Codesys 3
Codesys 3
CoDeSys V3
                         Ethernet Driver
1   System Configuration....................................................................................................... 3
2   External Device Selection ................................................................................................ 6
3   Communication Settings .................................................................................................. 7
4   Setup Items .................................................................................................................... 19
5   Supported Devices......................................................................................................... 24
6   Device Code and Address Code.................................................................................... 36
7   Error Messages.............................................................................................................. 37
                                                     1
                                                                                        CoDeSys V3 Ethernet Driver
   Introduction
      This manual describes how to connect the Display and the External Device (target PLC).
      In this manual, the connection procedure will be described in the sections identified below:
        1      System Configuration
                                                               "1 System Configuration" (page 3)
               This section lists the types of External
               Devices and SIO that you can connect.
        3      Communication Settings
                                                                 "3 Communication Settings" (page 7)
               This section shows setting examples for
               communicating between the Display and
               the External Device.
        4      Setup Items
                                                                 "4 Setup Items" (page 19)
               This section describes communication
               setup items on the Display. Set the
               Display’s communication settings in GP
               Pro-EX or in off-line mode.
Operation
1 System Configuration
      The system configuration for the Display connected to the CoDeSys Automation Alliance External Device is
      shown below.
                                                                             Communication
           Series                      CPU                 Link I/F                                 Setting Example
                                                                                Method
3S-Smart Software Solutions
                                                                                                   "Setting Example 1"
          GmbH                        PC/AT           Ethernet Interface      Ethernet (TCP)
                                                                                                         (page 7)
 CODESYS Control Win V3
                                       1006
 Hitachi Industrial Equipment
                                       1025                                                        "Setting Example 1"
      Systems Co., Ltd.                               Ethernet Interface      Ethernet (TCP)
                                       1051                                                              (page 7)
            EHV+
                                       1102
                                   HX-CP1S08
 Hitachi Industrial Equipment      HX-CP1H16
                                                                                                   "Setting Example 2"
      Systems Co., Ltd.           HX-CP1S08M          Ethernet Interface      Ethernet (TCP)
                                                                                                         (page 10)
              HX                  HX-CP1H16M
                                  HXC-CP1H16
    Lenze Vertrieb GmbH                                                                            "Setting Example 1"
                                      3200C           Ethernet Interface      Ethernet (TCP)
      Controller 3200C                                                                                   (page 7)
                                       M241                                                        "Setting Example 3"
                                                      Ethernet Interface      Ethernet (TCP)
    Schneider Electric SA              M251                                                              (page 13)
          Modicon                                                                                  "Setting Example 4"
                                       M262           Ethernet Interface      Ethernet (TCP)
                                                                                                         (page 16)
                     • Please refer to the latest list of the External Device to be supported by this driver on the Pro-
                        face’s website.
                        http://www.pro-face.com/product/soft/gpproex/driver/driver.html
                     • This driver does not support GP3000 Series, LT3000 Series, GP-4100 Series (Monochrome
                        Model), GP-4*01TM and GP-Rear Module.
     Connection Configuration
      •   1:1 Connection
• 1:n Connection
• n:1 Connection
      *   The number of Displays you can connect depends on the External Device. Check the specifications of the
          External Device.
• n:m Connection
      *   The number of Displays you can connect depends on the External Device. Check the specifications of the
          External Device.
Number of Devices/PLCs
                                  • When you set up the CoDeSys Automation Alliance CoDeSys V3 Ethernet driver,
                                    you can connect simultaneously up to two drivers (models that support four
                                    drivers) or one driver (models that support two drivers).
                                  Select the manufacturer of the External Device to be connected. Select "CoDeSys
Manufacturer
                                  Automation Alliance".
                                  Select a model (series) of the External Device to be connected and connection
                                  method. Select "CoDeSys V3 Ethernet".
Series                            Check the External Device which can be connected in "CoDeSys V3 Ethernet" in
                                  system configuration.
                                     "1 System Configuration" (page 3)
                                  Select the Display port to be connected to the External Device. Select [Ethernet
Port
                                  (TCP)].
                                  Check this option to synchronize the system data area of the Display and the device
                                  (memory) of the External Device. When synchronized, you can use the External
                                  Device’s ladder program to switch the display or display the window on the Display.
                                    Cf. GP-Pro EX Reference Manual "LS Area (Direct Access Method
                                          Area)"
Use System Area
                                  This feature can also be set in GP-Pro EX or in the Display's offline mode.
                                    Cf. GP-Pro EX Reference Manual "System Settings [Display Unit] -
                                          [System Area] Settings Guide"
                                    Cf. Maintenance/Troubleshooting Guide "Main Unit - System Area
                                          Settings"
3 Communication Settings
        Examples of communication settings of the Display and the External Device, recommended by Pro-face, are
        shown.
    Device Setting
      To display the [Individual Device Settings] dialog box, from [Device-Specific Settings] in the [Device/PLC]
      window, select the External Device and click [Settings]    . To connect multiple External Devices, from
      [Device-Specific Settings] in the [Device/PLC] window, click [Add Device] to add another External Device.
                      • When using a gateway, select the [Connect via Gateway] check box and set the gateway's IP
                        address and port number.
                      • While using a display unit other than IPC, PC/AT compatible machine, or SP5000 Series Open
                        Box and the gateway restarts, communication may not be restored. If that happens, restart the
                        display unit.
                      • Use the programming software for the External Device to check the gateway's node name,
                        node address and IP address.
                      • Check with a network administrator about IP address. Do not set the duplicate IP address in
                        the same network.
                      • Set up the External Device's IP address and Port Number in the [Individual Device Settings]
                        dialog box.
                      • Set up the Display's IP address in offline mode.
                       • When searching for External Devices, the External Device and host must exist on the same
                         network. Please refer to the manual of the External Device for more details.
4 Select the added External Device, and confirm the [Node Name] or [Node Address].
• When using a gateway, check the gateway's IP address and port number.
    Device Setting
      To display the [Individual Device Settings] dialog box, from [Device-Specific Settings] in the [Device/PLC]
      window, select the External Device and click [Settings]    . To connect multiple External Devices, from
      [Device-Specific Settings] in the [Device/PLC] window, click [Add Device] to add another External Device.
                      • When using a gateway, select the [Connect via Gateway] check box and set the gateway's IP
                        address and port number.
                      • While using a display unit other than IPC, PC/AT compatible machine, or SP5000 Series Open
                        Box and the gateway restarts, communication may not be restored. If that happens, restart the
                        display unit.
                      • Use the programming software for the External Device to check the gateway's node name,
                        node address and IP address.
                      • Check with a network administrator about IP address. Do not set the duplicate IP address in
                        the same network.
                      • Set up the External Device's IP address and Port Number in the [Individual Device Settings]
                        dialog box.
                      • Set up the Display's IP address in offline mode.
                       • To search for External Devices, the External Device must be on the same network as the host.
                         For information, refer to the manual of the External Device.
   6   From the [Online] menu select [Login], and log in to the External Device.
   7   Download the project and restart the External Device.
    Device Setting
      To display the [Individual Device Settings] dialog box, from [Device-Specific Settings] in the [Device/PLC]
      window, select the External Device and click [Settings]    . To connect multiple External Devices, from
      [Device-Specific Settings] in the [Device/PLC] window, click [Add Device] to add another External Device.
                      • When using a gateway, select the [Connect via Gateway] check box and set the gateway's IP
                        address and port number.
                      • While using a display unit other than IPC, PC/AT compatible machine, or SP5000 Series Open
                        Box and the gateway restarts, communication may not be restored. If that happens, restart the
                        display unit.
                      • Use the programming software for the External Device to check the gateway's node name,
                        node address and IP address.
                      • Check with a network administrator about IP address. Do not set the duplicate IP address in
                        the same network.
                      • In the [Node Name (or) Address] field, set the device name of the External Device. You
                        cannot use the IP address for communication.
                      • Set up the Display's IP address in offline mode.
7 Click [OK].
                       • When communicating with GP-Pro EX, set the Device name for the External Device. IP
                          addresses cannot be used for communication.
    Device Setting
      To display the [Individual Device Settings] dialog box, from [Device-Specific Settings] in the [Device/PLC]
      window, select the External Device and click [Settings]    . To connect multiple External Devices, from
      [Device-Specific Settings] in the [Device/PLC] window, click [Add Device] to add another External Device.
                      • When using a gateway, select the [Connect via Gateway] check box and set the gateway's IP
                        address and port number.
                      • While using a display unit other than IPC, PC/AT compatible machine, or SP5000 Series Open
                        Box and the gateway restarts, communication may not be restored. If that happens, restart the
                        display unit.
                      • Use the programming software for the External Device to check the gateway's node name,
                        node address and IP address.
                      • Check with a network administrator about IP address. Do not set the duplicate IP address in
                        the same network.
                      • Set up the External Device's IP address and Port Number in the [Individual Device Settings]
                        dialog box.
                      • Set up the Display's IP address in offline mode.
7 Click [OK].
4 Setup Items
        Set communication settings of the Display with GP-Pro EX or in offline mode of the Display.
        The setting of each parameter must be identical to that of External Device.
        "3 Communication Settings" (page 7)
                        • Set the Display’s IP address in off-line mode.
    Device Setting
      To display the [Individual Device Settings] dialog box, from [Device-Specific Settings] in the [Device/PLC]
      window, select the external device and click [Settings]      .
      To connect multiple External Devices, from [Device-Specific Settings] in the [Device/PLC] window, click [Add
      Device] to add another External Device.
       Communication Settings
        To display the setting screen, touch [Device/PLC Settings] from [Peripheral Settings] in offline mode. Touch the
        External Device you want to set from the displayed list.
    Device Setting
      To display the setting screen, touch [Device/PLC Settings] from [Peripheral Settings]. Touch the External Device
      you want to set from the displayed list, and touch [Device].
IP Address(Tcp)
                           • Check with a network administrator about IP address. Do not set the duplicate IP
                             address.
Tcp Port                   Enter the External Device's port number.
                           Select [Enable] when the connected External Device performs user management. Use the
UserManagement             user name and password set in GP-Pro EX.
                            "  Device Setting" (page 20)
                           When using a gateway, select [Enable].
Gateway
                           When you select [Disable], the [Gateway IP] and [Gateway Port] properties are disabled.
                           Set the gateway's IP address.
Gateway IP
                           • Check with a network administrator about IP address. Do not set the duplicate IP
                             address.
Gateway Port               Enter the gateway's port number.
5 Supported Devices
      Range of supported device addresses is shown in the table below. Please note that the actual supported range of
      devices varies on the External Device in use. Please check the actual range in the manual for your connected
      equipment.
You can import tag data from the project created by your programming software.
• When connecting with EHV+ Series, arrays cannot be used for the Display.
Cf. GP-Pro EX Reference Manual "LS Area (Direct Access Method Area)"
• Please refer to the precautions on manual notation for icons in the table.
8 Click [Import].
9 From [Select File] click [Browse..], and select the symbol data (xml file).
                  • Please refer to "Using Device/PLC Tags" of the GP-Pro EX Reference Manual for the importing
                     tag.
8 Click [Import].
9 From [Select File] click [Browse..], and select the symbol data (xml file).
                  • Please refer to "Using Device/PLC Tags" of the GP-Pro EX Reference Manual for the importing
                     tag.
    Schneider Electric SA
   1   In the configuration tool, create a symbol.
   2   Build the project. On build, symbol data (xml file) is generated.
   3   In GP-Pro EX, display the [Individual Device Settings] dialog box and select the [Use Tag Data] check box.
5 Click [Import].
6 From [Select File] click [Browse..], and select the symbol data (xml file).
                  • Please refer to "Using Device/PLC Tags" of the GP-Pro EX Reference Manual for the importing
                     tag.
7 Error Messages
      Error messages are displayed on the screen of Display as follows: "No. : Device Name: Error Message (Error
      Occurrence Area)". Each description is shown below.
         Item                                                    Description
No.                       Error No.
                          Name of External Device where error occurs. Device name is a title of External Device set
Device Name
                          with GP-Pro EX. (Initial value [PLC1])
Error Message             Displays messages related to the error which occurs.
                          Displays IP address or device address of External Device where error occurs, or error codes
                          received from External Device.
                     • Refer to your External Device manual for details on received error codes.
                     • Refer to "Display-related errors" in "Maintenance/Troubleshooting Guide" for details on the
                        error messages common to the driver.