Step 5 Testing your Dimmer prior to mounting in • Follow directions in the Z-Wave® controller to complete the adding process.

controller to complete the adding process. • Tap the top of the paddle twice.
wall box: • Upon successful addition to network the LED will turn off and then blink green 3 The Locator LED will flash amber 3 times to confirm the selection.
TROUBLESHOOTING
decora smart™ NOTE: If using in a dimmable fluorescent of CFL application see Load Type
Setup prior to testing the device.

times.
If the adding process is not successful the LED will flash red 3 times. LED Off: Locator LED is always Off:
The Locator LED is turned off: •
Lights Flickering
Traditional Inclusion: • Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator - Lamp has a bad connection.
• Position all wires to provide room in For older controllers Traditional Inclusion is supported. Depending on the - Wires not secured firmly with wire connectors of dimmer
LED will blink amber.
outlet wall box for device. age of the controller the controller will need to be 3 to 35 feet from the device or terminal screws of remote.
• Tap the top of the paddle 4 times.
• Ensure that the word “TOP” is facing when including. - If using in a dimmable fluorescent application see Load
The Locator LED will quickly flash green and amber.
up on device strap. Type Setup prior to testing the device.
Dimmer with Z-Wave ® • Partially screw in mounting screws
in wall box mounting holes.
• Enter Programming Mode by holding the top of the paddle for 7 seconds, the
Locator LED will blink amber.
• Tap the top of the paddle 3 times.
The Locator LED will flash red 3 times to confirm the selection. • Light does not turn ON and Locator LED does not turn
ON
Technology NOTE: Dress wires with a bend as


The Decora SmartTM Z-Wave® device is ready to add to the Z-Wave® network.
Follow directions in the Z-Wave® controller to enter learn mode.
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
shown in diagram in order to relieve • Tap the top of the paddle one time. The Locator LED will quickly flash green.
Cat. No. DZ6HD stress when mounting device. The Z-Wave® controller will begin to pair with the Decora SmartTM device. FADE ON/OFF TIMES - Neutral not wired to Dimmer (White wire).
- Confirm that the device is being supplied from a 120V
• Upon successful addition to the network the LED will turn off and then blink
Leviton Decora Smart Z-Wave devices have the ability to alter the fade on and
® AC, 60 Hz source ONLY.
green 3 times.
Incandescent, LED, CFL fade off times. • Intermittent dimmer operation
• If the adding process is not successful the LED will flash red 3 times.
Dimmer - Confirm that the Load being controlled does not exceed
To change the Fade On Time: the 1000VA dimmer limit.
EXCLUSION FROM A Z-WAVE® NETWORK • Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator • Remote does not operate lights
Rated: 120 VAC, 60 Hz LED will turn amber. - Ensure that total wire length does not exceed 300 ft.
600W Incandescent When removing a device from a Z-Wave® network best practice is to use the - Ensure wiring is correct.
• Restore power at circuit breaker or fuse. • Tap the top of the paddle 6 times.
exclusion command found in the Z-Wave® controller.
300W LED/CFL • Press pad until locator light is OFF. Lights should • The Locator LED will quickly flash green and red.
turn ON. If lights do not turn ON, press the TOP • Enter Programming Mode by holding the top of the paddle for 7 seconds, the • Tap the top of the paddle once. The Locator LED will flash amber/red.
half of the DIM/BRIGHT Bar until the lights Locator LED will blink amber. • Use the dim/bright bar to adjust the speed of dimming using the chart below: ADVANCED OPTIONS
brighten. • Follow directions in the Z-Wave® controller to enter exclusion mode
• Tap the top of the paddle one time. The Locator LED will quickly flash green. To change the Fade Off Time:
INSTALLATION INSTRUCTIONS If lights still do not turn ON, refer to
the TROUBLESHOOTING section. The Z-Wave® controller will exclude the Decora SmartTM device • Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator Leviton Decora SmartTM Devices are configurable
LED will turn amber. through the paddle as well as over the Z-Wave® network.
• The Z-Wave® controller will confirm successful exclusion from the network.
• Tap the top of the paddle 6 times. Compatible Z-Wave® controllers can add support for
additional advanced options. Consult your Z-Wave®
Step 6 Dimmer Mounting: LOAD TYPE SETUP • The Locator LED will quickly flash green and red.
controller manufacturer for compatibility with advanced
TURN OFF POWER AT • Tap the top of the paddle twice. The Locator LED will flash Red.
• Use the dim/bright bar to adjust the speed of dimming using the chart below: feature support.
CIRCUIT BREAKER OR FUSE. Leviton Decora SmartTM Z-Wave® dimmers are compatible with different types
Schedule or Installation may now be completed by tightening of loads. Choosing the correct load type will increase compatibility and provide Fade On Time
• Parameter No: 1, Length: 1 Byte
mounting screws into wall box. Attach wall plate. proper operation.
dim lights from LED Value • Valid Values = 0 to 253 (default 2)
Incandescent Loads (Default): - 0 = Instant On
anywhere using Step 7 Restore Power: • Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator 7 (Top LED) 30 Seconds
- 1 - 127 = Seconds: 1 - 127 seconds
Restore power at circuit breaker or fuse. 6 16 Seconds
a compatible Installation is complete.
LED will blink amber.
• Tap the top of the paddle 4 times. 5 8 Seconds
- 128 - 253 = Minutes: 1 - 126 minutes
Z-Wave® The Locator LED will quickly flash green and amber. 4 4 Seconds Fade Off Time
controller OPERATION • Tap the top of the paddle 4 times. 3 2 Seconds • Parameter No: 2, Length: 1 Byte
The Locator LED will flash green/amber 3 times to confirm the selection. 2 1 Second • Valid Values = 0 to 253 (default 2)
NOTE: At default the locator light will illuminate when LED Brightness - 0 = Instant Off
LED Loads: 1 (Bottom LED) Instant
the load is in the OFF position to facilitate access in Display - 1 - 127 = Seconds: 1 - 127 seconds
• Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator - 128 - 253 = Minutes: 1 - 126 minutes
the dark. DIM/BRIGHT LED will blink amber.
NOTE: If using the dimmer in a 3-way application, the Bar • Hold the top of the paddle to exit. The Locator LED will quickly flash amber to Minimum Light Level
• Tap the top of the paddle 4 times.
lights will turn ON at brightness set on dimmer’s DIM/ confirm. • Parameter No: 3, Length: 1 Byte
The Locator LED will quickly flash green and amber.
BRIGHT bar. The lighting can be controlled from either • Tap the top of the paddle 5 times. • Valid Values = 0 to 100 (default 10)
© 2018 Leviton Mfg. Co., Inc. DI-000-DZ6HD-02B
the dimmer, the remote location or a Z-Wave® enabled The Locator LED will flash green/red 3 times to confirm the selection. PRESET LIGHT LEVEL
controller. Maximum Light Level
Leviton Decora Smart Z-Wave® devices have the ability to alter the preset light level. • Parameter No: 4, Length: 1 Byte
Rocker (Default settings) CFL Loads:
• Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator • Valid Values = 0 to 100 (default 100)
• Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator
Turn ON from OFF position: LED will turn amber.
LED will blink amber.
Tap TOP of Rocker: Lights turn ON to preset level. • Tap the top of the paddle 7 times. Preset Light Level
• Tap the top of the paddle 4 times.
Turn OFF from ON position: • The Locator LED will quickly flash red and amber. • Parameter No: 5, Length: 1 Byte
The Locator LED will quickly flash green and amber.
Tap BOTTOM of Rocker. Lights turn OFF. • Use the dim/bright bar to adjust the desired preset light level. • Valid Values = 0 to 100 (default 0)
• Tap the top of the paddle 6 times.
• Note: 0% or OFF disabled the preset light level and will instead use the last level - 0 = Memory Dim - Last dim state
The Locator LED will flash red/amber 3 times to confirm the selection.
• Hold the top of the paddle to exit. The Locator LED will quickly flash amber - 1 - 100 = Level
to confirm.
LED Dim Level Indicator Timeout
MINIMUM / MAXIMUM DIM LEVELS • Parameter No: 6, Length: 1 Byte
PATENTS • Valid Values = 0 to 255 (default 3)
Leviton Decora Smart Z-Wave devices have the ability to alter the minimum
TM ® LED DIM LEVEL INDICATOR TIMEOUT
This product is covered by U.S. Patent No. 8,664,886 and corresponding foreign patents. DIM/BRIGHT Bar Rocker Locator Leviton Decora Smart Z-Wave® devices have the ability to alter the LED dim level - 0 = Level Indicators Off
LED dim level to increase compatibility with LED bulbs as well as alter the maximum
indicator timeout. - 1 - 254 = Level Indicator Timeout (seconds)
BRIGHTEN: brightness to save energy.
COPYRIGHT AND TRADEMARK INFORMATION • Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator - 255 = Levels Always On
Tap the TOP half of the DIM/BRIGHT Bar – Lights will jump to the next brightness setting.
To change minimum dim level: LED will turn amber.
Decora is a registered trademark of of Leviton Manufacturing Co., Inc. Hold the TOP half of the DIM/BRIGHT Bar – Lights will brighten. Locator LED Status
• Enter Programming Mode by holding the top of the paddle for 7 seconds, the • Tap the top of the paddle 8 times.
Z-Wave and Z-Wave Plus are registered trademarks of Sigma Designs and its subsidiaries in the DIM: Locator LED will turn amber. • Parameter No: 7, Length: 1 Byte
• The Locator LED will quickly flash red. • Valid Values = 0, 254, 255 (default 255)
United States and other countries. Use herein of third party trademarks, service marks, trade names, Tap the BOTTOM half of the DIM/BRIGHT Bar – Lights will jump to the next dim • Tap the top of the paddle 5 times. • Use the dim/bright bar to adjust the speed of dimming using the chart below: - 0 = LED Off
brand names and/or product names are for informational purposes only, are/may be the trademarks setting. Hold the BOTTOM half of the DIM/BRIGHT Bar – Lights will dim. The Locator LED will quickly flash red and amber.

WEB VERSION
NOTE: When lights are OFF you can change the light level that the lights will turn • Tap the top of the paddle once. - 254 = Status Mode
of their respective owners; such use is not meant to imply affiliation, sponsorship, or endorsement.
ON to using the DIM/BRIGHT Bar. If there is a power outage, when the power is The Locator LED will flash amber. - 255 = Locator Mod
No part of this document may be reproduced, transmitted or transcribed without the express
restored, the lights will return to the last setting before the power interruption. • Use the dim/bright bar to adjust the minimum dim level. LED Value
written permission of Leviton Manufacturing Co., Inc. Load Type
• Hold the top of the paddle to exit. 7 (Top LED) No Timeout • Parameter No: 8, Length: 1 Byte
TECHNICAL SUPPORT AIR GAP To change maximum dim level:
6 240 Seconds • Valid Values = 0 to 2 (default 0)
• Enter Programming Mode by holding the top of the paddle for 7 seconds, the 5 30 Seconds - 0 = Incandescent
For additional information contact Leviton’s Technical Support at: On the dimmer only, engage the air-gap switch by gently 4 5 Seconds - 1 = LED
1-800-824-3005, DSsupport@leviton.com or visit Leviton’s website at www.leviton.com Locator LED will turn amber.
pulling out from the bottom of the DIM/BRIGHT Bar until 3 3 Seconds - 2 = CFL
• Tap the top of the paddle 5 times.
the bottom of the bar lifts completely out of the frame and
The Locator LED will quickly flash red and amber. 2 1 Second
FOR CANADA ONLY a click is heard (refer to Figure). LED's will turn OFF.
• Tap the top of the paddle 2 times. 1 (Bottom LED) Instant
This will stop power to the fixture to replace the bulb.
For warranty information and/or product returns, residents of Canada should contact Leviton in The Locator LED will flash red.
After servicing is complete, press the DIM/BRIGHT Bar Z-WAVE® ASSOCIATIONS
writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality Assurance • Use the dim/bright bar to adjust the maximum dim level.
back into place for normal operation. • Hold the top of the paddle to exit. The Locator LED will quickly flash amber to
Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at • Hold the top of the paddle to exit.
1-800-405-5320. Cleaning: Clean with a damp cloth. confirm. • Group Number: 1
DO NOT use chemical cleaners. • Maximum Nodes: 5
LOCATOR LED SETUP • Z-Wave PlusTM Lifeline: A NOTIFICATION frame is sent to
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS Gently pull out the nodes
Leviton Decora SmartTM Z-Wave® devices have a locator LED on the bottom of
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that from bottom in this association group when a Lifeline event occurs.
the paddle. The operation of the LED can be changed. FACTORY DEFAULT • All nodes in the association group receive notification of
this product at the time of its sale by Leviton is free of defects in materials and workmanship under
normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct Status Mode: LED On when the load is On: status changes.
INCLUSION TO A Z-WAVE NETWORK ®
The Locator LED is used to show the current state of the load: When removing a device from a network it is best practice to use the Exclusion
such defects by repair or replacement, at its option. For details visit www.leviton.com or call process. In situations where a device needs to be returned to factory default follow the
1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of Leviton Decora SmartTM Z-Wave® devices support two methods of inclusion. • Enter Programming Mode by holding the top of the paddle for 7 seconds, the
Locator LED will turn amber. following steps. A reset should only be used when a controller is inoperable or missing.
this product or reinstallation. This warranty is void if this product is installed improperly or in an When using a Z-Wave PlusTM certified controller choose Network Wide
Inclusion. If network wide Inclusion does not discover your device, please try • Tap the top of the paddle 4 times. • Hold the top of the paddle for a total of 14 seconds.
improper environment, overloaded, misused, opened, abused, or altered in any manner, or is
not used under normal operating conditions or not in accordance with any labels or instructions. traditional inclusion. The Locator LED will quickly flash green and amber. • After the first 7 seconds the LED turns amber. ADDITIONAL SUPPORTED CLASSES
• Tap the top of the paddle once. • The Locator LED will quickly flash red/amber after 14 seconds.
There are no other or implied warranties of any kind, including merchantability and fitness Network Wide Inclusion: The Locator LED will flash green 3 times to confirm the selection. • Release the the top of the paddle and the device will reset.
for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the Z-WAVE PLUS INFO POWERLEVEL
Network Wide Inclusion allows your device to be included into the network using
duration of any such implied warranty, including merchantability and fitness for a particular purpose, Locator Mode: LED On when the load is Off (Default): ASSOCIATION SWITCH MULTILEVEL
devices already in the network to assist with communication. Work your way from
The Locator LED is designed to easily find the dimmer in a dark room. If the setting ASSOCIATION GRP INFO BASIC
is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential the closest devices to the controller outward.
has been changes and you wish to return to the default operation.
EXITING PROGRAMMING VERSION SWITCH ALL
damages, including without limitation, damage to, or loss of use of, any equipment, lost • Enter Programming Mode by holding the top of the paddle for 7 seconds, the
• Enter Programming Mode by holding the top of the paddle for 7 seconds, the MANUFACTURER SPECIFIC SCENE ACTUATOR CONF
sales or profits or delay or failure to perform this warranty obligation. The remedies provided Locator LED will blink amber. Devices are programmed to automatically time-out of any
Locator LED will turn amber. CONFIGURATION SCENE ACTIVATION
herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise. • Tap the top of the paddle one time. settings after 20 seconds.
• Tap the top of the paddle 4 times. DEVICE RESET LOCALLY FIRMWARE UPDATE MD V2
The Locator LED will quickly flash green.
The Locator LED will quickly flash green and amber. HAIL
• The Decora SmartTM Z-Wave® device is ready to learn into the Z-Wave® network.
© 2018 Leviton Mfg. Co., Inc. DI-000-DZ6HD-02B
WARNINGS WARNINGS AND CAUTIONS
• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring! • Recommended minimum wall box depth is 2-3/4".
• TO AVOID FIRE, PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle, a motor, or a transformer operated appliance. • Use with compatible dimmable LED, CFL bulbs, incandescent or 120V halogen fixtures only. For a list of compatible LED and CFL bulbs refer to www.leviton.com.
• To be installed and/or used in accordance with electrical codes and regulations. • DO NOT mix bulb types when multiple bulbs are used with one dimmer. All bulbs shall be either LED; CFL or incandescent. Using the same make/model of each bulb will enhance dimmer performance.
• If you are unsure about any part of these instructions, consult an electrician. • Leviton recommends Z-Wave® technology in residential installations up to 7,500 sq/ft. Metal junction boxes may adversely affect network coverage. Communication is designed to pass through
• Save this instruction sheet. It contains important technical data along with testing and troubleshooting information which will be useful after installation is complete. interior materials, exterior materials are designed to reflect RF energy and may prevent communication to detached buildings.
• Use this device with copper or copper clad wire only. • Z-Wave® networking technology is designed for distributed communication. Large clustering of communicating devices in a centralized location (ie. a closet) is not recommended.
CAUTIONS NOTE: Dimmer may feel warm to the touch during normal operation.
• Use with incandescent, or 120V halogen fixtures only. Use a Leviton electronic low voltage dimmer to control electronic (solid state) low voltage transformers. NOTE: The Decora® DZ6HD dimmer is not compatible with standard 3-way or 4-way switches. It must be used with up to 4 Decora® Digital DD00R-DL remotes for multi-location dimming.
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.

INTRODUCTION INSTALLING DIMMER BY ITSELF Step 3 Preparing and connecting wires: Step 4a Single Pole Wiring Application: Step 4b 3-Way Wiring with DD00R Matching Remote
OR WITH OTHER DEVICES This dimmer can be wired using side wire terminal screws (with LED) Application:
Leviton’s Decora SmartTM Z-Wave® Dimmers are designed to or through backwire openings. Choose appropriate wire
communicate with each other via Radio Frequency (RF) to provide If installing the device in a single device application, proceed with the stripping specifications accordingly.
remote control of your lighting. In a Z-Wave® network, each device Matching Remote (with LED) Dimmer
INSTALLING YOUR DIMMER section. If installing Dimmer in a
is designed to act as a router. These routers will re-transmit the RF Neutral to Terminal
multi-device application, proceed as follows: Screw marked
Terminal
Screw marked
signal from one device to another until the intended device is reached. White (WH) White (WH)
This ensures that the signal is received by its intended device by MULTI-DEVICE APPLICATION 5/8" Terminal
routing the signal around obstacles and radio dead spots. This dimmer In multi-dimmer installations, the reduction of the dimmer’s capacity may Strip Gage Screw marked BK
WH
2
(1.6 cm) Black (BK) Terminal Terminal
is compatible with any Z-Wave® enabled network, regardless of the be required. Refer to the chart for maximum load per dimmer. (measure bare Screw Screw
marked 2 marked
manufacturer and can also be used with other devices displaying the NOTE: No derating is required for LED or CFL bulb applications. Cut wire here) RD
1
Black
BK
WH
Black
BK
WH
2
YL/RD 1
Z-Wave® logo. (if necessary) Terminal 4 (BK) (BK) 4
4
WARNING: TO AVOID FIRE, PERSONAL INJURY OR DEATH Screw marked 3 YL/RD
RD
YL/RD
RD
1
Terminal Terminal
DO NOT USE the remote for the control of high power heating Yellow/Red Screw 3 Screw 3
appliances such as portable heaters. There can be some unexpected (YL/RD) Terminal marked 5 marked 5
Screw marked Yellow/ Yellow/
consequences if not used with care. For example, an empty coffee pot Red (RD) Red Terminal Red Terminal
can be remotely turned on. If that should happen, your coffee pot could Terminal Label: (YL/RD) Screw marked (YL/RD) Screw marked
Use terminal for 3-way or more applications only. Red (RD) Red (RD)
be damaged from overheating. If an electric heater is turned on by For single-pole applications, DO NOT remove label.
remote control while clothing is draped over it, a fire could result. This
device will not control lighting that is used with electronic low-voltage
and high frequency power supply transformers, nor high pressure Side Wire Connection Back Wire Connection Matching Remote (w/LEDs)
Side wire terminals accept Back wire openings accept
Dimmer Dimmer
discharge lamps (HID lighting). This includes mercury-vapor, sodium
vapor and metal halide lamps. #14-12 AWG solid copper #14-12 AWG solid copper
Decora SmartTM Devices are ideal for living rooms, bedrooms, kitchens, wire only. wire only. WH BK Hot (Black) Hot (Black)
dining rooms, home offices, outdoor lighting or anywhere full control of BK
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE • Make sure that the ends of the wires from the wall box are WH BK WH
lighting is desired. straight (cut if necessary). RD YL/RD
Load Single Two Devices More than 2 Devices RD
• Remove insulation from each wire in the wall box as shown. Black Line Black
RATINGS Incand 600W 500W 500W • For Single-Pole Application, go to Step 4a. Insulating
120 VAC, YL/RD YL/RD
Label Line
• For 3-Way Matching Remote (with LEDs) Application, go to Step 4b. Load Green 60Hz 120VAC, 60Hz Load
Incandescent - 600W - 120VAC, 60Hz Ground
LED/CFL - 300W - 120VAC, 60Hz INSTALLING YOUR DIMMER Green Green
For non-standard wiring applications, refer White Ground Ground
White
FEATURES to Wire Connector and Conductor Size Chart
Neutral (White)
WIRE CONNECTOR / # OF COND. Neutral (White)
• Z-Wave Plus™ Certification Step 1 WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN COMBINATION CHART
• Increased communication range OFF POWER at circuit breaker or fuse and test that power
• Network Wide Inclusion is off before wiring! WIRING DIMMER: WIRING DIMMER
1 - #12 w/ 1 to 3 #14, #16 or #18 (wall box with load connection):
• Support for beaming and secure commands 2 - #12 w/ 1 or 2 #16 or #18 Connect wires per WIRING DIAGRAM as follows:
• Over The Air (OTA) updates NOTE: The DZ6HD dimmer requires a neutral connection.
Connect wires per WIRING DIAGRAM as follows:
1 - #14 w/ 1 to 4 #16 or #18
• Compatible with Leviton vizia rf+ systems 2 - #14 w/ 1 to 3 #16 or #18 NOTE: The DZ6HD dimmer must be installed in a wall box that has a Load
/&& /. /&& /.
• Green or bare copper wire in wall box to Green dimmer
• Soft fade ON/OFF connection. The dimmer also requires a neutral connection.
/&& /. /&& /.
terminal screw.
• ON/OFF LED and Brightness level LED /&& /. /&& /.
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot wall box wire to Black dimmer terminal screw.
• Three way communication /&& /. /&& /.
• Load wall box wire identified (tagged) when removing old switch to
/&& /. /&& /. • Load wall box wire to Red dimmer terminal screw.
• Ease of installation – No new wiring dimmer terminal screw marked "RD".
/&& /. /&& /. • Neutral wall box wire to White dimmer terminal screw.
• Yellow/Red dimmer terminal screw should have Red insulation • First Traveler Line Hot to dimmer terminal screw marked "BK".
TOOLS NEEDED TO INSTALL YOUR DIMMER label affixed. • Remove Red insulating label from terminal screw marked "YL/RD".
Step 2 Identifying your wiring application (most common): NOTE: If insulating label is not afficed to Yellow/Red dimmer • Second Traveler wall box wire (note color as above) to dimmer terminal
Slotted/Phillips Screwdriver Electrical Tape Pliers screw marked "YL/RD". This traveler from the dimmer must go to the
Pencil Cutters Ruler NOTE: If the wiring in your wall box does not resemble any terminal screw, use electrical tape to cover.
terminal screw on the remote marked "YL/RD".
of these configurations, consult an electrician. • Proceed to step 5.
Changing the color of your Dimmer: • Neutral wall box wire to White dimmer terminal screw.

WEB VERSION
Your dimmer comes with two color options. To change color of the face WIRING MATCHING REMOTE
proceed as follows: (wall box with Line Hot connection):
Connect wires per WIRING DIAGRAM as follows:
1 2
1 2 NOTE: The matching remote must be installed in a wall box with a Line
1
3
Hot connection and a Neutral connection. A Neutral wire to the matching
3 4 remote needs to be added as shown. If you are unsure about any part of
4 5 these instructions, consult an electrician.
NOTE: Maximum wire length from dimmer to all installed remotes cannot
exceed 300 ft (90m).
• Green or bare copper wire in wall box to Green terminal screw.
Single Pole 3-Way • Line Hot (common) wall box wire identified (tagged) when removing old
2 1. Line or Load switch and First Traveler to remote terminal screw marked "BK".
1. Line (Hot)
2. Neutral (see important • Second Traveler wall box wire from dimmer to remote terminal screw
Push in sides at bottom Insert top tabs and instruction) marked "YL/RD" (note wire color). This traveler from the remote must
tabs and pull outward to press in bottom tabs 3. Ground
release to attach 4. Load 2. Neutral go to the terminal screw on the dimmer marked "YL/RD".
3. Ground • Line Neutral wall box to remote terminal screw marked "WH".
4. First Traveler – note color
INSTALLING DIMMER BY ITSELF 5. Second Traveler – note color
NOTE: To synchronize LEDs between a Decora® digital remote and
OR WITH OTHER DEVICES the Decora® DZ6HD dimmer, a dim up or dim down command must be
IMPORTANT: For 3-Way applications, note that one of the screw terminals pressed on the remote.
If installing the device in a single device application, proceed with the from the old switch being removed will usually be a different color (Black)
• Proceed to Step 5.
INSTALLING YOUR DIMMER section. If installing Dimmer in a or labeled Common. Tag that wire with electrical tape and identify as the
multi-device application, proceed as follows: Common (Line or Load) in both the dimmer wall box and remote wall box.
DI-000-DZ6HD-02B

FCC COMPLIANCE STATEMENT FCC CAUTION


This device complies with Part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause • Reorient or relocate the receiving Antenna. Any changes or modifications not expressly approved by Leviton Manufacturing Co., Inc., could void the user’s authority to operate the equipment.
undesired operation of the device. This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful • Increase the separation between the equipment and the receiver.
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. IC COMPLIANCE STATEMENT
is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try • Consult the dealer or an experienced radio/tv technician for help. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may
to correct the interference by one or more of the following measures: not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

You might also like