0% found this document useful (0 votes)
95 views4 pages

Digiscan DS 324

Uploaded by

TYO WIBOWO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
95 views4 pages

Digiscan DS 324

Uploaded by

TYO WIBOWO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 4
the best in ndt Digital Ultrasonic Flaw Detector DIGISCAN DS-324 Direct Access Function Keys, Easy to Operate Rugged Engineering Metal Body with EMI Suppression Highest Reserve Gain in its Category of Machines Large A-Scan Display Area with Parameter value Sharp- Display, Minutes Echoes Optimized Performance for Higher Scanning Speed ‘Smooth DAC Curves, User Selectable Values for two Additional Curves Universal DGS Through Coating Thickness Measurement Pen Drive, Ethernet Port for Data Transfer Key Feature: + Unique Technology with an inbuilt Flaw siting Universal DGS « Highest Reserved Gain Flaw Detector in its category of equipment + Improved Sil ratio with advance hardware + User friendly interactive architecture + Direct data transfer through Pen Drive + AScan recording + Simplified, easy to access navigation key “Tough, Light Weight & durable Industrial grade body + Large, bright, crystal clear CRT grade display + Standard Dynamic DAC for flaw sizing + Lion battery ‘The New Generation Ultrasonic Flaw Detector DIGISCAN DS-324 combines EECI's years of experience & commitment to customers, to provide the best flav? detector in its category by way of most advanced Technology, Convenience, Uniqueness, Affordability & Technical options forultrasonicapplicationsinthe market ‘The TFT colored display makes the A-scan representation stable ond clearin all types of lighting condition. Equipped with inbuilt Highest Reserved Gain and Universal DGS, makes DIGISCAN DS-324.a complete solution in ultrasonic testing, The Rugged, Lightweight, Ergonomical design enables the operator touse DIGISCAN 0S-324inanyenviranmental conditions. Display * The DIGISCAN DS-324 provides a LCD (320 x 240 pixels) display resolution * The display is unique in its category, providing excellent A-Scan representation and readability of minute features of the signal * The display also incorporates 4 colors Schemes & grids/ graticule pattern to suit all type of individual ‘operator levels/ preference * Zoom function makes each and every minute echoes visible to the user Standard Features A Scan Pattern ‘The inbuilt advance hardware enhances SiN ratio, far user to view each & ‘every minute echoes. It enhances the near & far surface resolution, Highest Reserve Gain ‘Coupled with high S:N ratio the instrument has better ability to detect smaller defects while retaining maximum unused gain (reserve) \ Universal DGS > Features the Universal DGS pattern against standard DGS curve for a [particular type of probe, It ean be plotted by choice of reflector type option Include BW, SDH, FBH. Flaw size cccurring above or below the curve I easily ible in parameter ‘MBIEIG In parameters Penetration in highly attenuate material Inbuilt DAC ‘Calculates & displays tolerance curves in dB levels compared to DAC reference curve with minimum 2 points & maximum 10 points, DAC is [plotted as per user application, Smooth DAC curve appears on screen with offset levels. A-Scan Recorder Data Transfer EECOWIN software EECOWIN software enables data transfer from DS-324 to PC with its simple [process of A frames, A-Scan pattern are directly transfer to PC through EECOWIN software, Data transfer is also done through pen drive, Allthe data can be transferred directly to Pen drive. PC Connectivity SPECIFICATIONS; LCD DISPLAY Display TET calgur LED with CFL backlight, 900 %:200 pina, 117-2am¥) X68mm(+) Pal density 120 X R.G.B(H) 2400). Display toaze (Curent pay toazad. ‘Active tree Cisplay accumulation Reference Echo pattem elerence pam cane dyed atthe background trem selected location in momar. Display Pater Unfit or fied. (seleciabie trough set up menu ss wel as acho display hoy) PULSER / RECEIVER Recelver bandwidth 9.5 fe 0 MH by wide bend amoiter, Gain 0.8008, 0.1, 05.1.2, 6, 1238 Selectable: Rejection nee type (0-595), 1% sep, parol ejection (025%) 1% sep. Operating mode Sing probe, souble probe. Test made Fulsereflacion or puse Wancmiasion Eneray HULOW selectabe, Damping NORM sekoctabie Vertical linearity 5% (22.5%) Probe connesior BNC type Echo display Full wave rece. TIME BASE Range ‘Sem min.-SMus. Max (@ 890M sec) Continuous Varisbe, (G.tma atop for 10-1600, ‘iam step for 100enm-SMt.) Delay 0-3 Mire. Continuous Variable -{0.0%evm sta fe 10-100ru- (O.tmm step for 100mm. thre. Aimmtep for T-Sh) PRE ‘Auto set for optimum value. Manually ‘eloctabio fora lowor PRF in therange of SDH2 (0 100} instep of 10H? Velocity 000M /see-S999Msee ‘Time base tinearity 1% (20.5%) Zoom Gates pertion, min, 1mm Triggering leteenet Probe Zero 0-99.99 MONITOR GATE MonitorGates —-2.Gauss Wid 1/10 screen to fll seroon “Height 10 serean to 905, “Gate slat rosasured fom di ‘logic seleciable FLAW SIZING Dac 1G pcinis auto pling curve, (min? points) ‘lara function irked to gate 2 ‘Simultaneous? asaonal curves with ‘seletnd attenuation ie. Between + 68 To-2008, In 168: Step. ‘go cave types a: ‘Expect Paratoic Print Te Point 4 1STD + offet2 curves th (Rel + xx dB) Universal DS Diagram For Normal /R prabes. Ange probes. GENERAL Trigenamettic Functions. eam path, taw capt & prpcon Measurements Graticule Dimension Power Source Battery indicator Operating Temperature Parameter display Acconsoriee Lock Brightness Alarm Charge Indicators disterce display or slate echo win gue 4 ‘Ang slactin 0-99" eb tikows selection Di $60 Echo Het 110% Tolerance Thick (ee Toto) 4. rm wuinesr 80 Marry Ses Wth’K Scans Fanes, Catraion Parenaters,Thgenomadte Valu, Lab 1 Tg) 190 Calera Paranto ats ABODAG Sets PC comme va USB-B ‘Pen ive connect vin USA Recerde ou PAL EEOOWINPC inetcesotware compas with Wircows (ti. Can upload scan saved eto PC and Pencve thos the USE Pet set ony iB dest seest in reguery wie nso, ‘Selcable ey ar tack bacon Beeigrund ey ‘rse-naotiol yee Seainiecatied parry aaa is Bocaprunstisck “raced yloulreen Gite & gue Rta cabs Brotindeqrenlsniiyaon ik $d x 5 (ter ub chided ine 10 smal isn two type fstab grat vi stand and CRT AML) x BBC TSH) 2aKg. “Suit bana pack, on Rechageable baer model BATS22L Darang tna hes wt batary Batecy charger cam ‘sto zaneso eon sing ocr Mota ADSYS eargeria ae -Banecy charger level ca LCO cipiy. Auto ution whee charged. owssc. Harz &Verical Graco, Gain, Uiversal DGS (aw Sz) Beamgat, Faw Degth/ Thicke, Prete Ditiare, Veloce ota Ange, Thckest, Echo Opa. DAC, Probe Zoo. Delay. Range. Rec. Daeg. Ee. Ga Gee ON/OFF, Gate uh, Gate Wich, Gate Haight, ‘arm Mut, Zoom, Foes, ceo Frowza Lock, Contigo Maru, Nessary Sa, Mary Recs, Send Bay target Pestle canbe ocd ‘jab (0-100 1% Sep) Ati val (sate me) Geeen LED chang. ELECTRONIC & ENGINEERING CD. (1). P. Lo BEE ee eevee rn si the best in ndt — cms:nesieascndacons Wet: wwwstentaron ago Oc: ONENNAL BANGALORE ROLEADA HYDERABAD PUNE, PATWA, NAGPUR, MEW DEL NADODARA

You might also like