STEP SVT - Tool
STEP SVT - Tool
L1 L2 L3 L4
F1 F2
F3
ENS ENTER
L1 L2 L3 L4
F2 calling could be conducted)
After pressing 2 times, Input occurs, but can not be modified.
ENS ENTER
1. Function selection & input storage
ENTER 2. Move to parameter window
2
Elevator Function Chart
ENTER
F1
Speed
速度曲线 Curve
ENTER Elevator Status
ESC
故障记录
Fault Record
ENTER
Para. F
井道数据
Shaft Data
Monintor
VERSION Main Para.
ESC ESC
输入输出
Input&output
============== Para. Setup
Parameter setup
Lift Model
Level Adj. 程序版本
08CDEQ02SO01
Level adjustment of overall floor Version
Call registration Call Func.
NSPB05OEK01D
Lvl. Micro Adj.
Level adjustment of each floor
Speed parameter S Curve
3
D1 D2 D3 D4
Initial menu
L1 L2 L3 L4
VERSION
==============
SVC-Tool software version
08CDEQ02SO01
NSPB05OEK01D Main-board software version
F1 F2
F3
1. Password is 1234
L1 L2 L3 L4
LOGIN
============== ▲ after pressing, cursor figure becomes larger
▼ after pressing, cursor figure becomes smaller
4
◀ after pressing, cursor moves to the left.
▶ after pressing, cursor moves to the right.
F1 F2
Input 1234 by methods mentioned above
F3
Normal Simplex
Normal
Indicates manual state
Simplex
Indicates simplex group running
=== 00000088 ===
1 Floor 0.00m/s === 00000088 === Running times are
indicated in
Door Locked
1 Floor
Indicates floor No.
0.00m/s
Indicates speed now
Door Locked
Indicates door-closing, door-opening, running
F1 F2
F3
After pressing F1 in picture
ENS ENTER mentioned above, error page could be
found.
6
D1 D2 D3 D4
Error display page
1. After pressing in following sequence in state display page
Fun. Select Monitor Monitor
F1 F2 Err. Info
8
Function select (Func. Select)
D1 D2 D3 D4
L1 L2 L3 L4 Monitor
L1 L2 L3 L4 Para. Setup
ENTER
After pressing , changed Data will be stored.
ENS ENTER
★ F0~F255, please refer to parameter sheet
10
No. Display picture Description Passenger num.1.5/17 Adjust range Unit
F00 Adjust starting acceleration Adjust starting acceleration 0.60 200-1500 mm/s2
F01 Adjust braking acceleration Adjust braking acceleration 0.60 200-1500 mm/s2
F06 Rated speed Rated speed 1.500 Based on field setup conditions mm/s
F07 Rated rotations of motor Rotation speed of motor 136 Based on field setup conditions Rpm
F08 Encoder Pulses Encoder Pulses 8192 Based on field setup conditions ppr
F09 Parking floor Set Parking floor 4 Based on field setup conditions
F11 No. of Floor Actual parking floor No. 12 Based on field setup conditions
F14 Door-closing delay for registrations Door-closing time after hall door call service 3.0 0-300 0.1s
F15 Door-closing delay for calls Door-closing time after car command service 3.0 0-300 0.1s
F16 Brake delay 1 When start, time for starting brake 0.2 0-20 0.1s
F17 Brake delay 2 When stop, time for stopping brake 0.6 2-30 0.1s
F18 Fire home In fire-fighting work, set home floor 4 Based on field setup conditions
F19 Second fire home(Not used yet) In fire-fighting work, the 2nd home floor 4 Based on field setup conditions
F22 Home landing position for automati If no external call-out, set homing time 4 Based on field setup conditions
c home landing return
F24 1
F25 Input Type 1(X0-X15 Input N/O, N/ Input X0~X15 open=0/close=1setup 12351 X0 X15
C setup) **--****----**--
1 2 4 8 16 32 64 128 256 512 1024 2048 4096 8192
16384 32768
F26 Input Type 2(X16-X31 Input N/O, N Input X16~X25 open=0/close=1setup 13184 X16 X32
/C setup) 11 **--****----**--
F27 Input Type 3(TX0-TX15 Input N/O, N/C setup) GX0 GX15
Input TX0~TX15 open=0/close=1setup 0
**— —****— — — —**— —
F28 Input Type 4(TX16-TX31 Input N/O, N/C setup) HX0 HX15
Input TX16~TX31 open=0/close=1setup 799
*****— — — ** — — — — — —
F33 Interval between trips in automatic running test Continuous running setup time 5 0-60 s
F34 Number of trips in automatic running test Setup continuous run times-input times, run trip for 1 time 0 0-65535 input times, run trip for 1 time
F36 Brake switch detection mode Brake switch detection mode 1 0-65535
F41 Load set Adjust load 1=0% Seting, 2=100% Seting executes at the After loading counter-weight device in car, press Enter to change into 0,
0
lowest floor and realize setup
F43 Buzzer & flashing at landing call by attendant s Buzzer &setup signal lamp0=none, 1=buzzer, 2=signal lamp **— — — — — — — — — — — — — —
ervice 3=buzzer, signal lamp, 4=waiting for open 3
(6could be combined)
F56 Leveling adjustment up(50 for baseline) Adjust up height(in adjust, please do not use stopping 2 pha mm
50 0-65535
se)
12
F57 Leveling adjustment down(50 for baseline) Adjust down height(in adjust, please do not use stopping
50 0-65535 mm
2 phase)
F58 Speed curve delay at start When start, time for opening brake and starting 0.5 0-250 0.1s
F59 Brake delay at zero speed Time for stopping and stopping brake 0 0-65535 0.01s
F61 Distance for triggering arrival gong Distance for level before triggering arrival bell rings 1200 0-65535 mm
F62 Time limit for anti-slippage operation In automatic-operating, level can not be detected in setup ti
32 20-45 S
me, check error
F63 3
F65-F112 Indication of floors Indicate floor No. 0-65535 indicates the floor No.
F114 30
F117 Holding time before forced door closing If button flashes continuously, it will forced to be closed in s
60 0-65535 S
etup time
F118 Holding time for the handicapped Time for the handicapped button door-opening 30 0-65535 S
F121 Forced door-closing enable Forced door-closing function (force to close door) 0 0-1
F122 Release direction delay during inspection ser Set time delay for brake contact point closes to indicating
3 0-65535 0.1s
vice lamp off
F123 Landing call classification Setup home page button 0-65535 0=door call-out 1=front 2=front-door the handicapped
0
call-out3=front-rear door the handicapped call-out
F124 60 0-1300
F125 60 0-1300
F128 Separate door control Setup front-rear door control separation 0:front door and rear door are controlled separately
0
1:control simultaneously
F129 Relevelling with door open and/or pre-door-o Whether it is executed when relevel door or before or after
0 0-65535
pening Enable. door-opening
13
F140 80 0-65535 %
F145 Bus voltage increases(if speed is slow, improve the value) 100 100-120 %
F147 0 0-65535
F152 Delay for car-lighting before automatically switc Setup lighting and FAN delay time 5 60s
0-65535
hing off car-lighting and fan
F155 Adjust broadcasting range 65533 If ATT ON, it is changed into 65533 after broadcasting
F156 Door lock and safe loop relay check enable Set to be KAD contact point 3 3
F160 Clearing error registrations manually enable Setup error which could be deleted and error which can not 1
0-65535
be deleted
F161 Setup that floor service is not performed within establishing 0 1:setup no 2:not designate floor
time
F162 3
F163 Setup to use stand-by power supply 0 0:after stand-by power supply return to proper hall, do not run
1:could run
F164 Load-weighing signal Setup input point for load measuring device 9 7:input point for load measuring device 02/I’s JP9.2
8: input point for load measuring device 02/I’s JP9.3
9: input point for load measuring device 02/I’s JP9.2 and JP9.3
F165 Door open selection in testing traveling When setup low-speed running, the door acts 0 0:open 1:close 3:not act
F168 Elevator numbering for IC card service Setup IC card service elevator unit 0 0-65535
F169 Setting landings for up/down calls by IC card When hoistway call-out, set IC card direction 0 0-65535 0:up 1:dn
F170 With IC control car. 1-16 FI. for selection of ide According to floor No., set car identification 0
0-65535
ntification by IC card
F175 Creeping speed at start When start, linkage speed (adjust comfortable sensation) 0.006 0-100 Mm/s
F181 Elevator numbering in duplex control Setup main machine, subunit 0 0-65535
F182 Steps of speed reduction switches Setup nums of deceleration switches 1 0-65535
F183 Speed at self-tuning When run for floor height inspecting, setup the speed 0.800 0-65535 mm/s
14
F186 Creeping speed at start Linkage time at start (adjust comfortable sensation) 0.50 0-65535 10ms
F187 Leveling induction calibration running At Svc-tool 0 0:running times nums1:encoder pulses (not excellent if higher
Setup monitoring at initial picture window. than1000) 2&3:can communicate (not excellent if over 96) 4:
rotation speed of motor 5:bus voltage 6:output current 7:output
rotation torque 8:magnetic pole position 9&10:encoder position
11:stand-by torque 12&13 radiator temperature 14:indicates load
15:indicates PTM1 16:indicatesPTM2
F193 Empty-load compensation at lowest landing Empty-load compensation at lowest floor 0 0-1000 0.10%
F194 Full-load compensation at lowest landing Full-load compensation at lowest floor 100.0% 0-1000 0.10%
F195 Empty-load compensation at top landing Empty-load compensation at top floor 0 0-1000 0.10%
F196 2nd main landing by duplex control The 2nd main hole controlled in duplex 0 0-64
F197-F199 3rd main landing by duplex control The 3rd main hole controlled in duplex
F201
F204 Zero speed proportion ASR P0 Adjust start compensation 100 0-655.35
F206 Low speed proportion ASR P1 Low speed proportion 110 0-655.35
F208 Low speed proportion ASR P2 Low speed proportion 110 0-655.35
F210 Medium speed proportion ASR P3 Medium speed proportion 120 0-655.35
F212 High speed proportion ASR P4 High speed proportion 140 0-655.35
F214 Low speed switchover frequency 1 Low speed switchover 0.5 0-15.00 Hz
F215 High speed switchover frequency 2 High speed switchover 25 15.00-50.00 Hz
F216 Current loop proportional gain Current loop proportional gain 5.0 It should be used when start with 0 speed, and applicable for 1387 si
gnal only.
F217 Zero speed servo time Setup brake time at stop 0.8 0-5.000 S
F218 Motor Type Motor Type 1 0-asynchronous;1-synchronous
F222 Rated motor current Rated motor current 26.9 0-80.00 inspect the motor A
F223 Max. output torque Max. output rotation torque 200 0-30 (200% 10s) %
15
F224 Motor slip frequency Motor slip difference frequency (adjust within 2
0~4.0 range)
F228 Magnetic pole phase Indicates phase angle at rated initial stage of 0
Magnetic pole phase synchro-motor
F232 Motor reversion When adjust start torque, change rotation direction of moto 1
r.
F240 30 In the condition of normal operating, applicable for 1387 signal only
F241 Adjust down start vibration, when F247 value is larger and 0-200
value is 100%, adjust down start
vibration.
F242 Adjust up start vibration, when F247 value is larger and val 0-200
ue is 100%, adjust up start vibration.
F245 Adjust down start vibration, when F247 value is small and 0-200
value is 0%, adjust down start
vibration.
★ Para. Setup sub-content - Level Adj – H0~H2 all floors height adjust parameters
- Main Para – F0~F254 all parameters
- Lvl Micro – 1~64 each floor height adjust parameters
- Lift Model – B0~B37 one side of building, basic information parameters
- S Curve – D0~D13 relevant parameters about speed curve - Input Type – I0~I3 input address parameters
- Motor Model – E0~E14 relevant parameters about motor - Service Flr – L0~L7 service floor setup parameters
- PID Adjust – C0~C14 encoder speed governor parameters
- Dr Open Allow – M0~M7 relevant setup parameters about front
- Flr Disp – K0~k47 floor display setup parameters door and rear door of each floor
- Test Run – T0~T3 continuous running setup parameters
- Upload to MB – upload parameters
- Dr Motor – G0~G3 car door motor setup parameters
- Dnload to OP – download parameters
16
Floor height measuring running
D1 D2 D3 D4
ENTER
After pressing , move to floor
height measuring mode picture
L1 L2 L3 L4
1. Keep running mode at car side in Normal state,
Func. Select machine room is changed into Inspection mode.
2. Press Shaft Teach Enter.
Call Func 3. Change Inspection mode of machine room into
à Shaft Teach Normal mode, and measure floor height after return to
the lowest floor automatically.
4. After about 3~5s
(height measuring speed is0.8m/s)
F1 F2 5. After up to the top floor, operating mode of machine
room should be changed from Inspection mode into
F3 Normal mode.
ENS ENTER
17
D1 D2 D3 D4
Load adjust
After pressing ENTER , move to F.Para
picture.
L1 L2 L3 L4
19
Description for main circuit board
High-voltage opto-
coupler isolation
input
PG Card
SW1= Off
Low-voltage opto-
Relay output coupler isolation
port input
Handset operator Modem Group CAN JP6: Working power supply input port of
port/community remote communicati Low-voltage opto-coupler isolation input
monitoring port monitoring Administration on port circuit and relay output circuit
port
20
Input content & setup
MIC ID No. Name Description Assembly
JP1.1 X0 When low speed mode signal 1 is converted to Normal,LED On Input / Default
JP1 JP1.2 X1 When low speed mode signal 2 is converted to Norma, LED On Input / Default
JP1.3 X2 When low speed mode UP running, LED On Input / Default
JP1.4 X3 When low speed mode Dn running, LED On Input / Default
JP2.1 X4 When upper deceleration switch 2LS acts, LED On Input/constant close
22