Magellan™
Router Control Panels
               The Harris® Magellan™ family of router control panels (RCPs) provides a fast, powerful
               and simple way to control your Harris or third-party routing systems. Available as a series
               of 10 programmable hardware panels in 1 or 2RU versions, Magellan RCPs offer intuitive,
               Web-based configuration — enabling the industry’s fastest setup for both local and
               remote operations.
               These feature-rich, cost-effective and highly customizable panels — ranging from simple,
               button-per-source, single-bus panels to multilevel, multibus, relegendable LCD-button
               panels — are sure to meet both your budget and routing operational requirements.
               Designed with an understanding of the physical layout of a typical facility or OB truck,
               these compact RCPs — less than 2 inches deep — integrate easily into console-mount or
               any other space-constrained environment, enabling you to rapidly optimize the navigation
               and control of your routers.
       FEATURES
                  ▪ Supports button-per-source (BPS), multibus, XY and enhanced grouping modes
                  ▪ Ability to reconfigure and reassign buttons and alias names both on panel front and at configuration GUI
                  ▪ Compact and less than 2-in. (51 mm) deep, ideal for console-mount applications
                  ▪ Supports Ethernet and coaxial connections
                                      ◦ Ethernet supports both LRC (recommended) and XY protocols
                                      ◦ Coaxial supports XY only (use these systems without a Platinum™ router or for legacy
                                        routers)
                  ▪ Common control sections
                  ▪ Web-based configuration for easy and fast setup
                  ▪ Unicode support
                  ▪ Template-based to facilitate quick configuration changes either at the panel or through the web
                  ▪ Automatic update of routing tables — no need for downloads
                  ▪ Parametric control of all Platinum modules for seamless router integration
       PRODUCT DETAILS
Magellan                                                  1                                          www.broadcast.harris.com
           Magellan RCP LCD+OLED Display
            • Available in 1 and 2RU versions
            • Completely programmable and relegendable LCD buttons standard
            • Template-driven to facilitate easy panel layout changes
            • Generation of automatic updates for source, destination, and salvo additions, deletions and name
              changes
            • Ability to create local salvos and aliases
            • Provides unicode support
            • Configurable to operate in Cat/Idx mode or enhanced button-per-source
           Magellan RCP Push-button+OLED Display
            • Available in 1 and 2RU versions
            • Completely programmable rubber pushbuttons standard
            • Template-driven to facilitate easy panel layout changes
            • Capable of fast and intuitive operation
            • Follow/breakaway support
            • Ability to view and switch all levels of the router
            • Configurable to operate in Cat/Idx mode, multibus or single-bus mode
           Magellan RCP LCD Only
            • Available in 1 and 2RU versions
            • Completely programmable and relegendable LCD buttons standard
            • Ability to create local salvos and local aliases
            • Generation of automatic updates for source, destination, and salvo additions, deletions and name
              changes
            • Ability to switch router via status name, long name and aliases
            • Unicode support
            • Configurable to operate in Cat/Idx mode or enhanced button-per-source
           Magellan RCP Push-button Only
            • Available in 1 and 2RU versions
            • Completely programmable rubber push buttons standard
            • Fast and intuitive operation
            • Follow/breakaway support
            • Button-per-source configuration with ability to page to more sources and destinations
            • Support for button-per-source, single-bus and multibus applications
Magellan                                              2                                       www.broadcast.harris.com
       IMAGES/DIAGRAMS
               RCP-24LCD-OLED
               RCP-48LCD-OLED
               RCP-32PB-OLED
               RCP-64PB-OLED
               RCP-16LCD
               RCP-32LCD
               RCP-64LCD
               RCP-16PB
Magellan                        3   www.broadcast.harris.com
                     RCP-48PB
                     RCP-96PB
       SPECIFICATIONS
                     Specifications and designs are subject to change without notice.
       RCP-24LCD-OLED
       Number of Buttons               24 LCD plus 8 programmable function keys
       Operation Modes                 Button-per-source, XY, grouping, single-bus, multibus, breakaway
       Communications Ports            Ethernet and loop-through coaxial
       Protocols Supported             LRC (Ethernet only), XY (coaxial and Ethernet)
       Dimensions (W x H x D)          19 x 1.75 x 1.75 in. (48.3 x 4.4 x 4.4 cm)
       RCP-48LCD-OLED
       Number of Buttons               48 LCD plus 16 programmable function keys and 2 control knobs
       Operation Modes                 Button-per-source, XY, grouping, single-bus, multibus, breakaway
       Communications Ports            Ethernet and loop-through coaxial
       Protocols Supported             LRC (Ethernet only), XY (coaxial and Ethernet)
       Dimensions (W x H x D)          19 x 3.5 x 1.75 in. (48.3 x 8.9 x 4.4 cm)
       RCP-32PB-OLED
       Number of Buttons               32 push buttons plus 8 programmable function keys
       Operation Modes                 Button-per-source, XY, multibus, single-bus, breakaway
       Communications Ports            Ethernet and loop-through coaxial
       Protocols Supported             LRC (Ethernet only), XY (coaxial and Ethernet)
       Dimensions (W x H x D)          19 x 1.75 x 1.75 in. (48.3 x 4.4 x 4.4 cm)
       RCP-64PB-OLED
       Number of Buttons               64 push buttons plus 16 programmable function keys and 2 control knobs
Magellan                                                      4                                        www.broadcast.harris.com
       Operation Modes          Button-per-source, XY, multibus, breakaway
       Communications Ports     Ethernet and loop-through coaxial
       Protocols Supported      LRC (Ethernet only), XY (coaxial and Ethernet)
       Dimensions (W x H x D)   19 x 3.5 x 1.75 in. (48.3 x 8.9 x 4.4 cm)
       RCP-16LCD
       Number of Buttons        16 LCD plus 8 programmable function keys
       Operation Modes          Button-per-source, XY, grouping, single-bus, multibus, breakaway
       Communications Ports     Ethernet and loop-through coaxial
       Protocols Supported      LRC (Ethernet only), XY (coaxial and Ethernet)
       Dimensions (W x H x D)   19 x 1.75 x 1.75 in. (48.3 x 4.4 x 4.4 cm)
       RCP-32LCD
       Number of Buttons        32 LCD plus 8 programmable function keys
       Operation Modes          Button-per-source, XY, grouping, single-bus, multibus, breakaway
       Communications Ports     Ethernet and loop-through coaxial
       Protocols Supported      LRC (Ethernet only), XY (coaxial and Ethernet)
       Dimensions (W x H x D)   19 x 1.75 x 1.75 in. (48.3 x 4.4 x 4.4 cm)
       RCP-64LCD
       Number of Buttons        64 LCD plus 16 programmable function keys
       Operation Modes          Button-per-source, XY, grouping, single-bus, multibus, breakaway
       Communications Ports     Ethernet and loop-through coaxial
       Protocols Supported      LRC (Ethernet only), XY (coaxial and Ethernet)
       Dimensions (W x H x D)   19 x 3.5 x 1.75 in. (48.3 x 8.9 x 4.4 cm)
       RCP-16PB
       Number of Buttons        16 push buttons plus 8 programmable function keys
       Operation Modes          Button-per-source, single-bus, multibus, breakaway
       Communications Ports     Ethernet and loop-through coaxial
       Protocols Supported      LRC (Ethernet only), XY (coaxial and Ethernet)
       Dimensions (W x H x D)   19 x 1.75 x 1.75 in. (48.3 x 4.4 x 4.4 cm)
       RCP-48PB
       Number of Buttons        48 push buttons plus 8 programmable function keys
       Operation Modes          Button-per-source, single-bus, multibus, breakaway
       Communications Ports     Ethernet and loop-through coaxial
       Protocols Supported      LRC (Ethernet only), XY (coaxial and Ethernet)
       Dimensions (W x H x D)   19 x 1.75 x 1.75 in. (48.3 x 4.4 x 4.4 cm)
       RCP-96PB
Magellan                                               5                                       www.broadcast.harris.com
       Number of Buttons           96 push buttons plus 8 programmable function keys
       Operation Modes             Button-per-source, single-bus, multibus, breakaway
       Communications Ports        Ethernet and loop-through coaxial
       Protocols Supported         LRC (Ethernet only), XY (coaxial and Ethernet)
       Dimensions (W x H x D)      19 x 3.5 x 1.75 in. (48.3 x 8.9 x 4.4 cm)
       ORDERING INFORMATION
       RCP-24LCD-OLED           1RU control panel with 24 LCD buttons and OLED display and 8 function keys
       RCP-48LCD-OLED           2RU control panel with 48 LCD buttons and OLED display and 16 function keys
       RCP-32PB-OLED            1RU control panel with 32 push buttons and OLED display
       RCP-64PB-OLED            2RU control panel with 64 push buttons and OLED display and 16 function keys
       RCP-16LCD                1RU control panel with 16 LCD buttons and 8 function keys
       RCP-32LCD                1RU control panel with 32 LCD buttons and 8 function keys
       RCP-64LCD                2RU control panel with 72 LCD buttons and 16 function keys
       RCP-16PB                 1RU control panel with 16 push buttons and 8 function keys
       RCP-48PB                 1RU control panel with 48 push buttons and 8 function keys
       RCP-96PB                 2RU control panel with 96 push buttons and 16 function keys
Magellan                                                  6                                      www.broadcast.harris.com