C a s t C o i l Tr a n s f o r m e r s
100 kVA to 30 MVA
2 3kV tto 34
2.3kV     34.5kV
             5kV
    Extraordinary Quality, Reliability and Service
                  Energy Efficient
               Low Total Owning Cost
           “ Proven World Class Leader”
“ World Class Cast Coil Transformers with Credentials”
 This brochure is an overview of why        Over      this  period,      we    have      value the opportunity to discuss your
 JST can qualify
              lif as your prime
                            i   source      d
                                            demonstrated
                                                     t t d a reliability
                                                               li bilit andd service
                                                                                 i       needs
                                                                                             d and d any other
                                                                                                          th questions
                                                                                                                     ti    you
 for Cast Coil Transformers. JST has        record of the highest level globally.        may have about JST Cast Coil
 served the North American market           This is the core of JST’s credentials.       transformers.
 since 1998 and brings extensive            We welcome the inspection of our
 experience of over 25 years serving        claims and comparison against any
 other major world markets.                 other sources. We appreciate and
Credentials              Related Comments                                                                        Re f. Pages
Experience record        -Over
                          Over 20,000
                               20 000 MVA installed in a diverse range of duty and in the most demanding         2
                         applications and environments
Standards and Designs    -Meets All US or IEC Standards                                                          3
                         -Proven “May Christie” technology
                         -Ratings through 15,000 kVA and 34.5kV
                         -185 ℃ / 115 and 80 ℃ rise; and 150 ℃ / 80 ℃ rise
Product Performance      -Meets or exceeds all standard and customer specifications                              3,4
Reliability              -A reliability record superior on a global comparison (99.9%)
Performance
Design and               -State of the Art, automated, design (CAD), core, coil, casting manufacturing and       5, 6, 7, 8
Manufacturing            testing systems.
Systems and Facilities   - Clean, orderly facilities, precise and consistent, cost effective
Quality Systems          -Philosophy… Highest possible quality standards followed throughout all operations      4,8
T ests and Certification -All C57.12.91 tests plus many optional tests
                         -Certification: ISO9001, ISO14001, KEMA
                         UL & cUL listed
Fit-Finish and Features - Superior by design and it shows                                                        9
Order/ Customer          -95% of quotes within 2 days                                                            10,11
Service
Product Service          -Competitive US factory and field service
Delivery Service         -Competitive lead times
                         -99% on-time delivery record
T otal
   t lOOwning
          i C Costt      “L
                         “Lowest
                               t T otal
                                    t l Owning
                                        O i Cost
                                               C t – Efficiency
                                                     Effi i     + all
                                                                   ll other
                                                                       th costs”
                                                                             t ”                                  11
(T OC)
  All add up to superior performance, and a high confidence level,
       critical in reliable application of Cast Coil Transformers.
JST Served Market… Experience
JST Cast Coil Transformers offer the ultimate in performance and reliability while serving the most severe and demanding
applications and environments
                 environments. Solid cast resin construction of primary and secondary coils have demonstrated superior
capability and exceptional reliability.
•Low installation cost – no need for liquid containment
•Withstand extreme impact and short circuit loads
•Impervious to Moisture, contaminants and other hostile environments
•Exceptionally long life with minimal maintenance
          Windpower                                       Airports                             Trains and Subways
          Universities                             Cast Coil Transformer                      Computer Data Centers
           Hospitals                                  Power Systems                               Office Buildings
Standard and Optional Ratings and Features
 Sizes Available kVA               150 300
                                   150, 300, 500
                                             500, 750
                                                  750, 1000
                                                       1000, 1250
                                                             1250, 1500
                                                                   1500, 2000
                                                                         2000, 2500
                                                                               2500, 3000
                                                                                     3000, 3250
                                                                                           3250, 3750
                                                                                                 3750, 5000
                                                                                                       5000, 7500
                                                                                                             7500,
                                   10000, 12000, 15000, 20000
 Primary Voltage Classes, kV       2.3, 5, 8.7, 15, 25, 34.5
 Secondary Voltage, kV             0.208, 0.24, 0.48, 2.4, 4.16, 6.9, 12.47, 13.2, 13.8
 Basic Impulse Levels
               Levels, kV                                            Standard                                    Optional
                             1.2                                            10                                     20,30
                             2.5                                            30                                        45
                             5.0                                            60                                        75
                             8.7                                            75                                        95
                             15                                             95                                       110
                             25                                            125                                       150
                            34.5                                           150                                       170
 Winding Temperature Rise, oC                                               80                                       115
 Impedance                         5.5% through 7.5% depending on HV, HV and LV ratings
 Forced Air Rating                                                       133%                                      140%
 300-15,000kVA
 Conductor Material                                                    Copper                                  Aluminum
                   Range oC
 Ambient Operating Range,                                -40
                                                          40 to 30 avg/40 max                                       to 50
Standard Features                                                             Options
•Windings Cast in vacuum in a mold                                            •Aluminum windings
•Copper windings                                                              •80Ԩ average temperature rise
•Step-lap mitered/cruciform core                                              •NEMA 3R, NEMA 4, stainless steel enclosure
•185Ԩ insulation system 115Ԩ rise                                             •Forced air cooling
•Four full capacity tap on HV winding rated 2 1/2%, 2-FCAN - FCBN on          •Three phase electronic temperature monitor
units with voltage above 601V                                                 •Higher BIL
•NEMA 1 heavy-gauge ventilated enclosure with removable panels                •Loss optimized designs (TOC)
front and rear                                                                •Humidity control / Heaters
•Provisions for lifting core and coil                                         •R-C Snubber
•Vibration isolation pads between core and coil and enclosure                 •Triplex Design
•Base equipped with Jack pads and designed for rolling or skidding in
any direction                                                                 Standard Certification
•Diagrammatic aluminum nameplate                                              •UL 1562
•Partial discharge free (< 10 pc@120% rated voltage)                          •ANSI C57.12.01, C57.12.91
                                                                              •ANSI ANSI N45.2-1977
                                                                              •NRC 10CFR50 Appendix B
                                                                              •ISO9001
                                                                              •NEMA std20
                                                                              •CSA Z 299.3
Quality and Reliability Assurance
Superior JST Cast Coil quality and reliability is the result of many key ingredients.
 Corporate          JST’s foundation is built on the fundamental philosophy that customer satisfaction and long-term
 Foundation         success depends on consistently supplying transformers on-time and of the highest possible quality,
                    and that will perform well and reliably in the most severe applications and environments.
 Standards &        Quality standards and practices per ISO 9001 are clearly documented, communicated and rigorously
 Practices          followed throughout all aspects of the business.
 Certifications
                        ISO9001                 ISO14001         OHSAS18001               KEMA                 UL
 Computer Aided      The most advanced computer aided design (CAD) systems are
 Design              operated by highly trained engineers, assuring accurate, optimized
                     designs, exact fit of all parts, plus providing programs for automated
                     core cutting and stacking, coil winding and testing.
 Highest Quality     All materials meet the highest standards with assurance per ISO 9001
 Materials           - Core steel of high efficiency, high permeability grain oriented silicon steel
                     - Insulation materials are used to meet UL certification
 State-of-the-Art    Automated, state-of-the-art manufacturing systems are used in all stages of production – core
 Manufacturing       cutting and stacking, coil winding and casting, assuring precise, consistent transformers, with high
                     efficiency,
                      ffi i      low
                                 l   losses
                                     l      and
                                              d noise
                                                   i
 Testing             Each transformer is 100% tested to assure compliance with all customer specifications and to all
                     US Standards per ANSI C57.12.91, and in accordance with ISO 9001 procedures.
 Routine Tests                                                                 Optional Tests
 •1. Polarity and phase-relation tests                                         • Temperature Rise
 •2. Ratio test                                                                • ANSI Impulse
 •3. Winding resistance measurements                                           • Sound Level
 •4. Separate-source AC withstand voltage test
 •5. Induced AC withstand voltage test
 •6. No-load loss and excitation current                                       Design Type Tests
 •7. Load loss and impedance                                                   • Short Circuit
 •8. Partial discharge measurements                                            • Seismic Qualifications
 •9. Insulation resistance measurements
 •10. Auxiliary control circuitry test
Core Manufacturing Process
State-of-the-art manufacturing           with CAD optimized designs. The design
systems are used throughout JST’s
                                JST s    process computerized automatic precision
                                         process,
entire operations. First is a detailed   cutting, stacking and handling, and the highest
computer aided design defining the       quality high permeability, grain oriented silicon
entire transformer and all of its        steel, all contribute to achieve a consistently
components in exact detail.              high core quality with the lowest possible losses
GEORG automated cutting and              and sound levels, and at an economic cost.
stacking line is computer programmed
                                                                                              3D CAD modeling insures parts fit
                                                                                              exactly prior to assembly
                Core Cutting Equipment                                             Core Stacking Equipment
Cruciform construction, nearly            stacking also assures minimal stress,              transferring along natural grain
round, enables minimal dimensions for     consistent quality with higher efficiency and      oriented lines, enhancing efficiency
lowest losses and optimal coil fit,       lower noise.                                       by reducing joint fringing, thereby
thereby optimizing total transformer      Mitered step-lap construction with                 reducing losses and exciting current
material utilization and operating        precision joints allow efficient flux              and yielding the lowest sound levels.
energy cost. Automatic, precise
                                  Core Assemblies                                                Mitered Step-lap construction
Coil Manufacturing Process
JST’s coils are produced with state-of-the-art, computer automated, winding and casting equipment from Germany using the
highest quality copper or aluminum conductor and insulation materials used in UL certified insulation systems
                                                                                                      systems.
 Stollberg secondary winding machine, is computer              Stollberg primary winding machine is computer controlled
 automated and features conductor under constant               and features controlled tensioning and precision wire laying
 tensioning, and precision, automated welding of copper or     ensuring consistently high quality coils.
 aluminum strip and LV terminal, ensuring consistently
 hi h quality
 high     lit coils.
                il
                                                                                       perfect, solid, void-free castings,
Casting is the most critical step for      process is made possible by a modern,       with the resin completely saturating
ensuring coil winding quality and          computer controlled, high capacity,         all of the insulation and tightly
integrity and the guarantee that a         casting system supplied by Hubers of        holding the winding in place,
transformer will perform reliably, long-   Germany, the most proven technology         assuring long-term reliable
term, under the most demanding             globally. This state-of-the-art vacuum      operations, under the most
applications and severe                    casting system employs static mixing,       crushing forces of short circuit and
environmental conditions. Extensive        a process that delivers a constant                           Di l t i iintegrity,
                                                                                       power surges. Dielectric     t it
testing and JST's extremely high           viscosity, uniform, gas free resin          important for basic impulse level
reliability record clearly demonstrate     mixture to pre-heated molds, which          (BIL) and lightning or switching
that JST's vacuum cast resin               are filled from the bottom, under           surge applications, is assured by
transformers meet all criteria for         vacuum, all in a climate-controlled         the solid resin block being
serving under the most demanding           room. Curing in time-temperature            impervious to moisture and
conditions. Consistency of the casting     controlled ovens results in                 environmental contaminants.
                                                                                      HV Coil
                                                                                                  Coil Cross-Section
         Hubers computer controlled casting system
                                                                                         Coil top view
Manufacturing Facilities...
Manufacturing Facilities...
Inspection of JST’s manufacturing facilities
clearly reveals key ingredients for
exceptional quality. Cleanliness throughout.
Strict attention to process and quality control
procedures. Planned, orderly flow.
Design and testing to either ANSI or IEC
specification. Extra protection for safe
shipment to customers around the world.
Features… Quality is Built In… . And It Shows
 JST’s
 JST’ transformers
             f       are known
                         k      for
                                f their
                                    h i superior Fit… .
                                              i Fi
 Finish … and Functionality.
 JST Core-Coil assemblies are designed for optimized
 performance and value. For greater cooling capacity needed
 in higher power transformers, axial ducts are added in HV
 coils providing more cooling surface thus enabling greater
 optimization. Photos show higher kVA ducted and lower kVA
 non-ducted coils.
 Coils are supported on the top and bottom with epoxy blocks,
 cushioned with resilient pads to permit expansion and
 contraction.
Upper jack-bolt assemblies provide uniform pressure to
contain coil movement. Details make JST’s transformers
better. For example, bottom coil blocks are pinned to the
lower core clamps to prevent them from shifting or falling out.
Top coil blocks are recessed to capture the jack-bolt plates.
T and
Top     d bottom
          b tt   blocks
                 bl k are machined
                                hi d tto provide
                                              id permanentt
“high-low space” separation of the coils, helping to maintain
consistent dielectric performance.
Fan superiority is also evident. Fans are constructed of
stainless steel and with squirrel cage air delivery system, and
can deliver up to 50% additional transformer capacity, the
highest in the industry.
                  We can comply with Buy America and ARRA requirements
                                                          WITNESS
                                                          TESTING
                                                             We can
                                                            provide
                                                           Witness
                                                            Testing
                                                          (including
                                                          all routine
                                                            tests) in
                                                               our
                                                          Carlstadt,
                                                          NJ facility
Cast Coil Specification Guide
1.0 General                                      National Electrical Manufacturer’s                 perform all ANSI required tests
The transformer shall be cast coil
                              coil, dry-         Association (NEMA) and the American                including impulse
                                                                                                              impulse, temperature rise
type construction, manufactured and              National Standards Institute (ANSI).               and sound level, and have at least
tested in accordance with applicable             Manufacturer shall be ISO certified,               five years experience.
industry standards prepared by the               have complete in-house capability to
2.0 Ratings
kVA, _______AA, ______ /______ AA/FA, _______/______ AA/FFA, Conductor & bus _______ copper or aluminum
Primary coils are vacuum cast with Secondary coils___ vacuum cast or ___ eNcast (hermetically sealed epoxy)
Primary volts_______ delta or wye connected, BIL ___kV, Phase __, Frequency _ _, Taps__ standard 2+/-
2.5%
2.5%_____other
            other
Primary terminals connect to __ customer cables inside transformer case, __ HV ATC, __ HV switch/ breaker, ___ busduct
Secondary volts ____ delta or wye connected, BIL ___ kV Impedance % __ standard tolerance), __+/-10% tolerance
Secondary terminals connect to __ customer cables inside transformer case, __ LV ATC, __ LV switchgear, __ busduct
Sound Level ____ dB (AA), ____/___ dB (AA/FFA or AA/FA) ____dB (standard)
Temperature rise 115°C, or 80°C, or 80/115°C with continuous 15% overload capacity without exceeding maximum
operating temperature,
Ambient temperature ____ °C , ____(standard 30/40 °C )
Special accessories ________________________________________________________________________________
Enclosure _________ Indoor (NEMA 1 or NEMA 2), or _________ Outdoor (NEMA 3R)
Total Owning Cost evaluation, ____ standard losses and efficiency or ____NEMA TP1 high efficiency rating or
Special loss evaluation @ ______% load, “A” or NL value $______ /kW, “B” or LL value $______/kW
3.0 Construction
3.1 HV & LV Coils                                The assembled core shall be braced with           air provisions shall include bus sized for the
The transformer shall be constructed of          heavy steel angle to provide uniform              maximum FA rating, and provisions for
individually cast, co-axially mounted,           clamping pressure. Core and clamping              mounting fans and controls.
primary and secondary coils. Primary coils       structure shall be coated with high               3.4 Enclosure
shall be wound with copper or aluminum           temperature enamel for environmental              As specified, a heavy gauge sheet steel
conductor as specified. High voltage taps        protection. The top and bottom of the coils       NEMA 1 indoor, NEMA 2 indoor
shall be provided on the front of the coils
                                        coils,   shall be supported on epoxy blocks
                                                                                 blocks,           drip-proof,
                                                                                                   drip proof, or NEMA 3R outdoor enclosure
2-2.5% full capacity above nominal (FCAN)        cushioned with resilient pads, to secure them     shall be supplied. The design shall permit
and 2-2.5% full capacity below nominal           while permitting them to expand under             the enclosure to be disassembled and
(FCBN), and are changed only when the            loading. Bottom coil blocks shall be pinned       reassembled, and the core-and-coil assembly
transformer is de-energized. Threaded brass      to bottom core clamps to prevent blocks           removed from its base in the field without
tap inserts imbedded in the epoxy and bolted     from moving. Manufacturer shall mark all          cutting or welding. Resilient pads mounted
solid tin-plated bus tap links shall be          bolted torque connections. The transformer        below the core-and-coil assembly shall
furnished. Drilled bus tabs extending            core and coil design and construction must        effectively dampen vibrations to the
through the epoxy are not permitted. High        be verified by short circuit testing on similar   transformer enclosure. Equip enclosures
voltage windings are cast in epoxy, in a         units, performed in accordance with the           with removable bolted panels on the front
mold, using pre-heat and vacuum cycles and       latest revisions of ANSI Standards                and rear for internal access. Indoor
a bottom injection filling process to assure     C57 12 01 and C57.12.91.
                                                 C57.12.01        C57 12 91                        ventilated openings or outdoor louvers shall
optimal saturation of the epoxy. The epoxy,      3.3 Accessories                                   comply with NEMA and NEC standards.
rated for the same temperature as the            Fan cooling, if specified shall increase base     The heavy steel enclosure base shall include
insulation system, shall be reinforced with      kVA rating by 33 1/3% on units up to              provisions for rolling, skidding, lifting, and
fiberglass. Secondary coils utilizing wire or    3750kVA and 25% on units over 3750kVA             jacking. A flexible grounding strap shall be
sheet conductor are wound separately, and        at the rated temperature rise. If 80/115°C is     used to visibly ground the core to the frame.
are either vacuum cast as the high voltage       specified, base ratings will increase 50% up      Enclosure finish shall be ANSI 61utilizing
coils or eNcast construction, a non-vacuum       to 3750kVA and 40% on units over                  dry powder, electro-static process.
process with oven cured epoxy layer to layer     3750kVA when operating at the maximum             4.0 Testing
insulation and epoxy caps on both ends of        temperature rise. Thermal sensors placed in       Testing shall comply with the latest
the coil. HV and LV coils shall be designed      tube wells adjacent to the leads of all three     revisions of ANSI C57.12.01 and ANSI
to operate in a 30°C average, 40° C              LV coils shall automatically regulate             C57.12.91. Each transformer shall receive
maximum ambient temperature in a 24-hour         forced-air cooling. Complete forced air           the following tests: Ratio, Polarity, Phase
period.                                          equipment includes flush mounted                  Relation, No Load Loss, Excitation Current,
3.2 Core & Coil Assembly                         three-phase electronic temperature                Impedance Voltage, Load Loss, Applied
The transformer core shall be designed to        monitor-controller with contacts for fan,         Potential, Induced Potential and Partial
maintain flux density well below saturation      alarm and trip function, fail safe maximum        Discharge test (for coils over 600 volt).
and consist of Grade M-5 (minimum), high         temperature recording, internal alarm with        Windings shall be tested for partial
permeability, grain-oriented, non-aging          automatic or manual reset, programmable           discharge at 120% of rated voltage, with 10
silicone steel. Core shall be step-lap,          fan exerciser feature and blackbox, bus sized     Pico-Coulomb maximum extinction level.
cruciform construction with mitered joints.      for the maximum FA rating, fans and control       Impulse, sound level, temperature and short
Too assure
     assu e reduced
             educed sou
                     sound d levels
                              e esa and
                                      d lowest
                                         o est   wiring.
                                                       g After exiting
                                                                     g the LV tube wells,,         circuit test results shall be available upon
                                                                                                                                              p
losses, core legs shall be insulated and         thermal sensors are to be routed in metal         request from previously tested similar
banded with stainless steel straps and top       conduit-tray to prevent damage. Plastic           designs.
and bottom core clamps shall utilize an          tie-wraps are not permitted for securing the
insulated through-core bolting process.          thermocouple. At a minimum, future forced
Transformer Selection
 Selecting the best transformer for an application requires consideration of several factors.
 • Choice between types
                  types, Liquid -filled,
                                -filled Dry-type
                                         Dry-type, or Cast Coil
 • Choice between transformer suppliers
 • Choice between price and total life cycle costs, as basis for purchase
 Choice between types:
 Choice between types is usually based on how and where the transformer is being applied, plus weight given to relative
 cost between types. Cast coil usually is the best choice where duty, and environment are most severe and where the
 highest confidence of reliable, long-term operation is critical. First cost of a cast coil is usually higher than other
 technologies, however this premium is offset by product advantages, superior operating performance, and lower operating
 costs .
 Choice between suppliers:
 Choice of supplier is highly influenced by relative price, plus some price allowance for how well suppliers compare in
 meeting customer specification, and in the degree of customer confidence in product reliability and overall service.
 However, increasingly, customers are becoming much more aware of the importance of evaluating total life cycle cost
 when choosing transformer type, and suppliers.
 Selection of transformer type and supplier based on Total Life Cycle Owning Costs (TOC)
 TOC is a combination of (First Cost or Price + Operating Costs). Operating Cost consist of all cost invoLVed from sourcing,
 through installation,
          installation insurance
                       insurance, maintenance; repair
                                               repair, cost of electrical losses related to transformer efficiency (normally
 referred to Cost of Losses or COL), and finally disposal at life’s end. Selection of transformer type and supplier based on
 TOC evaluation requires determination of the TOC for each transformer under consideration and then comparing TOC of
 each. Type and supplier with the lowest TOC and best reliability should win if TOC is the basis of selection.
 Cast Coil Transformer TOC Evaluation:
 When comparing cast coil transformers to other types, it becomes apparent that there are other economic advantages:
 1. Low installation cost – no dykes or walls for liquid containment or dry out procedure
 2. Very low maintenance – immune to moisture, fumes and most contaminated environments
 3. Superior operating safety – coils are flame retardant, with self extinguishing properties
 4. High reliability, low service downtime and repair. Superior strength and durability of solid epoxy resin castings
 ensure maximum dielectric, thermal, and mechanical performance and continuity under demanding operating
 conditions, like switching, lightning surges, short circuits and life cycle loading.
 5. Low disposal cost – no fluids to leak during operation and no fluids to dispose of at life’s end.
 6. Low insurance cost – associated with fire properties, and no fluid spill exposure
  Cast Coil Transformers win in more applications when relative performance is measured …
  In addition, JST cast coil transformers offer even more…
  Superior reliability – 99.9% +                               Worth… immeasurable for critical applications
  Standard core losses typically 20 to 25% lower.              Worth … 10-12% price advantage. (@$4/watt NLL)
  Higher FA performance 140% or more vs 133%.                  Worth… over 5% price advantage
  JST wins when efficiency, reliability and performance advantages are evaluated…