Reliable
performance
                   Fan speed control is becoming              Designed by Saginomiya in Japan, the
                                                            new XGE complements the already well
                  increasingly widespread in different
                                                            established range of RGE fan speed
                  refrigeration and air conditioning        controllers, maintaining the excellent
                  units, with the benefits of reduced       performance and reliability record.
                                                            Extensive performance testing under
                  noise     and    stable     condensing    different conditions, and stringent
                  pressures under different climatic        quality control procedures ensure
                                                            trouble free operation for many
                  conditions.
XGE Fan Control
                                                            years.
                   For compact units, the new XGE from        For     example,     prevention
                                                            of overheating is extremely
                  Danfoss Saginomiya provides the ideal     important in such compact
                  solution for reliable fan control.        controllers, and a specially
                                                            designed heat dissipation
                   With XGE, fan control has never          radiator is placed on the side
                                                            of the controller, ensuring
                  been easier to implement. It can          no overheating and a longer
                  be mounted directly onto the              product lifetime.
                  refrigeration line, adjustment is           In addition, XGE is fitted
                                                            with an electro-magnetic
                  made by the turn of a setting
                                                            suppression filter meeting
                  screw, and electrical connection is       the requirements of the CE
                  very versatile. It can also be panel      and EMC directives.
                  mounted where space is insufficient
                  on the refrigeration line. It can be      Features
                  used for all the commonly used            Max current                     3A
                                                            Min current                     0,2A
                  refrigerants, including R410A.
                                                            Enclosure                       IP 65
                                                            Max working pressure            47 bar
                   This installation and application        Supply frequency                50/60 Hz
                                                            Operating ambient temperature   -20 to 55 oC
                  flexibility provides the ideal solution   Fluid temperature               -20 to 70 oC
                  for     many    different   types    of   Power supply                    200-240 VAC
                                                            Pressure connection             7/16-20UNF female
                  condensing and air conditioning units.                                    with depressor pin
                                                            Max voltage output              95% of supply voltage
                                                            Cut off / Min speed             45% of supply voltage
                                                                                            for 50Hz
                                                                                            35% of supply voltage
                                                                                            for 60Hz
Ease of setting
and adjusting
  The easily accessible adjusting screw is situated on the top surface
of XGE. The direction to turn the screw for decrease or increase
in the setting pressure is indicated by arrow markings next to the
adjusting screw.
  Every turn of the adjusting screw corresponds to a specified
                                                                                                          Series                                360o = 1 turn
change in the setting value. A punch hole on the adjusting screw                                         XGE - 4                               approx. 1,2 bar
helps keep track of the number of turns made.                                                            XGE - 6                               approx. 1,6 bar
                                                                                  Compact and
                                                                                  light-weight
                                                                                      The compact design of XGE provides versatile
                                                                                    installation possibilities where space is at a
                                                                                    premium. The horizontal space occupied by
                                                                                    XGE, in any orientation, is equivalent to a
                                                                                    circular diameter of only 66mm.
                                                                                      The height of the contoller is 90mm, and
                                                                                    when the plug is fitted, only 112mm of vertical
                                                                                    space is occupied. Combined with the light
                                                                                    weight (180g), the XGE is ideally suited for
                                                                                    installation on refrigeration lines without
                                                                                    excess stress on the pipework.
                                                                   112mm
                                                                                                                                               max speed
                                                                           ø 66mm
                                                                                                                                                                   Hz
                                                                                                                                                                 Hz
                                                                                                                                                                50
                                                                                                         effective voltage R.M.S. (V%)
Wide application
                                                                                                                                                              60
                                                                                                                                                          V@
                                                                                                                                                           V@
                                                                                                                                                   230
possibilities
                                                                                                                                                            230
                                                                                                                                         min speed
  Code     Catalogue Factory set                              Adjusting range   Prop. band
                                         Refrigerant                                           Mode
 number     number      [bar]                                      [bar]           [bar]
                                                                                                                                                cut off
                                                                                                                                                          prop.band
061H3140   XGE-4C        19        R22, R134a, R404A, R407C       10-25              6        cut-off
061H3160    XGE-6C       28                 R410A                 22-39              7        cut-off
061H3240   XGE-4M        19        R22, R134a, R404A, R407C       10-25              6       min speed
                                                                                                                                             pressure [bar]
061H3260   XGE-6M        28                 R410A                 22-39              7       min speed                                              set point
 Installation flexibility
  The XGE is designed to be directly   In cases where space is even more
mounted onto the refrigeration line limited, XGE can be fixed onto a simple
making the most of free space in a bracket (supplied as an accessory) and
unit.                                screwed to a panel.
               Direct mount                                          Panel mount
                                                                                        Panel mounting bracket
                                                                                        Code number          Catalogue number
                                                                                          061H3102               XGE-AE01
Easy wiring
and electrical connection
                                               Electrical connection of XGE to the fan motor is
                                             simple and easy.
                                               With the use of a square “quick connect” plug, the
                                             connection is possible in 4 different directions, allowing
                                             many different machine configurations to accommodate
                                             XGE, depending on the position of the fan motor and
                                             orientation needed for the electrical cable.
                                                                                      For wiring, a simple diagram
                                                                                    is embossed onto the XGE sur-
                                                                                    face and also indicated on the
                                                                                    plug.
                                                   Danfoss Saginomiya Sp. z o.o.
                                        ul. Chrzanowska 5; 05-825 Grodzisk Mazowiecki Poland
                                            Phone +48 (22) 7550 500, Fax +48 (22) 7550 505
                                    info@danfoss-saginomiya.com, www.danfoss-saginomiya.com
Danfoss Saginomiya Sp. z o.o. can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss
Saginomiya Sp. z o.o. reserves the right to alter its products without notice. This also applies to products already on order, provided that such
alteration can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are
property of the respective companies. Danfoss Saginomiya and the Danfoss Saginomiya logotype are trademarks of Danfoss Saginomiya
Sp. z o.o. All rights reserved.
PLRCA.PB.LC0.A1.02