Solar Inverter Solutions Guide
Solar Inverter Solutions Guide
Solar Solutions
POWER ELECTRONICS CONTENTS
PE genetics Page. 4 — 7
Our secret
Page. 50 — 51
POWER ELECTRONICS OUR GENETICS
More than
GW
of installed
AC power
Solar + Storage
+
25
of annual
GW
production
capacity
+10k
solar inverters sold
+
30
years of
+ 25 excellence
1166 solar projects
#1 Manufacturer of solar International
inverters in America,
around the world Europe and Oceania. delegations
4 5
POWER ELECTRONICS OUR GENETICS
References
Our success
Freesun is the Power Electronics solar inverters range. Power around the world
Electronics has become the leading supplier of large-scale plant
installations in America, Europe and Oceania and continues to
expand worldwide.
Long-lasting
SOLAR INVERTERS
Designed for utility-scale solar applications that require the advantages of a
central inverter combined with the modular design of string architecture.
Smart
6 7
POWER ELECTRONICS OUR PRODUCTS
INVERTER
8 9
POWER ELECTRONICS OUR PRODUCTS
These product
has the following
characteristics
HEMK
1
Scan me!
Easy maintenance
Offers the advantages of both central The advantages of a central inverter with
and string inverters. The full front access the modularity of the string inverters.
simplifies the maintenance tasks. Designed to be easily replaceable on the field with a
safe, reliable, and fast Plug&Play assembly system.
Bus Plus
2
Combine solar and storage.
The Bus Plus feature allows the connection of up
to four Freemaq DC/DC converters. It’s the most
cost-competitive solution for solar-plus-storage
retrofits.
3Active heating
When the unit is not actively exporting power, the
inverter can import a small amount of power to keep
the inverter internal ambient temperature above -20°C,
without using external resistors.
10 11
POWER ELECTRONICS OUR PRODUCTS
5
Three-level
topology
The 3 level IGBT topology reduces stage losses,
increases inverter efficiency, and minimizes total
harmonic distortion. High efficiency to deliver
the lowest cost of energy (LCOE).
12 13
POWER ELECTRONICS OUR PRODUCTS
HEMK
King of compacts
STRING INVERTER
CABINETS
1500
Up to
6
different
AC voltages
4.39
Can reach up to a
nominal power of
DC-coupled
storage system MVA
from 1200 kW to
4800 kW
DC CABINET AUXILIARY
PANEL
14 15
POWER ELECTRONICS OUR PRODUCTS
HEMK HEMK
REFERENCES
AC Output Power (kVA/kW) @40°C[1]
FRAME 2
FS2195K
2195
690V
FRAME 3
FS3290K
3290
FRAME 4
FS4390K
4390
REFERENCES
AC Output Power (kVA/kW) @40°C [1]
FRAME 2
FS2101K
2100
FRAME 3
FS3151K
3150
660V FRAME 4
FS4200K
4200
AC Output Power (kVA/kW) @50°C[1] 2035 3055 4075 AC Output Power (kVA/kW) @50°C[1] 1950 2925 3900
Max. AC Output Current (A) @40°C 1837 2756 3674 Max. AC Output Current (A) @40°C 1837 2756 3674
Operating Grid Voltage (VAC) 690V ±10%
OUTPUT OUTPUT Operating Grid Voltage (VAC) 660V ±10%
Operating Grid Frequency (Hz) 50/60Hz
Operating Grid Frequency (Hz) 50/60Hz
Current Harmonic Distortion (THDi) < 3% per IEEE519
Current Harmonic Distortion (THDi) < 3% per IEEE519
Power Factor (cosine phi)[2] 0.5 leading … 0.5 lagging adjustable / Reactive power injection at
night Power Factor (cosine phi)[2] 0.5 leading … 0.5 lagging adjustable / Reactive power injec-
tion at night
DC Voltage Range[3] 976V - 1500V
Maximum DC Voltage 1500V
DC Voltage Range [3]
934V - 1500V
Number of Inputs Up to 40 Maximum DC Voltage 1500V
INPUT Max. DC Continuous Current (A)[4] 2295 3443 4590 Number of Inputs Up to 40
Max. DC Short Circuit Current (A)[4] 3470 5205 6940 INPUT Max. DC Continuous Current (A)[4] 2295 3443 4590
Number of MPPt (floating systems) 1 1 1, optionally 2 or 4 Max. DC Short Circuit Current (A)[4] 3470 5205 6940
Number of Freemaq DC/DC [4] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced) Number of MPPt (floating systems) 1 1 1, optionally 2 or 4
Efficiency (Max) (η) 98.84% 98.87% 98.93% Number of Freemaq DC/DC [4] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced)
EFFICIENCY
Euroeta (η) 98.45% 98.48% 98.65% Efficiency (Max) (η) 98.81% 98.84% 98.90%
EFFICIENCY
Dimensions [WxDxH] (ft) 9.8 x 6.6 x 7.2 Euroeta (η) 98.45% 98.48% 98.65%
Dimensions [WxDxH] (m) 3.0 x 2.0 x 2.2 Dimensions [WxDxH] (ft) 9.8 x 6.6 x 7.2
CABINET Weight (lbs) 11465 11795 12125 Dimensions [WxDxH] (m) 3.0 x 2.0 x 2.2
Weight (kg) 5200 5350 5500 CABINET Weight (lbs) 11465 11795 12125
Type of Ventilation Forced air cooling Weight (kg) 5200 5350 5500
Degree of Protection NEMA 3R / IP55 Type of Ventilation Forced air cooling
Permissible Ambient Temperature -35°C to +60°C, >50°C / Active Power derating
ENVIROMENT Degree of Protection NEMA 3R / IP55
Relative Humidity 4% to 100% non-condensing
Permissible Ambient Temperature -35°C to +60°C, >50°C / Active Power derating
Max. Altitude (above sea level) 2000m / >2000m power derating (Max. 4000m) ENVIROMENT
Relative Humidity 4% to 100% non-condensing
Communication Protocol Modbus TCP
Max. Altitude (above sea level) 2000m / >2000m power derating (Max. 4000m)
CONTROL INTERFACE Power Plant Controller Optional
Keyed ON/OFF Switch Standard Communication Protocol Modbus TCP
CONTROL INTER-
Ground Fault Protection GFDI and isolation monitoring device Power Plant Controller Optional
FACE
Humidity Control Active heating Keyed ON/OFF Switch Standard
PROTECTIONS General AC Protection & Disconn. Circuit breaker Ground Fault Protection GFDI and isolation monitoring device
General DC Protection & Disconn. Fuses, DC switch-disconnectors Humidity Control Active heating
Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2) PROTECTIONS General AC Protection & Disconn. Circuit breaker
Safety UL 1741 / CSA 22.2 No.107.1-16 / IEC 62109-1 / IEC 62109-2 General DC Protection & Disconn. Fuses, DC switch-disconnectors
CERTIFICATIONS
& STANDARDS
Installation NEC 2020 / IEC Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2)
Utility Interconnect IEEE 1547:2018 / UL 1741 SB / IEC 62116:2014 Safety UL 1741 / CSA 22.2 No.107.1-16 / IEC 62109-1 / IEC 62109-2
CERTIFICATIONS Installation NEC 2020 / IEC
& STANDARDS
Utility Interconnect IEEE 1547:2018 / UL 1741 SB / IEC 62116:2014
NOTES NOTES [1] Values at 1.00·Vac nom and cosφ=1. [3] Consult Power Electronics for derating curves.
[1] Values at 1.00·Vac nom and cosφ=1. [3] Consult Power Electronics for derating curves. Consult Power Electronics for derating curves. [4] Consult Power Electronics for Freemaq DC/DC connection
16
Consult Power Electronics for derating curves.
[2] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2).
[4] Consult Power Electronics for Freemaq DC/DC connection
configurations (available for Frame 4).
[2] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2). configurations (available for Frame 4).
17
POWER ELECTRONICS OUR PRODUCTS
HEMK HEMK
REFERENCES
AC Output Power (kVA/kW) @40°C [1]
FRAME 2
FS2055K
2055
FRAME 3
FS3080K
3080
645V FRAME 4
FS4105K
4105
REFERENCES
AC Output Power (kVA/kW) @40°C [1]
FRAME 2
FS2005K
2005
FRAME 3
FS3005K
3005
630V FRAME 4
FS4010K
4010
AC Output Power (kVA/kW) @50°C[1] 1905 2855 3810 AC Output Power (kVA/kW) @50°C[1] 1860 2790 3720
Max. AC Output Current (A) @40°C 1837 2756 3674 Max. AC Output Current (A) @40°C 1837 2756 3674
OUTPUT Operating Grid Voltage (VAC) 645V ±10% OUTPUT Operating Grid Voltage (VAC) 630V ±10%
Operating Grid Frequency (Hz) 50/60Hz Operating Grid Frequency (Hz) 50/60Hz
Current Harmonic Distortion (THDi) < 3% per IEEE519 Current Harmonic Distortion (THDi) < 3% per IEEE519
Power Factor (cosine phi)[2] 0.5 leading … 0.5 lagging adjustable / Reactive power injec- Power Factor (cosine phi)[2] 0.5 leading … 0.5 lagging adjustable / Reactive power injec-
tion at night tion at night
DC Voltage Range [3]
913V - 1500V DC Voltage Range [3]
891V - 1500V
Maximum DC Voltage 1500V Maximum DC Voltage 1500V
Number of Inputs Up to 40 Number of Inputs Up to 40
INPUT Max. DC Continuous Current (A)[4] 2295 3443 4590 INPUT Max. DC Continuous Current (A)[4] 2295 3443 4590
Max. DC Short Circuit Current (A)[4] 3470 5205 6940 Max. DC Short Circuit Current (A)[4] 3470 5205 6940
Number of MPPt (floating systems) 1 1 1, optionally 2 or 4 Number of MPPt (floating systems) 1 1 1, optionally 2 or 4
Number of Freemaq DC/DC [4] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced) Number of Freemaq DC/DC [4] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced)
Efficiency (Max) (η) 98.78% 98.81% 98.87% Efficiency (Max) (η) 98.76% 98.79% 98.85%
EFFICIENCY EFFICIENCY
Euroeta (η) 98.40% 98.43% 98.60% Euroeta (η) 98.39% 98.42% 98.59%
Dimensions [WxDxH] (ft) 9.8 x 6.6 x 7.2 Dimensions [WxDxH] (ft) 9.8 x 6.6 x 7.2
Dimensions [WxDxH] (m) 3.0 x 2.0 x 2.2 Dimensions [WxDxH] (m) 3.0 x 2.0 x 2.2
CABINET Weight (lbs) 11465 11795 12125 CABINET Weight (lbs) 11465 11795 12125
Weight (kg) 5200 5350 5500 Weight (kg) 5200 5350 5500
Type of Ventilation Forced air cooling Type of Ventilation Forced air cooling
Degree of Protection NEMA 3R / IP55 Degree of Protection NEMA 3R / IP55
Permissible Ambient Temperature -35°C to +60°C, >50°C / Active Power derating Permissible Ambient Temperature -35°C to +60°C, >50°C / Active Power derating
ENVIROMENT ENVIROMENT
Relative Humidity 4% to 100% non-condensing Relative Humidity 4% to 100% non-condensing
Max. Altitude (above sea level) 2000m / >2000m power derating (Max. 4000m) Max. Altitude (above sea level) 2000m / >2000m power derating (Max. 4000m)
Communication Protocol Modbus TCP Communication Protocol Modbus TCP
CONTROL INTER- CONTROL INTER-
Power Plant Controller Optional Power Plant Controller Optional
FACE FACE
Keyed ON/OFF Switch Standard Keyed ON/OFF Switch Standard
Ground Fault Protection GFDI and isolation monitoring device Ground Fault Protection GFDI and isolation monitoring device
Humidity Control Active heating Humidity Control Active heating
PROTECTIONS General AC Protection & Disconn. Circuit breaker PROTECTIONS General AC Protection & Disconn. Circuit breaker
General DC Protection & Disconn. Fuses, DC switch-disconnectors General DC Protection & Disconn. Fuses, DC switch-disconnectors
Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2) Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2)
Safety UL 1741 / CSA 22.2 No.107.1-16 / IEC 62109-1 / IEC 62109-2 Safety UL 1741 / CSA 22.2 No.107.1-16 / IEC 62109-1 / IEC 62109-2
CERTIFICATIONS CERTIFICATIONS
Installation NEC 2020 / IEC Installation NEC 2020 / IEC
& STANDARDS & STANDARDS
Utility Interconnect IEEE 1547:2018 / UL 1741 SB / IEC 62116:2014 Utility Interconnect IEEE 1547:2018 / UL 1741 SB / IEC 62116:2014
NOTES [1] Values at 1.00·Vac nom and cosφ=1. [3] Consult Power Electronics for derating curves. NOTES [1] Values at 1.00·Vac nom and cosφ=1. [3] Consult Power Electronics for derating curves.
Consult Power Electronics for derating curves. [4] Consult Power Electronics for Freemaq DC/DC connection Consult Power Electronics for derating curves. [4] Consult Power Electronics for Freemaq DC/DC connection
18 19
[2] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2). configurations (available for Frame 4). [2] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2). configurations (available for Frame 4).
POWER ELECTRONICS OUR PRODUCTS
HEMK HEMK
REFERENCES
AC Output Power (kVA/kW) @40°C [1]
FRAME 2
FS1955K
1955
FRAME 3
FS2935K
2935
615VFRAME 4
FS3915K
3915
REFERENCES
AC Output Power (kVA/kW) @40°C [1]
FRAME 2
FS1910K
1910
FRAME 3
FS2865K
2865
600V FRAME 4
FS3820K
3820
AC Output Power (kVA/kW) @50°C[1] 1815 2725 3635 AC Output Power (kVA/kW) @50°C[1] 1775 2660 3545
Max. AC Output Current (A) @40°C 1837 2756 3674 Max. AC Output Current (A) @40°C 1837 2756 3674
Operating Grid Voltage (VAC) 615V ±10% OUTPUT Operating Grid Voltage (VAC) 600V ±10%
OUTPUT
Operating Grid Frequency (Hz) 50/60Hz Operating Grid Frequency (Hz) 50/60Hz
Current Harmonic Distortion (THDi) < 3% per IEEE519 Current Harmonic Distortion (THDi) < 3% per IEEE519
0.5 leading … 0.5 lagging adjustable / Power Factor (cosine phi)[2] 0.5 leading … 0.5 lagging adjustable / Reactive power injec-
Power Factor (cosine phi)[2] tion at night
Reactive power injection at night
DC Voltage Range[3] 870V - 1500V DC Voltage Range [3]
849V - 1500V
Maximum DC Voltage 1500V Maximum DC Voltage 1500V
Number of Inputs Up to 40 Number of Inputs Up to 40
INPUT Max. DC Continuous Current (A)[4] 2295 3443 4590 INPUT Max. DC Continuous Current (A)[4] 2295 3443 4590
Max. DC Short Circuit Current (A)[4] 3470 5205 6940 Max. DC Short Circuit Current (A)[4] 3470 5205 6940
Number of MPPt (floating systems) 1 1 1, optionally 2 or 4 Number of MPPt (floating systems) 1 1 1, optionally 2 or 4
Number of Freemaq DC/DC [4] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced) Number of Freemaq DC/DC [4] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced)
Efficiency (Max) (η) 98.78% 98.81% 98.87% Efficiency (Max) (η) 98.76% 98.79% 98.85%
EFFICIENCY EFFICIENCY
Euroeta (η) 98.40% 98.43% 98.60% Euroeta (η) 98.39% 98.42% 98.59%
Dimensions [WxDxH] (ft) 9.8 x 6.6 x 7.2 Dimensions [WxDxH] (ft) 9.8 x 6.6 x 7.2
Dimensions [WxDxH] (m) 3.0 x 2.0 x 2.2 Dimensions [WxDxH] (m) 3.0 x 2.0 x 2.2
CABINET Weight (lbs) 11465 11795 12125 CABINET Weight (lbs) 11465 11795 12125
Weight (kg) 5200 5350 5500 Weight (kg) 5200 5350 5500
Type of Ventilation Forced air cooling Type of Ventilation Forced air cooling
Degree of Protection NEMA 3R / IP55 Degree of Protection NEMA 3R / IP55
Permissible Ambient Temperature -35°C to +60°C, >50°C / Active Power derating Permissible Ambient Temperature -35°C to +60°C, >50°C / Active Power derating
ENVIROMENT ENVIROMENT
Relative Humidity 4% to 100% non-condensing Relative Humidity 4% to 100% non-condensing
Max. Altitude (above sea level) 2000m / >2000m power derating (Max. 4000m) Max. Altitude (above sea level) 2000m / >2000m power derating (Max. 4000m)
Communication Protocol Modbus TCP Communication Protocol Modbus TCP
CONTROL INTER- CONTROL
Power Plant Controller Optional Power Plant Controller Optional
FACE INTERFACE
Keyed ON/OFF Switch Standard Keyed ON/OFF Switch Standard
Ground Fault Protection GFDI and isolation monitoring device Ground Fault Protection GFDI and isolation monitoring device
Humidity Control Active heating Humidity Control Active heating
PROTECTIONS General AC Protection & Disconn. Circuit breaker PROTECTIONS General AC Protection & Disconn. Circuit breaker
General DC Protection & Disconn. Fuses, DC switch-disconnectors General DC Protection & Disconn. Fuses, DC switch-disconnectors
Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2) Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2)
Safety UL 1741 / CSA 22.2 No.107.1-16 / IEC 62109-1 / IEC 62109-2 Safety UL 1741 / CSA 22.2 No.107.1-16 / IEC 62109-1 / IEC 62109-2
CERTIFICATIONS CERTIFICATIONS
Installation NEC 2020 / IEC Installation NEC 2020 / IEC
& STANDARDS & STANDARDS
Utility Interconnect IEEE 1547:2018 / UL 1741 SB / IEC 62116:2014 Utility Interconnect IEEE 1547:2018 / UL 1741 SB / IEC 62116:2014
NOTES [1] Values at 1.00·Vac nom and cosφ=1. [3] Consult Power Electronics for derating curves. NOTES [1] Values at 1.00·Vac nom and cosφ=1. [3] Consult Power Electronics for derating curves.
Consult Power Electronics for derating curves. [4] Consult Power Electronics for Freemaq DC/DC connection Consult Power Electronics for derating curves. [4] Consult Power Electronics for Freemaq DC/DC connection
20 21
[2] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2). configurations (available for Frame 4). [2] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2). configurations (available for Frame 4).
POWER ELECTRONICS OUR PRODUCTS
THE
AMERICAN
HEM
Page. 22 — 33
IDOL
22 23
POWER ELECTRONICS OUR PRODUCTS
These product
has the following
characteristics
HEM
The turn-key solution, simplifies the task
of designing the installation, and reduces
connection costs.
1 Easy maintenance
The advantages of a central inverter with
the modularity of the string inverters.
Bus Plus
2
Combine solar and storage.
The Bus Plus feature allows the connection of up
to four Freemaq DC/DC converters. It’s the most
3
cost-competitive solution for solar-plus-storage
retrofits.
ECON MODE
Remove no-load losses.
Disconnecting the power station from the grid
and taking the medium-voltage transformer out
of the circuit, eliminating the continuous energy
cost of no-load losses.
Advanced grid
support 4
Capable of operating on any power system,
Offering advanced grid support functionalities
to comply with the most restrictive grid codes.
24 25
POWER ELECTRONICS OUR PRODUCTS
5 iCOOL 3
The most innovative
cooling system.
Our own air ventilation system provides a constant
flow of clean air inside the equipment, without the
6
need of liquid cooling.
Active heating
When the unit is not actively exporting power, the
Patented inverter can import a small amount of power to keep
the inverter internal ambient temperature above -20°C,
without using external resistors.
7 Three-level
topology
The 3 level IGBT topology reduces stage losses,
increases inverter efficiency, and minimizes total
harmonic distortion. High efficiency to deliver
the lowest cost of energy (LCOE).
26 27
POWER ELECTRONICS OUR PRODUCTS
HEM
The ultimate
medium-voltage inverter
STRING INVERTER
CABINETS
1500 Vdc
Can reach up to a
4.2
nominal power of
DC-coupled
storage system
from 1200 kW to MVA
4800 kW
28 29
POWER ELECTRONICS OUR PRODUCTS
HEM HEM
REFERENCES FS4200M REFERENCES FS4105M
AC Output Power (kVA/kW) @40°C[1] 4200 AC Output Power (kVA/kW)@40°C[1] 4105
AC Output Power (kVA/kW) @50°C[1] 3900 AC Output Power (kVA/kW)@50°C[1] 3810
Operating Grid Voltage (kV)[2] 34.5kV ±10% Operating Grid Voltage (kV)[2] 34.5kV ±10%
OUTPUT Operating Grid Frequency (Hz) 60Hz OUTPUT Operating Grid Frequency (Hz) 60Hz
Current Harmonic Distortion (THDi) < 3% per IEEE519 Current Harmonic Distortion (THDi) < 3% per IEEE519
Power Factor (cosine phi)[3] 0.5 leading … 0.5 lagging adjustable / 0.5 leading … 0.5 lagging adjustable / Reactive power injec-
Reactive power injection at night Power Factor (cosine phi) [3]
tion at night
DC Voltage Range[4] 934V - 1500V DC Voltage Range[4] 913V - 1500V
Maximum DC Voltage 1500V Maximum DC Voltage 1500V
Number of Inputs Up to 40 Number of Inputs Up to 40
INPUT Max. DC Continuous Current (A)[5] 4590 INPUT Max. DC Continuous Current (A)[5] 4590
Max. DC Short Circuit Current (A)[5] 6940 Max. DC Short Circuit Current (A)[5] 6940
Number of MPPt (floating systems) 1, optionally 2 or 4 Number of MPPt (floating systems) 1, optionally 2 or 4
Number of Freemaq DC/DC[5] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced) Number of Freemaq DC/DC[5] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced)
Efficiency (Max) (η) 97.8% including MV transformer Efficiency (Max) (η) 97.76% including MV transformer
EFFICIENCY EFFICIENCY
Euroeta (η) 97.51% including MV transformer Euroeta (η) 97.50% including MV transformer
Dimensions [WxDxH] (ft) 21.3 x 6.5 x 7.2 Dimensions [WxDxH] (ft) 21.3 x 6.5 x 7.2
Dimensions [WxDxH] (m) 6.5 x 2.0 x 2.2 Dimensions [WxDxH] (m) 6.5 x 2.0 x 2.2
CABINET Weight (lbs) 30865 CABINET Weight (lbs) 30865
Weight (kg) 14000 Weight (kg) 14000
Type of Ventilation Forced air cooling Type of Ventilation Forced air cooling
Degree of Protection NEMA 3R Degree of Protection NEMA 3R
Permissible Ambient Temperature -35°C to +60°C, >50°C / Active power derating Permissible Ambient Temperature -35°C to +60°C, >50°C / Active power derating
ENVIROMENT ENVIROMENT
Relative Humidity 4% to 100% non-condensing Relative Humidity 4% to 100% non-condensing
Max. Altitude (above sea level)[6] 2000m Max. Altitude (above sea level) [6]
2000m
Communication Protocol Modbus TCP Communication Protocol Modbus TCP
CONTROL INTERFACE Power Plant Controller Optional CONTROL INTERFACE Power Plant Controller Optional
Keyed ON/OFF Switch Standard Keyed ON/OFF Switch Standard
Ground Fault Protection GFDI and isolation monitoring device Ground Fault Protection GFDI and isolation monitoring device
Humidity Control Active heating Humidity Control Active heating
PROTECTIONS General AC Protection & Disconn. MV switchgear (20 or 25 kA) General AC Protection & Disconn. MV switchgear (20 or 25 kA)
PROTECTIONS
General DC Protection & Disconn. Fuses, DC switch-disconnectors General DC Protection & Disconn. Fuses, DC switch-disconnectors
Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2 for DC Type 2 protection for AC and DC (optionally, Type 1+2 for DC
side) Overvoltage Protection side)
Safety UL 1741 / CSA 22.2 No.107.1-16 Safety UL 1741 / CSA 22.2 No.107.1-16
CERTIFICATIONS & CERTIFICATIONS &
Installation NEC 2020 Installation NEC 2020
STANDARDS STANDARDS
Utility Interconnect IEEE 1547:2018 / UL 1741 SB Utility Interconnect IEEE 1547:2018 / UL 1741 SB
NOTES [1] Values at 1.00·Vac nom and cosφ=1. [4] Consult Power Electronics for derating curves. NOTES [1] Values at 1.00·Vac nom and cosφ=1. [4] Consult Power Electronics for derating curves.
Consult Power Electronics for derating curves. [5] Consult Power Electronics for Freemaq DC/DC connection Consult Power Electronics for derating curves. [5] Consult Power Electronics for Freemaq DC/DC connection
HEM
REFERENCES FS4010M
AC Output Power (kVA/kW)@40°C[1] 4010
AC Output Power (kVA/kW)@50°C[1] 3720
Operating Grid Voltage (kV)[2] 34.5kV ±10%
OUTPUT Operating Grid Frequency (Hz) 60Hz
Current Harmonic Distortion (THDi) < 3% per IEEE519
Power Factor (cosine phi) [3] 0.5 leading … 0.5 lagging adjustable / Reactive power injec-
tion at night
DC Voltage Range[4] 891V - 1500V
Maximum DC Voltage 1500V
Number of Inputs Up to 40
INPUT Max. DC Continuous Current (A)[5] 4590
Max. DC Short Circuit Current (A)[5] 6940
Number of MPPt (floating systems) 1, optionally 2 or 4
Number of Freemaq DC/DC[5] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced)
Efficiency (Max) (η) 97.75% including MV transformer
EFFICIENCY
Euroeta (η) 97.48% including MV transformer
Dimensions [WxDxH] (ft) 21.3 x 6.5 x 7.2
Dimensions [WxDxH] (m) 6.5 x 2.0 x 2.2
CABINET Weight (lbs) 30865
Weight (kg) 14000
Type of Ventilation Forced air cooling
Degree of Protection NEMA 3R
Permissible Ambient Temperature -35°C to +60°C, >50°C / Active power derating
ENVIROMENT
Relative Humidity 4% to 100% non-condensing
Max. Altitude (above sea level)[6] 2000m
Communication Protocol Modbus TCP
CONTROL INTERFACE Power Plant Controller Optional
Keyed ON/OFF Switch Standard
Ground Fault Protection GFDI and isolation monitoring device
Humidity Control Active heating
General AC Protection & Disconn. MV switchgear (20 or 25 kA)
PROTECTIONS
General DC Protection & Disconn. Fuses, DC switch-disconnectors
Type 2 protection for AC and DC
Overvoltage Protection (optionally, Type 1+2 for DC side)
Safety UL 1741 / CSA 22.2 No.107.1-16
CERTIFICATIONS &
Installation NEC 2020
STANDARDS
Utility Interconnect IEEE 1547:2018 / UL 1741 SB
NOTES [1] Values at 1.00·Vac nom and cosφ=1. [4] Consult Power Electronics for derating curves.
Consult Power Electronics for derating curves. [5] Consult Power Electronics for Freemaq DC/DC connection
MEDIUM
MV SKID
VOLTAGE
Page. 38 — 39
STATIONS
Page. 40 — 41
TWIN SKID
34 35
POWER ELECTRONICS OUR PRODUCTS
Turn-key solution
MV Skid The SKID family facilitates the project design
and reduces the installation costs.
MV Simplify your
commissioning
STATIONS
All the medium voltage equipment is already integrated.
36 37
POWER ELECTRONICS OUR PRODUCTS
MV Skid
Compact
Easy to transport anywhere.
6.6 34.5
kV to
in the high voltage range
kV
600V - 690V
in the low
voltage range Choose the power
you need
Power outputs
from 1910 kVA
38 to 4390 kVA 39
POWER ELECTRONICS OUR PRODUCTS
Twin
Twin Skid
Compact
For largest solar plants.
Extra high power density.
6.6 34.5
kV to kV
in the high voltage range
600 V - 690 V
in the low
voltage range
Choose the distribution
that fits better on you
solar plant
Power outputs
from 3820 kVA
to 8780 kVA
40 41
POWER ELECTRONICS OUR PRODUCTS
NOTES NOTES [1] Consult with Power Electronics for other options.
[2] For lower temperatures, consult with Power Electronics.
Page. 46 — 47
PPC PRO
EMS
EVERYTHING
Page. 48 — 49
IN VIEW
ADVANCED
CONTROL
SOLUTIONS
44 45
POWER ELECTRONICS OUR PRODUCTS
PPC PRO
The Power Plant Controller is the interface The governor
between the grid operator and the
inverters, made to fulfill the requirements
of every grid. Regardless of where you are. Smart Q distribution
This algorithm allows to distribute the
reactive power between the inverters
depending on the available active power,
maximizing the energy production.
H
EM
K
G
EN
3
M
V
SK
PP
H
ID
EM
C
PR
CO
K
O
G
M
EN
PA
3
CT
M
V
SK
ID
CO
M
PA
CT
O&M diagnosis functions
Reports warning / fault messages
and enables user management...
46 47
POWER ELECTRONICS OUR PRODUCTS
24/7
Information
48 49
POWER ELECTRONICS OUR SECRET
We take care
of the legacy generations
Each new generation of inverters involves adapting the manufacturing lines to optimize
the production of these new devices. Power Electronics has a facility optimized for the
production of limited units from previous generations, where we manufacture current
BY POWER ELECTRONICS subcomponents adapted to equipment that is no longer in production, but which allows
for an extended life.
HEM
50 51
POWER ELECTRONICS
We are here to
WARRANTY
help you
Power Electronics (the Seller) warrants that their
Vertical
Products are free of faults and defects for a period of 3
years, valid from the date of delivery to the Buyer. It shall
be understood that a product is free of faults and defects
when its condition and performance is in compliance with
Integration
its specification.
Scan me! The warranty shall not extend to any Products whose
defects are due to (i) careless or improper use, (ii) failure
to observe the Seller’s instructions regarding the transport,
installation, functioning, maintenance and the storage of
throughout the entire process the Products, (iii) repairs or modifications made by the
Buyer or third party without prior written authorization of
We complement your spare parts strategy with our own thanks to our Dedicated Service the Seller, (iv) negligence during the implementation of
Factory warehouse, informing you when any of them is going to be discontinued so you authorized repairs or modifications, (v) if serial numbers are
can plan accordingly. modified or illegible, (vi) anomalies caused by, or connected
to, the elements coupled directly by the Buyer or by the final
customer, (vii) accidents or events that place the Product
outside its storage and operational specification, viii)
continued use of the Products after identification of a fault
or defect.
5
After commissioning
· Support 24/7, 365 days a year.
· Full warranty coverage with options for extension and
full preventative maintenance packages
· Advanced offerings for remote monitoring, detailed
performance reporting, and interactive portals for
tracking metrics direct with the PE Service Org
Power Electronics reserves the right to modify whole or part of the content of this
52 53
CONTACT
HEADQUARTERS
SPAIN UNITED STATES
Polígono Pla de Carrases 1510 N. Hobson Street, Gilbert
CV-35 Exit 30, 46160 Arizona, USA
Lliria - Valencia - Spain Tel. (+001) 602-354-4890
Tel. (+34) 96 136 65 57 sales@power-electronics.us
Fax (+34) 96 131 82 01 24/7 Technical Assistance Service
24/7 Technical Assistance Service Tel. (+001) 902 40 20 70
Tel. (+34) 902 40 20 70
INTERNATIONAL
ARGENTINA FRANCE PERU
Arroyo 894, 5º 51 Rue Hoche, 94200 Ivry Sur Seine. Avenida El Polo nº 670, Centro Comercial
Oficina 10 Ciudad autónoma de Paris (France) El Polo II – Oficina 603, Piso 6º, Bloque C
Buenos Aires +33(0)1 46 46 10 34 Santiago de Surco, Lima
ventesfrance@power-electronics.com (+51) 979 749 772
ASIA Contact: Guillaume Mamy ventasperu@power-electronics.com
30th Floor, CATIC Plaza, 8 Cau- Contact: Gustavo Prialé
seway Road, Hong Kong SAR INDIA
Silver Jade, Off. No 03, G.F., A-Wing CTS NO. GERMANY
AUSTRALIA -188, Behind Tarun Bharat Society, Chakala, Deieselstrasse, 77. D-90441.
U6, 30-34 Octal St. Yatala, Brisbane, Andheri East, Mumbai, Maharashtra Nürnberg. Germany
Queensland 4118, Australia (+91) 80 6569 0489 germany@power-electronics.com
(+61) 7 3386 1993 india@power-electronics.com
sales@power-electronics.com.au SOUTH AFRICA
Central Office Park Unit 5
ITALIA
BEIJING Piazzale Cadorna, 6, 20123.
257 Jean Avenue – Centurion 0157
Xiaoying Road Chaoyang, Nº25, southafrica@power-electronics.com
Milán Italia
Beijing City italy@power-electronics.com
UNITED KINGDOM
BRAZIL JAPAN Chippenham Drive, Unit 2, Madingley Court.
Nishi-Shinbasi 2-17-2 HF Toranomon Bldg 5F. Kingston, Milton Keynes.
Avda. Robert Kennedy 2070. Sao Bernardo do
105-0003 Minato-Ku Tokio MK10 0BZ, United Kingdom
Campo. Sao Paulo
japan@power-electronics.com uksales@power-electronics.com
(+55) 11 5891 9612 / (+55) 11 5891 9762
Contact: Stanley Han Contact (Solar division): Juan Antonio Torres
brasil@power-electronics.com
Contact: Fabio Cinquini
MALAYSIA PHILIPPINES
Unit 209 ZF Page 1 Bldg MBP
CHILE Level 7, Menara Milenium, Jalan Damanlela,
Pusat Bandar Damansara, Damansara Ayala Alabang, Muntinlupa.
Av. Alonso de Córdova 5870, Of. 210-211
Heigths, 50490 Kuala Lumpur W.P.
Las Condes, Santiago de Chile
(+56) 2 3223 8916
Malaysia REPÚBLICA DOMINICANA
malaysia@power-electronics.com Ave. John F. Kennedy Núm. 7, Los Jardines,
ventaschile@power-electronics.com
Distrito Nacional, República Dominicana.
COLOMBIA MEXICO
Henry Ford n.3, Fraccionamiento Industrial IRELAND
Cl 77 9-20 Bogotá DC 20 Harcourt Street Dublin,
San Nicolás, Tlalnepantla, Estado de México
Colombia D02 H364, Irlanda
(+52) 1 55 4949 0830 / (+52) 539 08818
(+57) 322 3464855
mexico@power-electronics.com
colombia@power-electronics.com
Contact: Manuel Garay
Contact: Héctor Nuñez
power-electronics.com