ABB Substation Automation Products and Systems
Your functions selection
             SPACOM
         Multipurpose and
        Special Application
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            SPAE 010/011
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        SPAF 340 C3
                                                                                                                                                                                                                                                                                                                                                                                    SPAU 110 C
                                                                                                                                                                                                                                                                                                                                                                                                 SPAU 121 C
                                                                                                                                                                                                                                                                                                                                                                                                              SPAU 130 C
                                                                                                                                                                                                                                                                                                                                                                                                                           SPAU 140 C
                                                                                                                                                                                                                                                                                                                                                                                                                                        SPAU 320 C
                                                                                                                                                                                                                                                                                                                                                                                                                                                     SPAU 330 C
                                                                                                                                                                                                                                                                                                                                                                                                                                                                  SPAU 331 C
                                                                                                                                                                                                                                                                                                                                                                                                                                                                               SPAS 120 C
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           SPAF 140 C
                                                                                                                                                                                                                                                                                         SPAJ 110 C
                                                                                                                                                                                                                                                                                                      SPAJ 111 C
                                                                                                                                                                                                                                                                                                                   SPAJ 115 C
                                                                                                                                                                                                                                                                                                                                SPAJ 131 C
                                                                                                                                                                                                                                                                                                                                             SPAJ 160 C
                                                                                                                                                                                                                                                                                                                                                          SPAJ 320 C
                                                                                                                                                                                                                                                                                                                                                                       SPAJ 321 C
         Protection Relays
21.05.1999
                                                                                                                                                                                                                                                                                         Your product selection
Protection and measurement
Type of faults                                       IEEE Device No.                    IEC Symbol                Protection function / measurement                                                                                                                                      Protection and measurement
Short circuits                                                 51                             3I >                Three-phase non-directional overcurrent, low-set stage                                                                                                                                                         X                         X            X
                                                         50 / 51 / 51B                      3I >> /               Three-phase non-directional overcurrent, high-set stage / blockable overcurrent (1                                                                                                                             X                         X            X
Short circuits, winding faults                                87H                            1 ∆I >               Single-phase, high-impedance differential current, low-set stage, instantaneous (2                                                                                                               X
                                                                                                                                                                                                                                                                                                                       (3
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            X
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                 (3
                                                              87H                           1 ∆I >>               Single-phase, high-impedance differential current, high-set stage, delayed (4                                                                                                                     X
Earth-faults, winding faults                                  51N                         Io > / SEF              Non-directional earth-fault, low-set stage, sensitive, In = 1 A and 5 A (only DT operation)                                                                                          X           X
                                                                                                                                                                                                                                                                                                                       (5                                  X
                                                              51N                             Io >                Non-directional earth-fault, low-set stage, coarse, In = 1 A and 5 A                                                                                                    X                                                                             X
                                                           50N / 51N                    Io >> / Io-o >            Non-directional earth-fault, high-set stage                                                                                                                             X            X                                                   X            X
                                                              67N                      Io >       / SEF           Directional earth-fault ,low-set stage, sensitive, In = 1 A and 5 A (only DT operation)                                                                                                                                                                                                                                                                       X
                                                              67N                          Io >>                  Directional earth-fault, high-set stage                                                                                                                                                                                                                                                                                                                       X
                                                              59N                            Uo >                 Residual overvoltage, low-set stage                                                                                                                                                                                                                                X                                                   X            X            X
                                                              59N                           Uo >>                 Residual overvoltage, high-set stage                                                                                                                                                                                                                               X                                                   X            X            X
                                                             87NH                        ∆Io > / REF              High-impedance differential earth-fault current, low-set stage, instantaneous (6                                                                                                                  X                                                                                                                                                                         X
                                                             87NH                       ∆Io >> / REF              High-impedance differential earth-fault current, high-set stage, delayed                                                                                                                         X
                                                                                                                                                                                                                                                                                                                       (5
Over / undervoltage                                              59                           3U >                Three-phase overvoltage, low-set stage                                                                                                                                                                                                                                                          (7                                     (7
                                                                                                                                                                                                                                                                                                                                                                                                              X                                      X
                                                                 59                          3U >>                Three-phase overvoltage, high-set stage
                                                                 59                            U>                 Single-phase overvoltage, low-set stage                                                                                                                                                                                                                                         X                                         (8
                                                                                                                                                                                                                                                                                                                                                                                                                                        X
                                                                 27                           3U <                Three-phase undervoltage, low-set stage                                                                                                                                                                                                                                                         (7                                     (7
                                                                                                                                                                                                                                                                                                                                                                                                              X                                      X             X
                                                                 27                          3U <<                Three-phase undervoltage, high-set stage                                                                                                                                                                                                                                                                                                         X
                                                                 27                            U<                 Single-phase undervoltage, low-set stage                                                                                                                                                                                                                                        X                                         (8
                                                                                                                                                                                                                                                                                                                                                                                                                                        X
Frequency                                                  81U / 81O                   f < / f > / df/dt          Load shedding and restoration, stages 1...4                                                                                                                                                                                                                                                                                                                                                            X
                                                           81U / 81O                   f < / f > / df/dt          Underfrequency or overfrequency incl. rate of change, stages 1...4                                                                                                                                                                                                                                                                                                                        X
Additional functions                                             25                        SYNC                   Synchro-check / voltage check, stages 1 and 2                                                                                                                                                                                                                                                             X
                                                                 68                        Io2f >                 Inrush detector (neutral current)                                                                                                                                                                                                        X            X
                                                                51C                    3IC > / (3UC>)             Three-phase overload (capacitors)                                                                                                                                                                                           X
                                                                51N                        I n-n >                Unbalance (capacitors)                                                                                                                                                                                                      X
                                                                 37                         3I <                  Loss of supply / undercurrent (capacitors)                                                                                                                                                                                  X
Type of measurement
Current                                                                                         3I                Three-phase current                                                                                                                                                                                            X            X            X            X
                                                                                                Io                Neutral current                                                                                                                                                         X            X            X                                      X            X                                                                                                       X
                                                                                               In-n               Unbalance current                                                                                                                                                                                                           X
Voltage                                                                                      3U / U               Three-phase / single phase voltage                                                                                                                                                                                                                                              X            X            X            X            X            X                                        X            X
                                                                                              Uo                  Residual voltage                                                                                                                                                                                                                                                   X                                                   X            X            X            X
Frequency                                                                                        f                System frequency                                                                                                                                                                                                                                                                                                                                                                          X            X
Recording                                                                                                         Transient disturbance recorder module SPCR, optional                                                                                                                                                                                        (9           (9                                                               (9        X               (9
                                                                                                                                                                                                                                                                                                                                                          X            X                                                                X                         X
Communication                                                                              Symbol                                                                                                                                                                                        Data Communication
SPA-bus communication                                ............................. .............................. .........................................................................................................................................                               X            X            X            X            X            X            X            X            X            X            X            X            X            X            X                           X             X
Man-Machine-Communication, display                   ............................. .............................. .........................................................................................................................................                               X            X            X            X            X            X            X            X            X            X            X            X            X            X            X                           X             X
Man-Machine-Communication, PC                        ............................. .............................. .........................................................................................................................................                               X            X            X            X            X            X            X            X            X            X            X            X            X            X            X                           X             X
General functions                                                                          Symbol                                                                                                                                                                                        General functions
Main / secondary setting                     .............................         .............................. .........................................................................................................................................                               X            X            X            X            X            X            X            X            X            X            X            X            X            X            X                           X             X
Remote setting                               .............................         .............................. .........................................................................................................................................                               X            X            X            X            X            X            X            X            X            X            X            X            X            X            X                           X             X
Selfsupervision                              .............................         .............................. .........................................................................................................................................                               X            X            X            X            X            X            X            X            X            X            X            X            X            X            X             X             X             X
Annunciating, event generating and value recording                                 .............................. .........................................................................................................................................                               X            X            X            X            X            X            X            X            X            X            X            X            X            X            X                           X             X
Measurement and parameter display            .............................         .............................. .........................................................................................................................................                               X            X            X            X            X            X            X            X            X            X            X            X            X            X            X                           X             X
Switching device status display              .............................         .............................. .........................................................................................................................................
Remote end binary signal transfer (HW)       .............................         .............................. .........................................................................................................................................
Binary signal interbay transfer (HW)         .............................         .............................. .........................................................................................................................................
                                                                                                                  (1
                                                                                                                       e.g. busbar protection, protection of transformer LV terminals
                                                                                                                  (2
                                                                                                                       e.g. short feeder, machine winding and simple busbar applications
                                                                                                                  (3
                                                                                                                       for short-circuit and earth-fault protection 3 units (1/phase) required
                                                                                                                  (4
                                                                                                                       e.g. alarming stage in simple busbar applications for measuring circuit supervision purposes
                                                                                                                  (5
                                                                                                                       one of these functions can be used in a single unit
                                                                                                                  (6
                                                                                                                       e.g. transformer and machine windings, short feeder and simple busbar applications
                                                                                                                  (7
                                                                                                                       single-phase operation selectable
                                                                                                                  (8
                                                                                                                       two low- and high-set stages available
                                                                                                                  (9
                                                                                                                       possible, if one relay module is omitted
    ABB Substation Automation Oy                                                                                                                                                                                                                                                                                                                                                                                                                                                                    Page 1