Product data sheet                                     GV2ME16
Characteristics                                        Motor circuit breaker, TeSys GV2, 3P, 9-14 A,
                                                       thermal magnetic, screw clamp terminals
                                                                                                            Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
    Range                               TeSys
    Product name                        TeSys GV2
    Product or component type           Circuit breaker
    Device short name                   GV2ME
    Device application                  Motor
    Trip unit technology                Thermal-magnetic
Complementary
    Poles description                   3P
    Network type                        AC
    Utilisation category                AC-3 conforming to IEC 60947-4-1
                                        Category A conforming to IEC 60947-2
    Network frequency                   50/60 Hz conforming to IEC 60947-4-1
    Fixing mode                         35 mm symmetrical DIN rail: clipped
                                        Panel: screwed (with adaptor plate)
    Operating position                  Any position
    Motor power kW                      5.5 kW at 400/415 V AC 50/60 Hz
                                        7.5 kW at 500 V AC 50/60 Hz
                                        9 kW at 690 V AC 50/60 Hz
                                        11 kW at 690 V AC 50/60 Hz
    Breaking capacity                   100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
                                        3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
                                        15 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
                                        8 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
                                        6 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
    [Ics] rated service short-circuit   100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
    breaking capacity                   75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
                                        75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
                                        50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
                                        50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
Apr 22, 2021
                                                                                                        1
Control type                             Push-button
[In] rated current                       14 A
Thermal protection adjustment range      9…14 A
Magnetic tripping current                170 A
[Ue] rated operational voltage           690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage            690 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal      14 A conforming to IEC 60947-4-1
current
[Uimp] rated impulse withstand voltage   IEC 60947-2 6 kV
Power dissipation per pole               2.5 W
Mechanical durability                    100000 cycles
Electrical durability                    100000 cycles for AC-3 at 440 V
Maximum operating rate                   25 cyc/h
Rated duty                               Continuous conforming to IEC 60947-4-1
Tightening torque                        1.7 N.m on screw clamp terminals
Suitability for isolation                Yes conforming to IEC 60947-1
Phase failure sensitivity                Yes conforming to IEC 60947-4-1
Height                                   89 mm
Width                                    45 mm
Depth                                    78.5 mm
Net weight                               0.26 kg
Environment
Standards                                EN/IEC 60947-2
                                         EN/IEC 60947-4-1
                                         CSA C22.2 No 60947-4-1
                                         UL 60947-4-1
Product certifications                   IECEE CB Scheme
                                         UL
                                         CSA
                                         CCC
                                         EAC
                                         ATEX
                                         BV
                                         LROS (Lloyds register of shipping)
                                         DNV-GL
                                         RINA
Protective treatment                     TH
IP degree of protection                  IP20 conforming to IEC 60529
IK degree of protection                  IK04
Ambient air temperature for operation    -20…60 °C
Ambient air temperature for storage      -40…80 °C
Fire resistance                          960 °C conforming to IEC 60695-2-1
Operating altitude                       2000 m
Packing Units
Unit Type of Package 1                   PCE
Number of Units in Package 1             1
Package 1 Weight                         277 g
Package 1 Height                         4.7 cm
Package 1 width                          8.5 cm
Package 1 Length                         9 cm
Unit Type of Package 2                   S02
Number of Units in Package 2             24
Package 2 Weight                         7.223 kg
Package 2 Height                         15 cm
  2
Package 2 width                30 cm
Package 2 Length               40 cm
Unit Type of Package 3         P06
Number of Units in Package 3   384
Package 3 Weight               122.148 kg
Package 3 Height               80 cm
Package 3 width                80 cm
Package 3 Length               60 cm
Offer Sustainability
Sustainable offer status       Green Premium product
REACh Regulation               REACh Declaration
EU RoHS Directive              Compliant
                               EU RoHS Declaration
Mercury free                   Yes
RoHS exemption information     Yes
China RoHS Regulation          China RoHS declaration
                               Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure       Product Environmental Profile
WEEE                           The product must be disposed on European Union markets following specific waste collection and
                               never end up in rubbish bins
California proposition 65      WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony
                               trioxide, which is known to the State of California to cause cancer. For more information go to
                               www.P65Warnings.ca.gov
Contractual warranty
Warranty                       18 months
                                                                                                                                 3
Product data sheet                                      GV2ME16
Performance Curves
Thermal-Magnetic Tripping Curves for GV2ME and GV2P
Average Operating Times at 20 °C Related to Multiples of the Setting Current
1         3 poles from cold state
2         2 poles from cold state
3         3 poles from hot state
Current Limitation on Short-Circuit for GV2ME and GV2P (3-Phase 400/415 V))
Dynamic Stress
I peak = f (prospective Isc) at 1.05 Ue = 435 V
    4
1           Maximum peak current
2           24-32 A
3           20-25 A
4           17-23 A
5           13-18 A
6           9-14 A
7           6-10 A
8           4-6.3 A
9           2.5-4 A
10          1.6-2.5 A
11          1-1.6 A
12          Limit of rated ultimate breaking capacity on short-circuit of GV2ME (14, 18, 23, and 25 A ratings).
Thermal Limit on Short-Circuit for GV2ME
                     2
Thermal Limit in kA s in the Magnetic Operating Zone
        2
Sum of I dt = f (prospective Isc) at 1.05 Ue = 435 V
                                                                                                                  5
1        24-32 A
2        20-25 A
3        17-23 A
4        13-18 A
5        9-14 A
6        6-10 A
7        4-6.3 A
8        2.5-4 A
9        1.6-2.5 A
10       1-1.6 A
     6
Product data sheet                                        GV2ME16
Dimensions Drawings
Dimension
GV2ME
(1)      Maximum
         X1 Electrical clearance = 40 mm for Ue ≤ 690 V
GV2ME●●                                                       89
GV2ME●●3                                                      101
Mounting
GV2ME
On 35 mm rail
c = 78.5 on AM1 DP200 (35 x 7.5)
c = 86 on AM1 DE200, ED200 (35 x 15)
On panel with adapter plate GV2AF02
On pre-slotted plate AM1 PA
On rails DZ5 MB201
                                                                    7
GV2AF01
Combination GV2ME + TeSys k contactor
GV2AF3
Combination GV2ME + TeSys d contactor
GV2ME +                LC1D09…D18         LC1D25 and D32
b                      176.4              186.8
c1                     94.1               100.4
c                      99.6               105.9
GV2AF4 + LAD311
Combination GV2ME + TeSys d contactor
GV2ME +                 LC1D09…D18      LC1D25 and D32
b                       176.4           186.8
c1                      103.1           136.4
c                       135.6           141.9
d1                      107             107
d                       112.5           112.5
GV2ME + GV1L3 (Current Limiter)
    8
X1 = 10 mm for Ue = 230 V or 30 mm for 230 V < Ue ≤ 690 V
                                                            9
Product data sheet                                  GV2ME16
Connections and Schema
GV2ME•• and GV2RT
Connection of Undervoltage Trip for Dangerous Machines (Conforming to INRS) on GV2ME Only
 10