0% found this document useful (0 votes)
180 views6 pages

4G Datalogger Installation Guide

The installation manual provides instructions for installing the Z-LTE 4G + worldwide datalogger. It can be installed on a standard DIN rail and has integrated I/O, remote control functions, and an internal UPS. LED lights on the front panel indicate status of power, cellular signal strength, data transfer, and digital/analog I/O ports. Proper ventilation is required and it should not be installed near heat sources. Wiring connections can be made directly via the rear connector or using an optional accessory rail.

Uploaded by

Omair Farooq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
180 views6 pages

4G Datalogger Installation Guide

The installation manual provides instructions for installing the Z-LTE 4G + worldwide datalogger. It can be installed on a standard DIN rail and has integrated I/O, remote control functions, and an internal UPS. LED lights on the front panel indicate status of power, cellular signal strength, data transfer, and digital/analog I/O ports. Proper ventilation is required and it should not be installed near heat sources. Wiring connections can be made directly via the rear connector or using an optional accessory rail.

Uploaded by

Omair Farooq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

INSTALLATION MANUAL

Z-LTE
4G + worldwide Datalogger with integrated I/O, remote control
(Versión Z-LTE - ww)

functions, integrated UPS, GPS and advanced programming

EN

SENECA s.r.l.
Via Austria, 26 – 35127 – PADOVA – ITALY
Tel. +39.049.8705355 - 8705359 - Fax +39.049.8706287
For manuals in other languages and the configuration software, visit www.seneca.it/products/z-lte

MI00514-6-EN 1/6
MODULE LAYOUT
35 mm 111 mm

102.5

mm
Weight: 270 g;
Container: PA6, Black
SIGNALS VIA LED ON FRONT PANEL
LED STATUS LED meaning
ON Log not active and status waiting for startup
Slow flashing Log active and status in normal operation
PWR
Flashing intermittently Status in operation from backup battery (battery life 1 hour)
(Green)
Fast flashing Error, see Webserver diagnostics
Off Device OFF
ON Maximum signal (Level 4)
3 flashes (Level 3)
(GSM LEVEL) Flashing 2 flashes (Level 2)
(Green) 1 flash (Level 1)
Off Minimum signal
Short flash Network search (200ms High / 1800 ms Low)
GSM
Long flash Connected (1800 ms High / 200ms Low)
(STATUS)
Fast flashing Data transfer in progress (125ms High / 125ms Low)
(Yellow)
On Voice call
MOD On Recorded on 4G network
(Yellow) Off Connected to another network
DO (1 and 2) On Digital output, relay energised
(Red) Off Digital output, relay de-energised
ON (NPN) Digital input energised (GND closed contact)
DI (from 1 to 4)
ON (PNP) Digital input energised (contact closed to +12 V)
(Red)
Off Digital input not energised
Slow flashing Activity in the RS485 or RS232 serial interface
COM
Off RS485 or RS232 serial interfaced not used
(Red)
Fast flashing Timeout in the RS485 or RS232 communication
On SD card inserted correctly
SD Slow flashing Activity on SD card
(Red) Fast flashing SD card error
Off No SD card
ETH LNK Flashing Connection on RJ45 active
ETH ACT Flashing Packet transit on Ethernet port

2/6
PRELIMINARY WARNINGS
The word WARNING preceded by the symbol indicates conditions or actions that put the user's safety at
risk. The word ATTENTION preceded by the symbol indicates conditions or actions that might damage the
instrument or the connected equipment. The warranty shall become null and void in the event of improper use or
tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if
the instructions contained in this manual are not followed.
WARNING: The full content of this manual must be read before any operation.
The module must only be used by qualified electricians.
Specific documentation is available at www.seneca.it/products/z-lte
The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to
electrostatic discharges. Take appropriate measures during any operation.

Important: Obstructing ventilation slots with any object is prohibited.


Installing the module next to devices that generate heat is prohibited.
Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling).
The symbol on the product or its packaging shows the product must be surrendered to a collection centre
authorized to recycle electrical and electronic waste.
INSTALLATION REGULATIONS
The module has been designed for vertical installation on a DIN 46277 rail. For optimal operation and long life,
adequate ventilation must be provided. Avoid positioning ducting or other objects that obstruct the ventilation slots.
Avoid mounting modules over heat-generating equipment. Installation in the bottom part of the electrical panel is
recommended.
Inserimento
Insertion in nella
the
Insertion in the DIN rail guida DIN
DIN rail MODULE
MODULO

As shown in figure:
1. Insert the IDC10 rear connector of the module on a
free slot of the DIN rail
(the insertion is univocal since the connectors are
polarized).
2. To secure the module to the DIN rail, tighten the two
hooks on the sides of the IDC10 rear connector. DINDIN
Guida rail

USE OF THE Z-PC-DINAL ACCESSORY


Power supply and Modbus interface are available using the Seneca DIN rail bus, via the IDC10 rear connector, or
the Z-PC-DINAL-17.5 accessory.
RS485 GND Power Supply AC / + Back connector (IDC 10)
Power Supply AC / - The illustration shows the meanings of the various
RS485 A IDC10 connector pins if signals are to be sent via
them directly.
1
IDC 10
RS485 B

Ground
Power Supply AC Power Supply AC DIP SWITCH Z-PC-DINAL2-17.5 accessory use
If the Z-PC-DINAL2-17.5 accessory is used, signals
can be sent via terminal boards. The illustration
shows the meaning of the various terminals and
DIP-switch position (found in all supports for the DIN
rail listed in Accessories) for the termination of the
CAN network (not used for the Modbus network).
GNDSHLD:
GNDSHLDG ND
Connection cable signal protection shield
CANL / A CANL / B
(recommended).

3/6
TECHNICAL SPECIFICATIONS
EN61000-6-4 Electromagnetic emissions, industrial environment.
EN61000-6-2 Electromagnetic immunity, industrial environment.
EN301 511 Global standards for mobile communications.
STANDARDS
EN301 489-1 Electromagnetic compatibility for mobile radio equipment.
EN301 489-7 Specific conditions (EMC) for mobile radio equipment.
EN60950 Security in information processing equipment.

INSULATION Digital

Temperature: -25– + 50°C / (-10– + 40°C if the internal UPS is used).


ENVIRONMENTAL Humidity: 30%– 90% non condensing.
CONDITIONS Storage temperature: -30– + 65°C / (-20– + 45°C < 6 months if the internal UPS is used).
protection rating: IP20.
ASSEMBLY IEC EN60715, 35mm DIN rail in vertical position.
INTERNAL UPS Rechargeable backup batteries. Duration: up to 1 hour.
Removable 3-way screw terminals, 5 mm pitch for cable up to 2.5 mm²,
CONNECTIONS
Rear IDC10, RJ45 socket, Micro USB socket and 2 SMA for 4G antenna and GPS antenna.
POWER SUPPLY Voltage: 11 ÷ 40 Vdc or 19 ÷ 28 Vac 50 ÷ 60 Hz. Absorption: < 6.5W.
Number of channels 4. Configurable PNP or NPN.
DIGITAL INPUTS Voltage OFF<4V, ON>8V (Max. 24Vdc).
Max frequency 30Hz. Absorbed current 3mA @ 12Vdc 10mA @ 24Vdc.
TOTALIZERS 4 x 32-bit totalizers on non-volatile memory
COUNTERS: 4 x 32-bit resettable counters on non-volatile memory.
DIGITAL OUTPUTS Number of channels 2. SPDT free contact relay. Max. voltage 250Vac. Max. current 2A.
Number of channels 2. Configurable mAdc or Vdc.
ANALOGUE Voltage input 0 – 30V. precision 0.1% of Full Scale, impedance: 200 kohm.
INPUTS Current input 0– 20mA precision 0.1% of Full Scale, impedance: < 60 ohm.
Input protection 40V / 25mA. Resolution 16 bit.
COMMUNICATION RS485 COM1 on rear IDC10 connector, RS485 or RS232 on terminals M10-M11-M12,
PORTS Ethernet 100 base T and micro USB on side socket.
4G/LTE Model (Europe, Africa, Middle Est, Korea, Thailand, India) Contact Seneca for other
countries. GSM / GPRS/ EDGE Dual-band: 1800 / 900 Mhz. UMTS / HSPA+, Tri-band: WCDMA
MODEM 4G
2100 / 850 / 900 Mhz. 4G LTE Band 6- Band: 2100/1800/850/2600/900/800 MHz Certifications: CE/
GCF/Vodafone (Europe), KC/SKT/KT/LGU+ (Korea)
GNSS GPS / GLONASS / BeiDou(compass) / Galileo / QZSS
STORAGE UNIT microSD and microSDHC 32GB max.
CPU / S.O. ARM 32bit, operating system: Real Time Multitasking, built-in Webserver and on microSD.

4/6
ELECTRICAL CONNECTIONS
CAUTION
On first start-up the module must be supplied without any interruptions for at least 72 hours to charge the internal
batteries. Switch the module off with the PS1 button before connecting inputs and outputs.
To meet the electromagnetic immunity requirements:
- use shielded signal cables;
- connect the shield to a preferential instrumentation earth system;
- separate shielded cables from other cables used for power installations (transformers, inverters, motors, etc...).

Power supply
Terminals 2 and 3 can be used to provide the module with power supply as an
Aux. volt. 1 alternative to the connection using the Z-PC-DINx bus.
The power supply voltage must remain in the range of either 19 and 40V DC (any
Vac/Vdc 2 polarity), or 19 and 28V AC.
Vac/Vdc 3 The upper limits must not be exceeded as this can seriously damage the module.
If the power supply source is not protected against overload, a safety fuse with a 1 A
max permissible value must be installed in the power supply line.
Serial port 2: RS485 SW2 = OFF
GND 10 Z-LTE has a serial port that can be set with the SW2 switch.
If switch SW2 is in the OFF position, the RS485 COM 2 port is available at terminals
A (+) 11 10-11-12. The illustration shows how to complete connections.
B (-) 12 N.B.: the indication of the RS485 connection polarity is not standardised and in some
devices may be inverted.
Serial port 2: RS232 SW2 = ON
GND 10 Z-LTE has a serial port that can be set with the SW2 switch.
If switch SW2 is in the ON position, the RS232 COM 2 port is available at terminals
RX 11 10-11-12.
TX 12 The illustration shows how to complete connections.
The RS232 interface is fully settable.

ANALOGUE INPUTS
Voltage Active sensor current Passive sensor current (2 wires) The module has two
(4 wires) analogue inputs that
can be configured via
+ + software as voltage
+ +  or current. For the
 configuration software,
see the user manual.
(*) Not available without external power supply

DIGITAL INPUTS
NPN with internal power PNP with internal power PNP with external power

5/6
DIGITAL OUTPUTS

The module has two


digital outputs with free
contacts. The figures
show the internal relay
contacts available.

ANALOGUE INPUTS

SIM Inserting the microSD


Inserting the SIM into or microSHDC card,
the rear slot next to into the side slot.
the IDC10 connector. MAX 32 GB.
Push-push connector.

PROCEDURE FOR MODULE SWITCH-OFF


The module is equipped with an integrated UPS that allows it to remain on even in the absence of external power.
To turn off the module, first disconnect the external power supply and then press the PS1 button on the right side
of the module for at least 6 seconds.
When the button is released, the PWR LED turns off to indicate that the module is turned off.

DIP - SWITCH SETTINGS


DIP-SWITCHES
Default settings: all DIP switches in OFF position. 
SW1
For more information see the USER MANUAL.

RS232 or RS485 settings on terminals 10-11-12 (COM2 serial port)

SW2 RS232 ON

RS485 OFF

CONTACT INFORMATION
Technical support support@seneca.it Product information sales@seneca.it

This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised.
The content of this document corresponds to the described products and technologies.
Stated data may be modified or supplemented for technical and/or sales purposes.
6/6

You might also like