Programmazione Quick Scan 6500 per ambiente Carrefour
Collegamento diretto a Beetle
Leggere le etichette delle pagine seguenti seguendo l’ordine indicato nell’elenco
seguente:
NB: Utilizzare le etichette di START e di END appartenenti alla stessa tabella del codice di
programmazione scelto.
1. Return Handheld to factory defaults
2. START
3. RS-232-Wincor Nixdorf
4. END
5. START
6. Expand UPC-A to EAN-13
7. END
8. START
9. Enable Pharmacode 39
10. END
11. START
12. Enable Interleaved 2 of 5
13. END
14. START
15. Enable Code 128
16. END
Symbologies
Symbologies
In addition to standard linear bar code symbologies, the PDF model of
the linear imager also reads 2-Dimensional stacked bar code symbologies
such as PDF417, Micro PDF 417 and EAN UCC Composite.
For more information plus a complete listing of available symbology
types, turn to the Symbologies chapter of this manual.
Linear Imager Settings
The linear imager is factory programmed for the most common terminal
and communications settings. If you need to change these settings, pro-
gramming is accomplished by scanning the bar codes in this guide.
In the programming chapters, factory default settings are indicated with
bold text and yellow highlighting. These defaults represent the settings
for the RS-232 standard interface. For a listing of defaults for other
interfaces, reference Chapter C, Default Settings, in the section titled Inter-
face Default Exceptions.
Return to Factory Defaults
Scan the two bar codes below to reset the imager (handheld) and Base
Station to factory settings. These bar codes can be used to return the
imager to a “known” working state when the present programming sta-
tus is not known, faulty, or suspect.
Return handheld to
factory defaults
Return Base Station to
factory defaults
³ P R O ! I C % %
Product Reference Guide 1-3
Interface Related Features
Interface Selection
START
STATE BARCODE
RS-232
Standard
RS-232
Wincor-Nixdorf
IBM 4683
Port 5B
IBM 4683
Port 9B
IBM 4683
Port 17
IBM USB
USB Keyboard
Keyboard
Wedge A
Keyboard
Wedge B
Keyboard
Wedge C
4-4 QuickScan® QS6500/QS6500 BT
Interface Selection
START
STATE BARCODE
Keyboard
Wedge Y
Wand
Emulation
END
Product Reference Guide 4-7
UPC-A
UPC-A — continued
START
STATE BARCODE
Disable UPC-A
Enable UPC-A
Don’t Send
Checksum
Send
Checksum
No Expansion
Expand UPC-A
to EAN-13
END
Product Reference Guide 6-3
Pharmacode 39
Pharmacode 39
The following options apply to the Pharmacode 39 symbology.
Disable/Enable Pharmacode 39
When this feature is disabled, the imager will not read Pharmacode 39
bar codes.
Leading ‘A’
When this option is enabled, a letter A is appended to the leading end of
Pharmacode 39 bar code data.
Scanned bar code data: 0123456789123
Resulting message string output: A0123456789123
START
STATE BARCODE
Disable
Pharmacode
39
Enable
Pharmacode 39
Disable
Leading ‘A’
Enable
Leading ‘A’
END
Product Reference Guide 6-73
Interleaved 2 of 5
Interleaved 2 of 5 — continued
START
STATE BARCODE
Disable
Interleaved
2 of 5
Enable
Interleaved
2 of 5
Disable
Checksum
Verification
Enable
Checksum
Verification
Disable
Checksum
Transmission
Enable
Checksum
Transmission
END
Product Reference Guide 6-91
Code 128
Code 128 — continued
START
STATE BARCODE
Disable
Code 128
Enable
Code 128
Disable
Checksum
Verification
Enable
Checksum
Verification
Disable
Checksum
Transmission
Enable
Checksum
Transmission
Disable Func-
tion Code
Transmission
Enable
Function Code
Transmission
END
Product Reference Guide 6-81