We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 4
the best in ndt
Digital Ultrasonic Flaw Detector
DIGISCAN DS-324
Direct Access Function Keys, Easy to Operate
Rugged Engineering Metal Body with EMI Suppression
Highest Reserve Gain in its Category of Machines
Large A-Scan Display Area with Parameter value
Sharp- Display, Minutes Echoes
Optimized Performance for Higher Scanning Speed
‘Smooth DAC Curves, User Selectable Values for two Additional Curves
Universal DGS
Through Coating Thickness Measurement
Pen Drive, Ethernet Port for Data TransferKey Feature:
+ Unique Technology with an inbuilt Flaw siting Universal DGS
« Highest Reserved Gain Flaw Detector in its category of equipment
+ Improved Sil ratio with advance hardware
+ User friendly interactive architecture
+ Direct data transfer through Pen Drive
+ AScan recording
+ Simplified, easy to access navigation key
“Tough, Light Weight & durable Industrial grade body
+ Large, bright, crystal clear CRT grade display
+ Standard Dynamic DAC for flaw sizing
+ Lion battery
‘The New Generation Ultrasonic Flaw Detector DIGISCAN DS-324 combines EECI's years of experience & commitment to
customers, to provide the best flav? detector in its category by way of most advanced Technology, Convenience,
Uniqueness, Affordability & Technical options forultrasonicapplicationsinthe market
‘The TFT colored display makes the A-scan representation stable ond clearin all types of lighting condition. Equipped with
inbuilt Highest Reserved Gain and Universal DGS, makes DIGISCAN DS-324.a complete solution in ultrasonic testing, The
Rugged, Lightweight, Ergonomical design enables the operator touse DIGISCAN 0S-324inanyenviranmental conditions.
Display
* The DIGISCAN DS-324 provides a LCD (320 x 240 pixels) display resolution
* The display is unique in its category, providing excellent A-Scan representation and readability of
minute features of the signal
* The display also incorporates 4 colors Schemes & grids/ graticule pattern to suit all type of individual
‘operator levels/ preference
* Zoom function makes each and every minute echoes visible to the userStandard Features
A Scan Pattern
‘The inbuilt advance hardware enhances SiN ratio, far user to view each &
‘every minute echoes. It enhances the near & far surface resolution,
Highest Reserve Gain
‘Coupled with high S:N ratio the instrument has better ability to detect
smaller defects while retaining maximum unused gain (reserve) \
Universal DGS >
Features the Universal DGS pattern against standard DGS curve for a
[particular type of probe, It ean be plotted by choice of reflector type option
Include BW, SDH, FBH. Flaw size cccurring above or below the curve I easily
ible in parameter
‘MBIEIG In parameters Penetration in highly attenuate material
Inbuilt DAC
‘Calculates & displays tolerance curves in dB levels compared to DAC
reference curve with minimum 2 points & maximum 10 points, DAC is
[plotted as per user application, Smooth DAC curve appears on screen with
offset levels.
A-Scan Recorder
Data Transfer EECOWIN software
EECOWIN software enables data transfer from DS-324 to PC with its simple
[process of A frames, A-Scan pattern are directly transfer to PC through
EECOWIN software, Data transfer is also done through pen drive, Allthe
data can be transferred directly to Pen drive.
PC ConnectivitySPECIFICATIONS;
LCD DISPLAY
Display TET calgur LED with CFL backlight, 900 %:200
pina, 117-2am¥) X68mm(+)
Pal density 120 X R.G.B(H) 2400).
Display toaze (Curent pay toazad.
‘Active tree Cisplay accumulation
Reference Echo pattem elerence pam cane dyed atthe
background trem selected location in momar.
Display Pater Unfit or fied. (seleciabie trough set up menu
ss wel as acho display hoy)
PULSER / RECEIVER
Recelver bandwidth 9.5 fe 0 MH by wide bend amoiter,
Gain 0.8008, 0.1, 05.1.2, 6, 1238 Selectable:
Rejection nee type (0-595), 1% sep, parol ejection
(025%) 1% sep.
Operating mode Sing probe, souble probe.
Test made Fulsereflacion or puse Wancmiasion
Eneray HULOW selectabe,
Damping NORM sekoctabie
Vertical linearity 5% (22.5%)
Probe connesior BNC type
Echo display Full wave rece.
TIME BASE
Range ‘Sem min.-SMus. Max (@ 890M sec)
Continuous Varisbe,
(G.tma atop for 10-1600,
‘iam step for 100enm-SMt.)
Delay 0-3 Mire. Continuous Variable
-{0.0%evm sta fe 10-100ru-
(O.tmm step for 100mm. thre.
Aimmtep for T-Sh)
PRE ‘Auto set for optimum value. Manually
‘eloctabio fora lowor PRF in therange of
SDH2 (0 100} instep of 10H?
Velocity 000M /see-S999Msee
‘Time base tinearity 1% (20.5%)
Zoom Gates pertion, min, 1mm
Triggering leteenet
Probe Zero 0-99.99
MONITOR GATE
MonitorGates —-2.Gauss
Wid 1/10 screen to fll seroon
“Height 10 serean to 905,
“Gate slat rosasured fom di
‘logic seleciable
FLAW SIZING
Dac 1G pcinis auto pling curve, (min? points)
‘lara function irked to gate 2
‘Simultaneous? asaonal curves with
‘seletnd attenuation ie.
Between + 68 To-2008, In 168: Step.
‘go cave types a:
‘Expect
Paratoic
Print Te Point
4 1STD + offet2 curves th (Rel + xx dB)
Universal DS Diagram For Normal /R prabes. Ange probes.
GENERAL
Trigenamettic Functions. eam path, taw capt & prpcon
Measurements
Graticule
Dimension
Power Source
Battery indicator
Operating Temperature
Parameter display
Acconsoriee
Lock
Brightness
Alarm
Charge Indicators
disterce display or slate echo win gue 4
‘Ang slactin 0-99"
eb tikows selection Di $60
Echo Het 110% Tolerance
Thick (ee Toto) 4. rm
wuinesr
80 Marry Ses Wth’K Scans Fanes, Catraion
Parenaters,Thgenomadte Valu, Lab 1 Tg)
190 Calera Paranto ats
ABODAG Sets
PC comme va USB-B
‘Pen ive connect vin USA
Recerde ou PAL
EEOOWINPC inetcesotware compas with Wircows
(ti. Can upload scan saved eto PC and Pencve
thos the USE Pet
set ony iB dest seest in reguery wie nso,
‘Selcable ey ar tack bacon
Beeigrund ey
‘rse-naotiol yee
Seainiecatied parry
aaa is
Bocaprunstisck
“raced yloulreen
Gite & gue Rta cabs
Brotindeqrenlsniiyaon ik
$d x 5 (ter ub chided
ine 10 smal isn two type fstab grat vi
stand and CRT
AML) x BBC TSH)
2aKg.
“Suit bana pack, on
Rechageable baer model BATS22L
Darang tna hes wt batary
Batecy charger cam
‘sto zaneso eon sing ocr
Mota ADSYS eargeria ae
-Banecy charger level ca LCO cipiy.
Auto ution whee charged.
owssc.
Harz &Verical Graco, Gain, Uiversal DGS (aw Sz)
Beamgat, Faw Degth/ Thicke, Prete Ditiare,
Veloce ota Ange, Thckest, Echo Opa. DAC,
Probe Zoo. Delay. Range. Rec. Daeg. Ee.
Ga Gee ON/OFF, Gate uh, Gate Wich, Gate Haight,
‘arm Mut, Zoom, Foes, ceo Frowza Lock,
Contigo Maru, Nessary Sa, Mary Recs, Send
Bay
target
Pestle
canbe ocd
‘jab (0-100 1% Sep)
Ati val (sate me)
Geeen LED chang.
ELECTRONIC & ENGINEERING CD. (1). P. Lo
BEE ee eevee rn si
the best in ndt — cms:nesieascndacons Wet: wwwstentaron
ago Oc: ONENNAL BANGALORE ROLEADA HYDERABAD PUNE, PATWA, NAGPUR, MEW DEL NADODARA