Instrument Used For Testing: Serial No Model Calibration On Calibration Due: 06/10/2021 Instrument Name Make

The air velocity test reports summarize testing conducted at M/s. Sabui Medical Stores (MFG) to determine average air velocity in clean zones. Testing was performed in various areas including the microbiology lab, filling area, and oral liquid manufacturing area. Results from each area showed average air velocities within specified requirements, demonstrating compliance. The tests were conducted using a calibrated anemometer and witnessed by engineering and quality assurance personnel.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
117 views4 pages

Instrument Used For Testing: Serial No Model Calibration On Calibration Due: 06/10/2021 Instrument Name Make

The air velocity test reports summarize testing conducted at M/s. Sabui Medical Stores (MFG) to determine average air velocity in clean zones. Testing was performed in various areas including the microbiology lab, filling area, and oral liquid manufacturing area. Results from each area showed average air velocities within specified requirements, demonstrating compliance. The tests were conducted using a calibrated anemometer and witnessed by engineering and quality assurance personnel.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

AIR VELOCITY TEST REPORT

PURPOSE TO DETERMINE THE AVERAGE AIR VELOCITY


To Determine the average supply airflow velocity in the Clean Zone
CUSTOMER DETAILS
M/s.Sabui Medical Stores (MFG)
3,Sardar Ghat Lane, Bhadreshwar Document No GMPLCS/SMS/AVT/21-22/B-001
Client
,Hooghly.
West Bengal. Test Reference ISO 14644 - 3
Area of Test Microbilogy Date of Test 13/09/2021
AHU No. AHU-01 Next Due Date 12/08/2022
INSTRUMENT USED FOR TESTING
Instrument Name : Fan Type Anemometer Make : LUTRON
Serial No : S.31568 Model : AM-4201
Calibration On : 07/10/2020 Calibration Due : 06/10/2021
OBTAINED TEST RESULTS
Average Surfac
Each Required
Air Velocity Readings in Air Flow e area Total Room Actual
Sr. Equipment Name / ID. FILTER Actual
FPM Velocity of CFM Volume ACPH
Supply Filter ID.No CFM ACPH Result
No No (Va) Filter
V1 V2 V3 V4 V5 FPM (Sq.ft) CFM CFM (cu Feet) ACPH ACPH

1 LAF ROOM SA-1 296 305 315 316 308 308 0.69 213 213 400 32 30 Pass

2 Air Lock Room SA-1 95 104 110 123 102 107 0.69 74 74 107 41 30 Pass

3 Incubator Room SA-1 285 245 305 322 225 276 0.69 191 191 355 32 30 Pass

INFERENCE The above test confirms Air Flow Velocity in above Specified Clean Zone is as per the Specified requirment

Test Conducted By Test Witnessed By Checked By

Mr Balaji ENGINEERING QA
M/s.GMP laboratories And Clean Room Solutions M/s.Sabui Medical Stores (MFG)
AIR VELOCITY TEST REPORT

PURPOSE TO DETERMINE THE AVERAGE AIR VELOCITY


To Determine the average supply airflow velocity in the Clean Zone
CUSTOMER DETAILS
M/s.Sabui Medical Stores (MFG) Document No GMPLCS/SMS/AVT/21-22/B-002
Client 3,Sardar Ghat Lane, Bhadreshwar
West Bengal. Test Reference ISO 14644 - 3
Area of Test filling Area Date of Test 13/09/2021
AHU No. AHU-02 Next Due Date 12/08/2022
INSTRUMENT USED FOR TESTING
Instrument Name : Fan Type Anemometer Make : LUTRON
Serial No : S.31568 Model : AM-4201
Calibration On : 07/10/2020 Calibration Due : 06/10/2021
OBTAINED TEST RESULTS
Average Surfac
Each Required
Air Velocity Readings in Air Flow e area Total Room Actual
Sr. Equipment Name / ID. FILTER Actual
FPM Velocity of CFM Volume ACPH
Supply Filter ID.No CFM ACPH Result
No No (Va) Filter
V1 V2 V3 V4 V5 FPM (Sq.ft) CFM CFM (cu Feet) ACPH ACPH

SA-1 1440 1200 1450 1350 1348 1358 0.21 285


1 filling Sealing Room 591 1633 22 20 Pass
SA-2 1498 1478 1465 1425 1406 1454 0.21 305

SA-1 1102 1240 1245 1240 978 1161 0.17 197


2 Oral Liquid (MFG) 352 940 22 20 Pass
SA-2 987 880 942 945 800 911 0.17 155

3 Passage SA-1 645 702 648 689 603 657 0.21 138 138 256 32 20 Pass

INFERENCE The above test confirms Air Flow Velocity in above Specified Clean Zone is as per the Specified requirment

Test Conducted By Test Witnessed By Checked By

Mr Balaji ENGINEERING QA
M/s.GMP laboratories And Clean Room Solutions M/s.Sabui Medical Stores (MFG)
AIR VELOCITY TEST REPORT

PURPOSE TO DETERMINE THE AVERAGE AIR VELOCITY


To Determine the average supply airflow velocity in the Clean Zone
CUSTOMER DETAILS
M/s.Sabui Medical Stores (MFG) Document No GMPLCS/SMS/AVT/21-22/B-003
Client 3,Sardar Ghat Lane, Bhadreshwar
West Bengal. Test Reference ISO 14644 - 3
Area of Test Microbilogy Date of Test 13/09/2021
Equipement ID No. SML/LAF/01 Next Due Date 12/08/2022
INSTRUMENT USED FOR TESTING
Instrument Name : Fan Type Anemometer Make : LUTRON
Serial No : S.31568 Model : AM-4201
Calibration On : 07/10/2020 Calibration Due : 06/10/2021
OBTAINED TEST RESULTS
Average Surfac
Each Required
Air Velocity Readings in Air Flow e area Total Room Actual
Sr. Equipment Name / ID. FILTER Actual
FPM Velocity of CFM Volume ACPH
Supply Filter ID.No CFM ACPH Result
No No (Va) Filter

V1 V2 V3 V4 V5 FPM (Sq.ft) CFM CFM (cu Feet) ACPH ACPH

SA-1 2400 2340 2354 2360 2208 2332 0.06 140


1 Bulk Manifacturing 276 832 20 20 Pass
SA-2 2350 2420 2300 2156 2145 2274 0.06 136

2 Change Room SA-1 512 542 572 480 542 530 0.17 90 90 240 23 20 Pass

3 Air Lock -1 SA-2 736 768 740 780 765 758 0.06 45 45 120 23 20 Pass

4 Air Lock -2 SA-1 1450 1502 1380 1465 1475 1454 0.06 87 87 224 23 20 Pass

5 Bottle Wash SA-1 1544 1624 1598 1456 1380 1520 0.06 91 91 280 20 20 Pass

SA-1 1440 1200 1450 1350 1348 1358 0.06 81


6 Filling Room 169 576 18 20 Pass
SA-2 1498 1478 1465 1425 1406 1454 0.06 87

INFERENCE The above test confirms Air Flow Velocity in above Specified Clean Zone is as per the Specified requirment

Test Conducted By Test Witnessed By Checked By

Mr Balaji ENGINEERING QA
M/s.GMP laboratories And Clean Room Solutions M/s.Sabui Medical Stores (MFG)
AIR VELOCITY TEST REPORT

PURPOSE TO DETERMINE THE AVERAGE AIR VELOCITY


To Determine the average supply airflow velocity in the Clean Zone
CUSTOMER DETAILS
M/s.Sabui Medical Stores (MFG)
Document No GMPLCS/SMS/AVT/21-22/B-004
Client 3,Sardar Ghat
West Bengal. Test Reference ISO 14644 - 3
Area of Test Microbilogy Date of Test 13/09/2021
Equipement ID No. SML/LAF/01 Next Due Date 12/08/2022
INSTRUMENT USED FOR TESTING
Instrument Name : Fan Type Anemometer Make : LUTRON
Serial No : S.31568 Model : AM-4201
Calibration On : 07/10/2020 Calibration Due : 06/10/2021
OBTAINED TEST RESULTS
Sr. Equipment Name / ID. Air Velocity Readings in Average Air Flow Acceptance Criteria
Supply Filter ID.No Result
No No V1 V2 V3 V4 V5 FPM FPM

Sampling Booth
1 F1 92 106 100 102 108 102 90 ± 20 % Pass
RLS/WH/RLAF/003

INFERENCE The above test confirms Air Flow Velocity in above Specified Clean Zone is as per the Specified requirment

Test Conducted By Test Witnessed By Checked By

Mr Balaji ENGINEERING QA
M/s.GMP laboratories And Clean Room Solutions M/s.Sabui Medical Stores (MFG)