Intel Server Board S1200BT Service Guide
Intel Server Board S1200BT Service Guide
Service Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products
Wichtige Sicherheitshinweise
                 Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor
                 Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu
                 Intel-Serverplatinen und Servergehäusen auf der Intel® Server Deployment Toolkit CD
                 oder unter http://www.intel.com/support/motherboards/server/sb/cs-010770.htm.
Consignes de sécurité
                 Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce
                 document avant de suivre toute instruction. Consultez Intel Server Boards and Server
                 Chassis Safety Information sur le Intel® Server Deployment Toolkit CD ou bien rendez-
                 vous sur le site http://www.intel.com/support/motherboards/server/sb/cs-010770.htm.
                 System power on/off: The power button DOES NOT turn off the system AC power. To
                 remove power from system, you must unplug the AC power cord from the wall outlet.
                 Make sure the AC power cord is unplugged before you open the chassis, add, or remove
                 any components.
                 Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives,
                 boards, and other parts. We recommend that you perform all procedures in this chapter
                 only at an ESD workstation. If one is not available, provide some ESD protection by
                 wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on
                 your server when handling parts.
                 ESD and handling boards: Always handle boards carefully. They can be extremely
                 sensitive to ESD. Hold boards only by their edges. After removing a board from its
                 protective wrapper or from the server, place the board component side up on a grounded,
                 static free surface. Use a conductive foam pad if available but not the board wrapper. Do
                 not slide board over any surface.
                 Installing or removing jumpers: A jumper is a small plastic encased conductor that slips
                 over two jumper pins. Some jumpers have a small tab on top that you can grip with your
                 fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab,
                 take care when using needle nosed pliers to remove or install a jumper; grip the narrow
                 sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can
                 damage the contacts inside the jumper, causing intermittent problems with the function
                 controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool
                 you use to remove a jumper, or you may bend or break the pins on the board.
                 This manual is written for system technicians who are responsible for troubleshooting,
                 upgrading, and repairing this server board. This document provides a brief overview of
                 the features of the board/chassis, a list of accessories or other components you may need,
                 troubleshooting information, and instructions on how to add and replace components on
                 the Title of document. For the latest version of this manual, see: http://www.intel.com/
                 support/motherboards/server.
Manual Organization
                 Chapter 1 provides a brief overview of the Intel® Server Board S1200BTL,
                 S1200BTLRM and S1200BTS. In this chapter, you will find a list of the server board
                 features, photos of the product, and product diagrams to help you identify components and
                 their locations.
                 Chapter 2 provides instructions on using the utilities shipped with the board or that may be
                 required to update the system. This includes how to navigate through the BIOS Setup
                 screens, perform a BIOS update, and reset the password or CMOS. Information about the
                 specific BIOS settings and screens is available in the Technical Product Specification. See
                 "Additional Information and Software" for a link to the Technical Product Specification.
                 Chapter 3 provides instructions on adding and replacing components. Use this chapter for
                 step-by-step instructions and diagrams for installing or replacing components such as the
                 memory, processor, control panel board, and battery, among other components.
                 Chapter 4 provides troubleshooting information. In this chapter, you will find BIOS error
                 messages and POST code messages. You will also find suggestions for performing
                 troubleshooting activities to identify the source of a problem.
Product Accessories
                 This server board is compatible with Intel® Server Chassis P4304XXSFCN and
                 P4304XXSHCN.
                 You may need or want to purchase one or more of the following accessory items for
                 your server.
       For information about which accessories, memory, processors, and third-party hardware
       were tested and can be used with your board, and for ordering information for Intel
       products, see: http://www.intel.com/support/motherboards/server.
       Unless otherwise indicated in the following table, once on this Web page, type the
       document or software name in the search field at the left side of the screen and select the
       option to search S1200BT.
        For in-depth technical         Intel® Server Board S1200BT Technical Product Specification
        information about this
        product, including BIOS
        settings and chipset
        information
        If you just received this      Intel® Server Board S1200BT Quick Start User's Guide in the
        product and need to            product box
        install it
        Hardware (peripheral           For the Tested Hardware Operating Systems List, you can go to the
        boards, adapter cards,         Intel® Server Configurator Tool:
        and so forth) and
        operating systems that         http://serverconfigurator.intel.com/default.aspx
        were tested with this
        product
                   For firmware and BIOS         Please go to mainpage on for “S1200BT”. It is under the Software
                   updates, or for BIOS          and Drivers section for the most current BIOS, FRU/SDR, BMC,
                   recovery                      drivers and utilites
See also the Intel® Server Deployment Toolkit CD that came with your server board.
                 This chapter briefly describes the main features of the Intel® Server Board S1200BTL,
                 S1200BTLRM and S1200BTS. This chapter provides a photograph of the product, list of
                 the server board features, and diagrams showing the location of important components
                 and connections on the server board.
 Processors             Supports for one Intel® Xeon® E3-              Supports for one Intel® Xeon® E3-1200
                        1200Processors or the 2nd Generation Intel®    Processors or the 2nd Generation Intel®
                        Core™ i3 Processors in FC-LGA 1155 socket      Core™ i3 Processors in FC-LGA 1155
                        package.                                       socket package.
                          • 5 GT/s point-to-point DMI interface to      •  5 GT/s point-to-point DMI interface to
                            PCH                                            PCH
                          • LGA 1155 pin socket                          • LGA 1155 pin socket
                        Supports for Intel® Xeon® E3-1200 V2           Supports for Intel® Xeon® E3-1200 V2
                        processors or the 3rd Generation Intel®        processors or the 3rd Generation Intel®
                        Core™ i3 processors in FC-LGA 1155 socket      Core™ i3 processors in FC-LGA 1155
                        package.                                       socket package.
                          •   5 GT/s point-to-point DMI interface to    •   5 GT/s point-to-point DMI interface to
                              PCH                                           PCH
                          •   LGA 1155 pin socket                       •   LGA 1155 pin socket
 Memory                 Two memory channels with support for 1066/     Two memory channels with support for
                        1333 MHz (with Intel® Xeon® E3-1200            1066/1333 MHz (with Intel® Xeon® E3-
                        Processors or the 2nd Generation Intel®        1200 Processors or the 2nd Generation
                        Core™ i3 Processors) or 1333/1600 MHz          Intel® Core™ i3 Processors) or 1333/
                        (with Intel® Xeon® E3-1200 V2 Processors or    1600 MHz (with Intel® Xeon® E3-1200 V2
                        the 3rd Generation Intel® Core™ i3             Processors or the 3rd Generation Intel®
                        Processors) ECC Unbuffered (UDIMM) DDR3.       Core™ i3 Processors) ECC Unbuffered
                                                                       (UDIMM) DDR3.
                          •   Up to 2 UDIMMs per channel
                          •   32 GB max with x8 ECC UDIMM (2-Gb         •   Up to 2 UDIMMs per channel
                              DRAM)                                     •   32 GB max with x8 ECC UDIMM (2-
                          •   64-bit wide channels                          Gb DRAM)
                          •   DDR3 I/O Voltage of 1.5 V                 •   64-bit wide channels
                                                                        •   DDR3 I/O Voltage of 1.5 V
 Chipset                  •   Support for Intel® C204 Platform         Support for Intel® C202 Platform
                              Controller Hub (PCH) chipset             Controller Hub (PCH) chipset
                          •   ServerEngines* LLC Pilot III BMC
                              controller (Integrated BMC)
    Add-in PCI, PCI   With Intel® Xeon® E3-1200 processors or the     With Intel® Xeon® E3-1200 processors or
    Express* Cards    2nd Generation Intel® Core™ i3 Processors:      the 2nd Generation Intel® Core™ i3
                                                                      Processors:
                       •   Slot1: One 5V PCI 32 bit/33 MHz
                           connector                                   •   Slot4: One 5V PCI 32 bit/33 MHz
                        • Slot3: One PCI Express* Gen2 x8 (x4              connector
                           throughput) connector                        • Slot5: One PCI Express* Gen2 x8 (x4
                        • Slot4: One PCI Express* Gen2 x8 (x4              throughput) connector
                           throughput) connector                        • Slot6: One PCI Express* Gen2 x8 (x8
                        • Slot5: One PCI Express* Gen2 x8 (x4              throughput) connector
                           throughput) connector                        • Slot7: One PCI Express* Gen2 x16
                        • Slot6: One PCI Express* Gen2 x16 (x8             (x8 throughput) connector
                           throughput) connector                      With Intel® Xeon® E3-1200 V2 processors
                      With Intel® Xeon® E3-1200 V2 processors or      or the 3rd Generation Intel® Core™ i3
                      the 3rd Generation Intel® Core™ i3              Processors:
                      Processors:                                      •   Slot4: One 5V PCI 32 bit/33 MHz
                       •   Slot1: One 5V PCI 32 bit/33 MHz                 connector
                           connector                                   •   Slot5: One PCI Express* Gen2 x8 (x4
                       •   Slot3: One PCI Express* Gen2 x8 (x4             throughput) connector
                           throughput) Gen2 connector                  •   Slot6: One PCI Express* Gen3 x8 (x8
                       •   Slot4: One PCI Express* Gen3 x8 (x4             throughput) connector
                           throughput) connector                       •   Slot7: One PCI Express* Gen3 x16
                       •   Slot5: One PCI Express* Gen3 x8 (x4             (x8 throughput) connector
                           throughput) connector
    System Fan        Five 4-pin fan headers supporting four system   Four 4-pin fan headers supporting four
    Support           fans and one processor                          system fans and one processor
    Video             Onboard ServerEngines* LLC Pilot III BMC        Silicon Motion SM712GX04LF02-BA
                      Controller
 On-board Hard          Support for six Serial ATA II hard drives         Support for six Serial ATA II hard drives
 Drive                  through six onboard SATA II connectors with       through six onboard SATA II connectors
                        SW RAID 0, 1, 5, and 10.                          with SW RAID 0, 1, 5, and 10.
                          •   Up to four SAS hard drives through option   Six 3Gb/s SATA ports
                              Intel® SAS Entry RAID Module card
                          •   Two 6Gb/s SATA ports and four 3Gb/s
                              SATA ports
 RAID Support             •   Intel® Embedded Server RAID                  •   Intel® Embedded Server RAID
                              Technology II through onboard SATA               Technology II through onboard SATA
                              connectors provides SATA RAID 0, 1, and          connectors provides SATA RAID 0, 1,
                              10 and optional RAID 5 support provided          and 10 and optional RAID 5 support
                              by the Intel® RAID Activation Key                provided by the Intel® RAID
                              AXXRAKSW5                                        Activation Key AXXRAKSW5
                          •   Intel® Rapid Storage RAID through            •   Intel® Rapid Storage RAID through
                              onboard SATA connectors provides SATA            onboard SATA connectors provides
                              RAID 0, 1, 5, and 10                             SATA RAID 0, 1, 5, and 10
                          •   One optional internal SAS module
                              connector which supports
                              AXXRMS2AF040, AXXRMS2LL040, and
                              AXX4SASMOD
                          •   Optional Intel® Integrated RAID module
                              support on all PCI-e slots which supports
                              RMT3PB080, RMS25PB080,
                              RMS25PB040, RMS25KB080, and
                              RMS25KB040"
                          •   Only supported in S1200BTLRM SKU.
 LAN                    One Gigabit Ethernet device 82574L connect        One Gigabit Ethernet device 82574L
                        to PCI-E x1 interfaces on the PCH                 connect to PCI-E x 1 interfaces on
                                                                          the PCH
                        One Gigabit Ethernet PHY 82579 connected
                        to PCH through PCI-E x 1 interface                One Gigabit Ethernet PHY 82579
                                                                          connected to PCH through PCI-E x 1
                                                                          interface
A B C D E FG H I J
                                                                                        L
       AA                                                                               M
                                                                                        N
BB
       CC                                                                               O
       DD
EE P
FF
       GG
                                                                                        Q
HH
Z YX W V U T S R
AF003509
                        D.   Slot 5, PCI Express* Gen2 x4 (x8     U.   USB connector for smart module
                             connector)
G. SATA_KEY X. SYS_FAN_1
M. TPM connector
     J1H3: Protected RTC     1-2     These pins should have a jumper in place for normal system
     (CMOS clear)                    operation. (Default)
                             2-3     If these pins are jumpered with AC power plugged, the CMOS
                                     settings are cleared within five seconds. These pins should not be
                                     jumpered for normal operation.
J1J2: ME Force Update 1-2 ME Firmware Force Update Mode – Disabled (Default)
    J1G1: Password Clear           1-2      These pins should have a jumper in place for normal system
                                            operation. (Default)
                                   2-3      If these pins are jumpered, administrator and user passwords are
                                            cleared within 5-10 seconds after the system is powered on. These
                                            pins should not be jumpered for normal operation.
    J2G1: BIOS Recovery            1-2      These pins should have a jumper in place for normal system
                                            operation. (Default)
                                   2-3      Given that the main system BIOS will not boot with these pins
                                            jumpered, system can only boot from EFI-bootable recovery media
                                            with the recovery BIOS image.
J4A2: BMC Force Update 1-2 BMC Firmware Force Update Mode - Disabled (Default)
    J1F1: Password Clear           1-2      These pins should have a jumper in place for normal system
                                            operation. (Default)
                                   2-3      If these pins are jumpered, administrator and user passwords will be
                                            cleared on the next reset.
                                            Note: These pins should not be jumpered for normal operation.
     J1E2: Protected RTC           1-2     These pins should have a jumper in place for normal system
     (CMOS clear)                          operation. (Default)
                                   2-3     If these pins are jumpered, the CMOS settings are cleared on the
                                           next reset.
                                           Note: These pins should not be jumpered for normal operation.
     J1F3: BIOS Recovery           1-2     These pins should have a jumper in place for normal system
                                           operation.(Default)
                                   2-3     The main system BIOS will not boot with these pins jumpered.
                                           Note: The system will boot from EFI-bootable recovery media with a
                                           recovery BIOS image.
     J1F2: ME Force                1-2     These pins should have a jumper in place for normal system
     Recovery                              operation. (Default)
Off Idle
RAID Support
                 The Intel® Server Board S1200BTL, S1200BTLRM and S1200BTS provide two
                 embedded SATA controllers:
                    • Intel® Embedded Server RAID Technology II
                    • Intel® Rapid Storage RAID technology
                 The Intel® Embedded Server RAID Technology II provides RAID modes 0,1, 10, and 5
                 (with SW RAID key). The Intel® Rapid Storage RAID technology provides RAID modes
                 0, 1, 10, and 5.
                 The Intel® Server Board S1200BTL/S1200BTLRM provide two 6Gb/s SATA ports and
                 four 3Gb/s SATA ports.
The Intel® Server Board S1200BTS provides six 3Gb/s SATA ports.
                 For information on how to configure RAID, refer to the RAID Software User’s Guide at:
                 http://www.intel.com/support/motherboards/server.
Hardware Requirements
                 To avoid integration difficulties and possible board damage, your system must meet the
                 following requirements outlined. For a list of qualified components, see the links under
                 “Additional Information and Software”.
Processor
                 The Intel® Server Board S1200BT supports the Intel® Xeon® E3-1200 Processors or the
                 2nd Generation Intel® Core™ i3 Processors in FC-LGA 1155 socket package with 5GT/s
                 point-to-point DMI interface to PCH and LGA 1155 pin socket.
Memory
                The Intel® Server Board S1200BT supports a DDR3-based ECC UDIMM memory
                subsystem and up to two DIMM sockets per channel.
                See the following figure for channel slot configuration. The minimal memory population
                is one DIMM in memory slot DIMM_A1. For a complete list of supported memory, see
                the links under “Additional Information and Software”
     4 DIMMs Dual     A1 Dual Channel      A2 Dual Channel     B1 Dual Channel       B2 Dual Channel
     Channel          Symmetric            Symmetric           Symmetric             Symmetric
     Symmetric
                The Independent Channel Mode is the default Maximum Performance Mode preferred for
                Intel® Xeon® Processor E3-1200 Series based platforms. All two channels may be
                populated in any order and have no matching requirements. All channels must run at the
                same interface frequency, but individual channels may run at different DIMM timings
                (RAS latency, CAS latency, and so on).
Optional Hardware
Intel® ROC Module
                 The Intel® Server Board S1200BTLRM provides the support of an optional Intel RAID
                 Module. Five modules are supported in this platform: RMT3PB080, RMS25PB080,
                 RMS25PB040, RMS25KB080 and RMS25KB040.
                 The optional Intel® Integrated RAID Module RMT3PB080 is an intelligent custom board-
                 to-board PCI Express* 2.0 compliant interface RAID adapter with an integrated LSI*
                 SAS2208 ROC, providing both a SATA controller and RAID on Chip. With eight internal
                 ports supporting 6Gb/s SATA data transfers, and provides RAID 0,1,10,5,6,50,60. RAID
                 Premium Feature Key is supported.
         The optional Intel® SAS Entry RAID Module AXX4SASMOD provides four SAS
         connectors that support up to four hard drives with a non-expander backplane or up to
         eight hard drives with an expander backplane.4 ports full featured SAS/SATA hardware
         RAID through optional Intel® Integrated RAID Module SROMBSASMR
         (AXXROMBSASMR), provides RAID 0, 1, 5, 6 and striping capability for spans
         10, 50, 60.
                 When Intel® Embedded Server RAID Technology II is enabled with the SAS Module
                 AXX4SASMOD, enclosure management is provided through the SAS_SGPIO or SES
                 connector on the SAS Module AXX4SASMOD when a cable is attached between this
                 connector and the backplane or I2C interface.
        Note: For help with navigating the BIOS Setup utility, refer to the Intel® Server Board S1200BT
              Technical Product Specification.
Starting Setup
                 To enter the BIOS Setup using a keyboard (or emulated keyboard); press the <F2>
                 function key during boot time when the OEM or Intel® logo is displayed. The following
                 message is displayed on the diagnostics screen and under the Quiet Boot logo screen:
                 When the Setup Utility is entered, the Main screen is displayed. However, serious errors
                 cause the system to display the Error Manager screen instead of the Main screen.
                 Each Setup menu page contains a number of features. Each feature is associated with a
                 value field, except those used for informative purposes. Each value field contains
                 configurable parameters. Depending on the security option chosen and in effect by the
                 password, a menu feature’s value may or may not be changed. If a value cannot be
                 changed, its field is made inaccessible and appears grayed out.
 <Enter>                 Execute Command                The <Enter> key is used to activate submenus when the
                                                        selected feature is a submenu, or to display a pick list if a
                                                        selected option has a value field, or to select a subfield for
                                                        multi-valued features like time and date. If a pick list is
                                                        displayed, the <Enter> key selects the currently
                                                        highlighted item, undoes the pick list, and returns the
                                                        focus to the parent menu.
 <Esc>         Exit                The <Esc> key provides a mechanism for backing out of
                                   any field. When the <Esc> key is pressed while editing any
                                   field or selecting features of a menu, the parent menu is
                                   re-entered.
                                   When the <Esc> key is pressed in any submenu, the
                                   parent menu is re-entered. When the <Esc> key is
                                   pressed in any major menu, the exit confirmation window
                                   is displayed and the user is asked whether changes can
                                   be discarded. If "No" is selected and the <Enter> key is
                                   pressed, or if the <Esc> key is pressed, the user is
                                   returned to where they were before <Esc> was pressed,
                                   without affecting any existing settings. If "Yes" is selected
                                   and the <Enter> key is pressed, the setup is exited and
                                   the BIOS returns to the main System Options Menu
                                   screen.
 K             Select Item         The up arrow is used to select the previous value in a pick
                                   list, or the previous option in a menu item's option list. The
                                   selected item must then be activated by pressing the
                                   <Enter> key.
 K             Select Item         The down arrow is used to select the next value in a menu
                                   item's option list, or a value field's pick list. The selected
                                   item must then be activated by pressing the <Enter> key.
 <–>           Select Menu         The left and right arrow keys are used to move between
                                   the major menu pages. The keys have no effect if a sub-
                                   menu or pick list is displayed.
 <Tab>         Select Field        The <Tab> key is used to move between fields. For
                                   example, <Tab> can be used to move from hours to
                                   minutes in the time item in the main menu.
 _             Change Value        The minus key on the keypad is used to change the value
                                   of the current item to the previous value. This key scrolls
                                   through the values in the associated pick list without
                                   displaying the full list.
 +             Change Value        The plus key on the keypad is used to change the value of
                                   the current menu item to the next value. This key scrolls
                                   through the values in the associated pick list without
                                   displaying the full list. On 106-key Japanese keyboards,
                                   the plus key has a different scan code than the plus key on
                                   the other keyboards, but will have the same effect.
 <F9>          Setup Defaults      Pressing the <F9> key causes the following to display:
                                                    Load Optimized Defaults?
                                                             Yes    No
                                   If "Yes" is highlighted and <Enter> is pressed, all Setup
                                   fields are set to their default values. If "No" is highlighted
                                   and <Enter> is pressed, or if the <Esc> key is pressed, the
                                   user is returned to where they were before <F9> was
                                   pressed without affecting any existing field values.
 <F10>                   Save and Exit                Pressing the <F10> key causes the following message to
                                                      display:
                                                                    Save configuration and reset?
                                                                              Yes     No
                                                      If "Yes" is highlighted and <Enter> is pressed, all changes
                                                      are saved and the Setup is exited. If "No" is highlighted
                                                      and <Enter> is pressed, or the <Esc> key is pressed, the
                                                      user is returned to where they were before <F10> was
                                                      pressed without affecting any existing values.
                 For each of these screens, there is an image of the screen with a list of Field Descriptions
                 which describe the contents of each item on the screen. Each item on the screen is
                 hyperlinked to the relevant Field Description. Each Field Description is hyperlinked back
                 to the screen image.
               There are more categories than will fit across the top of the screen, so at any given time
               there will be some categories which will not appear until the user has scrolled across the
               tabs which are present.
               The categories and the screens included in each category are listed below, with links to
               each of the screens named.
ª Processor Configuration
ª Memory Configuration
ª USB Configuration
ª PCI Configuration
ª Console Redirection
ª System Information
ª CDROM Order
ª Floppy Order
              Comments:Information only. Displays the Platform ID for the board on which the BIOS is
              executing POST.
                3. BIOS Version
                 Comments:Information only. The version information displayed is taken from the BIOS
                 ID String, with the timestamp segment dropped off. The segments displayed are:
                          Platform:Identifies whether this is a Bromolow or Romley platform BIOS
                          86B:Identifies this BIOS as being an EPSD Intel® Server BIOS
                          xx: Major Revision level of the BIOS
                          yy: Release Revision level for this BIOS
                          zzzz: Release Number for this BIOS
                    4. Build Date
Option Values: <Date and time when the currently installed BIOS was created (built)>
                 Comments:Information only. The time and date displayed are taken from the timestamp
                 segment of the BIOS ID String.
                    5. Total Memory
                 Comments:Information only. Displays the total physical memory installed in the system,
                 in MB or GB. The term physical memory indicates the total memory discovered in the
                 form of installed DDR3 DIMMs.
                    6. Quiet Boot
Disabled
Help Text:
Disabled
Help Text:
[Disabled] – Attempt to boot and do not go to the Error Manager for critical POST errors.
          Option Values: <System Date initially displays the current system calendar date, including
          the day of the week>
Help Text:
System Date has configurable fields for the current Month, Day, and Year.
          Comments:This field will initially display the current system day of week and date. It may
          be edited to change the system date.
            9. System Time
          Option Values: <System Time initially displays the current system time of day, in 24-hour
          format>
Help Text:
System Time has configurable fields for Hours, Minutes, and Seconds.
          Comments: This field will initially display the current system time (24 hour time). It may
          be edited to change the system time.
          To access this screen from the Main screen or other top-level Tab screen, press the right
          or left arrow keys to traverse the tabs at the top of the Setup screen until the Advanced
          screen is selected.
                 Comments:Selection only. Position to this line and press the <Enter> key to go to the
                 Processor Configuration group of configuration settings.
                    2. Memory Configuration
Help Text:
                 Comments:Selection only. Position to this line and press the <Enter> key to go to the
                 Memory Configuration group of configuration settings.
                    3. Mass Storage Controller Configuration
Help Text:
                 Comments:Selection only. Position to this line and press the <Enter> key to go to the
                 Mass Storage Controller Configuration group of configuration settings.
                    4. Serial Port Configuration
     Comments:Selection only. Position to this line and press the <Enter> key to go to the
     Serial Port Configuration group of configuration settings.
       5. USB Configuration
Help Text:
     Comments:Selection only. Position to this line and press the <Enter> key to go to the USB
     Configuration group of configuration settings.
       6. PCI Configuration
Help Text:
     Comments:Selection only. Position to this line and press the <Enter> key to go to the PCI
     Configuration group of configuration settings.
       7. System Acoustic and Performance Configuration
Help Text:
     Comments:Selection only. Position to this line and press the <Enter> key to go to the
     System Acoustic and Performance Configuration group of configuration settings.
       8. Hardware Monitor
Help Text:
     The Hardware Monitor screen allows the user to configure Fan Speed Control and to view
     displays of temperature and voltage status.
     This screen is present only for boards without a BMC. There are two screen layouts,
     depending on whether Auto or Manual Fan Control is selected on the screen. “Auto” Fan
     Control is intended to support standard EPSD chassis options. “Manual” Fan Control is
     intended to support third-party chassis installations.
     To access this screen from the Main screen, select Server Management > Hardware
     Monitor. To move to another screen, press the <Esc> key to return to the Server
     Management screen, then select the desired screen.
                 To access this screen from the Main screen, select Advanced > Processor Configuration.
                 To move to another screen, press the <Esc> key to return to the Advanced screen, then
                 select the desired screen.
Help Text:<None>
     Comments:Information only. Displays the Processor Signature value (from the CPUID
     instruction) identifying the type of processor and the stepping Processor Frequency
Help Text:<None>
Help Text:<None>
Help Text:<None>
Help Text:<None>
Help Text:<None>
Help Text:<None>
                 Comments:Information only. Displays Brand ID string read from processor with CPUID
                 instruction.
                    7. CPU Core Ratio Settings
Help Text:
                 This value must between Max Efficiency Ratio (LFM) and Maximum non-turbo ratio set
                 by Hardware (HFM).
                 Comments: This option is only visible if Show CPU Core Ratio is Enabled.
                    8. Show CPU Core Ratio
Disabled
Help Text:
                 Comments: If this option is enabled, the CPU core ratio will be limited to the value in the
                 CPU Core Ratio Settings.
                    9. Intel® Turbo Boost Technology
Disabled
Help Text:
                 Intel® Turbo Boost Technology allows the processor to automatically increase its
                 frequency if it is running below power, temperature, and current specifications.
                 Comments:This option is only visible if all processors installed in the system support
                 Intel® Turbo Boost Technology. In order for this option to be available, Enhanced Intel®
                 SpeedStep® Technology must be Enabled.
                    10. Enhanced Intel® SpeedStep® Tech
Disabled
Help Text:
     Comments:When Disabled, the processor setting reverts to running at Max TDP Core
     Frequency (rated frequency).
     This option is only visible if all processors installed in the system support Enhanced
     Intel® SpeedStep® Technology. In order for the Intel® Turbo Boost option to be available,
     Enhanced Intel® SpeedStep® Technology must be Enabled.
       11. Turbo Boost Performance/Watt Mode
Traditional
Help Text:
     When Power Optimized is selected, Intel® Turbo Boost Technology engages after
     performance state P0 is sustained for more than two seconds. When Traditional is
     selected, Intel® Turbo Boost Technology is engaged even for P0 requests less than
     two seconds.
Disabled
Help Text:
Disabled
Help Text:
Disabled
Help Text:
                 Comments:This option is only visible if all processors installed in the system support
                 Intel® Hyper-Threading Technology.
                    15. Core Multi-Processing
Help Text:
                 Comments:The number of cores that appear as selections and in the Help text depends on
                 the number of cores in the processors installed.
                    16. Execute Disable Bit
Disabled
Help Text:
Execute Disable Bit can help prevent certain classes of malicious buffer overflow attacks.
                 Comments:This option is only visible if all processors installed in the system support the
                 Execute Disable Bit. The OS and applications installed must support this feature in order
                 for it to be enabled.
                    17. Intel® Virtualization Technology
Disabled
            Intel® Virtualization Technology allows a platform to run multiple operating systems and
            applications in independent partitions.
     Note: A change to this option requires the system to be powered off and then back on before the
           setting takes effect.
            Comments:This option is only visible if all processors installed in the system support
            Intel® VT. The software configuration installed on the system must support this feature in
            order for it to be enabled.
              18. Intel® VT for Directed I/O
Option Values:Enabled
Disabled
Help Text:
Report the I/O device assignment to VMM through DMAR ACPI Tables.
            Comments:This option is only visible if all processors installed in the system support
            Intel® VT-d. The software configuration installed on the system must support this feature
            in order for it to be enabled.
              19. Interrupt Remapping
Disabled
Help Text:
            Comments:This option only appears when Intel® Virtualization Technology for Directed
            I/O is Enabled.
              20. ATS Support
Option Values:Enabled
Disabled
Help Text:
            Comments:This option only appears when Intel® Virtualization Technology for Directed
            I/O is Enabled. Appears only on Romley boards.
              21. Pass-through DMA Support
Disabled
Help Text:
                 Comments:This option only appears when Intel® Virtualization Technology for Directed
                 I/O is Enabled.
                    22. MLC Streamer
Disabled
Help Text:
                 Comments:MLC Streamer is normally Enabled for the best efficiency in L2 Cache and
                 Memory Channel use, but disabling it may improve performance for some processing
                 loads and on certain benchmarks. For more information.
                    23. MLC Spatial Prefetcher
Disabled
Help Text:
                 [Enabled] – Fetches adjacent cache line (128 bytes) when required data is not currently in
                 cache.
[Disabled] - Only fetches cache line with data required by the processor (64 bytes).
Disabled
Help Text:
[Disabled] – Only fetches cache line with data required by the processor (64 bytes).
         Comments: DCU Data Prefetcher is normally Enabled, for best efficiency in L1 Data
         Cache and Memory Channel use, but disabling it may improve performance for some
         processing loads and on certain benchmarks. For more information.
           25. DCU Instruction Prefetcher
Disabled
Help Text:
         The next cache line will be prefetched into L1 instruction cache from L2 or system
         memory during unused cycles if it sees that the processor core has accessed several bytes
         sequentially in a cache line as data. [Disabled] – Only fetches cache line with data
         required by the processor (64 bytes).
Disabled
Help Text:
         When enabled, a SMX can utilize the additional hardware capabilities provided by Safer
         Mode Extensions.
         Comments:Intel (SMX) Safer Mode Extensions is set of CPU instructions used by Intel
         TXT software.
Memory Configuration
         The Memory Configuration screen allows the user to view details about the DDR3
         DIMMs that are installed as system memory.
Help Text:<None>
Help Text:<None>
                 The Effective Memory is the difference between Total Physical Memory and the sum of
                 all memory reserved for internal usage, RAS redundancy and SMRAM. This difference
                 includes the sum of all DDR3 DIMMs that failed Memory BIST during POST or were
                 disabled by the BIOS during the memory discovery phase in order to optimize
                 memory configuration.
Note: Some server operating systems do not display the total physical memory installed.
Intel® Flex
Help Text:<None>
Help Text:<None>
     For Intel® Xeon Processor E3-1200 Processors – supports memory speeds are 1066 MT/s
     and 1333 MT/s.
     For Intel® Xeon Processor E3-1200 V2 Processors – supports memory speeds are 1333
     MT/s and 1600 MT/s.
       5. DIMM_A1
       6. DIMM_A2
       7. DIMM_B1
       8. DIMM_B2
Not Installed
Failed
Disabled
                 To access this screen from the Main screen, select Advanced > Mass Storage Controller
                 Configuration. To move to another screen, press the <Esc> key to return to the Advanced
                 screen, then select the desired screen.
Option Values:Enabled
Disabled
                 Help Text:AHCI capable SATA controller (also known as Onboard SATA Controller)
                 refers to the Advanced Host Controller Interface SATA device integrated into the chipset.
                 In order to utilize the AHCI capabilities, the AHCI option needs to be enabled in the
                 SATA Mode menu.
                 Comments:If the SATA Controller is Enabled, then the mode of operation can be set using
                 following options. If it is Disabled, the SATA Ports will not operate. and any installed
                 SATA devices will be unavailable.
Option Values:Compatibility
Enhanced
AHCI
RAID Mode
Help Text:
            [Compatibility] provides PATA emulation on the SATA device, allowing the use of legacy
            IDE/PATA drivers.
            [Enhanced] provides Native SATA support, using native SATA drivers included with the
            vast majority of current operating systems.
            [AHCI] enables the Advanced Host Controller Interface, which provides Enhanced SATA
            functionality plus additional functionality such as Native Command Queuing. Uses AHCI
            drivers available for the majority of current operating systems.
[RAID Mode] provides host based RAID support on the onboard SATA ports.
            Comments:This option setting only appears when the SATA Controller is Enabled. In
            order to use the AHCI setting, any OS being booted must have AHCI drivers available. If
            the RAID Mode setting is chosen, then the following setting for RAID Mode Options will
            appear.
     Note: When the SATA Mode setting is changed, before attempting to set the Boot Order it is
           necessary to do a Save and Exit, and reboot to properly recognize any SATA hard drives.
              3. RAID Mode Options
            Help Text:
                 — Intel® ESRT2 (Powered By LSI(TM)): Supports RAID 0/1/10 and optional
                   RAID 5 with Intel® Embedded Server RAID Technology 2 (ESRT2). Uses
                   Intel® ESRT2 drivers (based on LSI(TM) MegaSR).
                 — Intel® RST (formerly known as Matrix RAID): Provides pass-through drive
                   support with Intel® Rapid Storage Technology (RST). Also provides host based
                   RAID 0/1/10/5 support. Uses Intel® RST iaStor drivers
            Comments:This option setting only appears when the SATA Controller is enabled, and
            RAID Mode has been selected as the operational SATA Mode. If a RAID Volume has not
            previously been created, it will be necessary to Save and Exit and reboot in order to create
            a RAID Volume.
              4. Intel® Storage Module
Help Text:Shows the name of the Storage Module detected, if one is installed.
                 When an AXX4SASMOD Storage Module is detected, then (and only then) a following
                 option will be available for switching between IT/IR and ESRT2 RAID settings.
                    5. Configure AXX4SASMOD RAID Module
Option Values:IT/IR
                 Help Text:
                       — IT/IR: Provides pass-through drive support as well as HW RAID 0/1/1e support.
                         Uses LSI(TM) mpt drivers.
                       — Intel® ESRT2 (Powered by LSI(TM)): Supports RAID 0/1/10 and optional
                         RAID 5 with Intel® Embedded Server RAID Technology 2 (ESRT2). Uses
                         Intel® ESRT2 drivers (based on LSI(TM) MegaSR).
<Drive Information>
Help Text:
                 Comments:Information only. This is repeated for all 6 SATA Port for the Onboard SATA
                 Controller. This section for SATA Drive Information does not appear when the SATA
                 Mode is RAID Mode.
USB Configuration
          The USB Configuration screen allows the user to configure the USB controller options.
          To access this screen from the Main screen, select Advanced > USB Configuration. To
          move to another screen, press the <Esc> key to return to the Advanced screen, then select
          the desired screen.
                 To access this screen from the Main screen, select Advanced > PCI Configuration. To
                 move to another screen, press the <Esc> key to return to the Advanced screen, then select
                 the desired screen.
Disabled
Help Text:
Enables or disables PCI PME function for Wake on LAN capability from LAN adapters.
          To access this screen from the Main screen, select Advanced > System Acoustic and
          Performance Configuration. To move to another screen, press the <Esc> key to return to
          the Advanced screen, then select the desired screen.
Help Text:
          Closed Loop Throttling Mode is supported only when ECC DIMM plugged. Open Loop
          Throttling Mode is not supported.
          Comments:Information only, for S1200BT boards with BMC:. CLTT Mode is the only
          mode supported. This will always be Auto, since there is no choice. If CLTT Mode cannot
          be established, then the fallback mode is no memory thermal-based throttling.
            2. Altitude
301m-900m
Help Text:
                 Comments:This option sets an altitude value in order to choose a Fan Profile that is
                 optimized for the air density at the current altitude at which the system is installed.
                    3. Set Fan Profile
Help Text:
                 [Acoustic] - The system will favor using throttling of memory over boosting fans to cool
                 the system if thermal thresholds are met.
                 Comments:Information only, for S1200BT boards with BMC: Acoustic Mode is the only
                 Fan Profile supported. This will always be Acoustic, since there is no other choice.
          To access this screen from the Main screen or other top-level Tab screen, press the right
          or left arrow keys to traverse the tabs at the top of the Setup screen until the Security
          screen is selected.
Option Values:Installed
Not Installed
Help Text:<None>
Option Values:Installed
Not Installed
Help Text:<None>
Administrator password is used to control change access in the BIOS Setup utility.
                 Only alphanumeric characters can be used. Maximum length is seven characters and it is
                 case sensitive.
Note: Administrator password must be set in order to use the user account.
                 Comments: This option is only to control access to Setup. Administrator has full access to
                 all Setup options. Clearing the Administrator Password also clears the User Password.
                    4. Set User Password
Help Text:
User password is used to control entry access to the BIOS Setup utility.
                 Only alphanumeric characters can be used. Maximum length is seven characters and it is
                 case sensitive.
Note: Removing the administrator password also automatically removes the user password.
                 Comments: Available only if the Administrator Password is installed. This option protects
                 Setup settings as well as boot choices. The User Password only allows limited access to
                 the Setup options, and no choice of boot devices.
                    5. Power ON Password
Disabled
Help Text:
                 Comments: This option is available for operation only when setting Administrator
                 Password.
                    6. Front Panel Lockout
Option Values:Enabled
Disabled
Help Text:
                 If enabled, locks the power button and reset button on the system's front panel. If
                 [Enabled] is selected, power and reset must be controlled through a system management
                 interface.
May be:
Help Text:<None>
            A Disabled TPM device does not execute commands that use the TPM functions and
            TPM security operations are not available.
            An Enabled & Deactivated TPM is in the same state as a disabled TPM, except that
            setting of the TPM ownership is allowed if it is not present already.
            An Enabled & Activated TPM executes all commands that use the TPM functions and
            TPM security operations are also available.
Turn On
Turn Off
Clear Ownership
Help Text:
            [Clear Ownership] - Removes the TPM ownership authentication and returns the TPM to
            factory default state.
Note: BIOS setting will return to [No Operation] on every boot cycle by default.
         To access this screen from the Main screen or other top-level Tab screen, press the right
         or left arrow keys to traverse the tabs at the top of the Setup screen until the Server
         Management screen is selected.
Option Values:Enabled
Disabled
Help Text:
         Enable/disable Ecodesign EuP LOT6 “Deep Sleep” Off-Mode for near-zero energy use
         when powered off.
         Comments:This option controls whether the system goes into “Deep Sleep” or more
         conventional S5 “Soft-Off” when powered off. S5 can wake up faster and can Wake on
         LAN, but Deep Sleep uses less energy.
         This option will not appear on platforms which do not support EuP LOT6 Off-Mode. For
         details on any platform.
Console Redirection
                 The Console Redirection screen allows the user to enable or disable console redirection
                 and to configure the connection options for this feature.
                 To access this screen from the Main screen, select Server Management > Console
                 Redirection. To move to another screen, press the <Esc> key to return to the Server
                 Management screen, then select the desired screen.
          This screen may have fewer or more items displayed on it, depending on the system
          hardware configuration. For example, when the board does not include a BMC, this
          display does not include BMC Firmware Revision or SDR Version. Similarly, there is no
          HSC Firmware Revision displayed for systems which do not include an HSC.
          To access this screen from the Main screen, select Server Management > System
          Information. To move to another screen, press the <Esc> key to return to the Server
          Management screen, then select the desired screen.
         To access this screen from the Main screen, select Server Management > System
         Information. To move to another screen, press the <Esc> key to return to the Server
         Management screen, then select the desired screen.
         The BMC LAN Configuration screen is unusual in that the LAN Configuration
         parameters are maintained by the BMC itself, so this screen is just a User Interface to the
         BMC configuration. As such, the initial values of the LAN options shown on the screen
         are acquired from the BMC when this screen is initially accessed by a user. Any values
         changed by the user are communicated back to the BMC when a “Save Changes” or “Save
         Changes and Exit” action is performed. If a “Discard Changes” or “Discard Changes and
         Exit” action is performed instead, any accumulated changes from this screen will be
         disregarded and lost.
                 To access this screen from the Main screen, select Server Management > Hardware
                 Monitor. To move to another screen, press the <Esc> key to return to the Server
                 Management screen, then select the desired screen.
          To access this screen from the Main screen, select Server Management > Hardware
          Monitor > Realtime Temperature and Voltage Status. To move to another screen, press
          the <Esc> key to return to the Hardware Monitor screen, if necessary press the <Esc>
          key again to return to the Server Management screen, then select the desired screen.
          If all types of bootable devices are installed in the system, then the default boot order is as
          follows:
CD/DVD-ROM
                 To access this screen from the Main screen or other top-level Tab screen, press the right
                 or left arrow keys to traverse the tabs at the top of the Setup screen until the Boot Options
                 screen is selected.
        Note: A USB Hard Disk drive or a USB Key device formatted as a hard disk will appear in
              this section.
                 To access this screen from the Main screen, select Boot Options > Hard Disk Order. To
                 move to another screen, press the <Esc> key to return to the Boot Options screen, then
                 select the desired screen.
CDROM Order
            The CDROM Order screen allows the user to control the order in which BIOS attempts to
            boot from the CDROM drives installed in the system. This screen is only available when
            there is at least one CDROM device available in the system configuration.
            To access this screen from the Main screen, select Boot Options > CDROM Order. To
            move to another screen, press the <Esc> key to return to the Boot Options screen, then
            select the desired screen.
Floppy Order
            The Floppy Order screen allows the user to control the order in which BIOS attempts to
            boot from the Floppy Disk drives installed in the system. This screen is only available
            when there is at least one Floppy Disk (diskette) device available in the system
            configuration.
     Note: A USB Floppy drive or a USB Key device formatted as a diskette drive will appear in this
           section.
            To access this screen from the Main screen, select Boot Options > Floppy Order. To
            move to another screen, press the <Esc> key to return to the Boot Options screen, then
            select the desired screen.
                 To access this screen from the Main screen, select Boot Options > Network Device
                 Order. To move to another screen, press the <Esc> key to return to the Boot Options
                 screen, then select the desired screen.
                 To access this screen from the Main screen, select Boot Options > BEV Device Order.
                 To move to another screen, press the <Esc> key to return to the Boot Options screen, then
                 select the desired screen.
          To access this screen from the Main screen, select Boot Options > Add EFI Boot
          Option. To move to another screen, press the <Esc> key to return to the Boot Options
          screen, then select the desired screen.
          To access this screen from the Main screen, select Boot Options > Delete EFI Boot
          Option. To move to another screen, press the <Esc> key to return to the Boot Options
          screen, then select the desired screen.
        Note: This list is not in order according to the system Boot Option order. The “Internal EFI
              Shell” will always be available, regardless of whether any other bootable devices
              are available.
                 To access this screen from the Main screen or other top-level Tab screen, press the right or
                 left arrow keys to traverse the tabs at the top of the Setup screen until the Boot Manager
                 screen is selected.
This screen is the same for both Bromolow and Romley boards.
                 To access this screen from the Main screen or other top-level Tab screen, press the right or
                 left arrow keys to traverse the tabs at the top of the Setup screen until the Error Manager
                 screen is selected.
            The System Event Log viewer can display as many log records as are stored in a single
            page. Each Event Record is displayed on one line. The most recent Event Record is
            displayed on the top. When there are more Event Records that can be displayed at once,
            the <PageUp> and <PageDown> keys can be used. There is also a scroll bar to allow
            users to view the logs from beginning to the end.
     Note: When the System Event Log is full, or when the user wishes to remove the current Event
           Records, the user can choose Clear System Event Log in Setup.
                 To access this screen from the Main screen or other top-level Tab screen, press the right
                 or left arrow keys to traverse the tabs at the top of the Setup screen until the Exit screen is
                 selected.
       Note: Do not skip step 2. You need these settings to configure your computer at the end of
             the procedure.
       Note: Before attempting a BIOS upgrade, review the instructions and release notes provided in
             the readme file distributed with the BIOS image file. The release notes contain critical
             information regarding jumper settings, specific fixes, or other information to complete
             the upgrade.
     Caution: Do not power down the system during the BIOS update process! The system resets
              automatically when the BIOS update process is completed.
       Note: You may encounter a CMOS Checksum error or other problem after reboot. If this
             happens, shut down the system and reboot. CMOS checksum errors require that you enter
             Setup, check your settings, save your settings, and exit Setup.
              To place the baseboard into recovery mode, move the boot option jumper (located on the
              baseboard) to the recovery position. The BIOS can then execute the recovery BIOS (also
              known as the boot block) instead of the normal BIOS. The recovery BIOS is a self-
              contained image that exists solely as a fail-safe mechanism for installing a new
              BIOS image.
                             BMC
                             Force          Default
                            Update   2
                                            Enabled
                            J1A2     3
AF003291
       When performing the standard Integrated BMC firmware update procedure, the update
       utility places the Integrated BMC into an update mode, allowing the firmware to load
       safely onto the flash device. In the unlikely event the Integrated BMC firmware update
       process fails (due to the Integrated BMC not being in the proper update state), the server
        Note: Normal Integrated BMC functionality is disabled with the Force Integrated BMC Update
              jumper set to the enabled position. The server should never be run with the Integrated
              BMC Force Update jumper set in this position. This jumper setting should only be used
              when the standard firmware update process fails. This jumper should remain in the
              default/disabled position when the server is running normally.
                    1. Power down and remove the AC power cord.
                    2. Open the server chassis. For instructions, refer to your server chassis
                       documentation.
                    3. Move the jumper from the default operating position (covering pins 1 and 2) to the
                       enabled position (covering pins 2 and 3).
                    4. Close the server chassis.
                    5. Reconnect the AC cord and power up the server.
                    6. Perform the Integrated BMC firmware update procedure as documented in the
                       README.TXT file included in the given Integrated BMC firmware update
                       package. After successful completion of the firmware update process, the firmware
                       update utility may generate an error stating the Integrated BMC is still in
                       update mode.
                    7. Power down and remove the AC power cord.
                    8. Open the server chassis.
                    9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled
                       position (covering pins 1 and 2).
                    10. Close the server chassis.
                    11. Reconnect the AC cord and power up the server.
Installing DIMMs
                 To install DIMMs, follow these steps:
                    1. Observe the safety and ESD precautions in “Safety Information”.
                    2. Turn off all peripheral devices connected to the server. Turn off the server.
                    3. Disconnect the AC power cord from the server.
                    4. Remove the server's cover and locate the DIMM sockets (see letters “A” to “E”
                       Figure 44).
         5. Make sure the clips at either end of the DIMM socket(s) are pushed outward to the
            open position (see letter “A” in Figure 44).
         6. Holding the DIMM by the edges, remove it from its anti-static package.
         7. Position the DIMM above the socket. Align the two small notches in the bottom
            edge of the DIMM with the keys in the socket (letter “B” in Figure 44).
         8. Insert the bottom edge of the DIMM into the socket (letter “C” in Figure 44).
         9. When the DIMM is inserted, push down on the top edge of the DIMM until the
            retaining clips snap into place ((letter “D” in Figure 44). Make sure the clips are
            firmly in place (letter “E” in Figure 44).
         10. Replace the server's cover and reconnect the AC power cord. Refer to the
             documentation that came with your server chassis for instructions on installing the
             server’s cover.
Removing DIMMs
       To remove a DIMM, follow these steps:
         1. Observe the safety and ESD precautions in “Safety Information”.
         2. Turn off all peripheral devices connected to the server. Turn off the server.
         3. Remove the AC power cord from the server.
         4. Remove the server's cover. See the documentation that came with your server
            chassis for instructions on removing the server's cover.
         5. Gently spread the retaining clips at each end of the socket. The DIMM will lift from
            the socket.
         6. Holding the DIMM by the edges, lift it from the socket, and store it in an
            anti-static package.
         7. Reinstall and reconnect any parts you removed or disconnected to reach the
            DIMM sockets.
    Caution: Processor must be appropriate: You may damage the server board if you install a
             processor that is inappropriate for your server. See “Additional Information and
             Software” for a link to the list of compatible processor(s).
    Caution: ESD and handling processors: Reduce the risk of electrostatic discharge (ESD) damage to
             the processor by doing the following: (1) Touch the metal chassis before touching the
             processor or server board. Keep part of your body in contact with the metal chassis to
             dissipate the static charge while handling the processor. (2) Avoid moving
             around unnecessarily.
AF004572
6. Open the load plate (see letter “A” and “B” in Figure 46).
AF004573
AF004574
AF004580
AF003189
AF004575
AF004577
AF004576
AF004579
                                                                                             Save the
                                                                                             protective
                                                                                             cover.
AF004578
AF004580
     Note: Make sure the alignment triangle mark and the alignment triangle cutout align correctly.
           To assist in package orientation and alignment with the socket:
                                                                                  Note: Heatsink
                                                                                  styles may vary
                                                      2                           1
                                                                 A
                                                  E                   4
                                                           TIM
AF003526
Removing a Processor
                    1. Observe the safety and ESD precautions in “Safety Information”.
                    2. Turn off all peripheral devices connected to the server. Turn off the server.
                    3. Remove the AC power cord from the server.
                    4. Remove the server's cover. See the documentation that came with your server
                       chassis for instructions on removing the server's cover.
                    5. Unplug the processor fan cable from the server board.
                    6. Untie the four captive fastners from the corners of the heatsink.
     Note: You must attach add-in cards to a riser card when the riser card is removed from
           the chassis.
              1. Remove the screw that attaches the PCI bracket shield to the rear of the chassis to
                 remove the shield. Retain the screw.
                                                                         Riser Card
                                                                         Connector
AF003683
Figure 52. Removing the PCI Riser Assembly from the Server System
2. Insert the PCI card edge connector in the slot on the PCI riser.
                                                                  A
                                 B                                                                       Riser Card
                                                                                     Riser Assembly
                                                                                      Supports one
                                                                                       PCIe* card.
                                                    Add-in Card
                    3. Insert the riser card with the attached PCI card into the PCI slot on the server board.
                       Press firmly on the riser card until it is fully seated. Press down on the riser
                       card—do NOT press down on the PCI card.
    Caution: Press the riser card straight down into the slot. Tipping it in the slot while installing it may
             damage the riser card or slot on the server board.
                    4. Use the screw removed in Step 1 to secure the riser card assembly to the chassis.
     Warning: Danger of explosion if battery is incorrectly replaced. Replace only with the same or
              equivalent type recommended by the equipment manufacturer. Discard used batteries
              according to manufacturer's instructions.
     Advarsel: Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med
               batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
     Advarsel: Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av
               apparatfabrikanten. Brukt batteri returneres apparatleverandøren.
     Varning: Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ
              som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens
              instruktion.
     Varoitus: Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan
               laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden
               mukaisesti.
                 During the system boot process, the BIOS executes a number of platform configuration
                 processes, each of which is assigned a specific hex POST code number. As each
                 configuration routine is started, the BIOS displays the POST code to the POST Code
                 Diagnostic LEDs on the back edge of the server board. To assist in troubleshooting a
                 system hang during the POST process, you can use the Diagnostic LEDs to identify the
                 last POST process executed.
                 Each POST code is represented by the eight amber Diagnostic LEDs. The POST codes are
                 divided into two nibbles: an upper nibble and a lower nibble. The upper nibble bits are
                 represented by Diagnostic LEDs #4, #5, #6, and #7. The lower nibble bits are represented
                 by Diagnostics LEDs #0, #1, #2, and #3. Given the bit is set in the upper and lower
                 nibbles, the corresponding LED is lit. If the bit is clear, corresponding LED is off.
                 The Diagnostic LED #7 is labeled as MSB, and the Diagnostic LED #0 is labeled
                 with LSB.
                        A.   ID LED (For Intel® Server Board       B.   Status LED (For Intel® Server
                             S1200BTL/S1200BTLRM)                       Board S1200BTL//S1200BTLRM)
                 In the following example, the BIOS sends a value of ACh to the diagnostic LED decoder.
                 The LEDs are decoded as follows:
               MSB                                                                                           LSB
      LEDs
               LED #7      LED #6       LED #5      LED #4       LED #3     LED #2         LED #1            LED #0
8h 4h 2h 1h 8h 4h 2h 1h
               1           0            1           0            1          1              0                 0
     Results
               Ah                                                Ch
                    • Upper nibble bits = 1010b = Ah; Lower nibble bits = 1100b = Ch; the two are
                       concatenated as ACh.
SEC Phase
PEI Phase
DXE Phase
0x00 X X X X X X X X INT19
BIOS Recovery
        Note: Filling out this form completely is required for any escalation.
              ===============================================================
                 Server Chassis:
                 (Example P4304XXSFCN. If third-party chassis used, indicate make and model.)
                 ===============================================================
BMC/mBMC Version:
FRU/SDR Version:
HSC Version:
Processor information:
Processor 1
Processor 2
Processor 3
Processor 4
===============================================================
Memory:
===============================================================
Version:
                 Distribution (OEM/Retail):
                 ===============================================================
Troubleshooting tried:
                 ===============================================================
                 Issue impact statements:
                 Do you have any potential Intel system, or component purchases that this issue is
                 holding up? If yes, please provide a brief description below.
                 Do you have systems already purchased that are not being delivered to your
                 customers because of this issue? If yes, please provide a brief description below.
                 Have you returned systems or components to your place of purchase because of this
                 issue? If yes, please provide a brief description below.
*All other brands and names are property of their respective owners.
                 If you encounter an issue with your server system, follow these steps to obtain support:
                    1. Visit the following Intel support web page:
                       http://www.intel.com/support/motherboards/server
                       This web page provides 24x7 support when you need it to get the latest and most
                       complete technical support information on all Intel Enterprise Server and Storage
                       Platforms. Information available at the support site includes:
                       — Latest BIOS, firmware, drivers and utilities
                       — Product documentation, installation and quick start guides
                       — Full product specifications, technical advisories and errata
                       — Compatibility documentation for memory, hardware add-in cards, chassis
                         support matrix and operating systems
                       — Server and chassis accessory parts list for ordering upgrades or spare parts
                       — A searchable knowledgebase to search for product information throughout the
                         support site
                    2. If you are still unable to obtain a solution to your issue, send an email to Intel’s
                       technical support center using the online form available at
                       http://supportmail.intel.com/scripts-emf/welcome.aspx.
                    3. Lastly, you can contact an Intel support representative using one of the support
                       phone numbers available at http://www.intel.com/support/9089.htm
                       (charges may apply). Intel customer support suggests filling out the issue report
                       form available at “Intel® Server Issue Report Form” on page 89 to better service
                       the issue.
                       Intel also offers Channel Program members around-the-clock 24x7 technical phone
                       support on Intel® server boards, server chassis, server RAID controller cards, and
                       Intel® Server Management at http://www.intel.com/reseller/.
Note: You will need to log in to the Reseller site to obtain the 24x7 number.
Warranty Information
                 To obtain warranty information, visit the following Intel web site:
                 http://www.intel.com/support/motherboards/server/sb/CS-010807.htm.
                 This chapter helps you identify and solve problems that might occur while you are using
                 the system.
                 For any issue, first ensure you are using the latest firmware and files. Firmware upgrades
                 include updates for BIOS, the baseboard management controller (BMC), and the hot-swap
                 controller (HSC). See “Additional Information and Software” for a link to the software
                 updates. In addition to the server firmware and files, also update any drivers used for
                 components you installed in your system, such as video drivers, network drivers, and
                 SCSI drivers.
                 Intel provides a package called the "Platform Confidence Test" that may help with your
                 diagnostics. See “Additional Information and Software” for a link to this software.
                 If you cannot resolve your server problems on your own, see “Getting Help”
                 for assistance.
To do this Press
Soft boot reset to clear the system memory and reload the operating system <Ctrl+Alt+Del>
Clear system memory, restart POST, and reload the operating system Reset button
                   Cold boot reset. Turn the system power off and then on. This clears system    Power off/on
                   memory, restarts POST, reloads the operating system, and halts power to all   button
                   peripherals
    Caution: Turn off devices before disconnecting cables: Before disconnecting any peripheral cables
             from the system, turn off the system and any external peripheral devices. Failure to do so
             can cause permanent damage to the system and/or the peripheral devices.
                    1. Turn off the system and all external peripheral devices. Disconnect each device
                       from the system, except for the keyboard and the video monitor.
                    2. Make sure the system power cord is plugged into a properly grounded AC outlet.
                    3. Make sure your video display monitor and keyboard are correctly connected to the
                       system. Turn on the video monitor. Set its brightness and contrast controls to at
                       least two thirds of their maximum ranges (refer to the documentation supplied with
                       your video display monitor).
                    4. If the operating system normally loads from the hard disk drive, make sure there is
                       no diskette in drive A and no CD-ROM disk in the CD-ROM drive.
                    5. If the power LED does light, attempt to boot from a floppy diskette or from a CD-
                       ROM disk.
                    6. Turn on the system. If the power LED does not light, see “Power Light Does Not
                       Light”.
         Try the following solutions in the order given. If you cannot correct the problem, contact
         your service representative or authorized dealer for help.
         If you are using the onboard diskette controller, use the BIOS setup to make sure that
         “Onboard Floppy” is set to "Enabled." If you are using an add-in diskette controller, make
         sure that “Onboard Floppy” is set to “Disabled”.
        Note: Random errors in data files: If you are getting random errors in your data files, they may
              be getting corrupted by voltage spikes on your power line. If you are experiencing any of
              the above symptoms that might indicate voltage spikes on the power line, you may want to
              install a surge suppressor between the power outlet and the system power cord.
LED Information
                 The Intel® Server Board S1200BT includes LEDs that can aid in troubleshooting your
                 system. The following table lists these LEDs and provides a description of their use.
 ID (for Intel®      Aid in server                 Front panel      Blue              Press ID LED button or use
 Server Board        identification from the       and board rear                     Server Management
 S1200BTL/           back panel                    left corner                        software to turn the LED on
 S1200BTLRM)                                                                          and off.
 Disk Activity       Front panel                   Front panel      Green             Blinking = Activity. No action
                                                   and board left                     required.
                                                   side
 POST Code 1-8       Display boot 80 POST          Left rear of     Each LED can      See the POST code table.
                     code                          board            be Off, Green,
                                                                    Amber, or Red
 5-V Standby         Identify 5-V standby          Front left       Amber             On = 5-V standby power on
                     power on state                board
 Power LED           Identify the power state      Front panel      Green               •   Off = Power is off (off or
                     of the system                                                          S5)
                                                                                        •   On = Power on or S0)
                                                                                        •   Slow Blink = Low power
                                                                                            state (S1 - S3)
                                             POST Progress
      Beeps             Error Message                                            Description
                                                 Code
 3                  Memory error            Multiple         System halted because a fatal error related to the
                                                             memory was detected.
 The following Beep Codes are from the BMC, and are controlled by the Firmware team. They are listed here for
 convenience.
 1-5-4-2            Power fault             N/A              DC power unexpectedly lost (power good dropout)
                                                             - Power unit sensors report power unit failure offset
 1-5-4-4            Power control fault     N/A              Power good assertion timeout - Power unit sensors
                                                             report soft power control failure offset
                 In the case of POST error(s) that are listed as Major, the BIOS enters the error manager
                 and waits for the user to press an appropriate key before booting the operating system or
                 entering the BIOS Setup.
                 The user can override this option by setting the POST Error Pause option as disabled on
                 the BIOS setup Main screen. If this option is disabled, the system boots the operating
                 system without user intervention. The default is disabled.