top. Place the remaining pieces of Uni-strut (open channel down) across the boom, onto the
              protruding All-Thread stud ends. Secure firmly with a flat washer and ½" nut on each of the four All-Thread stud ends.
              Looking from the end of the boom, the mounted unit should look as shown in Figure 8.
              All cable connections should be properly sealed against water intrusion. Any moisture in a microwave coaxial connection will
              have adverse effect on the operation of the equipment. Apply self-amalgamating tape or putty from the plug/socket
              connection (MS-type) to as close as possible to the cable sheath. Cover all connector junctions (N-type; SMA) so that no
              water can creep into the thread between the plug and socket. Prior to taping a connector, remove all traces of oil or grease
              from the connector by using an alcohol-based cleaning solution. Ensure that the connector is clean and dry.
                                                                                    13 of 13
THIS PAGE LEFT INTENTIONALLY BLANK
Outdoor SSPAs, Quick-Start (216595-2)
                                                                                1 of 11
Outdoor SSPAs, Quick-Start (216595-2)
              Teledyne Paradise Datacom Outdoor SSPAs are available with a standard Ethernet & RS-232/RS-485 interface. This section
              summarizes the connections to a remote computer for various remote communications.
See the appropriate description of the Compact Outdoor or High Power Outdoor connections to Port J4.
                                                                     2 of 11
Outdoor SSPAs, Quick-Start (216595-2)
              For convenience all amplifiers ship with a 'Quick-Start' communications cable. This allows the user to immediately connect
              the amplifier to a PC and begin operation. Ethernet ready units ship with a Quick-Start cable fitted with a 10-base T
              connector as shown in Figure 1.
              Customers may request a Quick-Start cable configured for RS-232 communications and fitted with 9-pin D-sub connector as
              shown in Figure 2.
                                                                       3 of 11
Outdoor SSPAs, Quick-Start (216595-2)
              This section describes the necessary steps to communicate with an amplifier using either the Ethernet or RS-232 Quick-Start
              cables and the Teledyne Paradise Datacom Universal M&C Software. The Universal M&C Software is a free Windows-based
              application that can be downloaded from the company web site, www.paradisedata.com.
                      Note: The amplifier has no on/off switch or circuit breaker in the AC Input path. As soon as AC power is
                    applied, the unit's power supplies and microcontroller are enabled. However, the RF output of the internal
                    amplifier module is disabled until the Mute Line Input (J4 - Pin B) is pulled to Ground (J4 - Pin V). Both the
                    Ethernet Quick-Start and RS-232 Quick-Start cables provide this connection.
              Set PC Configuration
              To set your Windows-based PC to remotely communicate with the amplifier, perform the following steps:
              1. Open the PC's Control Panel (Start Menu > Settings > Control Panel);
              2. Double-click on the Network Connections icon;
              3. Right-click on the Local Area Connection icon and select Properties;
              4. Select Internet Protocol (TCP/IP) and click on the Properties button;
              5. Select "Use the following IP address" and enter the following information:
              ..... IP address: 192.168.0.1
              ..... Subnet mask: 255.255.255.0
              6. Click the "OK" button and close out of the Control Panel windows.
              1. Click on the Windows icon in the lower left corner and select Control Panel;
              2. Click on the Network and Sharing Center link;
              3. Click on the Local Area Connection link;
              4. Click on the Properties button;
              5. Select Internet Protocol Version 4 (TCP/IP v4) and click on the Properties button;
              6. Select "Use the following IP address" and enter the following information:
              ..... IP address: 192.168.0.1
              ..... Subnet mask: 255.255.255.0
              7. Click the "OK" button and close out of all of the Control Panel windows.
                                                                        4 of 11
Outdoor SSPAs, Quick-Start (216595-2)
                       IMPORTANT! If the unit is powered up with the Ethernet Quick Start Cable connected to Port J4, the
                     following default conditions apply to the unit:
                     • IPNET Interface
                     • Gateway: 192.168.0.1
                     • IP Address: 192.168.0.9
                     • Subnet Mask: 255.255.255.0
                     • Local Port: 1007
                     • IP Lock: 255.255.255.255
                     • Web password: paradise
                     • Read Community: public
                     • Write Community: private
                     • Amplifier is unmuted
                       IMPORTANT! If the unit is powered up with the RS-232 Quick Start Cable connected to Port J4, the
                     following default conditions apply to the unit:
                     • Normal Protocol
                     • RS-232 Communication
                     • Baud rate: 9600
                     • Amplifier is unmuted
              Communication Links using RS-232 are typically good up to 30 ft. (9 m) in length. Installations exceeding this length can use
              the RS-485 mode which will allow serial control up to 4000 ft. (1200 m).
                                                                         5 of 11
Outdoor SSPAs, Quick-Start (216595-2)
                    IMPORTANT! If the Quick Start cable is attached to Port J4 of the unit before power is applied, the unit
                   will always start up with the default IP settings. Teledyne Paradise Datacom recommends that the operator
                   build a custom cable that leaves Port J4 pins "j" and "e" unpopulated. This custom cable will prevent the
                   default settings from being used if the unit experiences an unexpected power cycle.
                                                                 6 of 11
Outdoor SSPAs, Quick-Start (216595-2)
              Teledyne Paradise Datacom provides a free version of its Universal Monitor and Control (M&C) Software available for
              download from its web site. Install the software on a PC running Windows 7 or later.
Navigate to the Support > Downloads page and click on the latest version of the sofware to download the zip file.
              Unzip the package and run the setup.exe file. This launches the Universal M&C Software installer. Follow the prompts and
              agree to the license agreement to install the application. When complete, close the installer.
See the Universal M&C Instruction section for directions on how to use the Universal M&C software with your unit.
                                                                       7 of 11
Outdoor SSPAs, Quick-Start (216595-2)
              The most basic method of communication with the outdoor unit is via a web browser, which accesses the built-in web pages
              served from the amplifier's embedded web server. Starting with firmware version 6.40, the application no longer requires
              Java.
              The web interfaces uses a standard hypertext transfer protocol on port 80. The web interface is compatible with most
              modern web browsers, such as Firefox, Chrome or Internet Explorer, which support asynchronous JavaScript XML
              transactions (aka AJAX).
              Once the host PC has been configured and connected to the amplifier using the Quick Start cable, the user may open a web
              browser page, select File > Open, and enter the IP address of the networked amplifier into the browser's address field. The
              default IP address is 192.168.0.9. See Figure 3.
A security login window will appear. Enter the default username (admin) in the User Name field. See Figure 4.
              The User Name is fixed and cannot be changed by the operator. In the Password field, enter the web password assigned to
              the unit. The factory default password is paradise. The User Name and Password are case sensitive. The password may be
              changed at any time and may comprise up to 15 alpha-numeric characters. If you forget the web password you will need to
              connect to SSPA via Universal M&C to verify it.
Click on the [Log In] button to open the M&C control in the web browser.
                    Status tab: A Read-Only view of critical device operation conditions (voltages, current consumption, attenuation)
                    and fault alarm statuses.
                    Communication Settings tab: Read/Write listings of communication related parameters, including: IP, SNMP, Web
                    settings as well as serial port settings.
                    General Settings tab: Read/Write listings of all redundancy and amplifier specific settings.
                    Fault Settings tab: Read/Write listing of fault operation related settings;
                                                                       8 of 11
Outdoor SSPAs, Quick-Start (216595-2)
                       Note: While the image of a Compact Outdoor SSPA is shown in the Web M&C windows, the software is
                     valid for use with both the Compact Outdoor and High Power Outdoor amplifiers.
              Status Tab
              Upon opening, the browser window displays the Status tab, which shows the major conditions and faults affecting the
              connected amplifier. See Figure 5.
Fault indicators are either colored green when no fault condition exists, or red when a fault condition exists.
              The top bar of SSPA Monitor and Control application shows whether the connected unit is exhibiting a summary fault, and
              also displays the device's online status, transmit status, Forward and Reflected RF power (if available) and RF module core
              temperature. This information is displayed regardless of which tab is selected.
              The left side of the window displays unit model and serial number, firmware build, device MAC address and device up time
              since last I/O card power up or reboot. The connection status is also displayed, along with the Web/XML version, and a link
              to the quick-start guide. This information is displayed regardless of which tab is selected.
                                                                         9 of 11
Outdoor SSPAs, Quick-Start (216595-2)
The Communication Settings window, shown in Figure 6, displays the current values of the following parameters:
                    IP Settings (IP Address, Gateway Address, Subnet Mask, Lock Address, Trap Manager Address and IP Port)
                    SNMP Read/Write Communities and Web Password
                    Serial Network Address
                    Communication Interface Type
                    Baud Rate
                    SNMP Trap Conditions
                     Note: Changes to certain settings (marked with an asterisk in Figure 6) require a power cycle of the unit
                    before the new setting will take effect.
              The General Settings window, as shown in Figure 7, displays the Amplifier and Redundancy Settings. Amplifier Settings
              include: Gain Control; Attenuation Level adjustment (in dB); Automatic Level Control (ALC) RF Level (in dBm); Mute Setting
              (Mute clear or Mute set); and Fan Speed selection (High, Low or Auto).
                     Note: The High Power Outdoor SSPA initially starts up in the Muted state; Change the Mute Setting in the
                    General Settings tab to enable Transmit RF.
              Redundancy Settings include: Operation Mode (Standalone, 1:1 Redundant, Dual 1:1, or Maintenance Switch); Hierarchical
              Address (HPA1 or HPA2); Standby Select (Online or Standby); Standby Mode (Hot Standby or Cold Standby); and Switch
              Mute (Switch Mute On or Switch Mute Off).
                      Note: The Standby Select setting allows the operator to select whether the unit should start up as the on-
                    line amplifier or the standby amplifier. When in a redundant system configuration, if the Standby Select
                    setting is changed from the Online state to the Standby state, the system will drive the switch so that
                    another amplifier in the system is in the Online state. Only the Online amplifier can give away its Online
                    state. This setting is saved upon unit shut-down, and the unit will start up in the last saved state.
                      Note: When multiple High Power Outdoor SSPAs of certain high RF power levels are set up in a
                    redundant configuration, the Switch Mute setting should be turned on. See Section 8.1.2.2.
                                                                     10 of 11
Outdoor SSPAs, Quick-Start (216595-2)
The Fault Settings window, as shown in Figure 8, allows the user to adjust the fault settings for the connected amplifier.
              In the box at left, use the pull-down menus to select the desired Fault Type, Handling, or Logic parameters. Enter new values
              for the Forward or Reflected RF Fault Levels.
              In the box at right, use the pull-down menus to select the desired Auxiliary Fault Type and Logic and the desired BUC Fault
              Type and Logic.
Click the [Confirm] button to save the fault settings, or the [Reset] button to rever to the previously saved settings.
                      Warning! Take care when setting the Fwd.RF Flt Level or Ref.RF Flt Level values. If the values are set
                     within the normal operating levels for your amplifier, unnecessary fault conditions may be triggered.
                                                                                    11 of 11
THIS PAGE LEFT INTENTIONALLY BLANK
Outdoor SSPAs, Operational Basics (216595-3)
                                                                                1 of 10
Outdoor SSPAs, Operational Basics (216595-3)
              The Teledyne Paradise Datacom outdoor amplifier is available with a standard RS-232/RS-485 serial communications
              interface or an optional Ethernet & RS-232/RS-485 interface. This section summarizes the connections to a remote computer
              for various remote communications.
              Ethernet ready units can be configured for either RS-232, RS-485, or Ethernet communications. The units cannot be used
              with multiple communication protocols simultaneously. The user must select one of the three formats. Non-Ethernet units can
              be configured for either RS-232 or RS-485 communications.
                                                                      2 of 10
Outdoor SSPAs, Operational Basics (216595-3)
Figure 5 shows the proper configuration of J4 for communication over RS-485 for legacy units.
Figure 6 shows the proper configuration of J4 for communication over RS-232 for legacy units.
Figure 7 shows the required connection between the chassis ground and the isolated ground (pin V to pin d).
                                                                      3 of 10
Outdoor SSPAs, Operational Basics (216595-3)
               Figure 7: J4 Connections for RS-485 Communications for Compact Outdoor SSPAs of Serial Numbers > 300,000 in
                          systems with M&C cables designed for Compact Outdoor SSPAs of Serial Numbers < 300,000
              If it is not possible to modify the existing cable harness or otherwise externally connect the chassis ground Pin V to the
              isolated return at Pin d as shown in Figure 7, consult the factory for other options.
                                                                        4 of 10
Outdoor SSPAs, Operational Basics (216595-3)
Refer to Table 1 in the Unit Description section for the pin-outs for Port J4.
                       Note: The state of these pins is sensed by the SSPA unit only at power up! Changing the state of these
                     pins during normal unit operation will not affect the selected type of interface.
              Compact Outdoor units with the 4th generation of I/O cards allow the use of multiple concurrent interfaces. These units have
              serial numbers greater than 400,000 or firmware version 6.00 and above. By default, most available interfaces will be kept on
              and can be used simultaneously without any limiting factors. Legacy NDSat interface is disabled by default, but is still
              available as a specific selection.
              For compatibility purposes, some legacy protocol selection is still available. Selecting SNMP protocol will disable IPNet
              operation and internal web page function; Selecting NDSat protocol will disable Normal serial protocol. Terminal mode
              protocol was re-introduced to the protocol stack with version 6.60. Selecting Terminal mode will disable Normal protocol
              operation over serial port. IPNet, web and SNMP interfaces will continue to operate normally. It is possible to use Baud
              Select pins j and e to force specific IP address and protocol. See Table 2.
              Pins j and e on the J4 M&C connector have internal pull-ups and if left disconnected will remain in logic high state. The
              reverting function of the SSPA is active only on initial power-up. Any alterations to the pins' state after start-up will allow the
              SSPA to use internal EEPROM settings to select the baud rate and protocol.
              Automatic Addressing
              Pins j and e on the J4 M&C connector are also used for automatic addressing (for I/O board firmware levels of 3.50 or later).
                                                                          5 of 10
Outdoor SSPAs, Operational Basics (216595-3)
                      Note: SSPA address in EEPROM must be set to 0xAA in order to activate the Unique Network Address
                     Hardware Select option.
                      Note: For proper FSK interface operation, the SSPA internal settings must be selected to 9600 Baud and
                     Normal protocol. Do not make a connection to interface control pins Baud1 and Baud0!
                       Note: For maximum ESD protection of a SSPA's Serial interface internal circuit, the RS-232/RS-485
                     interface is isolated from the SSPA chassis ground. Serial interface has a separate interface ground pin
                     (Pin d on the J4 connector). Connecting this pin to common ground will effectively disable the protection
                     circuit and may cause interface failure.
                      All interface lines are equipped with transient suppression devices. Adding extra transient protection to
                     communication lines is not required and may cause interface failure!
              If it is desired to have the RF enabled every time the AC input is applied, a permanent connection can be made from J4-Pin
              B and Pin V.
RF Hazards apply! Never look into an open waveguide when the amplifier is operating!
                                                                         6 of 10
Outdoor SSPAs, Operational Basics (216595-3)
The desired method of attenuation control mode must be set over remote interface.
              Attenuation control over remote interface (Serial, IP, Web or SNMP) is the default method of controlling SSPA linear gain. In
              this method of control, the specific attenuation is selected using the Embedded Web page or Universal M&C GUI, or sent as
              a remote control command. The SSPA will retain the selected attenuation level in non-volatile internal memory until a new
              command or selection is issued by the user.
              In analog voltage control mode, the user needs to apply positive voltage between (J4, Pin A) and Ground (J4, Pin V) from an
              external source. The applied voltage will be translated to the SSPA attenuation level and will determine the linear gain of
              SSPA unit as follows:
              Voltage increments by 0.1V in a range between 0.5 to 2.5V will reduce the amount of attenuation by 0.1 dB steps. Voltages
              below and above this limit will be treated as lower and upper limits of adjustment range. Gain adjust input typically has 20
              kOhm pull down to the signal ground. Hence, with no external voltage applied, the SSPA will default to minimum gain (55
              dB).
              Upon activation, the ALC function will take over control of the amplifier's internal attenuator and maintain the RF output level
              set point. The Forward RF alarm level is set automatically to the selected ALC output. The Forward RF alarm function will
              also be set to 15% Window mode. If the Forward RF alarm is not needed, it could be deactivated or set to a different level or
              function after ALC mode is set.
                       Note: When Automatic Level Control is engaged, the user's ability to modify the amplifier's attenuation
                     setting is disabled.
              The ALC circuit will have the greatest ability to adjust for positive and negative RF input level changes when the amplifier's
              gain level is typically at the midrange value of 65 dB (with the Internal attenuator set to 10 dB).
              The ALC function has the ability to accurately control the RF output power over a 15 dB range from Psat, with an accuracy of
              1 dB. ALC will operate over a 20 dB range, but the accuracy of the last 5 dB will suffer. For example, if the saturated power
              from the amplifier is 59 dBm, the lowest accurate power setting during ALC control is 44 dBm.
              The ALC function in Compact Outdoor and High Power Outdoor SSPAs includes the capability of adjusting the ALC level
              without having to disable the ALC function.
                                                                        7 of 10
Outdoor SSPAs, Operational Basics (216595-3)
Figure 8: Set Gain Control to External or Serial Port and Attenuation to 10.0 dB
Adjust the input signal to achieve the desired RF output and allow amplifier output to stabilize;
                      Note: If the ALC level is set outside the amplifier's detectable forward RF range, the ALC Level will
                    automatically reset to either the maximum or minimum value, depending on whether the setting was
                    higher or lower than the detectable range.
Change the Gain Control setting to ALC Control (see Figure 9);
Note that when ALC Control is initially set, the Forward RF Fault settings will change:
                    Change the Forward RF Fault Status setting to Disable (see Figure 10);
                    Change the ALC Level to the new desired setting;
                    Change the Forward RF Fault Threshold setting to the same value as the new ALC Level;
                    Change the Forward RF Fault Status setting to Fifteen Percent Window;
                    Make sure the Forward RF Fault Handling setting is set to Major Fault in Online Mode.
                                                                        8 of 10
Outdoor SSPAs, Operational Basics (216595-3)
              Alarms (J4)
              A variety of alarm signals are present at the M&C connector, J4. Both Form-C relays and open collector outputs are
              available. An amplifier summary alarm is available in both Form C relay and open collector output. Detailed internal faults are
              available in open collector form and include: voltage, current, and over-temperature.
              The Auxiliary Input is a contact closure to ground. When this input is pulled to ground the Auxiliary Alarm relay is energized
              (Normal State). When the Auxiliary Input is open circuited the Auxiliary Alarm relay is de-energized (Alarm State).
              One example usage of the Auxiliary Alarm in non-Ethernet units is that it could be used to signal one of the detail alarms
              (voltage, current, or temperature) by connecting the appropriate open collector alarm output to the Auxiliary Input. This
              programs the Auxiliary Alarm relay to be either a voltage, current, or temperatue Form C relay alarm.
                                                                        9 of 10
Outdoor SSPAs, Operational Basics (216595-3)
                   Auto: This setting allows the unit to control the cooling fan speed according to the internal RF module temperature.
                   If the module plate temperature remains below 50 °C, the fan speed will be set to minimum. If the registered
                   module plate temperature is above 50 °C, unit will gradually increase the fan speed. Fan speed will reach
                   maximum at a plate temperature of 65 °C.
                   High: This option sets the fan speed to maximum. Air velocity will remain at the same level regardless of other
                   operation parameters.
                   Low: This option sets the fan speed to minimum. Air velocity will remain at the same level regardless of other
                   operation parameters.
                   Default/Off: This setting should be set on units without the fan speed control option. It will allow proper functioning
                   of the RF power monitor analog output. Applying this setting on units with the fan speed control option allows the
                   fan speed to be proportional to the output RF level. Fan speed will be set at the minimum when output RF is below
                   a detectable level. Fan speed will gradually increase when RF output increases within the detectable RF range.
                   Fan speed will be at maximum level when unit reaches saturated power (Psat).
                                                                                  10 of 10
L-Band Operation (216594-3)
                                                                              1 of 12
L-Band Operation (216594-3)
              Teledyne Paradise Datacom SSPAs are available with various L-Band up converter options. The primary up converter option
              is the Zero dBm Block Up Converter, ZBUC. The ZBUC ® block up converter is offered in C-Band, X-Band, and Ku-Band
              configurations. The ZBUC converter offers ultra low phase noise for applications where phase noise is an overriding factor.
              The type of ZBUC converter housed within your SSPA is indicated by its model number, as shown in Figure 1. The example
              in Figure 1 shows a 200W 3RU C-Band Rack Mount SSPA with Internal Reference ZBUC converter. For a full description of
              the configuration matrix, refer to the specification sheet for your amplifier.
              The block up converters are high performance frequency translation devices which provide excellent phase noise and
              spurious performance.
              The ZBUC converter utilizes Teledyne Paradise Datacom's proprietary "Smart Reference Technology". Smart Reference
              Technology allows the system user to change reference frequency and power level or choose internal or external reference
              without requiring any system configuration. An internal ZBUC converter adds about 1.7 pounds to the overall weight of the
              SSPA.
              In rack mountable amplifiers, the block up converter is powered from a +15 VDC supply available from the Back Plane Board
              Assembly of the SSPA. The Block Up Converter is simply cascaded with the SSPA at the input of the amplifier. Figure 2
              shows the basic block diagram of the rack mount SSPA.
              In outdoor amplifiers, the block up converter is powered from a +15 VDC supply available on the Fan Boost Converter board
              assembly. The Block Up Converter is simply cascaded with the SSPA at the input of the amplifier.
              It is important to remember the requirement of a 10 MHz reference oscillator when operating an SSPA with ZBUC converter
              (SSPB). If the 10 MHz reference is not present, the M&C will report a BUC alarm and the SSPA module will mute. This
              ensures that no spurious or 'off frequency' transmission could originate from the unit.
                      Note: Unless the ZBUC converter has the built-in internal reference option, if there is no 10 MHz
                    reference signal present on the IFL input there will be no output signal from the SSPA.
                                                                      2 of 12
L-Band Operation (216594-3)
              This section describes the features available in the Teledyne Paradise Datacom ZBUC converter. The ZBUC converter is
              available as an option for the C-Band, X-Band and Ku-Band SSPA. Table 1 shows the specifications for the respective
              frequency plans.
                                                                    3 of 12
L-Band Operation (216594-3)
              The ZBUC converter is a low gain block up converter with a P1dB of 0 dBm. This topology allows the system to be integrated
              with little impact on the general electrical specifications of the SSPA module.
              The ZBUC converter utilizes single up conversion from L-Band to the desired RF band. The local oscillator circuits are
              designed to maintain the lowest possible output phase noise. The frequency synthesizer utilizes industry leading technology
              which allows for phase noise performance previously unattainable in PLL design. See Table 2.
                Offset      Guaranteed<br />Max.     C-Band<br />(typical)     X-Band<br />(typical)     Ku-Band<br />(typical)      Units
                10 Hz                 -30                      -60                       -58                        -56             dBc/Hz
               100 Hz                 -60                      -74                       -70                        -60             dBc/Hz
                1 kHz                 -70                      -87                       -80                        -78             dBc/Hz
               10 kHz                 -80                     -100                       -94                        -91             dBc/Hz
               100 kHz                -90                     -105                       -97                        -94             dBc/Hz
                1 MHz                 -90                     -125                      -122                       -120             dBc/Hz
              Band selectivity is accomplished using the most aggressive filtering possible while maintaining specified power and spurious
              performance.
              External reference is applied to the ZBUC converter via the L-Band input IFL and is routed to the frequency synthesizer
              using the built-in demux circuitry.
              Note: The external reference option requires the system operator to provide system reference to the ZBUC/SSPB. The
              system will not lock and will have no output without external reference applied.
Note: Internal reference option allows for either internal or external reference operation.
                1. Launch the Universal M&C application and connect to the outdoor unit over RS232 or RS485 comms.
                2. Select the Settings tab in the Universal M&C window.
                3. Change the BUC Reference setting to External.
                4. Cycle power to the amplifier to save the new setting.
                      Note: Changing this setting when communicating with the outdoor ampliifer over IPNET will not work
                    properly. Communication must be over RS232 or RS485!
                                                                        4 of 12
L-Band Operation (216594-3)
                Frequency Stability:
                  ≤ ± 3 · 10-8 over temperature range -20 to +85 °C
                  ≤ ± 1 · 10-9 aging per day (after 30 days)
                  ≤ ± 6 · 10-8 aging per year (after 30 days)
                Warm up time: 20 minutes @ 25 °C for better than ≤ ± 1 · 10-8
                Phase Noise:
                   10 Hz    -120 dBc/Hz
                  100 Hz    -140 dBc/Hz
                    1 KHz   -145 dBc/Hz
                   10 KHz   -152 dBc/Hz
                  100 KHz   -155 dBc/Hz
                Frequency Accuracy: Factory preset to ± 3 · 10-8
                                                                       5 of 12
L-Band Operation (216594-3)
              FSK Monitor and control comes standard with a ZBUC converter installed in an outdoor SSPB. This allows the outdoor
              amplifier to be fully and remotely monitored and controlled through the system's IFL. An embedded controller enables remote
              communication and fault detection via the IF input between the SSPA and a Teledyne Paradise Datacom Q-Series L-Band
              modem. This signal consists of a 650 KHz Frequency Shift Keyed carrier that is multiplexed onto the L-Band input IFL along
              with the 10 MHz reference signal.
              The FSK input has a center frequency of 650 KHz with a ± 5% tolerance. The FSK deviation is ± 60 KHz, with +60 KHz being
              a "mark" and -60 KHz being a "space". The FSK input will work over an input power range of -5 to -15 dBm. The FSK
              characteristics are summarized below:
                                                                      6 of 12
L-Band Operation (216594-3)
              This section shows the Rack Mount SSPB in a common system application. Figure 3 shows the amplifier used with a
              Teledyne Paradise Datacom Q-Flex L-Band Modem.
                                                                    7 of 12
L-Band Operation (216594-3)
              Consideration should be given to using a high quality IFL between the indoor and outdoor equipment. The system designer
              must always consider the total cable loss for a given length and also the implications of the slope of attenuation across the
              950 to 1450 MHz bandwidth. Table 3 gives the approximate attenuation vs. frequency for a variety of cable types.
              It is recommended to use a quality grade of 50 ohm cable such as Belden 9913, 9914, or 7733. Check the manufacturer's
              technical data to make sure that the insulation is sufficient for the particular installation including the cable's temperature
              range. Also make sure the coaxial connector from the IFL cable to the amplifier input is wrapped with a weather sealing tape
              to prevent water intrusion into the coaxial cable.
                                                                        8 of 12
L-Band Operation (216594-3)
              When redundant systems are configured with Block Up Converters, the systems engineer must be know whether the BUCs
              have internal 10 MHz reference oscillators or if they are configured for external 10 MHz reference only. When the Block Up
              Converter loses its 10 MHz reference, the converter will trigger an alarm condition. This alarm condition then disables (or
              mutes) the amplifier's RF output. This is done so that any uplinked signal does not drift off frequency or emit spurious outputs
              to the satellite.
              Converters that have an internal 10 MHz reference oscillator will automatically switch to an externally applied reference. In
              this case, if the external reference is removed, the converter will switch to the internal reference and a BUC alarm will not be
              triggered.
              This section shows various configuration options in which the 10 MHz BUC reference can be distributed to amplifiers in a
              redundant system. Particular attention need to be placed on 1:2 Redundant systems because the standby amplifier must
              have a 10 MHz reference so that it does not remain in a faulted condition.
              Option 1 is standard for all 1:2 systems using BUC option 'M' (internal reference), for 1:1 systems with input switching using
              BUC option 'M' (internal reference), and for 1:1 systems with input splitting using either BUC option 'M' (internal reference) or
              'P' (external reference).
              In the systems shown in Figure 4 and Figure 5, each online amplifier operates from its own internal reference oscillator but
              will automatically detect and switch to an external 10 MHz reference supplied at the RF input. The Standby amplifier
              operates only from its own internal reference oscillator.
                                                                         9 of 12
L-Band Operation (216594-3)
              Figure 6 shows the standard configuration for 1:1 systems with input splitting. The SSPBs will automatically detect and
              switch to an external reference applied at the IF input.
Figure 6: 1:1 Redundant System, Input Splitter, Internal or External Reference BUCs
              In this case, the 10 MHz input for the Standby amplifier is provided by the customer via a separate input, as shown in Figure
              7 and Figure 8. In redundant systems, the input reference is diplexed onto the coaxial line feeding the input of the Standby
              amplifier.
                                                                      10 of 12
L-Band Operation (216594-3)
              Option 3 is standard for all 1:2 systems using BUC option 'P' (external reference) and for all 1:1 systems with input switching
              using BUC option 'P' (external reference).
              In this case, a single 10 MHz reference input is split and diplexed to the IF input of each amplifier as shown in Figure 9 and
              Figure 10.
Figure 10: 1:1 Redundant System, Single Reference Diplexed to Each Amplifier
                                                                       11 of 12
L-Band Operation (216594-3)
              In this case, individual 10 MHz references are diplexed to the IF input of each amplifier as shown in Figure 11 and Figure 12.
              This gives the systems engineer the greatest flexibility and control over the 10 MHz reference input to each SSPA.
Figure 11: 1:2 Redundant System, Individual References Diplexed to Each Amplifier
Figure 12: 1:1 Redundant System, Individual References Diplexed to Each Amplifier
                                                                                    12 of 12
Maintenance and Troubleshooting, Compact Outdoor SSPA (208495-2)
                                                                                1 of 8
Maintenance and Troubleshooting, Compact Outdoor SSPA (208495-2)
             This section describes some of the standard maintenance practices that can be performed on the Compact Outdoor
             Amplifier and tips to troubleshoot common customer issues.
                                                                   2 of 8
Maintenance and Troubleshooting, Compact Outdoor SSPA (208495-2)
             It is recommended that the cooling system be checked at least once per month. This involves visually inspecting the fan
             intakes to make sure that there is no obstructions over the intake. The Windows-based M&C program can be used to check
             the amplifier base plate temperature. The base plate temperature should normally not exceed a 30 °C to 35 °C rise above
             the current outside ambient temperature. If the base plate temperature exceeds this temperature rise, it is one indicator that
             the system's airflow requires maintenance.
             The heatsink fins in the exhaust path can be visually inspected for excessive dirt and debris buildup. If it appears there is
             excessive debris in the heatsink; the fan tray can be removed for easy cleaning. Failure to keep the fans and heatsink
             clear of debris will void your warranty!
                                                                        3 of 8
Maintenance and Troubleshooting, Compact Outdoor SSPA (208495-2)
             It is recommended to remove prime AC power from the amplifier when the fan tray is being removed. However, if necessary,
             the fan tray can be removed while the amplifier is operating. Caution should be used to make sure that no clothing or fingers
             are caught in the fan blades.
                   Unscrew the four screws that secure the fan tray to the enclosure.
                   Slide the fan assembly out of the enclosure, taking care not to damage the gasket on the fans.
                   The fans are connected to their power source by weatherized in-line circular connectors.
                   Spray compressed air throughout the finned area of the heatsink. A can of dust remover spray such as that which
                   is found at a computer or electronics shop will work fine.
                   All debris should be removed before installing the fan tray.
             Fan Replacement
             Spare fan assemblies can be ordered from the factory for replacement, should one or more fans on the unit fail. Older
             models of the Compact Outdoor SSPA were fitted with a two fan cooling fan assembly. Newer models utilize a three fan
             cooling fan assembly.
             While the fan interface connectors for the two fan and three fan tray assemblies are identical, they should not be used
             interchangeably.
             If your Compact Outdoor SSPA was shipped from the factory with the three fan air intake tray, any maintenance requiring fan
             replacement should only use the three fan kit (L205192-X, where X is the build specific to your amplifier. Consult the
             factory.). The replacement three fan kit includes the entire fan assembly including the three fans, power cable, and tray with
             finger guards. Power to the three fan kit is provided directly from the unit's bus bar.
             If your Compact Outdoor SSPA was shipped from the factory with the two-fan air intake tray, any maintenance requiring
             replacement of the fans should only use fan kit (L201814-1). This kit replaces one fan on the fan tray assembly. Power to the
             two fan kit is provided from the booster circuit card assembly.
Note: Failure to use the proper fan tray will damage your amplifier!
             It is possible to modify an older Compact Outdoor SSPA to be fitted with a three fan cooling fan assembly in place of a two
             fan assembly. This should be done by a Teledyne Paradise Datacom technician, using the procedure outlined in drawing
             number 206573.
                                                                       4 of 8
Maintenance and Troubleshooting, Compact Outdoor SSPA (208495-2)
             Teledyne Paradise Datacom digital engineers continually strive to improve the performance of CO SSPA software and
             firmware. As this occurs, software and firmware upgrades are made available. The web upgrade is performed over the SSPA
             IP port and does not require any special software. It can be performed through any suitable web browser.
                     Important! Upgrading the unit with incompatible firmware image may damage the equipment hardware.
                   To ensure the proper firmware image file is used, contact Teledyne Paradise Datacom technical support.
                   Write down your current firmware version. You may want to request an image file of the current firmware in
                   case it becomes necessary to revert back to the original.
             Connect the SSPA to PC 10/100 Base-T network adapter via a Quick-start Ethernet cable. See the Quick-Start Ethernet
             Connection section. With a Quick-start cable connected, the SSPA will use a fixed IP address, 192.168.0.9. Advanced users
             may use a custom cable and custom IP address. However, this procedure only covers connection over a fixed IP address.
Make sure unit is power cycled with Quick-start cable plugged in. It will ensure unit assumes fixed address, 192.168.0.9.
             Open a web browser window (Chrome, Firefox or IE are preferred). Enter the following address in the location window of the
             browser: 192.168.0.9/fw
             The Upload Form is password protected. An authentication window should come up to ensure authorization. Use "admi"n as
             the User Name and the HPA web login as the Password (default password is paradise). Click the [Log In] button (see Figure
             2).
             The firmware upload form will load in the browser window (See Figure 3). Click the "Choose File" button and select the
             firmware image code.bin file provided by technical support.
Click the "Upload" button. A warning message will appear; click the "OK" button (See Figure 4).
                                                                       5 of 8
Maintenance and Troubleshooting, Compact Outdoor SSPA (208495-2)
             The upload process will begin and the form will monitor the loading process. Do not interrupt this process and wait until its
             completion with positive or negative result. The process may take up to 15 minutes. When completed, the form will notify
             about end of process. See Figure 5.
             During the upgrade process, the HPA remains fully functional. The new firmware will stay dormant until the next reboot of the
             HPA control card. Reboot the controller card by cycling AC power to the HPA. Check installed version by logging to SSPA
             embedded web page.
                                                                        6 of 8
Maintenance and Troubleshooting, Compact Outdoor SSPA (208495-2)
             The following section describes solutions for some of the most common issues with the operation of the Compact Outdoor
             SSPA.
Possible causes:
                   AC power is off;
                   Unit which requires 220V AC operation is being powered from 110V AC grid;
                   Unit is connected to an inadequate circuit breaker;
                   Unit has no connection between chassis and earth ground or has inadequate earth ground.
Possible solutions:
                   Check SSPA unit datasheet for AC power requirements. Provide the specified AC power for the unit;
                   Re-check continuity between unit's chassis ground and earth ground. Earth ground connection is required for
                   normal SSPA operation!
                   SSPA peripheral alarms (Auxiliary, Spare, Forward RF etc) are set as Major alarms;
                   Summary Alarm is caused by external reference BUC module.
Possible solutions:
                   Connect to the SSPA unit via the Universal M&C software and disable peripheral alarms;
                   In the case where the unit is equipped with an externally referenced BUC, provide the specified reference signal to
                   the SSPA IF input.
Possible solutions:
                   Make sure the J4 connector has a jumper installed between pins B and V;
                   Connect to the unit via the Universal M&C and set the Mute setting to Off.
                   Check the input RF signal level and frequency. Make sure the signal properties are appropriate for the unit.
                   If Switch Mute is enabled, make sure unit is connected to a RF switch; otherwise, disable the Switch Mute option.
Possible solutions:
                                                                       7 of 8
Maintenance and Troubleshooting, Compact Outdoor SSPA (208495-2)
                   In the case where SSPA communication settings have been accidentally set to a random configuration, establish a
                   connection to the unit with a L207755 Quick Start cable in conjunction with the Universal M&C software.
                   After establishing a communication link with the unit, adjust the following settings to the desired configuration:
                   Serial Network address, Protocol Select, Baud rate (if Normal protocol was set in in the Protocol configuration), IP
                   address, Subnet, Gateway, IP port and IP lock address (if IPNet or SNMP protocols were selected), Community
                   Set and Community Get strings (if SNMP protocol was selected), web password (if IPNet was selected).
                   Disconnect the Quick start cable and cycle AC power to the unit with the custom cable harness plugged into the J4
                   M&C connector;
                   Recheck custom control link.
                   In the case of a RS-232 interface, make sure to use communication ground pin d from the J4 connector as the
                   RS-232 ground;
                   The SSPA RS-232 port is electrically isolated from chassis ground;
                   In order to use the Quick-Start cable from previous generations of Compact Outdoor SSPAs (PN L202151), the
                   cable harness will need to be modified. To do so, open the MS connector shell and connect the chassis and
                   communication ground pins together (Pins V and d).
                   In the case of IPNet, use 10Base-T approved cables (CAT5, CAT6) to make a connection to the unit;
                   Maximum cable length should not exceed 300 ft;
                   If an IP connection with custom IP addressing is desired, don't make any connection to interface selection pins j
                   and e.
Possible solution:
                   Set the SSPB protocol setting field to "Normal" protocol and/or remove any connection to SSPB interface select
                   pins j and e on the J4 connector;
                   Reset AC power.
                                                                                    8 of 8
Outdoor SSPAs, Maintenance Switch Mode (216595-4)
                                                                                1 of 2
Outdoor SSPAs, Maintenance Switch Mode (216595-4)
             An outdoor unit with firmware version 5.05 or beyond may be set up to use the switch control connector (Port J6) to control a
             single external maintenance waveguide switch (for example, to switch the output between an antenna and a dummy load).
                                      Pin# on J6                                                                              Connection
                                            A                                                                                       N/C
                                            B                                                                                       N/C
                                            C                                                                                    +28 VDC
                                            D                                                                                       N/C
                                            E                                                                                     POS 2
                                            F                                                                                     POS 1
             In Maintenance Switch Mode (see the System Settings Table, Data Address 1), a maintenance switch can be placed in
             Position 1 or Position 2 by toggling the unit's Redundant Startup State setting between the Online and Standby values. The
             actual state of the SSPA will be determined according to the currently selected hierarchical address.
             If hierarchical address "HPA1" is selected, the SSPA will drive the switch to Position 1 when the Redundant Startup State is
             selected to the "Online" value. The switch will be driven to Position 2 when the Redundant Startup State is selected to
             "Standby".
             For "HPA2", the "Online" and "Standby" selection position for the waveguide switch will be in-verted: Position 2 = "Online"
             state; Position 1 = "Standby" state.
                                      Pin# on J5                                                                              Connection
                                            A                                                                                   LINK OUT
                                            B                                                                                     LINK IN
                                            C                                                                                       N/C
                                            D                                                                                       N/C
                                            E                                                                                       N/C
                                            F                                                                                       GND
             In order to use an external line control, the Redundant Startup State must be selected to the "Online" value. In this case,
             when the LINK IN signal is left unconnected, the SSPA will drive the waveguide switch to its "Online" state; when the LINK IN
             line is connected to a chassis ground, the switch will be driven to the "Standby" position.
"Online" and "Standby" switch positions still will be determined by the hierarchical address selection.
                                                                                     2 of 2
Outdoor SSPAs, Redundant System Operation (216595-5)
                                                                               1 of 15
Outdoor SSPAs, Redundant System Operation (216595-5)
             Both the Compact Outdoor SSPA and High Power Outdoor SSPA are capable of operating in a variety of redundant system
             configurations. These include 1:1 and 1:2 as well as 1:1 with L-Band Block Up Converters. The amplifier has a built-in 1:1
             redundancy controller, allowing it to be used in 1:1 redundant systems without a separate external controller. When used in a
             1:2 redundant system a separate controller, RCP2-1200, is required. The three most common forms of 1:1 redundant system
             are shown in Figures 1 through 3.
             Figure 1 shows a standard 1:1 system in which the RF input is transmitted through a transfer switch along with the output.
             Using this configuration the standby amplifier carries no traffic and simply is terminated by a 50 ohm resistive load at its input
             and by a waveguide termination at its output.
             With the system configured as in Figure 2, the RF input is passed through a microwave splitter. This keeps 'live' traffic on the
             standby amplifier and is useful for observing the traffic via the RF sample port on the standby amplifier.
             The system shown in Figure 3 uses the same concept of the power splitter on the RF input. In this case the amplifiers are
             equipped with L-Band block up converters. L-Band input amplifiers use phase locked oscillators as the local oscillator to the
             up converter. Such systems must use a splitter at the input instead of a switch so that the reference input is always available
             to the standby amplifier. If the reference signal is lost the standby amplifier would report a BUC (Block Up Converter) fault.
Figure 3: 1:1 Redundant System, with L-Band Input and Input Splitter
             Care must be taken when selecting the splitter for an L-Band input system. The splitter must be a wide band design capable
             of passing the 10 MHz or 50 MHz reference signal along with the 950 MHz to 1525 MHz traffic input. The reference
             frequency power level must be at least -10 dBm into each amplifier.
                                                                        2 of 15
Outdoor SSPAs, Redundant System Operation (216595-5)
             The Outdoor amplifiers are ideally suited for a self-contained and cost effective 1:1 redundant system. Each amplifier has a
             built-in 1:1 redundant controller. The controller is activated via computer command from the Teledyne Paradise Datacom
             Universal M&C application. The amplifier may be purchased as a redundant system or upgraded in the field from a single
             thread amplifier to a 1:1 redundant system.
A redundancy kit may be purchased separately which includes the following components:
                   Mounting Frame
                   Waveguide Switch / Mounting Bracket
                   Input Splitter
                   Waveguide bends from amplifier to switch
                   High Power Waveguide Termination
                   Coaxial cables from splitter to Amplifier input
                   Link Cable
                   Switch Cable
                   Waveguide Flange / Extension for RF Output
             Hardware Setup
             The hardware setup for an outdoor 1:1 Redundant System is very simple and involves the addition of (2) cables along with a
             redundancy switch. A schematic diagram of the redundancy setup is shown in Figure 4.
Figure 4: 1:1 Redundant System with Link Cable and Switch Cable Installed
             The Link Cable is a simple (3) conductor crossover cable that allows the system to pass command and control between
             amplifiers. With the redundancy kit, this cable is supplied in a 26 inch (660 mm) length.
             The Switch Cable is a "Tee" configuration and connects between each amplifier and the redundancy switch. The
             Redundancy Switch is a -28 VDC type. Therefore the controller in each outdoor amplifier is capable of supplying +28 VDC to
             the common voltage input. Either controller may then provide a (sink) return to engage either position 1 or position 2 of the
             redundancy switch.
             Care must be observed when connecting this cable to the amplifiers. The cable end labeled "A1" must be connected to the
             amplifier whose output is connected to Port 3 of the waveguide switch. Likewise the cable end labeled "A2" must be
             connected to the amplifier whose output is connected to Port 1 of the waveguide switch. This is for proper identification
             purposes of the Redundancy Control Firmware used by each outdoor amplifier.
                                                                      3 of 15
Outdoor SSPAs, Redundant System Operation (216595-5)
                      Note: 1:1 Reundant Systems using Compact Outdoor amplifiers are typically shipped from the factory
                    fully assembled. See drawing number 215534 for assembly instructions for a 1:1 Redundant System using
                    High Power Outdoor amplifiers.
             Software Setup
             To instruct the system amplifiers to operate in redundancy mode, it is necessary to temporarily connect each to a PC running
             the Teledyne Paradise Datacom Universal M&C Software to set up the redundant configuration.
             Figure 5 shows the redundant system with each amplifier enabled to use RS-232 communication with a PC. Each amplifier is
             shipped from the factory with a "Quick Start" cable that can be used for this purpose. If the amplifiers are purchased as a 1:1
             Redundant System, this Software Setup procedure will have been set at the factory and it is not necessary to repeat this
             process.
             Each amplifier can be configured for redundancy by the Teledyne Paradise Datacom Universal M&C software that ships
             along with each unit. Using the Quick-Start cable, connect each amplifier to the PC and run the M&C program. Select the
             "Settings" tab from the main form. The "Settings" window will appear as shown in Figure 6.
                                                                        4 of 15
Outdoor SSPAs, Redundant System Operation (216595-5)
Set the System Mode for each SSPA to "1:1 Redundant" mode.
             Assign a Hierarchical Address for each amplifier. HPA 1 means this SSPA will use the RF switch position 1 as its Online state
             position. HPA 2 will then use RF switch position 2 (Standby).
             Set the Standby Select (formerly Redundant Startup State) setting for each amplifier. The amplifier which is desired to be
             online should be set to "Online". The other amplifier should be set to "Standby". Once the system is operating, changing the
             state of the "Online" amplifier to "Standby" will cause the system to drive the switch so that the other amplifier is in the
             "Online" state. Attempting to change the "Standby" amplifier to the "Online" state will have no effect. This setting is saved
             upon unit shut-down, and the unit will start up in the last saved state.
             All settings are valid as soon as the operator sets them on the SSPA Settings window. The SSPA's redundant operation can
             be verified by monitoring the RF Switch Fault indicator as shown in Figure 14.
             The Standby amplifier can be muted to have a "Cold Standby" condition. It keeps the SSPA module powered down for power
             savings while the microprocessor and fans remain operational. SSPAs with Parallel I/O board firmware version 3.50 or
             beyond are provided with a true cold standby mode. In this mode, the SSPA will be muted automatically. Cold standby mode
             has to be selected through a serial control interface (For details, see the System Settings Table, data address 20).
             If the Standby amplifier switches to the Online state, it will automatically un-mute and transmit traffic. If the operator attempts
             to mute the Online amplifier a warning message will be displayed: "Muting this amplifier will not affect the Redundancy State
             of the system, do you really want to mute?"
             Similarly, connect the second amplifier to the computer's COM port and perform the 1:1 selections on the SSPA Settings
             window. Just as with the first amplifier, make sure that the System mode is set to 1:1 redundant. Select a hierarchical
             address, HPA 1 or HPA 2 and a startup state.
             The amplifiers may then be disconnected from the computer's COM port as the outdoor amplifiers' microcontroller is now
             programmed for 1:1 redundancy control. It is not necessary to run the Windows based M&C software with the redundant
             system. The M&C software is only a convenience for remote monitoring and control of the redundant system.
             Switch Mute
             The Switch Mute option was introduced into the SSPA control setup to overcome a problem with microwave arcing, which
             may potentially damage a switching component if switching RF power exceeds 400 Watts. This particular problem becomes
             a critical issue if coaxial RF pass switches are used.
             When this mode is selected, as shown in Figure 7, the amplifier is momentarily muted during switchover to prevent arcing in
             the waveguide. The SSPA also will be forced to the mute state if the transfer switch malfunctions, is disconnected from SSPA
             or gets stuck between positions.
                                                                         5 of 15
Outdoor SSPAs, Redundant System Operation (216595-5)
             In general, all Teledyne Paradise Datacom SSPAs are well protected against high reflected power conditions which may take
             place during output microwave switchover. But with certainty, waveguide or coaxial switches will develop an internal electrical
             arc during switchover if the output power is significant. Such conditions will not lead to instant failure, but over time may
             diminish some critical RF switch characteristics.
             If the switch mute feature is enabled, the system ability to output RF power will be bonded to the switch position sensing
             circuitry. This circuitry consists of the following components: a SSPA electronic switch position detector; a wiring harness
             between the SSPA and RF switch; and RF switch position sensors. Failure of any of these components will lead to a break in
             transmission.
             In addition, a SSPA with the switch mute feature enabled will be forced to the mute state when used in standalone mode
             without a connected RF switch. Standalone units must be set with the switch mute option disabled, or set up in Standalone
             mode operation prior to using a SSPA without a connected RF switch.
             When using RS232, a separate COM port will be required for each amplifier. Therefore a computer with at least two COM
             ports is required for such a system. Systems using RS232 are limited by the length of the communication cable from the
             amplifiers to the computer. This is typically a maximum of 30 ft. (9 m) for most RS-232 device drivers. Systems requiring
             longer communication cable links should use RS-485 communication.
             After starting the M&C program, select [Action] > [Add Unit] > [Compact Outdoor SSPA] or [High Power Outdoor SSPA],
             depending on unit type. See Figure 8. The Add New SSPA window will appear as shown in Figure 9.
                                                                       6 of 15
Outdoor SSPAs, Redundant System Operation (216595-5)
             From this screen choose the COM port and baud rate. The factory default baud rate is 9600. If a single SSPA is used, the
             Global network address setting should be used.
             After the COM port has been selected, click the Create button. This will launch the Monitor and Control display for the
             connected unit. If the SSPA is connected to a power source and turned on, the SSPA will begin communicating with the M&C
             program and its operating parameters (Status Tab) will be displayed, as shown in Figure 10.
             Go back to the "Add New Local SSPA" window and select the correct COM port for the second amplifier. Its operation
             window will appear on the M&C program display. If either of the amplifiers is not communicating with the M&C Operation
             screen, debug the system to find the problem. Check the RS-232 connection from each amplifier to the appropriate COM
             port of the PC.
             Once reliable communication has been established between each amplifier and the computer, the Redundancy Control
             Panel can be displayed. From the M&C program's main window, choose [Action] > [Internal Redundant System] > [1:1
             Compact Outdoor SSPA System]. See Figure 11.
                                                                     7 of 15
Outdoor SSPAs, Redundant System Operation (216595-5)
Figure 11: Universal M&C Program, Add 1:1 Compact Outdoor SSPA System
                     Use the [1:1 Compact Outdoor SSPA System] setting for systems using either Compact Outdoor SSPAs
                   or High Power Outdoor SSPAs.
Select the amplifiers to be assigned as Unit 1 and Unit 2 and enter a name for the system. See Figure 12.
Figure 12: Universal M&C Program, Add 1:1 Compact Outdoor SSPA System
             Note that either amplifier may be designated as Unit 1 or Unit 2. Each amplifier is identified by its ID number. The Unit ID
             number is a fixed number and cannot be changed. It is a unique encoded value determined by the particular amplifier's
             model number and serial number. If the ID number is forgotten, refer to the System Watcher window. This window
             continuously displays which amplifier, by ID number, is connected to each specific COM port. After the Control Panel has
             been configured the display will change to the view shown in Figure 13.
                                                                       8 of 15
Outdoor SSPAs, Redundant System Operation (216595-5)
             From the Control Panel display all typical 1:1 system functions can be monitored and controlled. A particular SSPA can be
             put on line be selecting the command button for either amplifier. The online amplifier will be indicated by the "Online"
             notation. The standby amplifier will be listed as such as shown in Figure 13 (Unit 2).
             A particular redundant configuration can be saved by going to the "File" menu and selecting "Save Configuration". Thus if the
             program is terminated and then restarted, it will immediately boot up with the Redundancy Control Panel display.
             Each individual amplifier's characteristics can still be monitored and controlled from its respective "Operation" window. If the
             user attempts to Mute an on-line amplifier, a warning window will pop-up asking if this is a valid request. See Figure 14.
Figure 14: Universal M&C Program, Warning When Muting Online Amplifier
             If the online amplifier enters a fault condition, the redundant switch will automatically route the signal to the Standby amplifier.
             The faulted amplifier will be colored red in the Redundancy Control Panel display. See Figure 15.
                                                                         9 of 15
Outdoor SSPAs, Redundant System Operation (216595-5)
             By clicking on the [Unit1] button (which will be labeled to correspond to the unit's name), the M&C Status window for Unit1 is
             activated, so the user may determine the cause of the fault. See Figure 16.
Figure 16: Unit1 Status Panel Showing Summary and Temperature Faults
             Once the fault is cleared, Unit1 can be reactivated as the online unit by clicking on the triangular amplifier symbol for Unit2 in
             the System1 control panel.
             If the redundant switch is manually rotated to the offline amplifier in a redundant system, an RF switch fault will occur. The
             system will not attempt to switch back to its original position. On the Redundancy Control Panel, both amplifiers will be
             colored red. The switch must be manually rotated back to the online amplifier.
                                                                       10 of 15
Outdoor SSPAs, Redundant System Operation (216595-5)
             The RS-485 link can typically be run up to 4000 ft. (1200 m) lengths. A good quality twisted pair cable should be used along
             with proper line terminations. There are no parallel end terminations in the amplifier's RS-485 interface. Any required cable
             terminations have to be added externally. Either full or half duplex RS-485 communication is supported. Schematics showing
             the proper wiring of each version are shown in Figures 17 and 18.
             As in the stand-alone redundant system, each amplifier must be programmed for redundant system operation by using the
             RS-232 interface and M&C program. Similarly when networking SSPAs on a RS-485 network, each amplifier's address must
             be set before they can communicate over the network. Both of these steps should be performed together as part of the initial
             system setup.
Figure 17 shows a typical 1:1 Redundant System with RS-485 Full Duplex Communication.
Figure 17: 1:1 Redundant System with RS-485 Full Duplex Communication
Figure 18 shows a typical 1:1 Redundant System with RS-485 Half Duplex Communication.
Figure 18: 1:1 Redundant System with RS-485 Half Duplex Communication
                                                                     11 of 15
Outdoor SSPAs, Redundant System Operation (216595-5)
             The outdoor amplifier can also be configured in 1:2 Redundant Systems. A 1:2 Redundant System typically has two transmit
             paths, one on a horizontal polarity and the other on a vertical polarity. The system provides automatic switchover to the spare
             SSPA to either polarization path in case of a primary SSPA malfunction. In the case of two SSPA malfunctions, the backup
             SSPA can be switched to either polarization path, according to a polarization priority selection setting.
             The standard 1:2 configuration has HPA1 online in the polarization 1 path, HPA3 online in the polarization 2 path, and HPA2
             acting as spare backup for ether HPA1 or HPA3. A separate RCP2-1200 Redundant System controller is required to provide
             system control. The controller is used to constantly check the state of the controlled HPAs and, in case of malfunction, rotate
             the waveguide switches according to an internal logic table. The controller can be remotely located from the amplifiers at a
             distance of up to 500 ft. (152.4 m). Figure 19 shows a block diagram of a typical 1:2 Redundant System configuration.
                     Note: 1:1 Reundant Systems using Compact Outdoor amplifiers are typically shipped from the factory
                   fully assembled. See drawing number 215534 for assembly instructions for a 1:1 Redundant System using
                   High Power Outdoor amplifiers.
             Hardware Setup
             The outdoor 1:2 Redundant System uses three SSPAs mounted to a uni-strut frame and a waveguide redundancy switch
             array. An indoor RCP2-1200 redundant system controller provides monitor and control functions.
             A Switch Cable connects between the controller (Port J3) and each switch in the redundancy switch array. The redundancy
             switches are typically a -28 VDC type. The controller supplies +28 VDC over this cable to the common voltage input.
             A Control Cable connects between the controller (Ports J5 and J8) and each HPA (Port J4) in the system, and is used to
             pass monitor and control signals.
             All cable ends are marked with labels indicating to which port the connector must be mated. For proper system operation, all
             cables must be properly connected.
             Software Setup
             Operational settings for amplifiers configured for use in a redundant system are typically set up at the factory prior to
             shipment. If the user is using an amplifier not configured for a redundant system, the amplifier settings must be changed for
             such use. Temporarily connect the amplifier to a PC running the Teledyne Paradise Datacom Universal M&C Software to set
             up the redundant configuration.
                                                                      12 of 15
Outdoor SSPAs, Redundant System Operation (216595-5)
             Each outdoor amplifier is shipped from the factory with a "Quick Start" cable that can be used to change operational
             parameters. Using the Quick-Start cable, connect each amplifier to a PC running the Universal M&C software. Select the
             "Settings" tab from the main form, and assign the following parameters to each HPA.
             The above settings are valid as soon as the operator sets them on the SSPA Settings window. The SSPA's redundant
             operation can be verified by monitoring the RF Switch Fault indicator.
If connecting over an Internet connection, each amplifier must be assigned a unique IP address on the network.
             After starting the M&C program, select [Action] > [Add Unit] > [Compact Outdoor SSPA] or [High Power Outdoor SSPA],
             depending on the type of unit used in the system. See Figure 20.
The Add New SSPA window will appear as shown in Figure 21.
             From this screen, choose the COM port and baud rate. The factory default baud rate is 9600. If a single SSPA is used, the
             Global network address setting should be used.
                                                                      13 of 15
Outdoor SSPAs, Redundant System Operation (216595-5)
             After the COM port has been selected, the "Operation" window will be displayed. If the unit is connected to a power source
             and turned on, the SSPA will begin communicating with the M&C program and its operating parameters will be displayed, as
             shown in Figure 22.
             Add each amplifier to the M&C program, selecting the correct COM ports for the other amplifiers. The operation windows will
             appear on the M&C program display. If any of the amplifiers is not communicating with the M&C Operation screen, debug the
             system to find the problem. Check the RS-232 connection from each amplifier to the appropriate COM port of the PC.
             Once reliable communication has been established between each amplifier and the computer, the Redundancy Control
             Panel can be displayed. From the M&C program's main window, choose [Action] > [Add Unit] > [Controller]. See Figure 23.
             The Redundant Control Panel window will then be displayed as in Figure 24. Note that once the Redundant Control Panel is
             enabled, the Main Menu on the M&C program changes.
                                                                    14 of 15
Outdoor SSPAs, Redundant System Operation (216595-5)
                                                                                 15 of 15
THIS PAGE LEFT INTENTIONALLY BLANK
Outdoor SSPAs, Phase Combined System Operation (216595-6)
                                                                               1 of 14
Outdoor SSPAs, Phase Combined System Operation (216595-6)
             Phase combining amplifiers has long been a popular means of increasing the output power of an amplifier system. Under
             high power microwave conditions it is common to utilize some form of waveguide hybrid coupler to combine the output power
             of two amplifiers. This coupler is generally a waveguide tee such as a four port magic tee. On the input side, common coaxial
             power splitters can be utilized to divide the power due to the lower power levels at the input of the system.
             Figure 1 shows a typical block diagram of a phase combined amplifier pair. As long as the electrical delay, phase and
             amplitude of the two paths are kept within close tolerance of each other, the output power of the system will be twice the
             output power (+3 dB) of a single amplifier.
             The main drawback of this approach is that in the event of an amplifier failure, the total output power decreases by 6 dB, or a
             factor of 4. This does not offer the system much in the way of redundant capability with such a large decrease in output
             power capability. The power decrease is due to the fact that with only one amplifier active, the output combiner acts as a
             power divider. The output power from the remaining amplifier is divided between the output of the system and the terminated
             port of the hybrid combiner. Thus only one half of the power from one amplifier reaches the output port which is 6 dB less
             than the combined output power from both amplifiers.
             A high power system requiring a degree of redundancy needs some means of bypassing the combiner in the event of an
             amplifier failure. This would allow the full output power capacity of the remaining amplifier to reach the output. In this case
             the total RF output power would only decrease by 3 dB from the phase combined output power. A 3 dB reduction in output
             power is generally more tolerable to a system's link budget thereby giving the system a degree of redundancy.
             A technique has been developed which accomplishes phase combining and provides redundancy with two waveguide
             transfer switches. A block diagram of such a system is shown in Figure 2.
                                                                        2 of 14
Outdoor SSPAs, Phase Combined System Operation (216595-6)
             This type of system is sometimes referred to as a "Fixed Phase" combined (FPC) system to differentiate it from the Variable
             Phase Combiner (VPC) systems commonly used with TWTAs. In the 1:1 Fixed Phase Combined system, the waveguide
             switches allow the amplifier outputs to either be directed into the combiner or bypass the combiner and connect directly to
             the RF output.
             Teledyne Paradise Datacom has developed a series of controllers that greatly enhances the operation of the phase
             combined system. The FPRC-1100 Phase Combined System Controller is designed specifically to control 1 for 1 Fixed
             Phase Combined redundant amplifier systems. The FPRC-1200 Phase Combined System Controller allows remote control
             of 1 for 2 Fixed Phase Combined redundant amplifier systems.
             Each controller can be used in either manual or automatic mode to monitor the system amplifiers for faults and operate the
             transfer switches. The controller has a very user friendly interface that allows the operator to monitor the composite output
             power of the system and adjust the gain of the amplifiers in 0.1 dB increments over a 20 dB range. The controller adjusts
             each amplifier in the system and keeps the amplitude of each balanced for optimal power combining. To the operator, the
             system appears as a single amplifier. The operator can choose between using the system as a phase combined system or a
             traditional redundant system.
                                                                      3 of 14
Outdoor SSPAs, Phase Combined System Operation (216595-6)
             Under normal 1:1 phase combined system operation, both HPA #1 and HPA #2 are on-line. Their output power is combined
             at the magic-tee waveguide combiner. The waveguide combiner has an integrated RF sample port that provides a sample of
             the RF output. This port feeds an RF attenuator/diode detector combination. The detector's output voltage is sent back to the
             Signal box via a coaxial cable and linked to the FPRC-1100 Redundant Controller.
             The FPRC-1100 is a 1 RU high indoor controller that can remotely monitor and control the 1:1 Fixed Phase Combined
             system. The controller has a very user friendly interface that allows the operator to monitor the composite output power of
             the system and adjust the gain of the amplifiers in 0.1 dB increments over a 20 dB range. The controller adjusts each
             amplifier in the system and keeps the amplitude of each balanced for optimal power combining.
             The FPRC-1100 can be used in automatic or manual mode. In manual mode if a fault occurs in one of the amplifiers, a fault
             will be indicated on the front panel but no waveguide switch change will occur. In automatic mode the controller will
             determine the appropriate waveguide switch positions and switch the remaining two amplifiers on line. This will ensure that
             the system is operating at full output power capability.
             The FPRC-1100 front panel is shown in Figure 3. In most cases the user will place the controller in Auto mode so that the
             controller can determine the proper switch position in the event of an amplifier failure. The mimic display shows the position
             of each waveguide switch by lighting an LED in the waveguide switch path.
                    Note: See drawing number 216351 for detailed information on the installation and operation of the
                   FPRC-1100 Phase Combined System Controller.
Figure 4: Block Diagram, 1:1 Fixed Phase Combined System with Signal Box, Typical
                                                                       4 of 14
Outdoor SSPAs, Phase Combined System Operation (216595-6)
             The signal box also contains a phase shifter. This phase shifter is in cascade with the RF input to HPA #1. This allows the
             phase of the amplifiers to be adjusted to achieve optimum power combining. The amplifiers are phase adjusted at the factory
             to achieve the best balance of power across the full operating bandwidth.
             The system should not normally require phase adjustment in the field unless an amplifier has been replaced. See the Phase
             Adjustment section for instructions on adjusting the phase.
                                                                       5 of 14
Outdoor SSPAs, Phase Combined System Operation (216595-6)
The basic 1:1 Fixed Phase Combined system topology is very similar to a 1:1 redundant system and is shown in Figure 5.
Figure 5: Block Diagram, 1:1 Fixed Phase Combined System with L-Band Input, Typical
             When in Automatic mode, the waveguide switches (SW1 and SW2) either direct each amplifier output to the waveguide
             phase combiner or, if lower output power is required, bypasses the combiner and sends an individual amplifier output to the
             system output.
             The system shown in Figure 5 utilizes a RCP2-1100 redundant system controller for the redundant BUC system housed in
             the signal box, along with the FPRC-1100 phase combined system controller to control the SSPAs and output switch array.
             A FPRC-1100 controller directs the HPA output switches and monitors the amplifiers. While the system is operating in phase
             combined mode, and an amplifier enters a fault condition, the controller will switch the faulted amplifier offline. This provides
             a soft-fail mode and results in a power decrease of 3 dB to the system output power.
             The BUC switch (SW3) is driven by an indoor RCP2-1100 redundant system controller. When a BUC fault is detected, the
             switch is driven to place the faulted BUC offline without user intervention.
             This system may also be operated via manual mode. This mode of operation may offer some benefits over automatic
             operation. When in manual mode, the amplifiers will not switch out of Phase Combined mode or switch to the operational
             amplifier without user intervention if an HPA fault occurs.
             However, if a BUC fault occurs, the RCP2-1100 will direct SW3 to place the operational BUC online. A fault indicator will be
             present on the front panel of the RCP unit, but the system output would be unaffected by the BUC fault.
                                                                        6 of 14
Outdoor SSPAs, Phase Combined System Operation (216595-6)
             The signal box also contains a phase shifter. This phase shifter is in cascade with the RF input to HPA #1. This allows the
             system to achieve optimum power combining and is factory set for the best possible combining across the full operating
             bandwidth of the amplifier.
             The system should not normally require phase adjustment in the field unless an amplifier has been replaced. See the Phase
             Adjustment section for instructions on adjusting the phase.
                                                                      7 of 14
Outdoor SSPAs, Phase Combined System Operation (216595-6)
             The 1:2 Phase Combined Redundant System is a popular system architecture that enables Solid State Power Amplifiers to
             achieve higher output power levels while building in full-power redundancy. The basic system topology is similar to a 1:2
             redundant system and is shown in Figure 6.
             In this system, amplifiers #1 and #3 are normally online. The outputs of #1 and #3 are directed by the waveguide switches
             into a fixed phase combiner such as a waveguide "magic tee" style combiner. In the event of a failure of either on line
             amplifier, the standby amplifier, #2, can be switched in place of either #1 or #3 and the system maintains full output power.
             The 1:2 Phase Combined System is controlled by an FPRC-1200 1:2 System Controller. Detailed information on the
             installation and operation of the FPRC-1200 can be found in the unit's operations manual, Teledyne Paradise Datacom
             drawing #216351.
             The FPRC-1200 can be used in automatic or manual mode. In manual mode, if a fault occurs in one of the amplifiers, a fault
             will be indicated on the front panel but no waveguide switch change will occur. In automatic mode, the controller will
             determine the appropriate waveguide switch positions and switch the remaining two amplifiers online. This will ensure that
             the system is operating at full output power capability.
             The output power of a phase combined system is roughly two times the output power of the single SSPA. Some loss in the
             transmission line (at the switches and combiners) should be expected which prevent a true doubling of output power.
             System designers find that the 1:2 Phase Combined Amplifier System topology is a very cost effective solution to realizing
             high power amplifier systems. For example, it is less expensive to configure a 1 kW redundant system using (3) 500W
             amplifiers in a 1:2 Phase Combined system than it is to use (2) 1 kW amplifiers in a traditional 1:1 Redundant System.
                                                                       8 of 14
Outdoor SSPAs, Phase Combined System Operation (216595-6)
             Under normal 1:2 phase combined system operation, HPA #1 and HPA #3 are online, and HPA #2 is in standby mode as
             shown in Figure 7.
Figure 7: Block Diagram, 1:2 Phase Combined System with Signal Box, Typical
             The output power of the online units is combined at the magic-tee waveguide combiner. The 1:2 system has an integrated
             RF sample port that provides a sample of the forward RF output and is calibrated over the system's operational frequency. A
             second port feeds an RF attenuator/detector combination. The resultant signal is sent back to the Signal box via a coaxial
             cable and linked to the FPRC-1200 Redundant Controller.
             The FPRC-1200 is a 1 RU high indoor controller that can remotely monitor and control the 1:2 Fixed Phase Combined
             system. The controller has a very user friendly interface that allows the operator to monitor the composite output power of
             the system and adjust the gain of the amplifiers in 0.1 dB increments over a 20 dB range. The controller adjusts each
             amplifier in the system, keeping the amplitude of each balanced for optimal power combining.
             The FPRC-1200 can be used in automatic or manual mode. In manual mode if a fault occurs in one of the amplifiers, a fault
             will be indicated on the front panel but no waveguide switch change will occur. In automatic mode the controller will
             determine the appropriate waveguide switch positions and switch the remaining two amplifiers on line. This will ensure that
             the system is operating at full output power capability.
             The FPRC-1200 front panel is shown in Figure 8. In most cases the user will place the controller in Auto mode so that the
             controller can determine the proper switch position in the event of an amplifier failure. The mimic display shows the position
             of each waveguide switch by lighting an LED in the waveguide switch path.
             In normal operation, HPA #2 should be selected as the standby amplifier. HPA #2 is the middle amplifier on the amplifier
             frame. This allows the outputs of HPA #1 and HPA #3 to be combined at the waveguide combiner. If HPA #1 or HPA #3 were
             to ever fail, HPA #2 would be switched in place of the failed amplifier, and the system will maintain full output power
             capability over the full operating bandwidth of the system. Figure 9 shows the FPRC-1200 front panel mimic display with
             HPA #2 selected as the standby amplifier.
                                                                       9 of 14
Outdoor SSPAs, Phase Combined System Operation (216595-6)
                    Note: See drawing number 216351 for detailed information on the installation and operation of the
                   FPRC-1100 Phase Combined System Controller.
             The FPRC-1200 controller is a 1RU external controller specifically designed to handle a 1:2 phase combined system. It not
             only handles all traditional fault monitoring and switching duties, but also provides an overall system monitor and control
             facility.
             The signal box also contains two phase shifters. These phase shifters are in cascade with the RF inputs to HPA #1 and HPA
             #3. This allows the system to achieve optimum power combining and is factory set for the best possible combining across
             the full operating bandwidth of the amplifier.
             The system should not normally require phase adjustment in the field unless an amplifier has been replaced. See the Phase
             Adjustment section for instructions on adjusting the phase.
                                                                     10 of 14
Outdoor SSPAs, Phase Combined System Operation (216595-6)
             The system shown in Figure 10 utilizes a RCP2-1100 redundant system controller for the redundant BUC system housed in
             the signal box, along with the FPRC-1200 phase combined system controller to control the SSPAs and output switch array.
Figure 10: Block Diagram, 1:2 Phase Combined System with L-Band Input, Typical
             The FPRC-1200 controller directs the HPA output switches and monitors the amplifiers. While the system is operating in
             phase combined mode, and an amplifier enters a fault condition, the controller will switch the faulted amplifier offline. This
             provides a soft-fail mode and results in no power decrease to the system output power.
             The BUC switch is driven by an indoor RCP2-1100 redundant system controller. When a BUC fault is detected, the switch is
             driven to place the faulted BUC offline without user intervention.
             This system may also be operated via manual mode. This mode of operation may offer some benefits over automatic
             operation. When in manual mode, the amplifiers will not switch out of Phase Combined mode or switch to the operational
             amplifier without user intervention if an HPA fault occurs.
             However, if a BUC fault occurs, the RCP2-1100 will direct the BUC switch to place the operational BUC online. A fault
             indicator will be present on the front panel of the RCP unit, but the system output would be unaffected by the BUC fault.
             The signal box also contains two phase shifters. These phase shifters are in cascade with the RF inputs to HPA #1 and HPA
             #3. This allows the system to achieve optimum power combining and is factory set for the best possible combining across
             the full operating bandwidth of the amplifier.
             The system should not normally require phase adjustment in the field unless an amplifier has been replaced. See Section
             8.6.2 for phase adjustment instructions.
                                                                       11 of 14
Outdoor SSPAs, Phase Combined System Operation (216595-6)
                                                                   12 of 14
Outdoor SSPAs, Phase Combined System Operation (216595-6)
             The 1:1 or 1:2 phase combined system is phase adjusted for optimum performance across the operating frequency band at
             the factory, and no adjustments are typically needed except in the event that a SSPA has been replaced.
             The SSPAs are manufactured to a delay specification, but an adjustment may be necessary to achieve the maximum output
             power in the system at the desired frequency of operation.
             Alternately, you may use the FPRC-1100 controller's output power display (available by tapping the Status button on the
             touchscreen, tapping the SSPA RF button, and reviewing the displayed System Fwd RF value shown in the upper right of the
             display).
             Remove the cover from the Signal Box and loosen the locking nut on the phase adjuster (7/16") knob and slowly rotate the
             knob clockwise. See Figure 11. Continue to rotate the knob until the output power is peaked. If no peak is found, rotate
             counter-clockwise until output peaks.
             For optimum performance across the entire frequency range of the SSPA system, repeat the steps above at the low end of
             the operating frequency band, and again at the high end of the operating frequency band. It may be necessary to find the
             best compromise in output power for broadband use.
             The BUCs are outside the phase combined loop. Therefore, replacing a BUC will not impact the phase combining of the
             system, and no adjustment of the phase shifter is necessary.
             Once the phase adjustments are complete, tighten the locking nut on the phase adjustment knob and securely fasten the
             cover back on to the Signal Box.
             Alternately, you may use the FPRC-1200 controller's output power display, available by tapping the Status button on the
             touchscreen, tapping the SSPA RF button, and reviewing the displayed System Fwd RF value shown in the upper right of the
             display.
             The two phase adjusters are located inside the Signal Box and are labeled PA1 and PA2. See Figure 12. To make
             adjustments, first loosen the 7/16" locking nut on the phase adjuster knob.
                                                                      13 of 14
Outdoor SSPAs, Phase Combined System Operation (216595-6)
             To adjust the phase combining, un-mute the amplifiers and, using the FPRC-1200, set HPA #1 as the standby amplifier.
             Apply a CW signal (mid-band). With HPA #2 and #3 power combined, phase adjuster (PA2) will be used to maximize the
             output power. Vary phase adjuster 2 (PA2) to peak the power reading on the power meter or spectrum analyzer, or from the
             FPRC-1200 controller's output power display. Record the Pout. Measure and record the Pout at the system's low frequency,
             and again at the system's high frequency.
             Next, select HPA #2 as the standby. This combines HPA #1 and HPA #3. Use phase adjuster (PA1) to optimize power. Vary
             phase adjuster 1 (PA1) to peak the power reading on the power meter or spectrum analyzer, or from the FPRC-1200
             controller's output power display. Record the Pout.
             Select HPA #3 as the standby amplifier. This combines HPA #1 and HPA #2. Measure the output power and record the Pout
             at the system's low frequency, mid-band, and high frequency.
             Compare the output powers from all three phase combined configurations; the results should be similar. If the results differ,
             repeat the steps above to achieve the best balance for all three amplifier configurations across the operating frequency band.
             Choose the best compromise in power for all combinations so that if a switch-over on fault does occur, there is no noticeable
             increase or decrease in output power.
             After phase combining is complete use the locking nut on each phase adjuster to secure the adjustment knob so no
             accidental changes to the combining occur.
             Before placing the system back in operation, replace the cover to the Signal Box, and reconnect the detector and attenuator
             to the cross-guide coupler, ensuring the connection is sealed against moisture intrusion.
                                                                                  14 of 14
Outdoor SSPAs, Remote Control Protocol (216595-7)
                                                                                1 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
              A system which includes an SSPA can be managed from a remote computer over a variety of remote control interfaces (see
              Figure 1).
              Serial interface can be selected between RS-232/RS-485, Ethernet 10/100Base-T or FSK over IFL input (FSK interface is
              available only on units with an optional L-Band block up converter). RS-232/RS-485 interface can be used in conjunction with
              Paradise CO SSPA serial protocol (aka Normal protocol) or Legacy Paradise VSAT BUC serial protocol (aka VSAT protocol).
                      Note: Binary protocol used on previous generation units are no longer supported. Terminal protocol was
                    re-introduced starting with version 6.60
              Outdoor SSPAs are capable of supporting simultaneous multiple remote control interfaces, depending on the protocol
              selection settings and drive of Baud0 and Baud1 pins on J4 M&C connector. See Table 2 under the Operational Basics
              section.
              The Ethernet interface for units with firmware version 6.0 or later utilizes industry standard 10/100 Base-T IP protocol and
              supports the IPv4 addressing schema. Units with previous firmware versions use 10 Base-T IP protocol. Normally, straight-
              through Cat5e/Cat6 cable is used to connect the unit to a network hub, and a crossover Quick-Start cable is used to connect
              directly to a computer's Ethernet port.
                     Note: The supplied Quick Start cable is a crossover cable designed to connect the unit directly to a PC's
                    NIC card. Some network hubs and switches are not equipped with an auto cable sense feature and may
                    not work with this cable!
                                                                      2 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
              This section describes the normal communication protocol between the CO SSPA and a host computer over RS-232/RS-485
              serial interface. Serial port settings on the host computer must be configured for 8 bit data at no parity, with 1 stop bit. The
              baud rate should match the selected baud rate parameter on the SSPA unit.
              Selection between the RS-232 and RS-485 interface depends on the state of pin D of the J4 M&C connector. Connect pins D
              and d to select RS232 interface. Otherwise SSPA will operate in RS485 mode.
              The unit will only respond to properly formatted protocol packets. The basic communication packet is shown in Figure 2. It
              consists of a Header, Data, and Trailer sub-packet.
              Header Sub-Packet
              The Header packet is divided into three sub-packets which are the Frame Sync, Destination Address and Source Address
              packets (See Figure 3).
              Destination Address
              The destination address field specifies the node for which the packet is intended. It may be an individual or broadcast
              address. The broadcast address is 0xAA. This is used when a packet of information is intended for several nodes on the
              network. The broadcast address can be used in a single device connection when the host needs to determine the address of
              the amplifier. The amplifier will reply with its unique address.
              Source Address
              The source address specifies the address of the node that is sending the packet. All unique addresses, except the broadcast
              address, are equal and can be assigned to individual units. The host computer must also have a unique network address.
              Data Sub-Packet
              The data sub-packet is comprised of 6 to 32 bytes of information. It is further divided into seven (7) fields as shown in Figure
              4. The first six (6) fields comprise the command preamble while the last field is the actual data.
                                                                        3 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
              Protocol ID
              This field provides backward compatibility with older generation equipment protocol. It should normally be set to zero (0).
              This field allows the amplifier to auto-detect other protocol versions, which may exist in the future.
              Request ID
              This is an application specific field. The amplifier will echo this byte back in the response frame without change. This byte
              serves as a request tracking feature.
              Command
              The SSPA protocol is a table based protocol. It allows the user to view and modify data tables located on the controlled
              device. Throughout the remainder of this description, "sender" will refer to the host PC, and "receiver" will refer to the SSPA
              unit.
              Sender and receiver are limited to two commands and two command responses. The Get Request command issued by a
              command sender allows monitoring of existing conditions and parameters on the receiver. The Get Request frame should
              not have any bytes in the Data Filed and be no longer than 11 bytes.
              The Response frame from the receiver will contain a Get Response designator in the Command field. If the receiver does not
              detect any errors in the Get Request frame, the requested data will be attached to the response frame. The length of the Get
              Response framevaries by the amount of attached data bytes. It may contain 11+N bytes where N is the amount of requested
              data bytes from a particular table, specified in Data Length field.
              The Set Request command allows the sender to actively change parameters for the receiver's internal configuration. The Set
              Request frame must contain a number of bytes in the Data Field as specified in Data length field. The frame size must be
              11+N bytes, where N is the length of the attached data structure. The receiver will respond with a frame where the command
              field will be set to a Set Response designator. The frame length is equal to the Request frame. The byte value for each
              command is given in Table 4.
              Data Tag
              The SSPA internal structure is organized in several tables, all of which share similar functionality and internal resources. To
              access the various tables, the data tag must be specified in the request frame. The data associated with certain tags is read
              only. Therefore only the "Get" command request would be allowed to access these data tags. The SSPA will return an error
              on attempts to issue a "Set" request to a read-only table tag. Various tables may contain values formatted either in 1 or 2
              bytes format. See Table 5.
                                  Byte      Field
                 Tag Name                                                                  Description
                                  Value    Length
                                                         This tag allows accessing various system settings on remote unit. Host access
                  System
                                    0       1 byte    status: Full Read/Write access. Settings can be modified at any time. Some settings
                Settings Tag
                                                                      may require hardware reset of the remote SSPA unit.
                                                                        4 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
                  System                                 This tag allows access to the critical unit thresholds. Consult the factory before
                                    1      2 bytes
               Threshold Tag                                                     changing any of these settings.
                                                       This tag allows access to the unit's internal conditions flags, such as fault status or
                  System
                                    3       1 byte    current system status. Host access status: Read only. This type of data cannot be set
               Conditions Tag
                                                                                      or modified remotely.
                ADC Channel                            This tag allows access to the unit's internal Analog to Digital converter. Host access
                                    4      2 bytes
                 Access Tag                                  status: Read only. This type of data cannot be set or modified remotely.
              Packet Wrapper        6       1 byte                          This tag is not used in CO SSPA protocol.
                  Reserved         2,5         N/A                         These tags are reserved for factory use only.
                      Important! In the Response, the Frame Data Address field is replaced with the Error Status information.
                     The various error codes are given in Table 6.
                                         Byte
                Error Code Name                                                         Possible Cause
                                         Value
                    No Errors              0                                  Normal condition; no errors detected.
               Data Frame Too Big          1                    Specified Data length is too big for respondent buffer to accept.
                  No Such Data             2                       Specified Data Address is out of bounds for this tag data.
                    Bad Value              3                        Specified value not suitable for this particular data type.
                    Read Only              4                       Originator tried to set a value which has read only status.
                 Bad Checksum              5                        Trailer checksum not matched to calculated checksum.
                 Unrecognizable                        Error presented in originator frame, but respondent failed to recognize it. All data
                                           6
                     Error                                                                  aborted.
              Data Length
              This byte value specifies the number of bytes attached in the Data Field. For the Get command, it specifies the number of
              data bytes that have to be returned by the SSPA unit to a host PC in the Response frame. For Set commands, the value of
              this byte specifies the number of data fields to be accessed starting from the address specified in the Data Address byte. In
              general, the Data Length value plus the Data Address must not exceed the maximum data size particular tag.
              Data Field
              The actual data contained in the packet must be placed in this field. The "Get Request" type of command must not contain
              any Data Field. Any "Get Request" will be rejected if any data is present in the Data Field. Generally, the Bad Checksum
              error code will be added to the response from the amplifier if the word size of the information is 16-bits or 2-bytes. Each data
              word is placed in the frame with its least significant byte first. All data with length of 2 bytes must be represented as integer
              type with maximum value range from 32767 to (-32767).
              Trailer Sub-Packet
              The trailer component contains only one (1) byte called the Frame Check Sequence, shown in Figure 6. This field provides a
              checksum during packet transmission.
                                                                         5 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
              Frame Check
              This value is computed as a function of the content of the destination address, source address and all Command Data
              Substructure bytes. In general, the sender formats a message frame, calculates the check sequence, appends it to the
              frame, then transmits the packet. Upon receipt, the destination node recalculates the check sequence and compares it to the
              check sequence embedded in the frame. If the check sequences are the same, the data was transmitted without error.
              Otherwise an error has occurred and some form of recovery should take place. In this case the amplifier will return a packet
              with the "Bad Checksum" error code set. Checksums are generated by summing the value of each byte in the packet while
              ignoring any carry bits.
              Timing issues
              There is no maximum specification on the inter-character spacing in messages. Bytes in messages to amplifier units may be
              spaced as far apart as you wish. The amplifier will respond as soon as it has collected enough bytes to determine the
              message. Generally, there will be no spacing between characters in replies generated by unites. The maximum length of the
              packet sent to the amplifier node should not exceed 64 bytes, including checksum and frame sync bytes. Inter-message
              spacing must be provided for good data transmission. The minimum spacing should be 100 ms. This time is required for the
              controller to detect a "Line Cleared" condition with half duplex communications. Maximum controller respond time is 200 ms.
                                                                      6 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
              Table 7 outlines the request frame structure for the system amplifiers. Table 8 outlines the response frame structure for the
              system amplifiers.
                                                                        7 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
              Table 9 outlines the amplifier settings data values. Table 10 shows the amplifier condition data values. Table 11 describes the
              amplifier threshold data values.
The firmware version where a feature first became available is listed in parentheses in the following tables.
                Data        Length
                                            Description                                    Limits and Valid Values
               Address      (Bytes)
                                         System Operational       255 = Single Amplifier; 0 = 1:1 Redundant Mode; 1 = Dual 1:1 Redundant
                   1           1
                                          Mode Designator                     Mode (v. 3.60); 2 = Maintenance Switch (v. 6.00)
                                         System Hierarchical
                   2           1                                                           0 = HPA 1; 255 = HPA 2
                                              Address
                                        Unit Start Up State (in
                   3           1                                                  0 = Standby Amplifier; 1 = Online Amplifier
                                            Redundancy)
                   4           1             Mute State             0 = Mute Set (Transmit Disable); 255 = Mute Clear (Transmit Enable)
                                          Attenuation Level
                   5           1        (down from maximum         0 = 0 dB attenuation; 200 = 20.0 dB attenuation; [1 bit for every 0.1 dB]
                                                gain)
                                        Module Gain Control       0 = External Analog Voltage Gain Control; 1 = ALC Control (v. 6.40); 255
                   6           1
                                             Authority                                   = Serial Port Gain Control
                                          Amplifier Network
                   7           1                                                             Valid Values: 0 - 255
                                             Address
                                          High Temperature
                   8           1                                    Valid Values: 0 - 125 (in °C); Consult factory before changing setting
                                          Alarm Threshold
                                           SSPA Module
                   9           1                                                   Reserved for Factory Use; 255 = Default
                                          Calibration Mode
                                          SSPA Spare Fault        0 to 7 = Fault on value of window on ADC channel; 8 = Fault on External
                  10           1
                                              Status                                   Mute; 255 = Ignore Spare Fault
                                          SSPA Spare Fault           0 = Major Fault (triggers Summary fault); 1 = Major Fault with Mute
                   11          1
                                             Handling               (Transmit Disabled); 255 = Minor Fault (no effect on Summary Fault)
                                                                  0 = Fault on Logic High State; 1 = Fault on Logic Low State; 2 = Startup in
                                        SSPA Auxiliary Fault
                  12           1                                   Low Z State; 3 = Startup in High Z State; 255 = Ignore Auxiliary Fault (v.
                                             Status
                                                                                                     3.50)
                                                                     0 = Major Fault (triggers Summary fault); 1 = Major Fault with Mute
                                        SSPA Auxiliary Fault
                  13           1                                  (Transmit Disabled); 2 = Minor Fault with Mute (Transmit Disabled); 255 =
                                            Handling
                                                                             Minor Fault (no effect on Summary Fault) (v. 3.50)
                                                                  0 = Fault on Logic High State; 1 = Fault on Logic Low State; 255 = Ignore
                  14           1          BUC Fault Status
                                                                                                  BUC Fault
                                                                     0 = Major Fault (triggers Summary fault); 1 = Major Fault with Mute
                  15           1         BUC Fault Handling
                                                                    (Transmit Disabled); 255 = Minor Fault (no effect on Summary Fault)
                                                                  0 = Terminal Protocol (v. 6.60); 3 = IPNet (Ethernet UDP + Web M&C); 4
                  16           1           Protocol Select
                                                                                     = SNMP; 255 = Normal Protocol
                  17           1          Baud Rate Select                  0 = 38400; 1 = 19200; 2 = 4800; 3 = 2400; 255= 9600
                                         Reflected RF Fault       0 = Minor Fault; 1 = Major Fault (triggers Summary fault); 255 = Disabled.
                  18           1
                                              Handling                                              (v. 6.05)
                                         Reflected RF Fault
                  19           1                                    Valid Values: 0 - 80 (in dBm; value used as High threshold). (v. 6.20)
                                             Threshold
                  20           1           Standby Mode                           0 = Cold Standby; 1 = Hot Standby (v. 3.50)
                  21           1           BUC Reference                      0 = Autoswitch; 1 = External; 2 = Internal (v. 3.60)
                                                                    0 = Fault on Low RF Fault Threshold; 1 = 10% Forward RF Power
                                          Forward RF Fault
                  22           1                                    Window; 2 = 15% Forward RF Power Window; 3 = Fault on High RF
                                              Status
                                                                                       Threshold; 255 = Disabled
                                                                        8 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
                                                             0 = Major Fault (Triggers Summary fault); 1 = Fault Online Unit Only (v.
                                      Forward RF Fault
                  23          1                             6.30); 2 = Major Fault + Mute (triggers Summary fault, Transmit Disabled)
                                          Handling
                                                                     (v. 6.37); 255 = Minor Fault (no effect on Summary fault)
                                                             Valid Values: 0 - 80 (in dBm; value used as Low, Window center point, or
                                      Forward RF Fault
                  24          1                               High threshold, depending on Forward RF Fault Status - Address 22 -
                                         Threshold
                                                                                               setting)
                                                              0 = Fan Speed Low; 1 = Fan Speed High; 2 = Fan Speed Auto; 255 =
                  25          1       Fan Speed Control
                                                                    Off/Default (RF Level Control). (v. 6.10, GaN units only)
                  26          1          Switch Mute                  0 = Switch Mute On; 255 = Switch Mute Off. (v. 6.54)
                                     Reserved for Factory
                27-28         2                                                       Valid values: 1 - 255
                                            Use
                                    SSPA IP Address Byte
                  29          1                                                       Valid Values: 1 - 255
                                          1 (MSB)
                                    SSPA IP Address Byte
                  30          1                                                       Valid Values: 1 - 255
                                             2
                                    SSPA IP Address Byte
                  31          1                                                       Valid Values: 1 - 255
                                             3
                                    SSPA IP Address Byte
                  32          1                                                       Valid Values: 1 - 255
                                             4
                                    SSPA IP Gateway Byte
                  33          1                                                       Valid Values: 1 - 255
                                             1
                                    SSPA IP Gateway Byte
                  34          1                                                       Valid Values: 1 - 255
                                             2
                                    SSPA IP Gateway Byte
                  35          1                                                       Valid Values: 1 - 255
                                             3
                                    SSPA IP Gateway Byte
                  36          1                                                       Valid Values: 1 - 255
                                          4 (LSB)
                                     SSPA Subnet Mask
                  37          1                                                       Valid Values: 1 - 255
                                       Byte 1 (MSB)
                                     SSPA Subnet Mask
                  38          1                                                       Valid Values: 1 - 255
                                          Byte 2
                                     SSPA Subnet Mask
                  39          1                                                       Valid Values: 1 - 255
                                          Byte 3
                                     SSPA Subnet Mask
                  40          1                                                       Valid Values: 1 - 255
                                       Byte 4 (LSB)
                                     SSPA IP Port Byte 1
                  41          1                                                       Valid Values: 1 - 255
                                           (MSB)
                                     SSPA IP Port Byte 2
                  42          1                                                       Valid Values: 1 - 255
                                           (LSB)
                                    SSPA IP Lock Address
                  43          1                                                       Valid Values: 1 - 255
                                       Byte 1 (MSB)
                                    SSPA IP Lock Address
                  44          1                                                       Valid Values: 1 - 255
                                           Byte 2
                                    SSPA IP Lock Address
                  45          1                                                       Valid Values: 1 - 255
                                           Byte 3
                                    SSPA IP Lock Address
                  46          1                                                       Valid Values: 1 - 255
                                       Byte 4 (LSB)
               Data   Length
                                      Description                                 Limits and Valid Values
              Address (Bytes)
                  1       2       Tempcomp DAC Value                                Valid Values: 0 - 1023
                  2       2       Present Temperature                                       ± 125
                                                                   9 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
                                                               For each bit listed below: (0 = fault clear; 1 = fault set), (0 = mute clear; 1 =
                                                              mute set), (0 = standby state, 1 = online state). Lower Byte (Bit 0 = Summary
                                                               Fault; Bit 1 = High Temperature Fault; Bit 2 = Low DC Current Fault; Bit 3 =
                                                                Low DC Voltage Fault; Bit 4 = External Mute Status; Bit 5 = Internal Mute
                                    Fault, Mute, and State
                  3          2                                Status; Bit 6 = Forward RF Fault; Bit 7 = Reflected RF Fault). High Byte (Bit 0
                                          Conditions
                                                               = Block Up Converter Fault; Bit 1 = Spare Fault; Bit 2 = Auxiliary Fault; Bit 3
                                                                = Reserved; Bit 4 = RF Switch Control 1 state; Bit 5 = RF Switch Control 2
                                                                  state; Bit 6 = Control board configuration (1 = Single control board; 0 =
                                                                          Master/Slave configuration); Bit 7 = Unit On Line State).
                                     Present Attenuation
                  4          2                                     1 bit per 0.1 dB attenuation. Low Byte: 0 - 200; High Byte: always 0
                                           Level
                                     Present RF Power
                  5          2                                      1 value per 0.1 dBm (i.e. 455 = 45.5 dBm). Valid Values: 0 - 1023
                                           Level
                  6          2        SSPA DC Current                            1 value per 0.1 Amp. 200 Amp maximum
                  7          2      Regulator DC Voltage                           1 value per 0.1 volt. 48 volt maximum
                  8          2      Power Supply Voltage                           1 value per 0.1 volt. 60 volt maximum
                                         Transistor Gate
                  9          2                                  1 value per 0.1 volt. ± 10 volt maximum (use 2s complement integer math)
                                             Voltage
                                      SSPA DC Current
                 10          2                                                   1 value per 0.1 Amp. 240 Amp maximum
                                        (Slave Side)
                                    Regulator DC Voltage
                 11          2                                                     1 value per 0.1 volt. 48 volt maximum
                                       (Slave Side)
                                    Power Supply Voltage
                 12          2                                                     1 value per 0.1 volt. 60 volt maximum
                                       (Slave Side)
                                       Transistor Gate
                 13          2       Voltage (Slave Side,       1 value per 0.1 volt. ± 10 volt maximum (use 2s complement integer math)
                                     High Power stages)
                                       Transistor Gate
                 14          2       Voltage (Slave Side,       1 value per 0.1 volt. ± 10 volt maximum (use 2s complement integer math)
                                      Pre-Amp stages)
                                     SSPA DC Current
                 15          2     (Master Side) (v.6.10 or                      1 value per 0.1 Amp. 240 Amp maximum
                                           better)
                                     Reflected RF Power
                                     Level (v.6.20) (Unit
                                    must be equipped with
                 16          2         reflected power              1 value per 0.1 dBm (i.e. 455 = 45.5 dBm). Valid Values: 0 - 1023
                                       monitor option,
                                      otherwise value is
                                          irrelevant)
                        Data Addresses 10 through 14 of Table 10 are valid only for the Master/Slave control board configuration
                      (see System Condition Data Address 3, High Byte, Bit 6).
                 Data             Length
                                                                  Description                               Limits and Valid Values
                Address           (Bytes)
                                                                                                     Minimum value = 0; Maximum value =
                      1*             2            Low Current Fault Threshold (Master Side)
                                                                                                                    1023
                                                                                                     Minimum value = 0; Maximum value =
                      2*             2                 Spare Fault Window, Lower Limit
                                                                                                                    1023
                                                                                                     Minimum value = 0; Maximum value =
                      3*             2                 Spare Fault Window, Upper Limit
                                                                                                                    1023
                                                                                                     Minimum value = 0; Maximum value =
                      4*             2            Low Current Fault Threshold (Slave Side)
                                                                                                                    1023
                                                  Low Regulator Voltage Threshold (Master            Minimum value = 0; Maximum value =
                      5*             2
                                                                   Side)                                            1023
                                                                        10 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
* Consult the factory before changing any system threshold data values.
                      Note: In general, data length must be at least two (2) bytes to form an integer; the lower byte must come
                   first. If an odd number of bytes arrived, the last data byte in the packet will be saved as the lower part of
                   the integer; the upper part will be 0 by default.
                                                                  11 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
This section shows examples of communication exchanges between an Outdoor SSPA unit and a remote PC.
                 Byte
                            Value                                                 Description
                 Count
                    1       0xAA                                              Frame Sync Byte 1
                    2       0x55                                              Frame Sync Byte 2
                    3       0x05                                       Destination Address of SSPA Unit
                    4       0x0A                               Source Address of Request Originating PC Host
                    5       0x00                           Protocol Version Compatibility. Field must always be "0".
                    6       0x6F                   Request ID byte is set by originator, will be echoed back by respondent.
                    7       0x01                                 Command field for "Get" type of the request.
                    8       0x00           "System Settings" tag indicates which data from respondent required in response frame.
                                       Data Address field indicates the starting byte of the selected Data Tag being requested (4 = Mute
                    9       0x04
                                                                                      State).
                   10       0x01        Data Length field indicates the total number of bytes of the selected Data Tag being requested.
                   11       0x84                              Arithmetic checksum of bytes number 3 through 10.
                                                                       12 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
                                                                13 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
                                                               14 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
              The Outdoor SSPA Ethernet Port (J9) supports several IP network protocols to provide a full-featured remote M&C interface
              over an Ethernet LAN.
                     IPNet protocol - Redirection of standard Teledyne Paradise Datacom serial protocol over UDP transport layer
                     protocol. This protocol is fully supported in the Teledyne Paradise Datacom Universal M&C software.
                     SNMPv1 protocol - This protocol is intended for integration into large corporate NMS architectures.
In order to utilize either of the protocols listed above, the relevant interface option has to be turned on.
              Of course, standard IP level functions such as ICMP Ping and ARP are supported as well. There is currently no support for
              dynamic IP settings, all IP parameters.
              IPNet Interface
              Satcom system integrators are recognizing the benefits of an Ethernet IP interface. These benefits include:
              General Concept
              Implementation of the raw Ethernet interface is not practical due to the limitations it places on M&C capabilities by the range
              of a particular LAN. It is more practical to use an Ethernet interface in conjunction with the standard OSI (Open System
              Interconnect) model to carry a stack of other protocols. In an OSI layered stack, an Ethernet interface can be represented as
              a Data Link layer. All upper layers are resolved through a set of IP protocols. In order to keep data bandwidth as low as
              possible (which is important when M&C functions are provided through a low-bandwidth service channel) the IP/UDP
              protocol set is used as the Network/Transport layer protocol on Teledyne Paradise Datacom SSPAs.
              UDP (User Datagram Protocol) was chosen over TCP (Transmission Control Protocol) because it is connectionless; that is,
              no end-to-end connection is made between the SSPA unit and controlling workstation when datagrams (packets) are
              exchanged.
              Teledyne Paradise Datacom provides a Windows-based control application to establish UDP-based Ethernet communication
              with SSPAs. The control application manages the exchange of datagrams to ensure error-free communication. An attractive
              benefit of UDP is that it requires low overhead resulting in minimal impact to network performance. The control application
              sends a UDP request to the SSPA unit and waits for a response. The length of time the control application waits depends on
              how it is configured. If the timeout is reached and the control application has not heard back from the agent, it assumes the
              packet was lost and retransmits the request. The number of the retransmissions is user configurable.
              The Teledyne Paradise Datacom RM SSPA Ethernet IP interface can use UDP ports from 0 to 65553 for sending and
              receiving. The receiving port needs to be specified through the front panel menu. For sending, it will use the port from which
              the UDP request originated. Of course, it is up to the user to select an appropriate pair of ports that are not conflicting with
              standard IP services. Paradise Datacom recommends usage of ports 1038 and 1039. These ports are not assigned to any
              known application.
              As an application layer protocol (which actually carries meaningful data), the standard Teledyne Paradise Datacom RM
              SSPA serial protocol was selected. This protocol is extremely flexible and efficient. It is also media independent and can be
              easily wrapped into another protocol data frame. An example of the UDP frame with encapsulated Teledyne Paradise
              Datacom protocol frame is shown in Figure 6.
A detailed OSI model for the RM SSPA M&C interface is represented in Table 18.
                                                                         15 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
              This set of Ethernet IP protocols is currently supported by the Teledyne Paradise Datacom Universal M&C software package.
              The software is supplied on CD with the unit, or can be download from company's web site, http://www.paradisedata.com.
              Troubleshooting IP Connectivity
              Check IP connectivity to the SSPA unit. To do so on a Windows-based PC, open a Command Prompt window and type the
              following command: PING 192.168.0.9, then press the Enter key. If the unit is successfully found on the network, the request
              statistic will be displayed.
C:\Users\johndoe>ping 192.168.0.9
If this step is successfully completed, a default Ethernet connection is set and ready to use.
              If the unit does not answer on the ping command, check all hardware connections. Consult your network administrator for
              further details.
              SNMP Interface
              SNMP-based management was initially targeted for TCP/IP routers and hosts. However, the SNMP-based management
              approach is inherently generic so that it can be used to manage many types of systems. This approach has become
              increasingly popular for remote management and control solutions for various SSPA systems.
              Teledyne Paradise Datacom devices with Ethernet interface support the most popular SNMPv1 format (SMIv1, RFC1155),
              SNMP Get, SNMP GetNext and SNMP Set commands. SNMP Traps are currently unsupported on units with serial numbers
              below 400000.
              In order to utilize SNMP protocol, the operator has to enable this feature through the front panel or by remote serial protocol.
              SNMP uses the UDP fixed port 161.
              The definition of managed objects described in the Management Information Base (MIB) file. The MIB file is available for
              download from the Downloads section of the Teledyne Paradise Datacom web site, http://www.paradisedata.com.
              Interface
              The Teledyne Paradise Datacom MIB is a table-based MIB, and is the same for all devices. The MIB table is designed to
              follow the same pattern as the tables for serial protocol. For additional information about OID values, refer to Table 11
              through Table 13.
              The text values in the tables help automatic value parsing within NMS or make the values readable through an MIB browser.
              All text value OIDs follow the same pattern:
                                                                        16 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
              As with the serial protocol, the MIB allows access to a remote SSPA (default state) as well as to the RCP unit itself. To switch
              between the MIBs of those devices, the proper Device Type has to be selected (OID -1.3.6.1.4.1.20712.1.4).
              --paradiseDatacom(1.3.6.1.4.1.20712)
                |
                +--deviceINFO(1)
                | |
                | +-- r-n OctetString deviceID(1)
                | +-- rwn OctetString deviceLocation(2)
                | +-- r-n OctetString deviceRevision(3)
                | +-- r-n Enumeration deviceType(4)
                |
                +--devices(2)
                       |
                       +--paradiseDevice(1)
                       | |
                       | +--settings(1)
                       | | |
                       | | +--settingsEntry(1) [settingIndex]
                       | |       |
                       | |       +-- rwn Integer32   settingIndex(1)
                       | |       +-- rwn Integer32   settingValue(2)
                       | |       +-- r-n OctetString settingTextValue(3)
                       | |
                       | +--thresholds(2)
                       | | |
                       | | +--thresholdsEntry(1) [thresholdIndex]
                       | |       |
                       | |       +-- rwn Integer32   thresholdIndex(1)
                       | |       +-- r-n Integer32   thresholdValue(2)
                       | |       +-- r-n Enumeration thresholdStatus(3)
                       | |       +-- r-n OctetString thresholdText(4)
                       | |
                       | +--conditions(3)
                       |      |
                       |      +--conditionsEntry(1) [conditionsIndex]
                       |         |
                       |         +-- rwn Integer32   conditionsIndex(1)
                       |         +-- r-n Integer32   conditionsValue(2)
                       |         +-- r-n Counter     conditionsEventCount(3)
                       |         +-- r-n OctetString conditionsText(4)
                       |
                       +--paradiseDeviceA(2)
                       |
                       +--paradiseDeviceB(3)
                       |
                       +--paradiseDeviceC(4)
                       |
                       +--modem(5)
              deviceID - Octet string type; maximum length -60; field specifies device model and serial number; read only access; OID
              -1.3.6.1.4.1.20712.1.1
              deviceLocation - Octet string type; maximum length 60; field allows customer to store information about device physical
              location or any other textual information related to the device; read/write access; OID -1.3.6.1.4.1.20712.1.2
              deviceRevision - Octet string type; maximum length 60; field specifies device firmware revision; read only access; OID
              -1.3.6.1.4.1.20712.1.3
              deviceType - Enumeration, integer type; field allows simple detection of SNMP device type. Values: rmsspa(1), cosspa(2),
              rcp2fprc(3), rcp21000co(4), rcp21000rm(5), rcp21000rcp(6), buc(7), rbc(8), minicosspa(9); read only access; Setting the ID
              to any other value will default type to cosspa. OID -1.3.6.1.4.1.20712.1.4
                                                                       17 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
Note that both the Compact Outdoor SSPA and High Power Outdoor SSPA use deviceType = 2 (cosspa).
              devices - This field is subdivided into 5 branches: paradiseDevice, paradiseDeviceA, paradiseDeviceB paradiseDeviceC and
              modem. paradiseDevice branch currently is used for all Paradise Datacom LLC SNMP enabled devices except Modem.
              Branches for Devices A, B and C are reserved for future use.
              paradiseDevice - Field contains tables that hold specific device information: Settings, Thresholds and Conditions. All table
              formats follow a common pattern: Index, Value, TextValue. The threshold table has an additional column for parameter
              validation. The conditions table has an extra column for event counters.
              The Index column provides general table indexing; the Value column presents the current value of the relevant parameter;
              the TextValue column provides information about parameter name, measurement units and limits.
              A value of "1" in the validation column of the thresholds table indicates the parameter is valid; a value of "2" indicates the
              parameter is invalid or "Not available".
              The event counter column of the conditions table indicates how many times a value of a relevant parameter changed its state
              since system power-up.
              settings - Table contains current device configuration and provides device management. Read/write access for
              settingsValue column.
thresholds - Table provides information about device internal limits and subsystems info. Read only.
              These units allow independent functioning of two SNMP traps (asynchronous notifications): Fault trap and Conditions trap.
              Both traps can be enabled or disabled by the operator. The operator can also specify how many times the same trap
              notification will be sent back to the SNMP manager.
              The SNMP manager IP address is also selectable by the operator. This IP address must be specified in the relevant OID
              branch.
Every trap message is marked by the fixed trap community string "trap". This community name is not user selectable.
              The Fault trap allows asynchronous notification of the SSPA fault state change. When enabled, trap notification will be sent
              to a manager every time either the summary fault state or a fault type is changed. The Last Fault Time ticks counter will be
              reset each time the summary fault changes its state to "Alarm" or when a new fault condition is detected. This counter also
              resets itself during device power-up. If no faults are present after device power-up, Fault Trap will issue a "Cold Start"
              notification to the manager.
              The Condition Trap allows the unit to generate asynchronous notifications independent from the unit fault state. Currently, the
              following conditions can be used for this trap triggering: Forward RF Level, Reflected RF Level (for units equipped with a
              Reflected RF sensor), DC Current level, PS Voltage level, module plate temperature, LNA current (if an external LNA is
              powered through the SSPA auxiliary power port).
              To enable this trap, set the Condition Trap Resend option to a non-zero value and determine the upper and lower limits for
              the condition window. Window values must be selected according to the relevant selected condition measured by the unit.
              For example: Temperature must be selected in degrees, RF power in tenth of dBms, etc.
              After successful configuration, the SSPA will generate a notification every time the selected condition is outside the selected
              measurement window. For units with multiple measured parameters, the relevant condition location must be selected (i.e.,
              units with two power supplies use 1 for PS1, and 2 for PS2). For other conditions, this value is "don't care".
Both traps will send a "Device Up Time" time stamp with every trap notification.
                                                                        18 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
              --paradiseDatacom(1.3.6.1.4.1.20712)
                |
                +--deviceINFO(1.3.6.1.4.1.20712.1)
                | |
                | +-- r-n OctetString deviceID(1.3.6.1.4.1.20712.1.1)
                | +-- rwn OctetString deviceLocation(1.3.6.1.4.1.20712.1.2)
                | +-- r-n OctetString deviceRevision(1.3.6.1.4.1.20712.1.3)
                | +-- r-n Enumeration deviceType(1.3.6.1.4.1.20712.1.4)
                | |
                | +--deviceTimeTicks(1.3.6.1.4.1.20712.1.5)
                | | |
                | | +-- r-n TimeTicks deviceUpTime(1.3.6.1.4.1.20712.1.5.1)
                | | +-- r-n TimeTicks deviceFaultTime(1.3.6.1.4.1.20712.1.5.2)
                | |
                | +--deviceCounters(1.3.6.1.4.1.20712.1.6)
                | | |
                | | +-- r-n Counter deviceSFaultCounter(1)
                | |
                | +--deviceFaultState(1.3.6.1.4.1.20712.1.7)
                | | |
                | | +-- r-n Enumeration deviceSummaryFault(1)
                | | +-- r-n Enumeration deviceLastFault(2)
                | |
                | +--deviceTrapedCondition(1.3.6.1.4.1.20712.1.8)
                | | |
                | | +-- r-n Integer32 deviceTrappedConditionValue(1)
                | |
                | +--deviceTrapControl(1.3.6.1.4.1.20712.1.9)
                | | |
                | | +-- rwn IpAddress deviceManagerIP(1)
                | | +-- rwn Integer32 deviceFaultsTrapResend(2)
                | | +-- rwn Integer32 deviceConditionTrapResend(3)
                | | +-- rwn Enumeration deviceConditionToMonitor(4)
                | | +-- rwn Integer32 deviceConditionULimit(5)
                | | +-- rwn Integer32 deviceConditionLLimit(6)
                | | +-- rwn Integer32 deviceConditionLocation(7)
                | |
                | +--deviceTraps(1.3.6.1.4.1.20712.1.10)
                | | |
                | | +-- (1.3.6.1.4.1.20712.1.10.0)
                | |
                | +--deviceFaultsTrap(1.3.6.1.4.1.20712.1.10.0.11)
                |     [deviceUpTime,deviceSummaryFault,deviceLastFault]
                | |
                | +--deviceConditionTrap(1.3.6.1.4.1.20712.1.10.0.12)
                |     [deviceUpTime,deviceConditionToMonitor,deviceTrappedConditionValue]
                |
                +--devices(2)
                |
                +--paradiseDevice(1)
                | |
                | +--settings(1)
                | | |
                | | +--settingsEntry(1) [settingIndex]
                | | |
                | | +-- rwn Integer32 settingIndex(1)
                | | +-- rwn Integer32 settingValue(2)
                | | +-- r-n OctetString settingTextValue(3)
                | |
                | +--thresholds(2)
                | | |
                | | +--thresholdsEntry(1) [thresholdIndex]
                | | |
                | | +-- rwn Integer32 thresholdIndex(1)
                | | +-- r-n Integer32 thresholdValue(2)
                | | +-- r-n Enumeration thresholdStatus(3)
                | | +-- r-n OctetString thresholdText(4)
                | |
                | +--conditions(3)
                | |
                | +--conditionsEntry(1) [conditionsIndex]
                | |
                | +-- rwn Integer32 conditionsIndex(1)
                | +-- r-n Integer32 conditionsValue(2)
                | +-- r-n Counter conditionsEventCount(3)
                | +-- r-n OctetString conditionsText(4)
                |
                +--paradiseDeviceA(2)
                |
                                                           19 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
                +--paradiseDeviceB(3)
                |
                +--paradiseDeviceC(4)
                |
                +--modem(5)
deviceFaultTime -- Time elapsed since deviceLastFault last state change in hundredths of second;
              deviceSummaryFault -- Enumerated value of device last detected fault condition. The following enumerated values are
              possible: coldStart(1), overTemp(2), badRegltr(3), lowDCCur(4), aux(5), buc(6), lna(7), hpa(8), lowFwdRF(9), highRefRF(10),
              nPlusOne (11), badPS(12), timeOut(13), other(14), noFaults(15);
deviceFaultsTrapResend -- Defines how many times deviceFaultsTrap will repeat the message. 0 - Disables trap triggering;
deviceConditionTrapResend -- Defines how many times condition trap will repeat the message. 0 - Disables trap triggering
              deviceConditionToMonitor -- Enumerated value. Object defines which condition to trap. The following enumerations are
              possible: fwdRF(1), dcCurrent(2), voltagePS(3), temperature( 4), lnaCur(5), refRF(6);
deviceConditionULimit -- Conditions upper trap limit. Trap will be sent when the condition exceeds this limit.
deviceConditionLLimit -- Conditions lower trap limit. Trap will be sent when condition falls below this limit.
              deviceConditionLocation -- Parameter specifying condition measuring location in device containing multiple location of the
              same type (multiple PS, RF modules, LNAs etc.). Set to 0 for system-wide conditions, 1, ... n for relevant unit. For devices
              with single condition location parameter is "don't care".
deviceFaultsTrap -- Trap fires deviceFaultsTrapResend times when deviceLastFault or deviceSummaryFault state changes.
                                                                       20 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
                                     SpareFaultCheck'ADCCh0-7=0..7,
                10/INTEGER                                                    2.1.1.1.2.10   SSPA Spare Fault Status
                                          Ext.Mute=8,Ignore=255
                                      SpareFaultAction'MajorFault=0,                             SSPA Spare Fault
                11/INTEGER                                                    2.1.1.1.2.11
                                      Fault+Mute=1,MinorFault=255                                   Handling
                                       AuxFaultCheck'LogicHigh=0,                              SSPA Auxiliary Fault
                12/INTEGER                                                    2.1.1.1.2.12
                                         LogicLow=1,Ignore=255                                      Status
                                       AuxFaultAction'MajorFault=0,                            SSPA Auxiliary Fault
                13/INTEGER                                                    2.1.1.1.2.13
                                       Fault+Mute=1,MinorFault=255                                 Handling
                                       BUCFaultCheck'LogicHigh=0,                            Block Up Converter Fault
                14/INTEGER                                                    2.1.1.1.2.14
                                         LogicLow=1,Ignore=255                                        Status
                                       BUCFaultAction'MajorFault=0,                          Block Up Converter Fault
                15/INTEGER                                                    2.1.1.1.2.15
                                       Fault+Mute=1,MinorFault=255                                  Handling
                                    ProtocolSelect'Terminal=0,NDSat=2,
                16/INTEGER                                                    2.1.1.1.2.16        Protocol Select
                                      IPNet=3,SNMP=4,Normal=255
                                  BaudRate'38400=255,19200=1,4800=2,
                17/INTEGER                                                    2.1.1.1.2.17       Baud Rate Select
                                           2400=3,9600=255
                                  RefRFCheck'MinorFault=0,MajorFault=1,                      Field reserved for factory
                18/INTEGER                                                    2.1.1.1.2.18
                                             Disabled=255                                               use
                                                                                             Field reserved for factory
                19/INTEGER           RefRFFaultThreshold(dBm)'0...80          2.1.1.1.2.19
                                                                                                        use
                20/INTEGER     StandbyMode'ColdStandby=0, HotStandby=255      2.1.1.1.2.20        Standby Mode
                                  BUCReference'Autoswitch=0,External=1,
                21/INTEGER                                                    2.1.1.1.2.21        BUC Reference
                                           Internal=2,NA=255
                                  FwdRFCheck'LowRF=0,Window10%=1,
                22/INTEGER                                                    2.1.1.1.2.22   Type of Forward RF Fault
                                    Window15%=2,HighRF=3,Dis=255
                                 RFFaultAction'Major=0,MajorOnlineOnly=1,                        Forward RF Fault
                23/INTEGER                                                    2.1.1.1.2.23
                                         Major+Mute=2,Minor=255                                      Handling
                                                                                                Forward RF Fault
                24/INTEGER           FrwdRFFaultThreshold(dBm)'0..80          2.1.1.1.2.24
                                                                                              Threshold Level (dBm)
                                                                                             Fan Speed Control (GaN
                25/INTEGER    FanSpeed'Low=0,High=1,Auto=2, RFLevelCtrl=255   2.1.1.1.2.25
                                                                                                   units only)
                26/INTEGER              SwitchMute'On=0,Off=255               2.1.1.1.2.26    Switch Mute (Ver 6.54)
                                                                                              Field reserved for future
                27/INTEGER                   Reserved'0..255                  2.1.1.1.2.27
                                                                                                        use
                                                                                              Field reserved for future
                28/INTEGER                   Reserved'0..255                  2.1.1.1.2.28
                                                                                                        use
                                                                                              Device IP address byte1
                29/INTEGER                IPAddressByte1'0..255               2.1.1.1.2.29
                                                                                                       (MSB)
                30/INTEGER                IPAddressByte2'0..255               2.1.1.1.2.30    Device IP address byte2
                31/INTEGER                IPAddressByte3'0..255               2.1.1.1.2.31    Device IP address byte3
                                                                                              Device IP address byte4
                32/INTEGER                IPAddressByte4'0..255               2.1.1.1.2.32
                                                                                                       (LSB)
                                                                                             Device Gateway address
                33/INTEGER                IPGateWayByte1'0..255               2.1.1.1.2.33
                                                                                                   byte1 (MSB)
                                                                                             Device Gateway address
                34/INTEGER                IPGateWayByte2'0..255               2.1.1.1.2.34
                                                                                                     byte2
                                                                                             Device Gateway address
                35/INTEGER                IPGateWayByte3'0..255               2.1.1.1.2.35
                                                                                                     byte3
                                                                                             Device Gateway address
                36/INTEGER                IPGateWayByte4'0..255               2.1.1.1.2.36
                                                                                                   byte4 (LSB)
                                                                                             Device Subnet Mask byte1
                37/INTEGER                 IPSubnetByte1'0..255               2.1.1.1.2.37
                                                                                                      (MSB)
                38/INTEGER                 IPSubnetByte2'0..255               2.1.1.1.2.38   Device Subnet Mask byte2
                39/INTEGER                 IPSubnetByte3'0..255               2.1.1.1.2.39   Device Subnet Mask byte3
                                                               21 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
                                                                   22 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
The Protocol setting in the Settings tab of the Universal M&C needs to be set to SNMP, as shown in Figure 8.
                                                                     23 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
Set the desired IP address, Subnet mask and Gateway parameters in the IP Settings tab. See Figure 9.
              The unit will continue to use its default parameters until the unit is reset. To make the new parameters active, reset the
              Outdoor SSPA by removing its AC power. Unplug the Quick Start cable from the M&C connector. (If the unit is restarted with
              the Quick Start cable connected, it will always come up with default IP settings). Apply power to the SSPA. Re-plug the Quick
              Start cable into J4, and check connectivity with the custom IP settings.
              If the custom IP settings will be used in normal operation, the user must construct an IP cable or modify the Quick Start cable
              by disconnecting the interface control pins (pins j and e, Baud Select 0 and Baud Select 1) from ground. In this configuration,
              the SSPA will always use the saved communication control settings rather then rolling back to the default configuration.
                                                                       24 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
              1. Copy the provided Paradise Datacom LLC MIB file into the GetIF Mibs subfolder.
              2. Start the GetIF application.
              3. Select the unit IP address and community strings in the relevant text boxes on the Parameters tab (see Figure 10) and
              then click the Start button.
              4. Select the MBrowser tab.
              5. Click on 'iso' main entity on the MIB tree, then click the Start button.
              6. See update data in output data box (Figure 11).
              Select settingValue.5 entity (SSPA Mute), set the value to 1 and click the Set button.
              7. Observe the Mute state on the SSPA change to a "Mute On" state. See Figure 14.
              A SNMP-managed network consists of three primary components: managed devices, agents, and management systems. A
              managed device is a network node that contains a SNMP agent and resides on a managed network. Managed devices
              collect and store management information and use SNMP to make this information available to management systems that
              use SNMP. Managed devices include routers, access servers, switches, bridges, hubs, computer hosts, and printers.
              An agent is a software module that has local knowledge of management information and translates that information into a
              form compatible with SNMP: the Management Information Base (MIB). The agent can send traps, or notification of certain
              events, to the manager.
                                                                     25 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
              A manager is a software module that listens to the SNMP notifications sent by SNMP agents. The manager can also send
              requests to an agent to collect remote information from the Management Information Base (MIB).
              The communication between the agent and the manager uses the SNMP protocol, which is an application of the ASN.1 BER
              (Abstract Syntax Notation 1 with Basic Encoding Rules), typically over UDP (for IP networks).
                    Version 1 (SNMP V1, described in RFC 1157) is the initial implementation of SNMP.
                    Version 2 (SNMP V2c, described in RFC 1902) is the second release of SNMP. It provides additions to data types,
                    counter size, and protocol operations.
                    Version 3 (SNMP V3, described in RFC 2271 through RFC 2275) is the most recent version of SNMP.
SNMP V1
              SNMP version 1 (SNMPv1) is the initial implementation of the SNMP protocol. SNMPv1 operates over protocols such as
              User Datagram Protocol (UDP), Internet Protocol (IP), OSI Connectionless Network Service (CLNS), AppleTalk Datagram-
              Delivery Protocol (DDP), and Novell Internet Packet Exchange (IPX). SNMPv1 is widely used and is the de-facto network-
              management protocol in the Internet community.
              The Teledyne Paradise Datacom SSPA family of products utilizes the most popular implementation, SNMP V1 over UDP
              transport layer.
SNMP V2
              SNMPv2 (RFC 1441-RFC 1452) revises version 1 and includes some improvements in the areas of performance, security,
              confidentiality, and manager-to-manager communications. It introduced GetBulkRequest, an alternative to iterative
              GetNextRequests for retrieving large amounts of management data in a single request. However, the new party-based
              security system in SNMPv2, viewed by many as overly complex, was not widely accepted.
              The format of the trap message was also changed in SNMPv2. To avoid these compatibility issues, the trap mechanism was
              not implemented in the Paradise Datacom SSPA MIB.
SNMP V3
              Although SNMPv3 makes no changes to the protocol aside from the addition of cryptographic security, it looks much different
              due to new textual conventions, concepts, and terminology. SNMPv3 primarily added security and remote configuration
              enhancements to SNMP.
Problems with implementing SNMP V2 and V3 in Teledyne Paradise Datacom SSPA product family
              Many embedded controllers and microprocessors that are used in electronic components such as amplifier modules do not
              have support for SNMP V2 or V3. This is due to the extensive memory resources required by the computation intensive
              cryptographic security of SNMP V3.
              For this reason V3 has not gained widespread support amongst embedded MCU platform manufacturers. Existing port
              implementations are limited to very powerful ARM5 or above cores, running under full-scale OS systems (Linux, Android,
              etc.). At large, these configurations require external bulk RAM/FLASH to operate. This requirement ultimately affects the
              minimum device startup time (tens of seconds, due to the large boot BIOS) and working temperature range (mostly indoor).
                                                                     26 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
                      Traps are often preferred even though they are less reliable
                      because informs consume more resources in the device and in
                      the network. Unlike a trap, which is discarded as soon as it
                      is sent, an inform must be held in memory until a response
                      is received or the request times out. Also, traps are sent
                      only once, whereas an inform may be resent several times.
                      The retries increase traffic and contribute to higher
                      overhead on the network. Use of traps and informs requires
                      a trade-off between reliability and resources. If it is
                      important that the SNMP manager receives every notification,
                      use informs, but if traffic volume or memory usage are
                      concerns and receipt of every notification is not required,
                      use traps.
Copied from SNMP Configuration Guide, Cisco IOS XE Release 3SE, 3 September 2019.
                                                                27 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
              The Teledyne Paradise Datacom Outdoor SSPAs utilize Terminal Mode Serial Protocol (TMSP) as a secondary serial
              protocol for management and control through a remote serial interface.
              TMSP allows the user to access internal SSPA functions via a remote ASCII Terminal or its equivalent (such as
              HyperTerminal for Windows). TMSP is accomplished through either the RS-232 or RS-485, half duplex, serial communication
              link. US ASCII encoded character strings are used to represent commands and data massages.
              A remote terminal or controller initiates a communication session and the SSPA Terminal takes action and returns a report of
              requested status. The SSPA terminal will not initiate communication and will transmit data only when commanded to do so.
              Prior to establishing the session with the SSPA Terminal, this mode must be enabled through the Universal M&C menu.
              The remote terminal must be configured with serial settings that match the SSPA's serial port settings. For example, if the
              SSPA is set at 9600 Baud, the remote terminal must be also configured as ASCII terminal at 9600 Baud, no parity, 8 bit data
              with 1 stop bit serial connection. The SSPA will not echo back any incoming characters, so local echo must be enabled on
              the remote terminal.
              To establish a remote control session with the SSPA terminal, the user must type "UNIT#XXX" in the terminal window (all
              letters must be in upper case), where XXX is the SSPA unique network address or the global call address (170). Press the
              "Enter" key on remote terminal keyboard.
              The SSPA should answer with "Unit#XXX OnLine", with the first menu screen on the following lines. After a remote session is
              successfully established, the unit will stay connected as long as needed. The session interface is organized into menu
              screens.
              To help the user navigate through the menu, the help string with the list of active keys always follows the menu strings. For
              example, the last transmission string on all informative menu screens will be:
              Active Keys:(U)p+Enter;(D)own+Enter;(C)lrearFlt;(M)enu+Enter;(E)nd+Enter.
To refresh the current screen on the remote terminal, press the "Enter" key. To end a session, press "E" and the "Enter" key.
                     Important! If multiple SSPA units are networked on the same serial link, do not establish a session with
                    more than one SSPA at a time. If you do so you will not get any valid answer from any SSPA!
                                                                       28 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
              At the beginning of the session, the SSPA will prompt the user with the first menu of the Informative sublevel. The user can
              access the Main menu from any informative sublevel by sequentially selecting the "M" and "Enter" keys on the remote
              terminal keyboard.
There are five main levels of the menu selection, shown below:
                    Attenuation - SSPA current level of attenuation, measured in dB (Atten.(dB):XX.X) with an accuracy of 0.1 dB;
                    Alarms - Summary alarm presence, "FAULT!" or "None" will be displayed de-pending on the state of the SSPA;
                    Forward RF Power - Displayed in dBm with accuracy of 0.1 dBm;
                    Reflected RF Power - Displayed in dBm with accuracy of 0.1dBm (if equipped).
                    BUC - Displays the block upconverter (BUC) fault (if equipped). Values "Fault" or "Normal";
                    Aux - Displays the auxiliary fault condition. Values - "Fault" or "Normal";
                    Int.Mute - Displays the internal mute condition (mute state controlled by internal SSPA hardware, such as serial
                    protocol command or automatic over temperature shutdown). Values - "Off" or "On";
                    Ext.Mute - Displays the external mute condition (Mute condition controlled by hardware jumper on M&C
                    connector). Values - "On" or "Off";
                    State - Displays the SSPA online state in a redundant system. Value - "Standby" or "Online";
                    Ctrl - Displays the type of attenuation control. Values - "Analog" or "PC Ctrl".
                    DCCur.(A) - The total DC current draw by the RF module from the main power supply with an accuracy of 0.1A.
                    This value varies depending on the power level of SSPA. If the SSPA is in the mute state, the current drops to a 0
                    to 5A range.
                    Regul.(V) - Displays the measured value of the internal RF module voltage regulator. The value in normal mode
                    should be range from 8 to 10.5V. During SSPA mute period, this value drops to near 0V. Measurement is accurate
                    to within 0.1V.
                    Gate (V) - This value represents the negative GaAsFETs gate drive voltage. Normal value range is 1 to 6 V. The
                    value reading may be affected by SSPA temperature changes and mute state.
                    PS (V) - Displays the internal power supply voltage output. Normal range is 11 to 13 V, with an accuracy to within
                    0.1V.
                    Temp(C) - Current base plate temperature, measured in Centigrade.
                                                                          29 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
This page displays the SSPA serial communication and redundancy related settings.
                    Prtcl. - Displays the type of default implemented serial protocol. Values: Normal, Terminal, IPNet or SNMP.
                    Baud - Displays the default SSPA baud rate. Values: 2400, 4800, 9600, 19200, 38400.
                    Addrs - Displays the SSPA serial network address. Values: 0 to 255.
                    Unit - Displays the SSPA 1:1 redundancy topological factor. Values: "HPA1" or "HPA2".
                    Mode - Displays the implemented redundancy mode. Values: "Standalone", "1:1" or "SinglSw".
                    BUCLock - Displays current setting for internal BUC (if equipped) reference locking mechanism. Possible values:
                    Ext for external reference only, Int for internal reference only and Auto for auto switching function between external
                    and internal reference.
                    StdbyMode - Displays current setting for type of redundancy standby function. Possible values: Cold or Hot.
                    Spare - spare fault can reflect various fault conditions and events.
                    RecordHighT(C) - Displays highest recorded baseplate temperature endured by the SSPA unit.
                    1.Protocol - Selection allows user to select remote communication protocol. Nor-mal, Terminal, IPNet, SNMP or
                    NDSat protocol selections are available. Refer to protocol description section for details. The factory default
                    protocol is "Normal".
                    2.Baud - This item allows the user to select the desired baud rate for serial communication. Available baud rates
                    include 2400, 4800, 9600, 19200 and 38400 Baud. The factory default baud rate is 9600.
                    3.Address - This selection allows the user to set the network address of the controller if used on a serial network.
                    Choose from 1 to 255. The address 170 should not be selected; it is reserved for factory use.
                    4.IP Setup - Selection allows user to set up IP network parameters: IP address, Subnet, Gateway. As well as set
                    and review web page password and various SNMP settings.
                    1.Info - Displays the unique SSPA ID tag as well as the firmware version of the controller card.
                    2.SysMode (System Mode) - Allows the user to select the SSPA redundancy mode. Choose Standalone,1:1, Dual
                    1:1 or Maintenance switch modes.
                    3.GainCtrl (Gain Control) - Menu selects the style of SSPA attenuation control. User may select between "Analog",
                    "Serial" and "ALC" types of control. It also allows set ALC RF level when unit setup for ALC control mode.
                    4.Attenuation - Allows the user to set the SSPA attenuation level between 0 and 20 dB in steps of 0.1dB. In order
                    to take effect, the SSPA must be configured for "Serial" type of attenuation control.
                    5.Mute - Selects the SSPA mute state. Selection values: "On" or "Off".
                    1. Aux. Action - Allows the selection of the final effect of the auxiliary fault on an SSPA operation. Selection: Fault
                    (Major Fault), Fault + Mute, Alert (Minor Fault), or Alert + Mute.
                    2. Aux. Check - Allows the user to select the fault-triggering event. Logic High - fault occurs on "open" unconnected
                    state of auxiliary input line. Logic Low - fault occurs on "close" shorted to ground state of the auxiliary input line.
                    Ignore - allows user to disable auxiliary fault checking.
              Redundancy Sub-Menu
              This menu allows user to select various settings related to SSPA redundancy operation.
                    1.Standby Select - Allows selecting Standby/Online modes for units operating in redundancy system
                    2.Standby Mode - Sets Cold or Hot standby operation for SSPA unit
                    3.Unit - Allows selecting redundancy topological factor: HPA1 or HPA2
              Options Sub-Menu
              This menu makes available functions to backup or restore settings.
                                                                       30 of 31
Outdoor SSPAs, Remote Control Protocol (216595-7)
                                                                                 31 of 31
THIS PAGE LEFT INTENTIONALLY BLANK
Outdoor SSPAs, Performance Tests (216595-8)
                                                                                 1 of 5
Outdoor SSPAs, Performance Tests (216595-8)
              This section describes some of the tests performed on production amplifiers before shipment. Where possible, Teledyne
              Paradise Datacom maintains computer automated RF test stations to ensure a high level of accuracy and consistency to
              production amplifier testing.
              Standard Tests
              All Teledyne Paradise Datacom Outdoor amplifiers must meet rigid specifications and undergo the following tests. Copies of
              the final test data are shipped along with the unit and/or system. Figures 1 through 3 show examples of the final test data for
              a 140W C-Band Compact Outdoor amplifier with an integrated block up converter.
              Swept Gain
              The amplifier gain is swept over the operating frequency range under small signal conditions to confirm the minimum gain
              and gain flatness specifications. The entire outdoor amplifier is tested in a temperature chamber from -40 °C to +55 °C and
              the gain is recorded. See Figure 1, item [1].
              Spurious
              Spurious signals are undesirable byproducts of amplifiers caused by nonlinearities within the amplifier and other system level
              components such as switch mode power supplies. These unwanted signals cause signal management problems in system
              applications. Out-of-band spurious signals cause interference to other pieces of equipment. See Figure 1, item [2].
                                                                         2 of 5
Outdoor SSPAs, Performance Tests (216595-8)
              Intermodulation Distortion
              Intermodulation distortion is one of the most important characteristics of a Solid State power amplifier system. Satellite
              communication systems must comply to certain distortion levels depending on the service involved. All production amplifiers
              are subjected to automated intermod testing. This is based on a standard two-tone intermod test in which the intermod level
              (IMD) is measured in dBc with respect the main tones and the highest third order intermod products.
              Satcom amplifiers are typically used in some 'back-off' condition. This is the operating point at which the composite output
              power is 'backed-off' from the amplifier's P1dB, compression point. A curve of back-off vs. IMD level is especially useful in
              the selection of a power amplifier or determining the proper output power setting in a Satcom system.
              Teledyne Paradise Datacom recognizes the importance of this back-off characteristic and provides a plot of back-off vs. IMD
              from 1 dB to 10 dB back from the amplifier's compression point. Figure 2, item [3], shows a typical back-off curve from a
              production test set.
              Power Requirements
              This test measures the power requirements of the unit over the various voltages appropriate for the unit under test. See
              Figure 3, item [1].
                                                                         3 of 5
Outdoor SSPAs, Performance Tests (216595-8)
Figure 3: M&C, Output Power, Ground, Phase Lock and Misc. Data
              Earth Ground
              This test measures the leakage current and verifies that each pin on J8 is connected correctly. If the ISO/GND compatibility
              jumper is equipped, it verifies the jumper position. See Figure 3, item [1].
              Sample Port
              The RF Sample Port is measured at discrete frequencies across the band and a calibration label is placed near the Type N
              connector on the bottom of the unit. The sample port is approximately -40 dB from the RF output level. A label with the exact
              coupling ratio is attached to the amplifier chassis. See Figure 3, item [2].
              As the input power increases, the output power limits to some maximum level. This is defined as the saturated output power
              or Psat. The Psat specification is a typical value and is not guaranteed. This is due to the variation that exists among
              microwave power semiconductors. The saturated output power is typically 0.5 dB to 1.0 dB above the P1dB value. See
              Figure 3, item [3].
              I/O Test
              This test verifies that the unit has the correct wiring on the MS connectors by testing faults, communications, and
              redundancy. See Figure 3, item [4].
              Reference Lock
              This test checks the external/internal references (if equipped), as well as lowest locking level at 10 MHz. See Figure 3, item
              [5].
FSK
                                                                         4 of 5
Outdoor SSPAs, Performance Tests (216595-8)
Verifies FSK communication with the zBUC. See Figure 3, item [6].
              Phase Noise
              Tests phase noise using external and internal (if equipped) references. The unit is required to meet at each decade, as well
              as fall below the spec line determined by the decades. See Figure 2, item [4].
              Microphonics
              A spectrum analyzer is connected to the unit and is set to perform a max hold on the trace. A vibration is introduced to the
              unit, and the sidebands must meet the specification of ≤ -20 dBc.
              Optional Tests
              The following tests are performed on units at the request of the customer, usually to verify specific customer requirements.
              Noise Figure
              Using a noise figure meter, the unit is tested to verify it operates within specification.
              Group Delay
              The testing software measures the linear, parabolic, and ripple components to verify the unit is within specification.
              AM/PM
              The testing software measures the slope of the amplifier's insertion phase vs. output power.
              Noise Power
              Noise power is the total noise per bandwidth at the output of the unit when a signal is not present.
              Harmonics
              The testing software measures the 2nd and 3rd harmonics of the unit (as long as the frequency range is within the
              capabilities of the equipment).
                                                                                       5 of 5
THIS PAGE LEFT INTENTIONALLY BLANK
Unit Control with Universal M&C Software (216594-2)
                                                                                 1 of 44
Unit Control with Universal M&C Software (216594-2)
              This section describes the control of a remote unit using Teledyne Paradise Datacom's free Windows-based Universal
              Monitor and Control software.
                                                                     2 of 44
Unit Control with Universal M&C Software (216594-2)
              Teledyne Paradise Datacom provides a free version of its Universal Monitor and Control (M&C) Software available for
              download from its web site. Install the software on a PC running Windows 7 or later.
Navigate to the Support > Downloads page and click on the latest version of the sofware to download the zip file.
              Unzip the package and run the setup.exe file. This launches the Universal M&C Software installer. Follow the prompts and
              agree to the license agreement to install the application. When complete, close the installer.
                      By default the installer saves the software to C:\Program Files (x86)\Paradise Datacom. When running
                    the installer, you can change the destination of the installation.
The software may be used to remotely monitor and control any of the following Teledyne Paradise Datacom products:
• System Controllers
                                                                       3 of 44
Unit Control with Universal M&C Software (216594-2)
              Launch the Teledyne Paradise Datacom Universal M&C software from the Programs Menu of your PC. During installation, a
              shortcut to the software may have been added to your desktop.
              To add a new rack mountable amplifier, click the 'Action' menu and select 'Add Unit' from the pull-down menu. Select
              'Rackmount' from the menu choices. See Figure 1.
Figure 1: Universal M&C > Action > Add Unit > Rackmount
Enter a Unit ID (not required although it is recommended). If a Unit ID isn't entered the Unit ID will be assigned by the M&C.
To add a unit connected to a serial port you must supply a Port and a Baud Rate. See Figure 2.
Figure 2: Select a COM Port and Baud Rate for Serial COMs
To add a unit connected via UDP (TCP/IP) you must supply either a Hostname or an IP Address. See Figure 3.
                                                                        4 of 44
Unit Control with Universal M&C Software (216594-2)
              Specify the Unit's unique address in the Amplifier Address box. If you don't know the address of the unit you may search for
              it. Be aware that this search feature is only useful when you have only one unit connected to your PC at a time.
              Choose a log file location by clicking the 'Browse...' button. The default is the "My Documents" folder. The log file name will
              be the UnitID and the extension ".log" appended to it. i.e. "Unit1.log".
              Click on the 'Create' button to connect to the unit. The Universal M&C software will open a new window from which you can
              control and review the status of the connected unit.
                                                                         5 of 44
Unit Control with Universal M&C Software (216594-2)
• Status Tab
• Settings Tab
• Faults Tab
• IP Setup Tab
• SNMP Tab
              Status Tab
              The first screen is the "Status" tab, shown in Figure 4. The Status tab shows the current conditions (or state) of the
              connected SSPA. In addition, the Status tab allows the operator to change the Mute state of the carrier and allows
              adjustment of the on-board attenuator for gain control.
              Settings Tab
              The second screen is the "Settings" tab, shown in Figure 5. It shows the user all available settings on the SSPA. All user-
              adjustable settings are allowed to be modified to suit the specific needs of the customer. However, it should be noted that the
              SSPA is configured for the customer at the factory.
              If modification of any settings is necessary, details of each setting, condition and threshold are available in the Settings,
              Conditions and Thresholds description of the Remote Control Protocol section of any rack mountable amplifier manual.
                                                                        6 of 44
Unit Control with Universal M&C Software (216594-2)
              If the amplifier will be configured in a redundant system and controlled with an external controller, each system amplifier
              should be set to Standalone Mode.
              If the amplifier will be configured in a redundant system but will be controlled using internal control logic, each system
              amplifier should be set to the appropriate redundant mode. All amplifiers in the redundant system should be set to the same
              mode.
              For more information on settings used for internal 1:1 redundancy mode, see the Internal 1:1 Redundant System
              Operation section.
              For more information on settings used for internal 1:2 redundancy mode, see the Internal 1:2 Redundant System
              Operation section.
                                                                        7 of 44
Unit Control with Universal M&C Software (216594-2)
              Select a baud rate of 2400, 4800, 9600 (the default), 19200, or 38400. The operator will be asked to verify any to change to
              the Baud Rate setting. Communication with the amplifier may be affected.
RF Switch Fault Handling settings include Ignore, Minor Fault, Major Fault, and Switchover Mute.
Auxiliary Fault Handling settings include Ignore, Minor Fault, Major Fault, Minor Fault with Mute, and Major Fault with Mute.
              Forward RF Fault Handling settings include Ignore, Low RF Major Fault, Low RF Minor Fault, ALC On, High RF Major Fault,
              High RF Minor Fault, and High RF Major Fault with Mute.
High Reverse RF Fault Handling settings include Ignore, Major Fault, and Minor Fault.
The user can also set the threshold levels for Forward RF and High Reverse RF.
Faults Tab
                                                                          8 of 44
Unit Control with Universal M&C Software (216594-2)
              The third screen is the "Faults" tab, shown in Figure 6. It shows the user the status of all faults on-board the SSPA. These
              include: Summary, Module # faults, Standby State (green = Online; red = Standby); Power Supply, Low DC Voltage and
              Current, Fans, BUC, High Temperature, Forward RF and High Reflected RF, Auxiliary, switch faults (for units configured in a
              redundant system), and optional faults.
              Each RF Module in the SSPA is monitored for faults in addition to the SSPA itself. If the SSPA does not include a module,
              non-existant modules will show up with a status of 'N/A' in the Module Status box, and the indicator will turn yellow.
              IP Setup Tab
              The fourth screen is the "IP Setup" screen, shown in Figure 7. It displays all of the TCP/IP settings on the SSPA.
              When the IP Address is modified, the SSPA must be reset for it to use the new IP Address. Until the SSPA is reset, it will use
              the old IP Address. The Local Port is the port that the SSPA uses for UDP requests. The SSPA also answers requests using
              the same port. If the Local Port is changed, the SSPA must be reset.
                                                                       9 of 44
Unit Control with Universal M&C Software (216594-2)
              The Gateway Address and Subnet Mask are standard settings for TCP/IP communications. If either of these settings is
              changed, the SSPA must be reset for the new settings to take effect.
              The IP Lock Address is used for security. If it is set to something besides 0.0.0.0 or 255.255.255.255 it will only answer the
              address it is set to. For example, if the IP Lock Address is 192.168.0.50, then a request from 192.168.0.100 will not be
              accepted. The IP Lock Address may be changed without resetting the SSPA.
              See the Overview of the PowerMAX M&C section for more information on Master/Slave functions using the N+1 Settings
              Tab.
              SNMP Tab
              The sixth window is the "SNMP Settings" tab, as shown in Figure 8. This screen is used for setting SNMP communication
              parameters, and for assigning trap conditions.
                                                                       10 of 44
Unit Control with Universal M&C Software (216594-2)
                                                              11 of 44
Unit Control with Universal M&C Software (216594-2)
              Launch the Teledyne Paradise Datacom Universal Monitor and Control software from the Programs Menu of your PC. Upon
              installation, a shortcut to the software may have been added to your desktop.
              Click the 'Action' menu and select 'Add Unit' from the pull-down menu. Select 'Compact Outdoor SSPA' from the menu
              choices. See Figure 10.
Figure 10: Universal M&C > Add Unit > Compact Outdoor SSPA
              A new dialog window will open. Enter the following information where applicable: Unit ID; if using a RS-232 Connection, the
              Serial Port and Baud Rate. See Figure 11.
If using an Ethernet Connection, enter the unit's IP Address and Port number. See Figure 12.
                                                                      12 of 44
Unit Control with Universal M&C Software (216594-2)
              Specify the unit's Address in the Amplifier Address box. If you don't know the address of the unit you may search for it. Be
              aware that this search feature is only useful when you have only one unit connected to your PC at a time.
If you wish to change the log file location, click on the 'Browse' button and navigate to the desired location.
Click on the 'Create' button to generate the operation window for this unit.
                                                                        13 of 44
Unit Control with Universal M&C Software (216594-2)
              The operational status, settings and conditions of the connected Compact Outdoor amplifier are displayed in the Universal
              M&C application's four tabs:
• Status Tab
• Settings Tab
• IP Setup Tab
              Status Tab
              The Universal M&C Software will initialize and open to the Status tab, the main monitoring display. See Figure 13. The
              Status tab shows the the current conditions (or state) of the Compact Outdoor SSPA. In addition, the status screen allow the
              user to alter the Mute condition of the carrier and adjust the on-board Attenuator for gain control.
              Upon connection with a unit, the M&C application obtains and displays the unit ID, the amplifier's model number and serial
              number. The SSPA module's firmware version number is also displayed here for convenience.
              The unit's network address and serial COM or IP address are also listed, which can be helpful in optimizing serial
              communications.
              Signal Indicators
              Three rows of indicators show the connection status of the connected amplifier. Top-most is an indicator that displays a
              green square when Connected, or a red square when Disconnected. Immediately below are two indicators for the TX and RX
              paths. The third row displays the mute state (Carrier Enable). The operator may click on the indicator to toggle between
              enabling or muting the amplifier. See Figure 14.
                                                                      14 of 44
Unit Control with Universal M&C Software (216594-2)
                     Summary Alarm: The Summary Alarm is simply a logical 'OR' of any major alarm indicators.
                     Unit Online: This is a status indicator that illuminates green when the unit is online.
                     External Mute Alarm: The External Mute line gives an indication that the SSPA has been externally muted by J4-
                     Pin B. This alarm can be configured to trigger a summary alarm if desired. Factory default is to signal a External
                     Mute fault but no summary alarm.
                     Auxiliary & Spare Alarms: The Auxiliary and Spare Alarms are configurable from the Settings Window.
These alarms can be configured to trigger a summary alarm. See the Settings Tab section.
                     Low DC Current Alarm: The Current Fault is factory preset to alarm if the SSPA module current falls below 60% of
                     its nominal value. This alarm will also trigger a summary alarm.
                     Low DC Voltage Alarm: The Voltage Alarm is factory preset to alarm if the SSPA module current falls below 80% of
                     its nominal value. This alarm will also trigger a summary alarm.
                     High Temperature Alarm: The Temperature Fault indicator is factory preset to alarm at 80°C. The amplifier will
                     continue to operate up to 90°C. Beyond 90°C the DC power will be interrupted to the SSPA module. This measure
                     will protect the sensitive microwave transistors from catastrophic failure. The fans and monitor and control circuitry
                     will continue to operate normally. This function has approximately a 5°C hysteresis window which will allow the
                     amplifier to re-enable itself when the ambient temperature is reduced by 5°C. This alarm will also trigger a
                     summary alarm.
                     Forward RF Alarm: The Forward RF Fault Alarm indicates when the RF output of the amplifier falls below the
                     threshold set in the Settings Window.
                     BUC Alarm: The BUC fault is only active in units that are supplied with an optional L-Band Block Up Converter
                     module. If the Up Converter's phase locked local oscillator loses lock, a BUC alarm is set and the amplifier is
                     muted so that spurious RF cannot be transmitted. This alarm can be configured to trigger a summary alarm.
                     EEPROM Alarm: The EEPROM Alarm is primarily used as a Fiber RX Link alarm for Compact Outdoor SSSPA
                     units configured with a fiber-optic interface.
                     RF Switch Alarms: The RF Switch 1 Alarm is only active if a 1:1 Redundant System has been configured in the
                     M&C program. The RF Switch 2 Alarm is only active is a 1:2 Redundant System has been configured. These
                     configurations are covered in Section 7.
                                                                        15 of 44
Unit Control with Universal M&C Software (216594-2)
              To the left of the thermometer display are several indicators that show various operating conditions of the Compact Outdoor
              Amplifier in real time. These indicators are helpful for any diagnostic procedures and consist of: Power Supply Voltage
              monitor SSPA DC Current monitor Regulator Voltage monitor Gate Voltage monitor.
              The Power Supply voltage indicator displays the primary 12 volt power supply output. SSPA DC Current is the total current
              drawn by the microwave transistors. Regulator Voltage is the DC voltage of the drain circuitry that feeds the GaAs
              transistors. The Gate Voltage indicator monitors the DC voltage of the gate circuitry of the microwave GaAs transistors.
              These indicators provide direct access to the active device operating characteristics.
              The gain can be adjusted by setting the Attenuation Control. An Attenuation Control of 0 dB is the maximum gain (typically
              75 dB) setting on the amplifier. By setting the Attenuation Control to 20 dB; the gain is set to 55 dB. The Attenuation Control
              can be varied using the up/down arrows to the right of the displayed value or by typing a value between 0 and 20 in the field
              and hitting the Enter key.
Units with the reflected power meter option also display the Reflected RF Power. See Figure 18.
              Settings Tab
              Figure 19 shows the Settings tab of the Universal M&C software. The Settings tab contains many of the global settings that
              are available in the SSPA.
                                                                       16 of 44
Unit Control with Universal M&C Software (216594-2)
              The Compact Outdoor amplifier will power up with the "last-state" settings before the unit was powered down. Whatever
              attenuation setting or mute state the amplifier was in when powered down will be the restored settings when the amplifier is
              powered back on.
                                                                       17 of 44
Unit Control with Universal M&C Software (216594-2)
                     Auto - This setting allows the unit to control the cooling fan speed according to the internal RF module
                     temperature. If the module plate temperature remains below 50 °C, the fan speed will be set to minimum. If the
                     registered module plate temperature is above 50 °C, unit will gradually increase the fan speed. Fan speed will
                     reach maximum at a plate temperature of 65 °C.
                     High - This option sets the fan speed to maximum. Air velocity will remain at the same level regardless of other
                     operation parameters.
                     Low - This option sets the fan speed to minimum. Air velocity will remain at the same level regardless of other
                     operation parameters.
                     Default/Off - This setting should be set on units without the fan speed control option. It will allow proper functioning
                     of the RF power monitor analog output. Applying this setting on units with the fan speed control option allows the
                     fan speed to be proportional to the output RF level. Fan speed will be set at the minimum when output RF is below
                     a detectable level. Fan speed will gradually increase when RF output increases within the detectable RF range.
                     Fan speed will be at maximum level when unit reaches saturated power (Psat).
              Click on the Spare Fault Wizard button, which opens a new window. See Figure 20. Select between the following fault
              triggers: Analog Gain Adjust Voltage, Gate Voltage, Regulator Voltage, Power Supply Voltage, SSPA Current, External Mute,
              or None.
                                                                          18 of 44
Unit Control with Universal M&C Software (216594-2)
              Set the range of thresholds (maximum and minimum) that would trigger the selected fault, and configure the fault handling
              via a pull-down menu (Major Fault, Minor Fault, Major Fault plus Mute).
Click the OK button to set the fault trigger for the Spare Fault.
                     Spare/Auxiliary/BUC/Forward RF Fault Handling: Selects whether the associated fault should be a major or minor
                     fault, and whether the fault should mute the unit. A minor fault will trigger a Spare/Auxiliary/BUC/Forward RF Fault
                     alarm but not trigger a Summary Fault. A major fault will trigger both an Spare/Auxiliary/BUC/Forward RF Fault and
                     a Summary Fault.
                     Spare/Auxiliary/BUC Fault Status: Determines if the associated fault input should be ignored or enabled based on
                     the available selections.
                     Forward RF Threshold: Allows the user to assign the threshold at which a Forward RF Fault will be triggered.
                      Take care not to adjust the High Temperature Alarm Threshold within the temperature range of the
                     amplifier's normal operation. Doing so will trigger unneccessary high temperature alarm faults.
              IP Setup Tab
              If the user wishes to set up the networked Compact Outdoor SSPA with custom IP settings, the internal IP settings need to
              be modified. Click on the IP Setup Tab. See Figure 21.
                                                                         19 of 44
Unit Control with Universal M&C Software (216594-2)
              In this window, the user may enter custom IP settings, including the IP Address of the unit, the Gateway Address, the Subnet
              Mask and the Local Port.
              The IP Lock Address allows the operator to set the IP address from which the amplifier will accept requests. This selection
              gives the operator the ability to increase the security measure for the IPNet protocol. The SSPA will only answer a request
              which comes from the assigned IP address.
              To disable this feature in firmware versions prior to 6.00, set the Lock IP Address value to 0.0.0.0 or 255.255.255.255. The
              Lock IP address function was updated in firmware version 6.00 to allow "Binding" and "Masking" functions. "Binding" means
              that the first datagram re-trieved for this socket will bind to the source IP address and port number. Once binding has been
              set, the SSPA will answer to the bound IP source until the unit is restarted or reset. Without binding, the socket accepts
              datagrams from all source IP addresses. Address 0.0.0.0 allows all peers, but provides binding to the first detected IP
              source; Address 255.255.255.255 accepts all peers, without binding. If the Lock IP Address is a multicast address, then the
              amplifier will accept queries sent from any IP address of the multicast group.
Click on the 'Change IP Settings' button to save the entered settings into non-volatile memory.
              The user may also modify the web password used when accessing the web-based remote M&C. Tick the 'Modify Web
              Password' checkbox to enable the New Password field. Enter a new password and click on the 'Change' button to save.
                        Interface: IPNET
                        IP Address: 192.168.0.9
                        Local Port: 1007
                        Gateway: 192.18.0.1
                        Subnet Mask: 255.255.255.0
                        IP Lock: 255.255.255.255
                        Web password: paradise
                        Read Community: public
                        Write Community: private
                        Unit Starts Up: Unmuted
To use custom IP settings while using the Quick Start cable, remove power from the amplifier.
                                                                         20 of 44
Unit Control with Universal M&C Software (216594-2)
              Unplug the Quick Start cable from the M&C connector, J4. (If the unit is restarted with the Quick Start cable connected, it will
              always come up with default IP settings).
              Connect the Quick Start cable to J4, and check connectivity with the custom IP settings. Make sure that the Protocol setting
              in the Settings tab of the Universal M&C is set to IPNet.
              If custom IP settings will be used in normal operation, the user will need to construct an IP cable or modify the Quick Start
              Cable by disconnecting the interface control pins (pins j and e, Baud Select 0 and Baud Select 1) from ground.
              In this configuration, the SSPA will always use the saved communication control settings rather than the default
              configuration.
              The current Read/Write Community strings are displayed as read from the connected unit. Tick the Modify Read/Write
              Community checkbox to enable the New Read/Write Community field. Enter a new password and click on the 'Change'
              button to save.
                                                                        21 of 44
Unit Control with Universal M&C Software (216594-2)
              Launch the Teledyne Paradise Datacom Universal Monitor and Control software from the Programs Menu of your PC. Upon
              installation, a shortcut to the software may have been added to your desktop.
              Click the 'Action' menu and select 'Add Unit' from the pull-down menu. Select 'High Power Outdoor SSPA' from the menu
              choices. See Figure 23.
Figure 23: Universal M&C > Add Unit > High Power Outdoor SSPA
              A new dialog window will open. Enter the following information where applicable: Unit ID; if using a RS-232 Connection, the
              Serial Port and Baud Rate. See Figure 24.
Figure 24: Add High Power Outdoor SSPA > Serial Connection
If using an Ethernet Connection, enter the unit's IP Address and Port number. See Figure 25.
                                                                      22 of 44
Unit Control with Universal M&C Software (216594-2)
Figure 25: Add High Power Outdoor SSPA > Internet Connection
              Specify the unit's Address in the Amplifier Address box. If you don't know the address of the unit you may search for it. Be
              aware that this search feature is only useful when you have only one unit connected to your PC at a time.
If you wish to change the log file location, click on the 'Browse' button and navigate to the desired location.
Click on the 'Create' button to generate the operation window for this unit.
                                                                        23 of 44
Unit Control with Universal M&C Software (216594-2)
              The H-Series High Power Outdoor SSPA uses the same protocol as the Compact Outdoor SSPA, and also the same
              structure of Universal M&C.
See the Overview of the CO M&C section when using the software with a High Power Outdoor SSPA.
                                                                 24 of 44
Unit Control with Universal M&C Software (216594-2)
              Launch the Teledyne Paradise Datacom Universal M&C software from the Programs Menu of your PC. Upon installation, a
              shortcut to the software may have been added to your desktop. An Indoor PowerMAX system requires Universal M&C
              version 4.4.8b or later.
              Set the N+1 Settings for each individual unit to include the Array Size (four, eight or 16) for the PowerMAX System and the
              unique Priority Address for each unit. The amplifier assigned with the lowest Priority Address (typically 1) is granted the
              Master status for the N+1 system, and controls the other (Slave) amplifiers in the system.
Figure 26: Universal M&C > Add Unit > N+1 System
              A new 'Add N+1 System' dialog window will appear, as shown in Figure 27. If the individual amplifier N+1 settings were
              properly set, the Unit #s should automatically populate in ascending Priority Address order, using the Unit ID entered in the
              M&C. Otherwise, select the Unit # for each unit in the system and enter a System Name in the field at the bottom of the
              window. Click on the 'OK' button to initialize the system.
                                                                       25 of 44
Unit Control with Universal M&C Software (216594-2)
                      The System window may take several moments to load as the software collects and compiles the data
                    from each unit in the system.
                                                               26 of 44
Unit Control with Universal M&C Software (216594-2)
              The N+1 System tab displays an overview of each unit in the system, and overall system performance. The Universal M&C
              screen shown in Figure 28 displays the N+1 system tab (labeled PowerMAX System), as well as tabs for each of the eight
              (8) SSPA units (labeled 1, 2, 3, 4, 5, 6, 7 and 8) being monitored.
              For each unit in the system, the PowerMAX System tab displays the unit's serial number, comms status, master/slave state,
              N+1 priority in the system, mute state and fault state.
              Also shown are the System Forward Power, Reflected Power, System Gain and number of System Faults. A checkbox at the
              lower right of the window allows the user to quickly enable or disable the Auto Gain function. See the Auto Gain description
              in the Touchscreen Menu Structure section.
By hovering the mouse over the individual unit buttons, as shown in Figure 29, the unit's condtions are detailed.
                                                                       27 of 44
Unit Control with Universal M&C Software (216594-2)
              Clicking on the Unit # button to switch to the Status tab for that unit. You may also click on the unit's tab to navigate to the
              M&C windows for that unit.
              The N+1 tab for each unit shows the N+1 settings for that unit. Depending on whether the unit is assigned Master status or
              Slave status, the N+1 screen will show slightly different information. Figure 30 shows the display for the Master unit.
                                                                         28 of 44
Unit Control with Universal M&C Software (216594-2)
              The Outdoor SSPA Controllers in an Outdoor PowerMAX system can be monitored by the Universal M&C Application. All
              information is read-only.
              The operator must load each of the Outdoor SSPA Controllers individually. Refer to Table 1 for the default IP addresses to
              use.
                                                    Controller ID                                                  IP Address
                                        Outdoor SSPA Controller 1 (Master)                                         192.168.0.11
                                         Outdoor SSPA Controller 2 (Slave)                                         192.168.0.12
              Launch the Teledyne Paradise Datacom Universal Monitor and Control software from the Programs Menu of your PC. Upon
              installation, a shortcut to the software may have been added to your desktop.
              With the system operating, select the Action pull-down menu, select Add Unit, and select Outdoor PowerMAX Controller Box.
              See Figure 32.
Figure 32: Universal M&C > Add Unit > Outdoor PowerMAX Controller Box
A new dialog window will open. Select the Internet connection. See Figure 33.
                                                                      29 of 44
Unit Control with Universal M&C Software (216594-2)
              Enter the Unit ID text that will be used to identify the unit in the M&C application. For example, "Master SSPA 1" for
              Controller 1.
Use the default port 1007, or change to reflect the local network.
              Enter the global address (255) in the Amplifier Address field, and click on the [Search for Unit] button. The utility will locate
              the unit on the network. See Figure 34. Click on the [OK] button.
                                                                         30 of 44
Unit Control with Universal M&C Software (216594-2)
              This section describes the information available in each of the Universal M&C screens for the Outdoor SSPA Controllers
              used in Outdoor PowerMAX systems.
              This window displays the Mute status (Carrier Enable, indicated by "Enabled", if unmuted, or "Muted"), Attenuation and
              Summary Fault status LED. Also included is information about the System Forward RF Power, Reverse RF Power, SSPA
              Core Temperature, Main Supply Voltages, DC Current and Booster Supply Voltages.
Note: Changes to Mute Status and Attenuation made in this window will be overwritten by the system.
                                                                       31 of 44
Unit Control with Universal M&C Software (216594-2)
See your system manual for the required settings for each controller.
                      Note: All settings are read-only. Changes made to settings in this window will be overwritten by the
                    system.
Table 2 shows how the fault LEDs in this window correspond with the SSPA Modules for the indicated Outdoor Controller.
                                                                       32 of 44
Unit Control with Universal M&C Software (216594-2)
              In addition, the operator may modify the read/write community and web passwords. The operator must check the box to
              unlock the field for the new password, then click on the [Change] button to implement the change.
                                                                    33 of 44
Unit Control with Universal M&C Software (216594-2)
              Launch the Universal M&C software. Click on the Action menu and select "Add Unit", then choose "Controller" from the pull-
              down menu. See Figure 39.
              A new dialog window will appear. See Figure 40. Select the method of communication (Serial Connection, Internet
              Connection, or SNMP).
              For Serial Connections, select the Serial Port and Baud Rate, and select the amplifier address. If you don't know the address
              of the unit you may search for it. Click the Search for Unit button.
              For Internet Connection, enter the IP address of the unit, and select the port and amplifier address. Click the Search for Unit
              button if you don't know the address of the unit.
                      Note: The Search for Unit feature is only useful when you have only one unit connected to your PC at a
                    time.
For SNMP, enter the IP address of the unit and the community read/write passwords.
              A Unit ID is not required although it is recommended. If a Unit ID isn't entered the Unit ID will be assigned by the M&C. Click
              the Create button to open the M&C windows.
              Choose a log file location by clicking the Browse... button. The default is the "My Documents" folder. The log file name will be
              the UnitID and the extension ".log" appended to it. i.e. "Unit1.log".
                                                                       34 of 44
Unit Control with Universal M&C Software (216594-2)
The Universal M&C user interface features five screens which are used to monitor and control the system.
• Status
• IP Setup
• Conditions
• Settings
              Status Tab
              The first screen is the "Status" window shown in Figure 41.
              The status screen reflects the Online/Standby status of each amplifier in the system, and the switch position of each
              waveguide switch in the system. In addition, Internal and Device fault indicators are displayed. When there is no fault
              condition on a given unit, the indicator illuminates green. When a fault condition exists, the indicator illuminates red.
                       Note that in Figure 41 above, there is an RF Switch Fault. The RF Switch fault indicator is illuminated red
                     in the Internal Faults panel, and the RF Switch State in the mimic panel shows "Faulted". In addition, the
                     baseball switch icons are colored red to indicate a switch fault.
The user may click on one of the triangular amplifier icons to set that amplifier as the Standby unit in the system.
              IP Setup Window
              The second screen is the "IP Setup" window, shown in Figure 42.
                                                                        35 of 44
Unit Control with Universal M&C Software (216594-2)
              It shows the user all of the TCP/IP settings on the unit. When the IP Address is modified the unit must be reset for it to use
              the new IP Address. Until the unit is reset it will use the old IP Address. The Amplifier Local Port is the port that the unit
              monitors for UDP requests. The unit also answers requests using the same port.
              If the Amplifier Local Port is changed the unit must be reset. The Gateway Address and Subnet Mask are standard settings
              for TCPI/IP communications. If either of these settings is changed the unit must be reset for the new settings to take effect.
              The IP Lock Address is used for security. If it is set to something besides 0.0.0.0 or 255.255.255.255 it will only answer the
              address it is set to. For example, if the IP Lock Address is 192.168.0.50 then a request from 192.168.0.100 will not be
              accepted. The IP Lock Address may be changed without resetting the unit.
              Conditions Window
              The third screen displays the Conditions of the units connected to the controller, as shown in Figure 43.
              The system forward power, reflected power, power supply voltages and LNA/LNB currents and temperatures are all
              monitored. In addition, the calibration points of each LNA/LNB are displayed.
                                                                        36 of 44
Unit Control with Universal M&C Software (216594-2)
              Settings Window
              The fourth screen is the "Settings" screen, shown in Figure 44.
              It shows the user all available settings on the unit. All user-adjustable settings may be modified to suit the specific needs of
              the customer. However, it should be noted that the units are pre-configured for the customer at the factory. If modification of
              any settings is necessary, refer to the Table 7 of the Remote Control Interface section.
              From this window, the user may select the type of amplifier used in the system, choose the RF power units displayed, mute
              or unmute the system, and set the attenuation levels of the system or individual amplifier offsets. The user may also monitor
              the forward RF, temperature and DC current conditions of the HPA subsystem.
                                                                        37 of 44
Unit Control with Universal M&C Software (216594-2)
              Queries
              Click on the Queries icon at left to open the Query Settings menu. Select the PC Source Address. Adjust the interval that the
              software queries the unit. Tick the Queries Enabled checkbox to begin sending queries to the connected unit. Note that if
              queries are disabled, there will be no communication with the unit at startup. Untick the bottom checkbox to disable
              commands on units set to Local Control Mode. See Figure 47.
              Logs
              Click on the Logs icon at left to open the Log Settings menu. Adjust the interval that selected parameters are recorded (in
              minutes or seconds). Tick the checkbox to enable logging. See Figure 48.
                                                                       38 of 44
Unit Control with Universal M&C Software (216594-2)
              TCP/IP
              Click on the TCP/IP icon at left to open the TCP/IP Settings menu. Select the Local UDP Port (the software must be
              restarted to take effect). Note that each UDP address must be unique. Default Unit UDP Port is 1007. See Figure 49.
              Appearance
              Click on the Appearance icon at left to open the Appearance menu. Set the transparency of the M&C Windows. A setting of 0
              indicates no transparency. Maximum value is 80. See Figure 50.
Startup
                                                                     39 of 44
Unit Control with Universal M&C Software (216594-2)
              Click on the Startup icon at left to open the Startup menu. Tick the checkbox to enable auto-loading of the last-used device
              configuration. See Figure 51.
                                                                       40 of 44
Unit Control with Universal M&C Software (216594-2)
              Click on the 'Add/Remove' button, which opens a new window as shown in Figure 54. Select the desired device in the
              Available Devices pull-down menu. Individually select which parameters to log (or remove unwanted parameters).
Figure 54: Universal M&C Device Logger > New Log Items Window
              After choosing the parameters, the Logger window will be similar to Figure 55. Click on the Done button to accept the list of
              selected parameters.
                                                                       41 of 44
Unit Control with Universal M&C Software (216594-2)
Figure 55: Universal M&C Device Logger > New Log Items > Items Selected
              You may modify the log interval by entering the number of seconds between each record. Default interval is 1 second. Click
              on the Start Logging button to begin logging the selected parameters.
              Click on the 'File' menu and select 'Print' to print the graph and legend as shown in Figure 56. You may stop, start, and clear
              the data at any time.
                      While running the Logger, you may continue to use the Universal M&C to monitor the status of or make
                    settings modifications to any connected unit.
                                                                       42 of 44
Unit Control with Universal M&C Software (216594-2)
              The Universal M&C allows users to save multiple configurations to a variety of units. In addition, the software features a
              'Load Last Configuration' option that will reload the last configuration used by the M&C.
              To be certain the proper configuration is saved, select 'Save Configuration As...' from the 'File' menu, and navigate to a
              directory to which the file will be saved. You may wish to name the file with descriptive text about the connected unit.
                                                                         43 of 44
Unit Control with Universal M&C Software (216594-2)
Figure 59: Universal M&C File > Load Configuration from File
                                                                                44 of 44
Use and Disclosure of Data (216594-1)
                                                                                  1 of 5
Use and Disclosure of Data (216594-1)
              Information contained herein is classified as EAR99 under the U.S. Export Administration Regulations. Export, reexport or
              diversion contrary to U.S. law is prohibited.
                                                                       2 of 5
Use and Disclosure of Data (216594-1)
              The information contained in this document is the sole property of Teledyne Paradise Datacom. Any reproduction in part or
              as a whole without the written permission of Teledyne Paradise Datacom is prohibited.
All other company names and product names in this document are property of the respective companies.
                                                                        3 of 5
Use and Disclosure of Data (216594-1)
              Teledyne Paradise Datacom, a division of Teledyne Defense Electronics LLC, is a single source for high power solid state
              amplifiers (SSPAs), Low Noise Amplifiers (LNAs), Block Up Converters (BUCs), and Modem products. Operating out of two
              primary locations, Witham, United Kingdom, and State College, PA, USA, Teledyne Paradise Datacom has a more than 20
              year history of providing innovative solutions to enable satellite uplinks, battlefield communications, and cellular backhaul.
                                                                         4 of 5
Use and Disclosure of Data (216594-1)
                                                                                  5 of 5
THIS PAGE LEFT INTENTIONALLY BLANK