Circuit Breaker Catalogue

The document summarizes the features of iC60N circuit breakers from Schneider Electric. The circuit breakers provide circuit protection against short-circuit currents and overload currents. They are suitable for industrial isolation according to IEC/EN 60947-2 standards. Fault tripping is indicated by a red mechanical indicator on the front face. The circuit breakers also allow safe work on downstream circuits when the contacts are open, guaranteed by the presence of a green strip.

Uploaded by

Le Duc Thanh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
189 views4 pages

Circuit Breaker Catalogue

The document summarizes the features of iC60N circuit breakers from Schneider Electric. The circuit breakers provide circuit protection against short-circuit currents and overload currents. They are suitable for industrial isolation according to IEC/EN 60947-2 standards. Fault tripping is indicated by a red mechanical indicator on the front face. The circuit breakers also allow safe work on downstream circuits when the contacts are open, guaranteed by the presence of a green strip.

Uploaded by

Le Duc Thanh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Circuit protection www.schneider-electric.com/sg Circuit protection www.schneider-electric.

com/sg

iC60N circuit breakers iC60N circuit breakers


Curve B, C, D Curve B, C, D
IEC/EN 60947-2, IEC/EN 60898-1
• iC60N circuit breakers are multi-standard circuit breakers which combine the
following functions: • Insulated terminals IP20
- circuit protection against short-circuit currents,
- circuit protection against overload currents,
- suitable for industrial isolation according to IEC/EN 60947-2, standard.
- fault tripping indication by a red mechanical indicator in circuit breaker front face.
PB104437-40

PB104450-40

Alternating current (AC) 50/60 Hz


Breaking capacity (Icu) according to IEC/EN 60947-2 Service
Voltage (Ue) breaking
capacity (Ics) Visi-trip window
Ph/Ph (2P, 3P, 4P) 12 to 133 V 220 to 240 V 380 to 415 V 440 V • Fault tripping is indicated by a red
Ph/N (1P, 1P+N) 12 to 60 V 100 to 133 V 220 to 240 V - mechanical indicator on the front face
Rating (In) 0.5 to 4 A 50 kA 50 kA 50 kA 25 kA 100 % of Icu
6 to 63 A 36 kA 20 kA 10 kA 6 kA 75 % of Icu Large circuit Positive contact indication
Breaking capacity (Icn) according to IEC/EN 60898-1 labelling area • Suitable for industrial isolation according
Voltage (Ue) to IEC/EN 60947-2 standard.
Ph/Ph 400 V • T
 he presence of the green strip
Ph/N 230 V
guarantees physical opening of the
Rating (In) 0.5 to 63 A 6000 A
contacts and allows operations to be
performed on the downstream circuit in
complete safety
Direct current (DC)
Breaking capacity (Icu) according to IEC/EN 60947-2 Service • D
 ouble clip for
• Increased product service life thanks to:
breaking dismounting with
Voltage (Ue) - overvoltage resistance by high level of industrial performances conception
capacity comb busbar in place (pollution degree, rated impulse withstand voltage and insulation voltage),
Between +/- 12 to 60 V y 72 V y 125 V y 180 V y 250 V (Ics)
- high performance limitation (see limitation curves),
Number of poles 1P 2P 3P 4P
- fast closing independent of the speed of actuation of the toggle.
Rating (In) 0.5 to 63 A 15 kA 10 kA 10 kA 10 kA 10 kA 100 % of Icu
• Remote indication, open/closed/tripped, by optional auxiliary contacts.
Top or bottom electrical feeding.
Catalogue numbers
iC60N circuit breaker
Type 1P 2P Type 3P 4P
E45092

E45094

E45095

E45097
1 1 3 1 3 5 1 3 5 7

2 2 4 2 4 6 2 4 6 8

Auxiliaries Remote tripping and indication, module CA907000 Remote tripping and indication, module CA907000 Auxiliaries Remote tripping and indication, module CA907000 Remote tripping and indication, module CA907000
and CA907002 and CA907002 and CA907002 and CA907002
Vigi iC60 Vigi iC60 add-on residual current device, module CA902005 Vigi iC60 add-on residual current device, module CA902005 Vigi iC60 Vigi iC60 add-on residual current device, module CA902005 Vigi iC60 add-on residual current device, module CA902005
Rating Curve Curve Rating Curve Curve
(In) (In)
B C D B C D B C D B C D
0.5 A A9F73170 A9F74170 A9F75170 A9F73270 A9F74270 A9F75270 0.5 A A9F73370 A9F74370 A9F75370 A9F73470 A9F74470 A9F75470
1A A9F73101 A9F74101 A9F75101 A9F73201 A9F74201 A9F75201 1A A9F73301 A9F74301 A9F75301 A9F73401 A9F74401 A9F75401
2A A9F73102 A9F74102 A9F75102 A9F73202 A9F74202 A9F75202 2A A9F73302 A9F74302 A9F75302 A9F73402 A9F74402 A9F75402
3A A9F73103 A9F74103 A9F75103 A9F73203 A9F74203 A9F75203 3A A9F73303 A9F74303 A9F75303 A9F73403 A9F74403 A9F75403
4A A9F73104 A9F74104 A9F75104 A9F73204 A9F74204 A9F75204 4A A9F73304 A9F74304 A9F75304 A9F73404 A9F74404 A9F75404
6A A9F73106 A9F74106 A9F75106 A9F73206 A9F74206 A9F75206 6A A9F73306 A9F74306 A9F75306 A9F73406 A9F74406 A9F75406
10 A A9F73110 A9F74110 A9F75110 A9F73210 A9F74210 A9F75210 10 A A9F73310 A9F74310 A9F75310 A9F73410 A9F74410 A9F75410
13 A A9F73113 A9F74113 A9F75113 A9F73213 A9F74213 A9F75213 13 A A9F73313 A9F74313 A9F75313 A9F73413 A9F74413 A9F75413
16 A A9F73116 A9F74116 A9F75116 A9F73216 A9F74216 A9F75216 16 A A9F73316 A9F74316 A9F75316 A9F73416 A9F74416 A9F75416
20 A A9F73120 A9F74120 A9F75120 A9F73220 A9F74220 A9F75220 20 A A9F73320 A9F74320 A9F75320 A9F73420 A9F74420 A9F75420
25 A A9F73125 A9F74125 A9F75125 A9F73225 A9F74225 A9F75225 25 A A9F73325 A9F74325 A9F75325 A9F73425 A9F74425 A9F75425
32 A A9F73132 A9F74132 A9F75132 A9F73232 A9F74232 A9F75232 32 A A9F73332 A9F74332 A9F75332 A9F73432 A9F74432 A9F75432
40 A A9F73140 A9F74140 A9F75140 A9F73240 A9F74240 A9F75240 40 A A9F73340 A9F74340 A9F75340 A9F73440 A9F74440 A9F75440
50 A A9F73150 A9F74150 A9F75150 A9F73250 A9F74250 A9F75250 50 A A9F73350 A9F74350 A9F75350 A9F73450 A9F74450 A9F75450
63 A A9F73163 A9F74163 A9F75163 A9F73263 A9F74263 A9F75263 63 A A9F73363 A9F74363 A9F75363 A9F73463 A9F74463 A9F75463
Width in 9-mm modules 2 4 Width in 9-mm modules 6 8
Accessories Module CA907000 and CA907001 Module CA907000 and CA907001 Module CA907000 and CA907001 Module CA907000 and CA907001

8 Version 2.0 - May 2017 Version 2.0 - May 2017 9


Acti9 Acti9
Circuit protection www.schneider-electric.com/sg Circuit protection www.schneider-electric.com/sg

iC60H circuit breakers iC60H circuit breakers


Curve B, C, D Curve B, C, D

Catalogue numbers Connection Without accessories With accessories


iC60H circuit breaker Rating Tightening Copper cables 50 mm² Screw-on Multi-cables terminal
Type 1P 2P 3P 4P torque Al terminal connection for
Rigid Flexible or with Rigid Flexible

DB123060
14 mm ring terminal
1 1 3 1 3 5 1 3 5 7 6.5 mm ferrule cables cables
E45092

E45094

E45095

E45097
PZ2

DB122945

DB122946

DB122935

DB118789

DB118787
2 2 4 2 4 6 2 4 6 8 0.5 to 25 A 2 N.m 1 to 25 mm2 1 to 16 mm2 - Ø 5 mm - -
Auxiliaries Remote tripping and indication, Remote tripping and indication, Remote tripping and indication, Remote tripping and indication, 32 to 63 A 3.5 N.m 1 to 35 mm2 1 to 25 mm2 50 mm2 3 x 16 mm2 3 x 10 mm2
module CA907000 and module CA907000 and module CA907000 and module CA907000 and
CA907002 CA907002 CA907002 CA907002
Vigi iC60 Vigi iC60 add-on residual Vigi iC60 add-on residual Vigi iC60 add-on residual Vigi iC60 add-on residual
current device, module current device, module current device, module current device, module
CA902005 CA902005 CA902005 CA902005
Technical data

DB123310
Rating (In) Curve Curve Curve Curve
B C D B C D B C D B C D Main characteristics
0.5 A A9F83170 A9F84170 A9F85170 A9F83270 A9F84270 A9F85270 A9F83370 A9F84370 A9F85370 A9F83470 A9F84470 A9F85470 According to IEC/EN 60947-2
1A A9F83101 A9F84101 A9F85101 A9F83201 A9F84201 A9F85201 A9F83301 A9F84301 A9F85301 A9F83401 A9F84401 A9F85401 Insulation voltage (Ui) 500 V AC
2A A9F83102 A9F84102 A9F85102 A9F83202 A9F84202 A9F85202 A9F83302 A9F84302 A9F85302 A9F83402 A9F84402 A9F85402 Pollution degree 3
3A A9F83103 A9F84103 A9F85103 A9F83203 A9F84203 A9F85203 A9F83303 A9F84303 A9F85303 A9F83403 A9F84403 A9F85403 Rated impulse withstand voltage (Uimp) 6 kV
4A A9F83104 A9F84104 A9F85104 A9F83204 A9F84204 A9F85204 A9F83304 A9F84304 A9F85304 A9F83404 A9F84404 A9F85404 Clip on DIN rail 35 mm.
Thermal tripping Reference temperature 50 °C
6A A9F83106 A9F84106 A9F85106 A9F83206 A9F84206 A9F85206 A9F83306 A9F84306 A9F85306 A9F83406 A9F84406 A9F85406
Temperature derating See module CA908007
10 A A9F83110 A9F84110 A9F85110 A9F83210 A9F84210 A9F85210 A9F83310 A9F84310 A9F85310 A9F83410 A9F84410 A9F85410
Magnetic tripping B curve 4 In ± 20 %
13 A A9F83113 A9F84113 A9F85113 A9F83213 A9F84213 A9F85213 A9F83313 A9F84313 A9F85313 A9F83413 A9F84413 A9F85413

DB123312
16 A A9F83116 A9F84116 A9F85116 A9F83216 A9F84216 A9F85216 A9F83316 A9F84316 A9F85316 A9F83416 A9F84416 A9F85416
C curve 8 In ± 20 %
20 A A9F83120 A9F84120 A9F85120 A9F83220 A9F84220 A9F85220 A9F83320 A9F84320 A9F85320 A9F83420 A9F84420 A9F85420 D curve 12 In ± 20 %
25 A A9F83125 A9F84125 A9F85125 A9F83225 A9F84225 A9F85225 A9F83325 A9F84325 A9F85325 A9F83425 A9F84425 A9F85425 Utilization category A
32 A A9F83132 A9F84132 A9F85132 A9F83232 A9F84232 A9F85232 A9F83332 A9F84332 A9F85332 A9F83432 A9F84432 A9F85432 According to IEC/EN 60898-1
40 A A9F83140 A9F84140 A9F85140 A9F83240 A9F84240 A9F85240 A9F83340 A9F84340 A9F85340 A9F83440 A9F84440 A9F85440 Limitation class 3
50 A A9F83150 A9F84150 A9F85150 A9F83250 A9F84250 A9F85250 A9F83350 A9F84350 A9F85350 A9F83450 A9F84450 A9F85450
Rated making and breaking capacity of an Icn1 = Icn
63 A A9F83163 A9F84163 A9F85163 A9F83263 A9F84263 A9F85263 A9F83363 A9F84363 A9F85363 A9F83463 A9F84463 A9F85463 Indifferent position of installation. individual pole (Icn1)
Width in 9-mm modules 2 4 6 8
Additional characteristics
Accessories Module CA907000 and Module CA907000 and Module CA907000 and Module CA907000 and Breaking capacity 40 A 4 kA
CA907001 CA907001 CA907001 CA907001 IP20 IP40 under 1 pole with 50/63 A 3 kA
IT 380-415 V isolated

DB123314
neutral system (case
of double fault)
Degree of protection Device only IP20
(IEC 60529) Device in modular IP40
enclosure Insulation class II
Endurance (O-C) Electrical 10,000 cycles
Mechanical 20,000 cycles
Overvoltage category (IEC 60364) IV
Operating temperature -35°C to +70°C
Storage temperature -40°C to +85°C
Tropicalization (IEC 60068-1) Treatment 2 (relative humidity 95 % to 55°C)

Weight (g) Dimensions (mm)


78.5

DB123392
4P 72
Circuit-breaker 69.5
3P 54
50
Type iC60H 1P+N / 2P 36
5.5
1P 125 1P 18

2P 250
4.4
3P 375
4P 500 94 85 45

64
4.6

12 Version 2.0 - May 2017 Version 2.0 - May 2017 13


Acti9 Acti9
Circuit protection www.schneider-electric.com/sg Circuit protection www.schneider-electric.com/sg

iC60L circuit breakers iC60L circuit breakers


Curve B, C, K, Z Curve B, C, K, Z

IEC/EN 60947-2, IEC/EN 60898-1 up to 40 A


• iC60L circuit breakers are multi-standard circuit breakers which combine the • Insulated terminals IP20
following functions:
- circuit protection against short-circuit currents,
- circuit protection against overload currents,
- suitable for industrial isolation according to IEC/EN 60947-2, standard.
- fault tripping indication by a red mechanical indicator in circuit breaker front face.

Alternating current (AC) 50/60 Hz


Breaking capacity (Icu) according to IEC/EN 60947-2 Service Visi-trip window
Voltage (Ue) breaking
capacity • F
 ault tripping is indicated by a
Ph/Ph (2P, 3P, 4P) 12 to 133 V 220 to 240 V 380 to 415 V 440 V
(Ics) red mechanical indicator on the
Ph/N (1P) 12 to 60 V 100 to 133 V 220 to 240 V -
front face
Rating 0.5 to 4 A 100 kA 100 kA 100 kA 70 kA 100 % of Icu
(In) 6 to 25 A 70 kA 50 kA 25 kA 20 kA 50 % of Icu (1)
32 / 40 A 70 kA 36 kA 20 kA 15 kA 50 % of Icu • L
 arge circuit Positive contact indication
50 / 63 A 70 kA 30 kA 15 kA 10 kA 50 % of Icu labelling area • S
 uitable for industrial isolation according
Breaking capacity (Icn) according to IEC/EN 60898-1 to IEC/EN 60947-2 standard.
Voltage (Ue) • The presence of the green strip
Ph/Ph 400 V
guarantees physical opening of the
Ph/N 230 V
contacts and allows operations to be
Rating 0.5 to 40 A 15000 A
performed on the downstream circuit in
(In) complete safety
• D
 ouble clip for
Direct current (DC) dismounting with • Increased product service life thanks to:
- overvoltage resistance by high level of industrial performances conception
Breaking capacity (Icu) according to IEC/EN 60947-2 Service comb busbar in place
breaking (pollution degree, rated impulse withstand voltage and insulation voltage),
Voltage (Ue) - high performance limitation (see limitation curves),
capacity
Between +/- 12 to 60 V y 72 V y 125 V y 180 V y 250 V - fast closing independent of the speed of actuation of the toggle.
(Ics)
Number of poles 1P 2P 3P 4P • Remote indication, open/closed/tripped, by optional auxiliary contacts.
Rating (In) 0.5 to 63 A 25 kA 20 kA 20 kA 20 kA 20 kA 100 % of Icu • Top or bottom electrical feeding.

Catalogue numbers
iC60L circuit breaker

E45095

E45097
Type 1P 2P 3P 4P
1 1 3 1 3 5 1 3 5 7
E45092

E45094

2 4 6 2 4 6 8
2 2 4

Auxiliaries Remote tripping and indication, module CA907000 Remote tripping and indication, module CA907000 Remote tripping and indication, module CA907000 and CA907002 Remote tripping and indication, module CA907000 and CA907002
and CA907002 and CA907002
Vigi iC60 Vigi iC60 add-on residual current device, module CA902005 Vigi iC60 add-on residual current device, module CA902005 Vigi iC60 add-on residual current device, module CA902005 Vigi iC60 add-on residual current device, module CA902005
Rating (In) Quality label Curve Curve Curve Curve
(2)
B C K Z B C K Z B C K Z B C K Z
0.5 A A9F93170 A9F94170 A9F95170 A9F92170 A9F93270 A9F94270 A9F95270 A9F92270 A9F93370 A9F94370 A9F95370 A9F92370 A9F93470 A9F94470 A9F95470 A9F92470
1A A9F93101 A9F94101 A9F95101 A9F92101 A9F93201 A9F94201 A9F95201 A9F92201 A9F93301 A9F94301 A9F95301 A9F92301 A9F93401 A9F94401 A9F95401 A9F92401
1.6 A - - A9F95172 A9F92172 - - A9F95272 A9F92272 - - A9F95372 A9F92372 - - A9F95472 A9F92472
2A A9F93102 A9F94102 A9F95102 A9F92102 A9F93202 A9F94202 A9F95202 A9F92202 A9F93302 A9F94302 A9F95302 A9F92302 A9F93402 A9F94402 A9F95402 A9F92402
3A A9F93103 A9F94103 A9F95103 A9F92103 A9F93203 A9F94203 A9F95203 A9F92203 A9F93303 A9F94303 A9F95303 A9F92303 A9F93403 A9F94403 A9F95403 A9F92403
4A A9F93104 A9F94104 A9F95104 A9F92104 A9F93204 A9F94204 A9F95204 A9F92204 A9F93304 A9F94304 A9F95304 A9F92304 A9F93404 A9F94404 A9F95404 A9F92404
6A A9F93106 A9F94106 A9F95106 A9F92106 A9F93206 A9F94206 A9F95206 A9F92206 A9F93306 A9F94306 A9F95306 A9F92306 A9F93406 A9F94406 A9F95406 A9F92406
10 A A9F93110 A9F94110 A9F95110 A9F92110 A9F93210 A9F94210 A9F95210 A9F92210 A9F93310 A9F94310 A9F95310 A9F92310 A9F93410 A9F94410 A9F95410 A9F92410
16 A A9F93116 A9F94116 A9F95116 A9F92116 A9F93216 A9F94216 A9F95216 A9F92216 A9F93316 A9F94316 A9F95316 A9F92316 A9F93416 A9F94416 A9F95416 A9F92416
20 A A9F93120 A9F94120 A9F95120 A9F92120 A9F93220 A9F94220 A9F95220 A9F92220 A9F93320 A9F94320 A9F95320 A9F92320 A9F93420 A9F94420 A9F95420 A9F92420
25 A A9F93125 A9F94125 A9F95125 A9F92125 A9F93225 A9F94225 A9F95225 A9F92225 A9F93325 A9F94325 A9F95325 A9F92325 A9F93425 A9F94425 A9F95425 A9F92425
32 A A9F93132 A9F94132 A9F95132 A9F92132 A9F93232 A9F94232 A9F95232 A9F92232 A9F93332 A9F94332 A9F95332 A9F92332 A9F93432 A9F94432 A9F95432 A9F92432
40 A A9F93140 A9F94140 A9F95140 A9F92140 A9F93240 A9F94240 A9F95240 A9F92240 A9F93340 A9F94340 A9F95340 A9F92340 A9F93440 A9F94440 A9F95440 A9F92440
50 A A9F93150 A9F94150 A9F95150(3) A9F92150 A9F93250 A9F94250 A9F95250 A9F92250 A9F93350 A9F94350 A9F95350 A9F92350 A9F93450 A9F94450 A9F95450 A9F92450
63 A A9F93163 A9F94163 A9F95163(3) A9F92163 A9F93263 A9F94263 A9F95263 A9F92263 A9F93363 A9F94363 A9F95363 A9F92363 A9F93463 A9F94463 A9F95463 A9F92463
Width in 9-mm modules 2 4 4 6
Accessories Module CA907000 and CA907001 Module CA907000 and CA907001 Module CA907000 and CA907001 Module CA907000 and CA907001
(1) 100 % of Icu for ratings 6 to 25 A under Ue 100 to 133 V AC Ph/Ph and Ue 12 to 60 V AC Ph/N.
(2) Information to be provided by the country.
(3) Without approval.

14 Version 2.0 - May 2017 Version 2.0 - May 2017 15


Acti9 Acti9
Circuit protection www.schneider-electric.com/sg Circuit protection www.schneider-electric.com/sg

iC60L circuit breakers iC60L circuit breakers


Curve MA, instantaneous circuit breakers (ICB) Curve MA, instantaneous circuit breakers (ICB)

IEC/EN 60947-2 • Insulated terminals IP20


• iC60L curve MA circuit breakers combine the following functions:
- circuit protection against short-circuit currents,
- suitability for industrial isolation according to IEC/EN 60947-2, standard,
- fault tripping indication by a red mechanical indicator in circuit breaker
front face,
- to be associated with overload protection for motor.
PB104443-40

PB104448-40

Alternating current (AC) 50/60 Hz Visi-trip window


• F
 ault tripping is indicated by a red
Breaking capacity (Icu) according to IEC/EN 60947-2 Service
breaking mechanical indicator on the front face
Voltage (Ue)
capacity
Ph/Ph (2P, 3P) 220 to 240 V 380 to 415 V 440 V (Ics) • L
 arge circuit
Rating (In) 1.6 to 16 A 40 kA 20 kA 15 kA 50 % of Icu labelling area
Positive contact indication
25 à 40 A 30 kA 15 kA 10 kA 50 % of Icu
• S
 uitable for industrial isolation according to
IEC/EN 60947-2 standard.
• The presence of the green strip guarantees
physical opening of the contacts and allows
operations to be performed on the
downstream circuit in complete safety
• D
 ouble clip for
dismounting with comb
Catalogue numbers busbar in place
iC60L instantaneous trip circuit breaker
• Increased product service life thanks to:
Type 2P 3P
- overvoltage resistance by high level of industrial performances conception
1 3 1 3 5
DB123810

DB123811

(pollution degree, rated impulse withstand voltage and insulation voltage),


- high performance limitation (see limitation curves),
- fast closing independent of the speed of actuation of the toggle.
• Remote indication, open/closed/tripped, by optional auxiliary contacts.
2 4 2 4 6
• Top or bottom electrical feeding.

Auxiliaries Remote tripping and indication, Remote tripping and indication,


module CA907000 and CA907002 module CA907000 and CA907002
Vigi iC60 Vigi iC60 add-on residual current device, module CA902005 Vigi iC60 add-on residual current device, module CA902005
Rating (In) Quality label (1) Curve MA Curve MA
1.6 A A9F90272 A9F90372
2.5 A A9F90273 A9F90373
4A A9F90204 A9F90304
6.3 A A9F90276 A9F90376
10 A A9F90210 A9F90310
12.5 A A9F90282 A9F90382
16 A A9F90216 A9F90316
25 A A9F90225 A9F90325
40 A A9F90240 A9F90340
Width in 9-mm modules 4 6
Accessories Module CA907000 and CA907001 Module CA907000 and CA907001
(1) Information to be provided by the country.