Product Comparison
Level
Continuous / Liquids
19.11.2018 11:24 AM
                                      Micropilot  FMR62                    Micropilot  FMR60                      Micropilot  FMR52
             Measuring principle      Level radar                          Level radar                            Level radar
      Characteristic / Application    Premium device for continuous        For basic level measurement in         Premium device for continuous
                                      non-contact level measurement,       liquids, pastes and slurries;          non-contact level measurement,
                                      in which aggressive media are        non affected by changing media,        in which aggressive media are
                                      used as well as for highest          temperature changes, gas               used as well as for highest
                                      hygiene requirements (ASME           blankets or vapor;                     hygiene requirements (ASME
                                      BPE, USP Class VI); For              For applications with many             BPE, USP Class VI);
                                      applications with many obstacles     obstacles due to the very small        Flush mounted, fully PTFE filled
                                      for small vessels due to the very    beam angle.                            horn antenna
                                      small beam angle.
                       Specialities   Heartbeat Technology                 Heartbeat Technology,                  Heartbeat Technology,
                                      SIL 2/3 according to IEC 61508,      SIL 2/3 according to IEC 61508,        SIL 2 according to IEC 61508,
                                      <I>Bluetooth®</I>                    <I>Bluetooth®</I>                      <I>Bluetooth®</I>
                                      commissioning,                       commissioning,                         commissioning,
                                      Operation and maintenance            Operation and maintenance              Operation and maintenance
                                      SmartBlue App,                       SmartBlue App, Safety and              SmartBlue App,
                                      Safety and reliability with Multi-   reliability with Multi-Echo Tracking   Safety and reliability with Multi-
                                      Echo Tracking,                       HistoROM                               Echo Tracking,
                                      HistoROM,                            RFID TAG for easy identification       HistoROM,
                                      RFID TAG for easy identification                                            RFID TAG for easy identification
         Supply / Communication       2-wire (HART),                       2-wire (HART)                          2-wire (HART / PROFIBUS PA/
                                      Bluetooth® wireless technology       Bluetooth® wireless technology         FOUNDATION Fieldbus)
                                      and App (optional)                   and App (optional)                     4-wire (HART)
                                                                                                                  Bluetooth® wireless technology
                                                                                                                  and App (optional)
                       Frequency      W-band (~80 GHz)                     W-band (~80 GHz)                       K-band (~26 GHz)
                         Accuracy     +/- 1 mm (0.04 in)                   +/- 1 mm (0.04 in)                     +/- 2 mm (0.08 in)
            Ambient temperature       -40…+80 °C                           -40…+80 °C                             -50...+80 °C
                                      (-40…+176 °F)                        (-40…+176 °F)                          (-58...+176 °F)
            Process temperature       -40…+200 °C                          -40…+130 °C                            -196...+200 °C
                                      (-40…+392 °F)                        (-40…+266 °F)                          (-321...+392 °F)
Process pressure absolute / max.      Vacuum…+25 bar                       Vacuum …16 bar                         Vacuum...25 bar
              overpressure limit      (Vacuum…+362.6 psi)                  (Vacuum … 232 psi)                     (Vacuum...363 psi)
               Main wetted parts      PTFE or PEEK antenna,                PTFE antenna                           PTFE
                                      316L threads,                        PP or 316L process connections
                                      PTFE cladded flanges
             Process connection       Threads:                             Thread:                                Flange:
                                      G, MNPT 3/4", 1-1/2"                 G1-1/2", MNPT1-1/2";                   DN50...DN150
                                      Flanges:                             Flange:                                ASME 2"...6"
                                      DN50 ... DN150                       UNI DN80…DN150 (3"…6")                 JIS 10K
                                      ASME 2" ...6"
     Process connection hygienic      DIN11851, Tri-Clamp                                                         Tri-Clamp ISO2852
                                                                                                                  DIN11851
                       Application                                                                                Storage tank
     Max. measurement distance        80 m (262 ft)                        50 m (164 ft)                          Standard: 40 m (131 ft)
                                                                                                                  With enhanced dynamics: 60 m
                                                                                                                  (197 ft)
                                                                                                                                               1/2
Product Comparison
Level
Continuous / Liquids
19.11.2018 11:24 AM
                 Communication       4…20 mA HART,                     4…20 mA HART,                     4...20 mA HART
                                     Additional switch,                Additional switch,                PROFIBUS PA
                                     Bluetooth® wireless technology    Bluetooth® wireless technology    FOUNDATION Fieldbus
                                                                                                         Bluetooth® wireless technology
          Certificates / Approvals   ATEX, FM, CSA C/US, IEC Ex,       ATEX, FM, CSA C/US, IEC Ex,       ATEX, FM, CSA, CSA C/US, IEC
                                     INMETRO, NEPSI, EAC               INMETRO, NEPSI, EAC               Ex, JPN Ex, INMETRO, NEPSI,
                                                                                                         KC
                Safety approvals     Overfill prevention WHG,          SIL 2, SIL 3                      Overfill prevention WHG
                                     SIL 2, SIL 3                                                        SIL
               Design approvals      EN 10204-3.1                      EN 10204-3.1                      EN 10204-3.1
                                     NACE MR0175, MR0103                                                 ASME B31.3
                                     AD2000                                                              AD2000
              Hygienic approvals     CoC-ASME BPE                                                        3A, EHEDG
                                                                                                         CoC ASME-BPE
                 Marine approval                                                                         GL/ ABS/ LR/ BV/ DNV
                         Options     Display,                          Display,                          Display,
                                     Customized parameterization,      Customized parameterization,      Customized parameterization,
                                     Remote operation via SmartBlue    Remote operation via SmartBlue    Remote operation via SmartBlue
                                     App using Bluetooth®,             App using Bluetooth®,             App using Bluetooth®,
                                     PWIS free,                        Gas-tight feed through,           Gas-tight feed through,
                                     Gastight feed through             PWIS free                         PWIS free
                Application limits   Process temp. > 200 °C (392 °F)   Process temp. > 130 °C (266 °F)   Ammoniacal gas phase:
                                     -> FMR5x                          -> FMR62                            FMR54 in stilling well
                                     Strong turbulences and foam,      Very aggressive media -> FMR62    Strong build-up formation:
                                     stilling well and bypass ->       Strong turbulences and foam,        FMR54 with air purge
                                     FMR5x,FMP5x                       stilling well and bypass ->       Custody transfer measurement:
                                                                       FMR5x, FMP5x                        FMR5xx
                                                                                                                                   2/2