QSE-IO Control Interface Programming Guide

Contents

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
QSE-IO Operating Modes and DIP Switch Settings Overview . . . . 3
Equipment/Functionality Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Scene Selection Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . 6
Special Operating Mode: Sequencing . . . . . . . . . . . . . . . . . . . . . . 7
Special Operating Mode: Zone Lockout . . . . . . . . . . . . . . . . . . . . . 8
Special Operating Mode: Scene Lockout . . . . . . . . . . . . . . . . . . . . 9
Special Operating Mode: Panic . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Special Operating Mode: Timeclock . . . . . . . . . . . . . . . . . . . . . . . 11
Special Operating Mode: Afterhours . . . . . . . . . . . . . . . . . . . . . . 12
Shade Mode: Shade Input Preset . . . . . . . . . . . . . . . . . . . . . . . . 13
Shade Mode: Shade Input Raise, Lower, Stop . . . . . . . . . . . . . . . 15
Shade Mode: Shade Input Dual Group . . . . . . . . . . . . . . . . . . . . 16
Shade Mode: Shade Input Dual Group Raise/Lower . . . . . . . . . . 17
Shade Mode: Shade Input Toggle . . . . . . . . . . . . . . . . . . . . . . . . 18
Shade Mode: AC Shade Output . . . . . . . . . . . . . . . . . . . . . . . . . 19
Partitioning Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Occupancy Sensor Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Zone Toggle Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Zone Control Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Hotel Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Integration Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

page 1
3 4 5 6 7 8
QSE-IO Control Interface Programming Guide

3 4 5 6 7 8

Overview

These instructions detail the available functionsz o n e zone


Unit Overview hotel
and the accompanying necessary settings for t o g g l e control con guration
Program button
programming a QSE-IO control interface in 3a 4 5 6 7 8 3 4 5 6 7 8 3 4 5
DIP switches
6 7 8

Lutron system. For wiring, installation, system


setup, additional operation instructions, and3 other
4 5 6 7 8 3 4 5 6 7 8 3O 4 5 6 7 8
non-programming information, please refer to the 1234567
N 1 2 3 4 5 6 7 8

documentation that accompanied this and other


devices in your system. 3 4 5 6 7 8 3 4 5 6 7 8

Legend:
Up/On
Programming Your System 3 4 5 6 7 8 3 4 5 6 7 8
Down/Off
The programming instructions in this guide are for
standalone (GRAFIK Eye QS or QS link only)
systems. For Energi Savr Node or Quantum 3 4 5 6 7 8
Contact Closure Outputs
systems, refer to the documentation that came Contact
Closure Inputs

CCO 1 NO

CCO 2 NO

CCO 3 NO

CCO 4 NO

CCO 5 NO
CCO 1 NC

CCO 2 NC

CCO 3 NC

CCO 4 NC

CCO 5 NC
with those products for programming instructions.

1-2 COM

3-4 COM

5 COM
3 4 5 6 7 8

CCI 1
CCI 2
CCI 3
CCI 4
CCI 5
COM
QS Link
Switches and Connections
The DIP switches are numbered from 1 through 8.
For operating mode configuration, only switches
3 through 8 are used (with certain noted 4 3 2 1
exceptions; see the specific configuration
instructions).
The CCI and CCO wiring terminals each accept
one 28 to 16 AWG (0.08 to 1.5 mm2) wire. Refer to
the specific configuration instructions for details
on wiring for your desired operating mode.

Operating Modes
Each QSE-IO can be assigned only one (1)
operating mode from those detailed on the
following pages. By choosing the correct input
(CCI) terminal and accompanying DIP switch
settings, you can select the specific action each
operating mode will perform.

page 2
QSE-IO Control Interface Programming Guide

QSE-IO Operating Modes and DIP Switch Settings Overview


Mode Dip Switch Contact Closures Invoke:
Configuration 3 4 5 6 7 8 Input 1 Input 2 Input 3 Input 4 Input 5 Inputs Outputs
Scene 1 Scene 2s c e nScene
e 3 Scene 4 s p eOff
Scene cial and shade
selection special 2 stuffs
Scene 5 Scene3 64 Scene 78 Scene 8 Scene Off
5 6 7 3 4 5 6
Maintained
7 8
or 3 4 5 6 7 8
Maintained
Momentary
Scene 9 Scene 10 Scene 11 Scene 12 Scene Off
3 4 5 6 7 8 3 4 5 6 7 8
Scene 13 Scene3 144 5 6 7
Scene 8
15 Scene 16 Scene Off
Scene selection
Scene 1 Scene 2 Scene 3 Scene 4 Scene Off
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8

Scene 5 Scene 6 Scene 7 Scene 8 Scene Off


Maintained or Momentary
Momentary
Scene 9 Scene3 104 5
Scene
6 7
11
8
Scene 12 Scene
3 4
Off
5 6 7 8 3 4 5 6 7 8

Scene 13 Scene 14 Scene 15 Scene 16 Scene Off


Special Sequence Zone 3 4 5 Scene
6 7 8 Panic Timeclock Maintained
3 4 5 6 7 8

(maintained) 5–16 lockout lockout mode


Maintained
Special Sequence Zone Scene Panic Timeclock Momentary
(momentary) 5–16 lockout
3 4 5 lockout
6 7 8 mode 3 4 5 6 7 8

Special 2 Sequence Zone Scene Panic Afterhours Maintained


(maintained) 1–4 lockout lockout mode mode
Maintained
Special 2 Sequence Zone 3 4 5 Scene
6 7 8 Panic Afterhours Momentary 3 4 5 6 7 8
(momentary) 1–4 lockout lockout mode mode
Shade input preset
(“stop if moving”) Shade Shade3 4 Shade Shade Shade Maintained or
5 6 7 8 Maintained
3 4 5 6 7 8
Shade input preset open preset 1 preset 2 preset 3 close Momentary
(no “stop if moving”)
Shade input Shade Shade Shade Shade stop Shade Momentary or Maintained
3 4 5 6 7 8
(raise, lower, stop) open raise lower close Maintained
Shade input dual group
(“stop if moving”) Open Close Open Close Maintained or
— Maintained
3 4 5 6 7 8
Shade input dual group Group 1 Group 1 Group 2 Group 2 Momentary
(no “stop if moving”)
Shade input dual group Raise/Stop Lower/Stop Raise/Stop Lower/Stop — Momentary Momentary
(raise/lower) Group 1 Group 1 Group 2 Group 2 3 4 5 6 7 8

Shade input toggle Toggle Toggle Toggle Toggle Toggle


(“stop if moving”: Group 1 Group 2 Group 3 Group 4 Group 5 Momentary Momentary
open/stop/close/stop) 3 4 5 6 7 8

Shade input toggle Toggle Toggle Toggle Toggle Toggle


(no “stop if moving”: Group 1 Group 2 Group 3 Group 4 Group 5 Maintained Momentary
open/close) zone zone hotel
AC Shade output Open Stop Group
t o g gClose
le Open Close
c o n t r o lMaintained or con guration
Maintained
(maintained outputs) Group 1 1 Group 1 Group 2 Group 2 Momentary
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8
Stop Group Close Maintained
AC Shade output Open 1 Open Close Maintained or (except 2, which
(momentary stop) Group 1 if moving Group 1 Group 2 Group 2 Momentary is Momentary)
Stop
3 Group
4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8
AC Shade output Open Close Open Close Maintained or
1 Momentary
(momentary outputs) Group 1 Group 1 Group 2 Group 2 Momentary
if moving
Notes 3 4 5 6 7 8 3 4 5 6 7 8
• For AC shades with only 2 inputs (open/close), set DIP switch 1 to the up/on position to enable the feature Legend:
that mimics “stop” (asserts both “open” and “close” CCOs together when a “stop” command is received). Up/On
• The QSE-IO provides no power, only a control signal, to AC shades. Refer to the instructions that came with your shades
for more information. 3 4 5 6 7 8 3 4 5 6 7 8
Down/Off

3 4 5 6 7 8
page 3

3 4 5 6 7 8
selection special 2 stuffs
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7
QSE-IO Control Interface Programming Guide

3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7

QSE-IO Operating Modes and DIP Switch Settings Overview (continued)


Mode Dip Switch Contact Closures3 Invoke:
4 5 6 7 8
3 4 5 6 7 8 3 4 5 6 7
Configuration 3 4 5 6 7 8 Input 1 Input 2 Input 3 Input 4 Input 5 Inputs Outputs
Partitioning Wall 1 Wall 2 Wall 3 Wall 4 Wall 5 Momentary Maintained
(momentary) 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7
Partitioning Wall 1 Wall 2 Wall 3 Wall 4 Wall 5 Maintained Maintained
(maintained)
Occupancy sensor Generates
3 events
4 5 on
6 occupancy
7 8 and vacancy Maintained Maintained
3 4 5 6 7
(auto on/off)
Occupancy sensor Generates events on vacancy only Maintained Maintained
(manual on/auto off)
3 4 5 6 7 8 3 4 5 6 7
Zone toggle Toggle 1 Toggle 2 Toggle 3 Toggle 4 Toggle 5 Maintained
(maintained)
Zone toggle Toggle 1 Toggle
3 24 5 Toggle
6 7 83 Toggle 4 Toggle 5 Momentary
(momentary) 3 4 5 6 7
Maintained
Zone toggle with raise/lower
(maintained) Toggle 1 Toggle 2 Toggle 3 Raise Lower Maintained
3 4 5 6 7 8 3 4 5 6 7
Zone toggle with raise/lower Toggle 1 Toggle 2 Toggle 3 Raise Lower Momentary
(momentary)
Toggle 1 Toggle 2 Toggle 3 Toggle 4 Toggle 5 Maintained
Zone control 3 4 5 6 7

(maintained output) Maintained


Toggle 1 Toggle 2 Toggle 3 Toggle 4 Toggle 5 Momentary
3 4 5 6 7
Pulse 1 Pulse 2 Pulse 3 Pulse 4 Pulse 5 Maintained
Zone control
(momentary output) Momentary
Pulse 1 Pulse 2 Pulse 3 Pulse 4 Pulse 5 Momentary
3 4 5 6 7

Pulse 1 Pulse 2 Pulse 3 Pulse 4 Pulse 5 Maintained


Zone control
(pulsed output) Pulsed
Pulse 1 Pulse 2 Pulse 3 Pulse 4 Pulse 5 Momentary 3 4 5 6 7

1-3:
Service Privacy Start/end Toggle Maintained or Maintained
Hotel configuration 1 (make up (do notz o n eDoorbell afterhours Scene
z o n1/e Momentary h o3)t e l
(except
room) disturb) mode Off 4-5:
toggle c o n t r o lMaintained con gura
3 4 5 6 7 8 3 4 5 6 7
1-3:
8 3 4 5 6 7 8
Enable/
Service Privacy Start/end Maintained or
disable Maintained
Hotel configuration 2 (make up (do not Doorbell afterhours Momentary
Scene (except 3)
room) disturb) mode 4-5:
3lockout
3 4 5 6 7 8 4 5 6 7
Maintained
8 3 4 5 6 7 8

Control Control Control Control Control Maintained or Maintained or


Integration configuration output 1 output 2 output 3 output 4 output 5 Momentary Momentary
Notes 3 4 5 6 7 8 3 4 5 6 7 8

• Occupancy sensor: Each input represents 1 sensor/group of sensors. Response to sensor event is programmable at the Legend:
assigned lighting control. Up/On
• “Momentary” output pulse is of fixed duration (250 ms default). 3 4 5 6 7 8 3 4 5 6 7 8
“Pulsed” output duration corresponds to activating button being held/released. Down/Off
• Hotel: “Service” and “Privacy” are mutually exclusive; “Doorbell” is locked out when “Privacy” is active.
• DIP switch 1 must be up/on to activate the "Start/End Afterhours" feature on CCI4.
• DIP switch 2 must be up/on to activate the "Toggle Scene" or "Scene Blackout" feature on CCI 5. 3 4 5 6 7 8
• Occupancy sensors will not participate in partitioning logic.

3 4 5 6 7 8

page 4
QSE-IO Control Interface Programming Guide

Equipment/Functionality Table

Open/Close (stop if moving)


Look below for the Equipment/

Shade Input Dual Group


Shade Input Dual Group
Functionality you have/want,

Momentary Outputs

Momentary Outputs
Maintained Outputs

Maintained Outputs
Shade Input Toggle

Shade Input Toggle


Shade Input Preset

Occupancy Sensor
Raise, Lower, Stop

Momentary Stop
Scene Selection
then

Pulsed Outputs
Shade Output

Shade Output

Shade Output

Zone Control

Zone Control

Zone Control
Raise/Lower

Zone Toggle
Shade Input

Partitioning
Open/Close

Integration
Look to the right for the Operating Mode

Special
you need to refer to for the correct DIP

Hotel
switch setting and programming
instructions

Table applies only to standalone systems


See next page for notes

Contact Closure Maintained √ √ √ √ √ √ √ √ √ √ √ √ √


Inputs Momentary √ √ √ √ √ √ √ √ √ √ √ √ √ √ √
Maintained √ √ √ √ √ √ √ √ √ √ √ √
Contact Closure
Momentary √ √ √ √ √ √ √
Outputs
Pulsed √ √ √
Open/Close √ √ √ √ √
3 Presets √

Control Raise/Lower √ √
Sivoia QS Shades Stop if Moving √ √ √
via CCIs 1 Shade Group √ √
2 Shade Groups √ √
5 Shade Groups √ √
Control AC Shades from QS Shade Controllers
√ √ √
(wallstations) via CCOs
Scene Control via CCIs √ √
Scene Monitor via CCOs √
Zone Toggle via CCIs √ √ √ √
Zone Monitor via CCOs √
Control/Monitor
GRAFIK Eye QS Sequencing √
and/or Scene Lockout √ √
Energi Savr
Node QS Zone Lockout √
Panic √
Afterhours Start/Stop √ √
Timeclock Disable

(GRAFIK Eye QS only)
Implement Partition Logic for 5 Partition

Walls via CCIs
Receive Signals from up to 5 Groups of

Occupancy Sensors
Integrate a QS System into a Hotel Room √
Control RS232 or Ethernet and/or

Monitor CCIs/CCOs
Control CCOs from QS Input Devices
√ √ √ √ √ √ √
(e.g., wallstations)
Notes
• Table applies only to standalone systems (GRAFIK Eye QS or Energi Savr Node systems). For Quantum systems, refer to the instructions
that accompanied that equipment.
• A Momentary output pulse is of fixed duration (250 ms default).
• A Pulsed output pulse's duration corresponds to the activating button being held/released.
• Possible QS input devices include seeTouch QS wallstations, Pico wireless controls (via a QSM), QS keyswitch, QS IR Eye remote, another
QSE-IO control interface, or shade keypads on a GRAFIK Eye QS control unit.

page 5
QSE-IO Control Interface Programming Guide

scene spe
Scene Selection Operating Mode
Dip s e l eSettings
Switch ction Related Action spe
• Links to one or more GRAFIK Eye QS control
units and/or sEnergi
cene
Savr Node areas. special and 3s h a4d e 5 6 7 p a8 r t i t i Input
o n i 1:
n gScene 1 3 4
selection special 2 stuffs o c c s eInput n s o2:r Scene 2
• CCIs select between 4 scenes and Off. Input 3: Scene 3
• CCOs track3 currently
4 5 6 7 8
active scene.3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 Input
7 8 4: Scene 4

Input 5: Off
• Inputs: either momentary or maintained. Outputs: Maintained
• Outputs: all3 maintained
4 5 6 7 8
or all momentary
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8
(see chart). 3 4 5 6 7 8 Input 1: Scene 5 3 4
Input 2: Scene 6
• Communicates directly with GRAFIK Eye QS Input 3: Scene 7
control units
3 4and
5 6 Energi
7 8 Savr Node3 systems.
4 5 6 7 8 3 4 5 6 7 8 3 4 5 6
Input
7 8
4: Scene 8
Input 5: Off
Outputs: Maintained
Programming Instructions
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8

1. Enter programming mode on the QSE-IO control 3 4 5 6 7 8 Input 1: Scene 9 3 4


Input 2: Scene 10
interface: Press and hold the Program button for Input 3: Scene 11
3 seconds.3 LEDs
4 5 6 17 through
8 5 will cycle. 3 4 5 6 7 8 Input 4: Scene 12
2.To assign a GRAFIK Eye QS control unit to the Input 5: Off
Outputs: Maintained
QSE-IO, press and hold the Scene 1 button on
the GRAFIK3 Eye
4 5
QS
6 7
for
8
3 seconds. Repeat to 3 4 5 6 7 8
Input 1: Scene 13
3 4 5 6 7 8 3 4
assign additional GRAFIK Eye QS control units. Input 2: Scene 14
3. Exit programming mode on the QSE-IO control Input 3: Scene 15
3 4 5 6 7 8 3 4 5 6 7 8 Input 4: Scene 16
interface: Press and hold the Program button for Input 5: Off
3 seconds. Outputs: Maintained
For programming
3 4 5 6
instructions
7 8
for 3 4 5 6 7 8
Input 1: Scene 1
Energi Savr Node systems, see 3 4 5 6 7 8
Input 2: Scene 2
"Energi Savr Node Handheld Programming Input 3: Scene 3
3 4 5 6 7 8
Input 4: Scene 4
Guide" at www.lutron.com. Input 5: Off
Outputs: Momentary
3 4 5 6 7 8

3 4 5 6 7 8 Input 1: Scene 5
Input 2: Scene 6
Input 3: Scene 7
3 4 5 6 7 8
Input 4: Scene 8
Input 5: Off
Outputs: Momentary
3 4 5 6 7 8
Input 1: Scene 9
3 4 5 6 7 8
Input 2: Scene 10
Input 3: Scene 11
zone zone hotel i n t e g Input
r a t i4:o Scene
n 12
toggle control con guration c o n gInputu r a5:t Off
ion
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8
Outputs: Momentary

3 4 5 6 7 8 Input 1: Scene 13
Input 2: Scene 14
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6Input
7 3:8 Scene 15

Input 4: Scene 16
Input 5: Off
Outputs: Momentary
3 4 5 6 7 8 3 4 5 6 7 8

Legend:
Up/On
3 4 5 6 7 8 3 4 5 6 7 8
Down/Off

3 4 5 6 7 8

page 6
3 4 5 6 7 8
3 4 5 6 7 8 3 4 5 6 7 8

3 4 5 6 7 8
QSE-IO Control Interface Programming
3 4 5 6 7 8
Guide

scene special and sha


Special Operating Mode: Sequencing
selection
3 4 5 6 7 8

DipsSwitch
3
p e c Settings
4
i a l 2 Related Action
5 6 7 8
stu
• Links to one or more GRAFIK Eye QS control
33 Energi
4 45 6 57 8 6 7 8areas. 34 46 58 6 7 8 Maintained Inputs: 3 4 5
units and/or Savr Node 3 5 7
Input 1: closure enables, opening
• Moves sequentially through a group of scenes disables
(see chart) using Input 1. sequencing Scenes 5-16
3 4 5 6 7 8
Output: Maintained
• Inputs: momentary only or maintained only
(see chart)
- Maintained:
3 closure
4 5 enables
6 7 sequencing;
8 3 34 5 46 7 58 6 7 8 Momentary Inputs:
3 4 5
Input 1: button press toggles
opening disables sequencing. enable/disable sequencing
- Momentary: button press toggles between Scenes 5-16
enable and disable sequencing. 3 4 5 6 7 8 Output: Maintained
• Outputs: maintained.
• Communicates directly with GRAFIK Eye QS Maintained Inputs:
3 4 5 6 7 8 34 46 58 6 7 8 3 4 5
control units and Energi Savr Node systems. 3 5 7
Input 1: closure enables, opening
disables
sequencing Scenes 1-4
Programming
z o n eInstructions zone hotel i n t e g Output:
r a t i oMaintained
n
1. Enter toggle
programming mode on the c o n t r o lcontrol
QSE-IO con guration con guration
interface:3 Press
4 5 6
and
7 8
hold the Program
3 4 5
button
6 7 8
for 3 4 5 6 7 8
Momentary Inputs:
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5
3 seconds. LEDs 1 through 5 will cycle. Input 1: button press toggles
2.To assign a GRAFIK Eye QS control unit to the enable/disable sequencing
8 Scenes 1-4
QSE-IO, press and hold the Scene 1 button on
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7

Output: Maintained
the GRAFIK Eye QS control unit for 3 seconds.
Repeat to3 assign
4 5 6 7
additional
8
GRAFIK
3 4
Eye
5 6
QS
7 8

control units.
3 4 5 6 7 8 Legend: 3 4 5
3. Exit programming mode on the QSE-IO control Up/On
interface:3 Press
4 5 6 and
7 8 hold the Program
3 4 5 button
6 7 8 for
Down/Off
3 seconds.
For programming instructions for 3 4 5 6 7 8
Energi Savr 3 Node
4 systems,
5 6 7 see
8 3 4 5
"Energi Savr Node Handheld Programming
Guide" at www.lutron.com. 3 4 5 6 7 8

3 4 5 6 7 8 3 4 5

3 4 5 6 7 8 3 4 5

3 4 5

3 4 5
page 7
3 4 5 6 7 8 3 4 5 6 7 8

3 4 5 6 7 8
QSE-IO Control Interface Programming
3 4 5 6 7 8
Guide

scene special and sha


Special Operating Mode: Zone Lockout
selection
3 4 5 6 7 8

DipsSwitch
3
p e c Settings
4
i a l 2 Related Action
5 6 7 8
stu
• Links to one or more GRAFIK Eye QS control Maintained Inputs:
units and/or33 Energi
4 45 6 57 8 6
Savr 7
Node 8areas. 3 34 5 46 7 58 6 7 8 Input 2: closure enables, 3 4 5
• Prevents modifications to programmed preset opening disables zone lockout
Output: Maintained
light levels using Input 2. 3 4 5 6 7 8
• Inputs: momentary only or maintained only
(see chart)
- Maintained: Momentary Inputs:
3 closure
4 5 enables
6 7 lockout;
8 3 34 5 46 7 58 6 7 8 Input 2: button press toggles 3 4 5
opening disables lockout. enable/disable zone lockout
- Momentary: button presses toggle between Output: Maintained
enable and disable lockout. 3 4 5 6 7 8

• Outputs: maintained only.


• Communicates directly with GRAFIK Eye QS Maintained Inputs:
3 4 5 6 7 8 34 46 58 6 7 8 3 4 5
control units and Energi Savr Node systems. 3 5 7
Input 1: closure enables,
opening disables zone lockout
Output: Maintained
Programming
z o n eInstructions zone hotel integration
1. Enter toggle
programming mode on the c o n t r o lcontrol
QSE-IO con guration con guration
interface:3 Press
4 5 6
and
7 8
hold the Program
3 4 5
button
6 7 8
for 3 4 5 6 7 8
Momentary Inputs:
3 4 5 6 7 8 3 4 5 6 7 8 Input 1: button press toggles 3 4 5
3 seconds. LEDs 1 through 5 will cycle.
enable/disable zone lockout
2.To assign a GRAFIK Eye QS control unit to the
6Output:8 Maintained
QSE-IO, press and hold the Scene 1 button on
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 7

the GRAFIK Eye QS control unit for 3 seconds.


Repeat to3 assign
4 5 6 7
additional
8
GRAFIK
3 4
Eye
5 6
QS
7 8

control units.
3 4 5 6 7 8 Legend: 3 4 5
3. Exit programming mode on the QSE-IO control Up/On
interface:3 Press
4 5 6 and
7 8 hold the Program
3 4 5 button
6 7 8 for
Down/Off
3 seconds.
For programming instructions for 3 4 5 6 7 8
Energi Savr3 Node4 systems,
5 6 7 see
8 3 4 5
"Energi Savr Node Handheld Programming
Guide" at www.lutron.com. 3 4 5 6 7 8

3 4 5 6 7 8 3 4 5

3 4 5 6 7 8 3 4 5

3 4 5

3 4 5
page 8
3 4 5 6 7 8 3 4 5 6 7 8

3 4 5 6 7 8
QSE-IO Control Interface Programming
3 4 5 6 7 8
Guide

scene special and sha


Special Operating Mode: Scene Lockout
3
selection
4 5 6 7 8

DipsSwitch
3
p e c Settings
4
i a l 2 Related Action
5 6 7 8
stu
• Links to one or more GRAFIK Eye QS control units
33 4 Savr
45 6 57Node
8 6 7 8 34 46 58 6 7 8 Maintained Inputs: 3 4 5
and/or Energi areas. 3 5 7
Input 3: closure enables,
• Prevents selected scene or programmed preset opening disables scene lockout
levels from changing using Input 3. 3 4 5 6 7 8
Output: Maintained
• Inputs: momentary only or maintained only
(see chart)
- Maintained:
3 closure
4 5 enables
6 7 lockout;
8 3 34 5 46 7 58 6 7 8 Momentary Inputs:
3 4 5
Input 3: button press toggles
opening disables lockout. enable/disable scene lockout
- Momentary: button presses toggle between Output: Maintained
enable and disable lockout. 3 4 5 6 7 8

• Outputs: maintained.
• Communicates directly with GRAFIK Eye QS Maintained Inputs:
3 4 5 6 7 8 34 46 58 6 7 8 3 4 5
control units and Energi Savr Node systems. 3 5 7
Input 1: closure enables, opening
disables scene lockout
Output: Maintained
Programming
z o n eInstructions zone hotel integration
1. Enter toggle
programming mode on the c o n t r o lcontrol
QSE-IO con guration con guration
interface:3 Press
4 5 6
and
7 8
hold the Program
3 4 5
button
6 7 8
for 3 3 4 5 6 7 8
Momentary Inputs:
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5
seconds. LEDs 1 through 5 will cycle. Input 1: button press toggles
2.To assign a GRAFIK Eye QS control unit to the enable/disable scene lockout
6Output:8 Maintained
QSE-IO, press and hold the Scene 1 button on the
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 7

GRAFIK Eye QS control unit for 3 seconds. Repeat


to assign 3 additional
4 5 6 7 8
GRAFIK Eye QS
3 4
control
5 6 7 8
units.
3. Exit programming mode on the QSE-IO control
3 4 5 6 7 8 Legend: 3 4 5
interface: Press and hold the Program button for 3 Up/On
seconds.3 4 5 6 7 8 3 4 5 6 7 8
Down/Off
For programming instructions for
Energi Savr Node systems, see 3 4 5 6 7 8
"Energi Savr3 Node
4 5Handheld
6 7 Programming
8 Guide" 3 4 5
at www.lutron.com.
3 4 5 6 7 8

3 4 5 6 7 8 3 4 5

3 4 5 6 7 8 3 4 5

3 4 5

3 4 5
page 9
3 4 5 6 7 8 3 4 5 6 7 8

3 4 5 6 7 8
QSE-IO Control Interface Programming
3 4 5 6 7 8
Guide

scene special and sha


Special Operating Mode: Panic
selection
3 4 5 6 7 8

DipsSwitch
3
p e c Settings
4
i a l 2 Related Action
5 6 7 8
stu
• Links to one or more GRAFIK Eye QS control Maintained Inputs:
33 Energi
units and/or 4 45 6 57 8 6
Savr 7
Node 8areas. 3 34 5 46 7 58 6 7 8 Input 4: closure enables, 3 4 5
opening disables panic
• Activates Scene 16 and enables scene lockout Output: Maintained
using Input 4. 3 4 5 6 7 8
• Inputs: momentary only or maintained only
(see chart)
Momentary Inputs:
- Maintained:
3 closure
4 5 enables
6 7 panic;
8 3 34 5 46 7 58 6 7 8 Input 4: button press toggles 3 4 5
opening disables panic. enable/disable panic
- Momentary: button presses toggle between Output: Maintained
enable and disable panic. 3 4 5 6 7 8

• Outputs: maintained only.


• Communicates directly with GRAFIK Eye QS Maintained Inputs:
3 4 5 6 7 8 34 46 58 6 7 8 3 4 5
control units and Energi Savr Node systems. 3 5 7
Input 1: closure enables, opening
disables panic
Output: Maintained
Programming
z o n eInstructions zone hotel integration
1. Enter toggle
programming mode on the c o n t r o lcontrol
QSE-IO con guration con guration
interface:3 Press
4 5 6
and
7 8
hold the Program
3 4 5
button
6 7 8
for 3 4 5 6 7 8
Momentary Inputs:
3 4 5 6 7 8 3 4 5 6 7 8 Input 1: button press toggles 3 4 5
3 seconds. LEDs 1 through 5 will cycle.
enable/disable panic
2.To assign a GRAFIK Eye QS control unit to the
6Output:8 Maintained
QSE-IO, press and hold the Scene 1 button on
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 7

the GRAFIK Eye QS control unit for 3 seconds.


Repeat to3 assign
4 5 6 7
additional
8
GRAFIK
3 4
Eye
5 6
QS
7 8

control units.
3 4 5 6 7 8 Legend: 3 4 5
3. Exit programming mode on the QSE-IO control Up/On
interface:3 Press
4 5 6 and
7 8 hold the Program
3 4 5 button
6 7 8 for
Down/Off
3 seconds.
For programming instructions for 3 4 5 6 7 8
Energi Savr3 Node4 systems,
5 6 7 see
8 3 4 5
"Energi Savr Node Handheld Programming
Guide" at www.lutron.com. 3 4 5 6 7 8

3 4 5 6 7 8 3 4 5

3 4 5 6 7 8 3 4 5

3 4 5

3 4 5
page 10
QSE-IO Control Interface Programming
3 4 5 6 7 8 Guide
scene special and sha
Special Operating Mode: Timeclock
selection s p e c i a l 2 Related Action stu
3 4 5 6 7 8

Dip Switch Settings


• Links to one or more GRAFIK Eye QS control Maintained inputs
3 4 5 6 7 8 3
34 5
46 7
58 6 7 8 3 4 5
units. Input 5: contact closure
• On GRAFIK Eye QS control units only, disables disables timeclock;
contact opening
internal timeclock
z o n e using Input 5. zone hotel i n t e g r a t i o enables
n timeclock
• Inputs: momentary
t o g g l e only or maintained
c o n tonly
rol con guration c o n gOutput:
u r a tMaintained
ion
(see chart)3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8
Momentary inputs
- Maintained:
3 closure
4 5 disables
6 7 8timeclock; 3 4 5 6 7 8
Input 5: button press toggles
3 4 5
opening enables timeclock. disable/enable timeclock
- Momentary:
3 4 5
button
6 7 8
presses toggle
3 4
between
5 6 7 8 3 4 5 6 7 8 3 4 5 6Output:
7 8 Maintained

disable and enable timeclock.


• Outputs: maintained only.
• Communicates directly with GRAFIK Eye QS
3 4 5 6 7 8 3 4 5 6 7 8

3 4 5 6 7 8 Legend:
3 4 5 6 7 8 3 4 5
control units. Up/On
3 4 5 6 7 8 3 4 5 6 7 8
Down/Off
Programming Instructions
1. Enter programming mode on the 3QSE-IO
4 5 6 7
control
8
interface: Press
3 4 and
5 hold
6 the
7 Program
8 button for 3 4 5 6 7 8 3 4 5
3 seconds. LEDs 1 through 5 will cycle.
2.To assign a GRAFIK Eye QS control 3 4 unit
5 6 to
7 8 the

QSE-IO, press and hold the Scene 1 button on


the GRAFIK Eye QS control unit for 3 seconds.
Repeat to assign additional GRAFIK Eye QS
3
control units. 4 5 6 7 8 3 4 5
3. Exit programming mode on the QSE-IO control
interface: Press and hold the Program button for
3 seconds.
For programming instructions for
Energi Savr3 Node
4 systems,
5 6 7 see
8 3 4 5
"Energi Savr Node Handheld Programming
Guide" at www.lutron.com.

3 4 5 6 7 8 3 4 5

3 4 5 6 7 8 3 4 5

3 4 5

3 4 5
page 11
3 4 5 6 7 QSE-IO
8 Control Interface Programming
3
3 4 5 4 6 7 5 8 6 Guide
7 8 3 4 5

Special Operating Mode: Afterhours 3 4 5 6 7 8

Dip Switch Settings Related Action


• Links to one or more GRAFIK Eye QS control 34 46 58 6 7 8 Maintained Inputs:
3 4 5 6 7 8 3 5 7 3 4 5
units and/or Energi Savr Node areas. Input 5: button press toggles
• Enables afterhours mode using Input 5. enable/disable afterhours
Output: Maintained
• Inputs: momentary
zone only or maintained
z o n eonly hotel integration
(see chart) t o g g l e control con guration con guration
- Maintained:
3 4 5 closure
6 7 8 enables afterhours;
3 4 5 6 7 8 3 4 5 6 7 8
Momentary Inputs:
opening disables
3 4 5afterhours.
6 7 8 3 4 5 6 7 8
Input 5: closure enables,
3 4 5
- Momentary: button presses toggle between opening disables afterhours
enable and
3 4
disable
5 6 7 8
afterhours. 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6Output:
7 8 Maintained

• Outputs: maintained only.


• Communicates directly with GRAFIK Eye QS
control units
3 and 4 Energi 6 Savr
7 Node systems.
3 4 5 6 7 8 3 4 5 6 7 8

5 8 Legend: 3 4 5
Up/On
Programming Instructions
3 4 5 6 7 8 3 4 5 6 7 8
Down/Off
1. Enter programming mode on the QSE-IO control
interface: Press and hold the Program
3 4 5
button
6 7 8
for
3 seconds.3 LEDs
4 15 through
6 7 5 will
8 cycle. 3 4 5
2.To assign a GRAFIK Eye QS control unit to the
QSE-IO, press and hold the Scene 3 41 5button
6 7 8 on

the GRAFIK Eye QS control unit for 3 seconds.


Repeat to assign additional GRAFIK Eye QS
control units.
3 4 5 6
3. Exit programming mode on7 the8 QSE-IO control 3 4 5
interface: Press and hold the Program button for
3 seconds.
For programming instructions for
Energi Savr Node systems, see
3 Node
"Energi Savr 4 5Handheld
6 7 Programming
8 3 4 5
Guide" at www.lutron.com.

3 4 5

3 4 5

3 4 5

3 4 5
page 12
QSE-IO Control Interface Programming
3 4 5 6 7 8 Guide
special and shade partitio
Shade Mode: ss ppShade
ee cc ii aaInput
ll a2 Preset
nd s ht uafdf es po ca cr t istei on
Dip sSwitch
3 4 5 6 7 8

Settings Related Action


• Links to one orsmore
p e Sivoia
c i a QS l 2shades. stuffs Stop if moving:
occ sen
• Sends shades3 to4a specified
5 6 7preset
8 level, 3
34 5
46 7
58 6 7 8 3 4 5 6 7
Closure toggles action/stop
depending on3 input4 (see
5 6chart).
7 Can8 be set to 3 4 5 6 7 8 Input 1: Open/Stop3 shade4 5 6 7
stop shades if moving. Input 2: Shade to preset 1/Stop
3 4 5 6 7 8
Input 3: Shade to preset 2/Stop
• Inputs: momentary or maintained. Input 4: Shade to preset 3/Stop
• Outputs: maintained only. Input 5: Close/Stop shade
• Communicates
z3o n edirectly
4 5 with
6 Sivoia
7 8 zQS
o n eshades. h3o t e 4l 5 6 7 i8n t e g Outputs:
r a t i o nMaintained3 4 5 6 7
toggle control con guration con guration
3 4 5 6 7 8 3 4 5 6 7 8 No stop if moving:3 4 5 6 7
Programming Instructions
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8 Closure causes action
Input 1: Open shade
Assign shades before programming: Input 2: Shade to preset 1
Input 3:8 Shade to preset 2
1. Enter programming
3 4 5 6 7 8
mode on the 3QSE-IO
4 5 6 7
control
8 3 4 5 6 7 8 3 4 5 6 7
Input 4: Shade to preset 3
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7
interface: Press and hold the Program button for Input 5: Close shade
3 seconds. LEDs 3 4 1 and
5 56 will7 blink.
8 Make sure 3 4 5 6 7 8 Outputs: Maintained3 4 5 6 7
DIP switch 1 is down (Off).
3 4 5 6 7 8 3 4 5 6 7 8

Legend:
2. Shades that are currently assigned to the QSE-IO Up/On
will move3 to4 their
5 6 7close
8 limit, and shades
3 4 5 6
that
7 8
are
not assigned3will 4move 5 to6 their
7 open8 limit. 3 Down/Off
4 5 6 7 8 3 4 5 6 7
3. To select a shade, tap the Program button. The 3 4 5 6 7
3 4 5 6 7 8 3 4 5 6 7 8
selected shade will wiggle up and3 down. 4 5 6 To
7 8 To adjust these presets, follow these steps:
advance through all shades, tap the Program 1. Enter programming mode on the QSE-IO control
button. To go to the previous shade, double-tap interface: Press and hold the Program button for
the Program button. 3 4 5 6 7 8
33seconds.
4 5
LEDs
6 7
1 and
8
5 will blink. Make sure
4. When the desired shade is selected, press and DIP switch 1 is up (On) and DIP switches 2 and 3
hold the Program button for 3 seconds to assign are
3 down
4 5 (Off).
6 7 8
it (if unassigned) or unassign it (if assigned) to the 2. Preset 1 will be selected. To advance through the
QSE-IO. The 5 LEDs will blink for 2 seconds to presets, tap the Program button. To go to the
indicate success once you release the button. previous preset, double-tap the Program button.
5. When all shades you wish to be assigned are at LED
3 2,
4 3,5or 46 will7 light 8 to indicate which preset is
their close limit, and all shades you wish to be selected
3 4 5(1, 2,6 or 73). 8
unassigned are at their open limit, exit 3. When the desired preset is selected, press and
programming mode on the QSE-IO control hold the Program button for 2 seconds. All
interface: Press and hold the Program button for assigned QS shades will go to their assigned
10 seconds. value
3 4
for 5the selected
6 7 8
preset.
Program shades: 4. To select the shade you want to change, tap the
Program
3 4 5button
6 to 7 advance
8 through the assigned
Three presets are available on QS shades. Shade shades. The selected shade will wiggle up and
default presets are: down.
- Preset 1: all assigned shades 75% open 5. When the desired shade is wiggling, set DIP
- Preset 2: all assigned shades 50% open 3
switch4 2 up5 (On).
6 7The8shade will stop wiggling.
- Preset 3: all assigned shades 25% open 6. To
3 raise
4 the 5 selected
6 7 8QS shade to the desired
position for this preset, set DIP switch 3 up (On)
and use the Program button to adjust the QS
shade. To lower the shade, set DIP switch 3 down
(Off)
3 and
4 5use6the 7Program8 button to adjust.
3 4 5 6 7 8 (continued on next page)

3 4 5 6 7 8
page 13
3 4 5 6 7 8
QSE-IO Control Interface Programming Guide

Shade Mode: Shade Input Preset


(continued)

7. To move to another shade, set DIP switch 2 down


(Off). Repeat steps 4 through 6 until all shades are
set as desired for this preset.
8. With DIP switch 2 down (Off), press and hold the
Program button on the QSE-IO for 3 seconds to
save this preset. Return to step 2 to adjust
additional presets.
9. Exit programming mode on the QSE-IO control
interface: Press and hold the Program button for
10 seconds.
Note: At any point while DIP switch 2 is down
(Off), press and hold the Program button for 10
seconds to exit programming mode without
saving any presets.

Setting Limits
The open and close limits must be set on shades
to ensure they reach the desired levels when
those buttons are pushed, and to ensure they do
not go beyond those levels when being raised or
lowered.
Remote limit setting is not supported by the
QSE-IO control interface. To set limits before
programming, see the programming guide that
accompanied your shades. Or, if your system
contains a GRAFIK Eye QS control unit or
seeTouch QS wallstation, refer to the
programming instructions for one of those
devices.

page 14
3 4 5 6 7 QSE-IO
8 Control Interface Programming
3
3 4 5 4 6 7 58 6Guide
7 8 3 4 5 6 7

z o n e Shade Input
Shade Mode: zone hotel integration
toggle control con guration con guration
Raise, Lower, Stop Dip Switch Settings Related Action
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8

3 4 5 6 7 8 3 4 5 6 7 8 Input 1: Open shade3 4 5 6 7


• Links to one or more Sivoia QS shades. Input 2: Raise shade
Input 3: Lower shade
• Allows user
3 4 to
5 open,
6 7 8 close, raise, 3and
4 5 lower
6 7 8 3 4 5 6 7 8 3 4 5 6 7
Input 4:8 Stop shade
shades, depending on input (see chart). Input 5: Close shade
• Inputs: momentary or maintained. Outputs: Maintained
• Outputs: 3maintained.
4 5 6 7 8 3 4 5 6 7 8

3 directly
4 5 with
6 Sivoia
7 8 QS shades. Legend:
3 4 5 6 7 8 3 4 5 6 7
• Communicates Up/On
3 4 5 6 7 8 3 4 5 6 7 8
Down/Off
Programming Instructions
1. Enter programming mode on the 3QSE-IO 4 5 6 7
control
8

Setting
3 4 Limits
5 6 7 8
interface: Press and hold the Program button for
3 seconds. LEDs 1 and 5 will blink. Make sure The open and close limits must be set on shades
to ensure they reach the desired levels when
3 4 5 6 7 8
DIP switch 1 is down (Off).
2. Shades that are currently assigned to the QSE-IO those buttons are pushed, and to ensure they do
will move to their close limit, and shades that are not go beyond those levels when being raised or
not assigned will move to their open limit. lowered.
3 4 5 6 7 8
3. To select a shade, tap the Program button. The Remote limit setting is not supported by the
selected shade will wiggle up and down. To QSE-IO control interface. To set limits before
advance through all shades, tap the Program programming, see the programming guide that
button. To go to the previous shade, double-tap accompanied your shades. Or, if your system
the Program button. contains a5 GRAFIK Eye QS control unit or
3 4 6 7 8
4. When the desired shade is selected, press and seeTouch QS wallstation, refer to the
hold the Program button for 3 seconds to assign programming instructions for one of those
it (if unassigned) or unassign it (if assigned) to the devices.
QSE-IO. The 5 LEDs will blink for 2 seconds to
indicate success once you release the button.
5. When all shades you wish to be assigned are at 3 4 5 6 7 8
their close limit, and all shades you wish to be
unassigned are at their open limit, exit
programming mode on the QSE-IO control
interface: Press and hold the Program button for
10 seconds. 3 4 5 6 7 8

3 4 5 6 7 8

3 4 5 6 7 8

3 4 5 6 7 8
page 15
3 4 5 6 7 8
3 4 5 6 7 QSE-IO
8 Control Interface Programming
3 4 5 6Guide
7 8 3 4 5 6 7
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7
Shade Mode: Shade Input Dual Group
3 4 5 6 7 8

Dip Switch Settings Related Action


• Links to one or more Sivoia QS shades. 3 4 5 6 7 8
Stop if moving: 3 4 5 6 7
3 4 5 6 7 8 3 4 5 6 7 8
• Allows user to open or close shades, depending Closure toggles action/stop
on input (see3chart).
4 Can
5 6be set
7 to8 stop shades if 3 4 5 6 7 8 Input 1: Open/stop3Group41 shades
5 6 7
Input 2: Close/stop Group 1 shades
moving. 3 4 5 6 7 8
Input 3: Open/stop Group 2 shades
• Inputs: maintained or momentary. Input 4: Close/stop Group 2 shades
• Outputs: maintained
zone
only. zone hotel
Input 5: No function
i n t e g Outputs:
r a t i o nMaintained
• Communicatest o g gdirectly
le with Sivoia cQS
o n tshades.
rol
3 4 5
con guration
6 7 8
con guration
No stop if moving:
34 5 46 7 58 6 7 8
3 4 5 6 7 8 3 4 5 6 7 8 3 Closure causes action
Programming Instructions Input 1: Open Group 1 shades
Input 2: Close Group 1 shades
Group Selection Input 3:8 Open Group 2 shades
1. Make sure 3
DIP switch
4 5 6 7 8
1 is down (Off).
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7
Input 4: Close Group 2 shades
Enter programming mode on the QSE-IO control 3 4 5 6 7 8 Input 5: No function
interface:3 Press and hold the Program button for Outputs: Maintained
4 5 6 7 8 3 4 5 6 7 8
3 4 5 6 7 8
5 seconds. The LED(s) corresponding to Legend:
associated shade groups will blink rapidly. Up/On
2. To advance 3 4 through
5 6 7 8 all shade groups,
3 4 5 tap
6 7 the
8

Program button. To go to the previous shade Down/Off


3 4 5 6 7 8
group, double-tap the Program button.
3. When the desired shade group is3 selected,
4 5 6 7 8
set 3
Notes4 5 6 7 8
DIP switch 1 up (On) to "lock in" the selected • 2 groups are available for this mode: Group 1
group. The LEDs corresponding to the selected (CCI 1 and CCI 2), and Group 2 (CCI 3 and CCI
group will blink slowly.
3 4 5 6 7 8

4).3 4 5 6 7 8
Shade Selection • Preset Adjust Mode is not supported in this shade
4. Shades that are currently assigned to the selected 3 4 5 6 7 8
mode.
group will move to their close limit, and shades
that are not assigned will move to their open limit. Setting Limits
5. To advance through shades, tap the Program
button. To go to the previous shade, double-tap The
3 open
4 5 and6 close
7 limits
8 must be set on shades
the Program button. The selected shade will to3 ensure
4 5they6 reach
7 8the desired levels when
wiggle. those buttons are pushed, and to ensure they do
6. To assign the selected (wiggling) shade to a not go beyond those levels when being raised or
group, press and hold the Program button for 5 lowered.
seconds. The shade will close, indicating Remote
3 4 limit
5 setting
6 7 is8 not supported by the
assignment. To unassign an assigned shade, QSE-IO
3 4 control
5 6 interface.
7 8 To set limits before
select it (wiggle), then press and hold the Program programming, see the programming guide that
button for 5 seconds. The shade will open, accompanied your shades. Or, if your system
indicating it is no longer assigned. contains a GRAFIK Eye QS control unit or
Repeat for all shades you wish to assign to this seeTouch QS wallstation, refer to the
3 4 5 6 7 8
shade group. programming instructions for one of those
7. Repeat steps 1 through 6 for all remaining shade devices.
3 4 5 6 7 8
groups and shades you wish to assign to those
groups.
8. When all shades and shade groups are assigned,
exit programming mode on the QSE-IO control 3 4 5 6 7 8
interface: Press and hold the Program button for 3 4 5 6 7 8
10 seconds.

zone page 16
hotel integr
zc oo nn et r o l hc oo nt e lg u r a t i o n icnotne ggr
control con guration con g
3 4 5 6 7 8 3 4 5 6 7 8
3 4 5 6 7 8

QSE-IO Control Interface Programming


34 5 46 7 58 6Guide
7 8
3

Shade Mode:
zone
Shade Input Dual
zone
Group hotel integration
Raise/Lower
toggle control Dip
c o n Switch
g u r a t i oSettings
n c o n gRelated
u r a t i o n Action
3 4 5 6 7 8 3 4 5 6 7 8 3 4
3 5 6
4 7 8
5 6 7 8 Closure causes action;
• Links to one or more Sivoia QS shades. Opening stops action
Input 1: Raise/Stop Group 1 shades
• Toggles raise/stop or lower/stop for groups of Input 2: Lower/Stop Group 1 shades
shades, depending
3 4 5 6 7 8
on input (see 3chart).
4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8
Input 3: Raise/Stop Group 2 shades
• Inputs: momentary only. Input 4: Lower/Stop Group 2 shades
Input 5: No function
• Outputs: 3momentary
4 5 6 7 8
only. 3 4 5 6 7 8 Outputs: Momentary
• Communicates directly with Sivoia QS shades. 3
Legend:
4 5 6 7 8
Up/On
Programming Instructions
3 4 5 6 7 8 3 4 5 6 7 8
Down/Off
Group Selection
1. Make sure DIP switch 1 is down (Off).
3 4 5 6
Enter programming mode on the QSE-IO control
7 8
3 4 5 6 7 8
interface: Press and hold the Program button for Notes
5 seconds. The LED(s) corresponding 3 4 5 to
6 7 8
• 2 groups are available for this mode: Group 1
associated shade groups will blink rapidly. (CCI1 and CCI 2), and Group 2 (CCI3 and CCI 4).
2. To advance through all shade groups, tap the • Preset Adjust Mode is not supported in this shade
Program button. To go to the previous shade 3
mode.
4 5 6 7 8
group, double-tap the Program button.
3. When the desired shade group is selected, set
DIP switch 1 up (On) to "lock in" the selected
Setting Limits
group. The LEDs corresponding to the selected The open and close limits must be set on shades
group will blink slowly. to3 ensure
4 5they6 reach
7 the
8 desired levels when
Shade Selection those buttons are pushed, and to ensure they do
4. Shades that are currently assigned to the selected not go beyond those levels when being raised or
group will move to their close limit, and shades lowered.
that are not assigned will move to their open limit. Remote limit setting is not supported by the
5. To advance through shades, tap the Program QSE-IO control interface. To set limits before
3 4 5 6 7 8
button. To go to the previous shade, double-tap programming, see the programming guide that
the Program button. The selected shade will accompanied your shades. Or, if your system
wiggle. contains a GRAFIK Eye QS control unit or
6. To assign the selected (wiggling) shade to a seeTouch QS wallstation, refer to the
group, press and hold the Program button for 5 programming instructions for one of those
seconds. The shade will close, indicating devices.
3 4 5 6 7 8
assignment. To unassign an assigned shade,
select it (wiggle), then press and hold the Program
button for 5 seconds. The shade will open,
indicating it is no longer assigned.
zone
Repeat for all shades you wish to assign to this
shade group.
hotel integr
control
7. Repeat steps 1 through 6 for all remaining shade con guration con g
groups and shades you wish to assign to those
groups. 3 4 5 6 7 8 3 4 5 6 7 8
8. When all shades and shade groups are assigned,
exit programming mode on the QSE-IO control
interface: Press and hold the Program button for
10 seconds.

3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6

page 17
QSE-IO Control Interface Programming
3
3
4 5
4
6 7
5
8
6Guide
7 8

3 4 5 6 7 8
Shade Mode: Shade Input Toggle 3 4 5 6 7 8

Dip Switch Settings Related Action


• Links to one or more Sivoia QS shades. 3 4 5 6 7 8 Momentary inputs: Stop if moving:
• Inputs: momentary (stop if moving: 3 4 5 6 7 8 Closure toggles open/stop/close/stop
open/stop/close/stop) or Input 1: Toggle Group 1 shades
3 4 5 6 7 8 Input 2: Toggle Group 2 shades
maintained (no stop if moving: 3 4 5 6 7 8
Input 3: Toggle Group 3 shades
open/close). Input 4: Toggle Group 4 shades
• Outputs: momentary only (closure while assigned Input 5: Toggle Group 5 shades
zone zone h3o t e l4 i 8n t e g Outputs:
r a t i o nMomentary
shade or shades are moving). 5 6 7
toggle control con guration con guration
• Communicates directly with Sivoia QS shades. Maintained inputs: No stop if moving:
3 4 5 6 7 8 3 4 5 6 7 8 3 34 5 46 7 5
8 6 7 8 Opening closes shades
Programming Instructions Closure opens shades
Input 1: Toggle Group 1 shades
Group Selection
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6Input
7 2:8 Toggle Group 2 shades
3 4 5 6 7 8 Input 3: Toggle Group 3 shades
1. Make sure DIP switch 1 is down (Off). Input 4: Toggle Group 4 shades
Enter programming mode on the QSE-IO control 3 4 5 6 7 8 Input 5: Toggle Group 5 shades
interface: Press and hold the Program button for
3 4 5 6 7 8 3 4 5 6 7 8
Outputs: Momentary
Legend:
5 seconds. The LED(s) corresponding to Up/On
associated 3 4
shade
5 6 7
groups
8
will blink3 rapidly.
4 5 6 7 8

2. To advance through all shade groups, tap the 3 Down/Off


4 5 6 7 8
Program button. To go to the previous shade
group, double-tap the Program button. 3 4 5 6 7 8
3 4 5 6 7 8
3. When the desired shade group is selected, set
DIP switch 1 up (On) to "lock in" the selected Notes
group. The LEDs corresponding to 3 4
the
5
selected
6 7 8
• 53 groups
4 5are 6available
7 8 for this mode: Groups 1
group will blink slowly. through 5, corresponding to CCI1 through CCI 5.
Shade Selection • Preset
3 4 Adjust
5 6 Mode
7 is 8 not supported in this shade
4. Shades that are currently assigned to the selected mode.
group will move to their close limit, and shades
that are not assigned will move to their open limit. Setting Limits
3 4 5 6 7 8
5. To advance through shades, tap the Program
button. To go to the previous shade, double-tap The open and close limits must be set on shades
the Program button. The selected shade will to3 ensure
4 5 they
6 reach
7 8the desired levels when

wiggle. those buttons are pushed, and to ensure they do


6. To assign the selected (wiggling) shade to a not go beyond those levels when being raised or
lowered.
zone
group, press and hold the Program button for 5 hotel integr
seconds. The shade will close, indicating Remote limit setting is not supported by the
zc o n et r o l
assignment. To unassign an assigned shade, hc o nt e lg u r a t i o n
QSE-IO control interface. To set limits before icnotne ggr
select it (wiggle), then press and hold the Program programming, see the programming guide that
button for 53seconds.4
control
5 The
6 shade
7 8 will open, 4
con guration
3accompanied
5 6 your
7 8shades. Or, if your system
con g
indicating it is no longer assigned. contains a GRAFIK Eye QS control unit or
Repeat for all 3 shades
4 5 you
6 wish
7 to 8 assign to this 3seeTouch
4 5 QS 6 wallstation,
7 8 refer to the
shade group. programming instructions for one of those
7. Repeat steps 1 through 6 for all remaining shade devices.
groups and shades you wish to assign to those
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6
groups.
8. When all shades3 4
and 5
shade
6 7
groups
8
are assigned, 3 4 5 6 7 8 3 4 5 6
exit programming mode on the QSE-IO control
interface: Press and hold the Program button for
10 seconds.
. 3 4 5 6 7 8

3 4 5 6 7 8 page 18

3 4 5 6 7 8
3 4 5 6 7 8 3 4 5 6 7 8

QSE-IO Control Interface Programming Guide


3 4 5 6 7 8 3
334 5
446 7
558 66 77 88

Shade Mode: AC Shade Output


Dip Switch Settings Related Action
3 4 5 6 7 8

• Links to one or more of the following through the


Input 1: Open Group 1 shades
CCO connection on the QSE-IO interface: 3 34 5 46 7 58 6 7 8
Input 2: Stop Group 1 shades
- third-party AC shade or projection screen Input 3: Close Group 1 shades
groups Input 4: Open Group 2 shades
• Allows control of CCOs from QS devices, such as: 3 4 5 6 7 8 Input 5: Close Group 2 shades
Outputs: Maintained
- GRAFIK Eye QS shade column
- seeTouch QS shade wallstation Input 1: Open Group 1 shades
334 446 558 66 77 88 Input 2: Stop Group 1 shades
- Pico wireless control (through QSM)
3 5 7

Input 3: Close Group 1 shades


- QS keyswitch Input 4: Open Group 2 shades
- QS IR Eye zremote
one zone hotel i n t e g Input
r a t i5:o Close
n Group 2 shades
- another QSE-IO
t o g g l econtrol device c o n t r o l con guration c o n gOutputs:
u r a t iMoaintained
n
(Output 2 is Momentary)
- QSE-CI-NWK-E Ethernet and RS232 interface
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8
Input 1: Open Group 1 shades
See charts for specifics on DIP switch settings 3 4 5 6 7 8 Input 2: Stop Group 1 shades
and inputs/outputs that correspond to the signals Input 3: Close Group 1 shades
required by3 4 various
5 6 7 8 AC shades. 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6Input
7 4: 8 Open Group 2 shades
Input 5: Close Group 2 shades
• Inputs: maintained or momentary. Outputs: Momentary
• Outputs: 3see charts.
4 5 6 7
zone
8 3 4
• Communicates directly with devices listed above.
5 6 7 8
3h o t e5 l 6 7 8
4
Legend: integr
Special note: For AC shade controllers with only
2 inputs (open/close),
3 4 5 6 7
control
8 set DIP switch
3 4 1
5 to
6 7the
8
con guration
Up/On
con g
Down/Off
up/on position to enable the feature that mimics
"stop" (asserts3 both 4 5"open"
6 and
7 8"close" CCOs 3 4 5 6 7 8
zone
together when a "stop" command3 is4 received). 5 6 7 8
hotel integr
control
Programming Instructions 3 4 5 6 7 8
con guration con g
1. Enter programming
3 4
mode:
5 6
Press
7 8
and hold the 3
Note:
4
The
5
QSE-IO
6 7
provides
8
no power, only
3
a4 5 6
open and close buttons on a GRAFIK Eye QS control signal, to AC shades. Refer to the
shade column or seeTouch QS shade wallstation instructions that came with your shades for more
for 3 seconds. The LEDs on the QSE-IO control information.
device will turn off.
Note: For other supported device types, refer to
the instructions
3 4that5accompanied
6 7 8 each one. 3 4 5 6 7 8 3 4 5 6
2. On the QSE-IO you wish to obey commands from
that shade column or wallstation, tap the Program
button on the QSE-IO once to assign shade
Group 1 (LEDs 1 through 3 will blink), or twice to
assign shade 3 Group
4 5 2 (LEDs
6 7 4 and
8 5 will blink).
3. To unassign shade Group 1, tap the Program
button once when LEDs 1 through 3 are blinking;
the LEDs will stop blinking. To unassign shade
Group 2, double-tap the Program button once
when LEDs 34 and 4 55are 6blinking;
7 8 the LEDs will
stop blinking.
4. Exit programming mode: Press and hold the open
and close buttons on the shade column or
wallstation for 3 seconds.
3 4 5 6 7 8
page 19
3 4 5 6 7 8

QSE-IO Control Interface Programming Guide


l and shade 3
partitioning
4 5 6 7 8

l a nPartitioning
d Mode shade partitioning
l 2 stuffs oSwitch
c c Settings
sensor
l 2 stuffs Dip o
3
c c s e n s o rRelated Action
4 5 6 7 8

• Links to one or more GRAFIK Eye QS control Momentary Inputs:


7 8 units and/or Energi Savr 3 4
Node5 areas
6 7per 8I/O input. 3 4 5 6 7 8
Input 1: toggles partition 1 open/closed
7 8 3 4 5 6 7 8 34 46 58 6 7 8
• Allows multiple GRAFIK Eye QS control units and/ 3 5 7 Input 2: toggles partition 2 open/closed
Input 3: toggles partition 3 open/closed
or Energi Savr Node areas to operate either Input 4: toggles partition 4 open/closed
independently zone
(when the partition isz oclosed)
ne
or in hotel i n t e g Input
r a t i5:o tnoggles partition 5 open/closed
parallel (when t o gtheg l epartition is open).c o n t r o l con guration
Outputs: Maintained
con guration
7 8• Inputs: momentary only 3 or 4 maintained
5 6 7 only 8 3 4 5 6 7 8
7 8 (see chart)
3 4 5 6 7 8
3 4 5
3
6
4
7
5 6
8
7 8 3 4
3
5 6
4
7 8
5 6 7 8 Maintained Inputs:
Contact closure opens partition;
- Maintained: closure opens partition; opening closes partition
opening3 closes
4 5 6 7
partition.
8 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5
Input
6 7
1:8 opens/closes partition 1
Input 2: opens/closes partition 2
- Momentary: button presses toggle between Input 3: opens/closes partition 3
open and closed partition. 3 4 5 6 7 8 Input 4: opens/closes partition 4
7 8 3 4 5 6 7 8
7 8• Outputs: 3maintained
4 5 6 7 8 only.
3 4 5
3
6
4
7
5 6
8
7 8
3 4 5 6 7 8 Input 5: opens/closes partition 5
• Communicates directly with GRAFIK Eye QS Legend: Outputs: Maintained
control units, Energi Savr Node systems, and Up/On
GRX-IRPS 3
transmitter/receiver
4 5 6 7 8
pairs
3 4 5 6 7 8
Down/Off
(through CCIs).
7 8 3 4 5 6 7 8 3 4 5 6 7 8
7 8 3 4 5
3
6
4 5
7
6
8
7 8
3 4 5 6 7 8
Programming Instructions
1. Enter programming mode on the QSE-IO control
interface: Press and hold the Program button for
3 4 5 6 7 8

3 seconds. LED 1 will blink.


2. Wall 1 will be selected.3 To4 advance
5 6 through
7 8 the
3 4 5 6 7 8
assigned walls, tap the Program button. To go to
the previous wall, double-tap the Program button.
3. When the desired wall is selected, to assign the
GRAFIK Eye QS control unit to that wall, press
and hold the scene 13 button4 5on the
6 GRAFIK
7 8 Eye
QS control unit for 3 3seconds.
4 5 Repeat
6 7 to 8assign
additional GRAFIK Eye QS control units to that
wall; all control units assigned to that wall will work
together when that wall is open.
4. Exit programming mode on the QSE-IO control
3
interface: Press and hold 4the5Program
6 7 button
8 for
3 4 5 6 7 8
3 seconds.
Note: Occupancy sensors will not participate in
partitioning logic.
For programming instructions
3 4 5
for6 7 8
Energi Savr Node systems,
3 4 see
5 6 7 8
"Energi Savr Node Handheld Programming
Guide" at www.lutron.com.

3 4 5 6 7 8
3 4 5 6 7 8

3 4 5 6 7 8
3 4 5 6 7 8 page 20
3 4 5 6 7 8
QSE-IO Control Interface Programming Guide
7 8 3 4 5 6 7 8 3 4 5 6 7 8

Occupancy Sensor Mode 3 4 5 6 7 8

Dip Switch Settings Related Action


• Links to one or more GRAFIK Eye QS control units 3 4 5 6 7 8
Auto On–Auto Off:
7 8 per I/O input. 3 4 5 6 7 8 3 4 5 6 7 8 Contact closure: Initiates occupancy event
• Allows communication so that an occupancy Contact opening: Initiates vacancy event
sensor can turnz o n eon the assigned areas, z o n ewhile still hotel i n t e g Outputs:
r a t i o nMaintained
t o g g l e
allowing scene changes once the room c o n t is
rol con guration con guration
occupied.3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8

7 8
• 2 modes: Auto On–Auto 3 4
Off 5 6 7 8 3 4 5 6 7 8
Manual On–Auto Off:
Contact closure: No event
initiates events based on occupancy
6Contact
8 opening: Initiates vacancy event
and/or vacancy
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 7
Outputs: Maintained
Manual On–Auto Off
3
initiates
4 5 6 7
events
8
based on 3
vacancy
4 5 6 7 8

• Inputs: maintained only Legend:


• Outputs: maintained 3only.4 5 6 7 8 Up/On
• Communicates
3 4 5 6 directly
7 8 with GRAFIK 3 4 Eye
5 6 7QS
8
Down/Off
control units and wired occupancy sensors
(through CCIs)
3 4 5 6 7 8
Special note: Each input represents one sensor or
group of sensors. Response 3 4 5to the
6 sensor
7 8 event
(on occupancy and vacancy) is programmable 3 4 5 6 7 8 at
the assigned lighting control device.

Programming Instructions
3
Note: If multiple occupancy 4 sensors
5 6 7are 8
programmed to control the same space, the first Note: For more information and occupancy
sensor triggered will initiate the occupancy event, settings, see "GRAFIK Eye QS Control Unit
and all sensors must register vacancy to trigger Installation and Operation Guide" at
the vacancy event. www.lutron.com
3 4
1.Enter programming mode on5the 6GRAFIK
7 8
Eye QS Note: Occupancy sensors will not participate in
control unit. Press and hold the top and bottom partitioning logic.
scene buttons for 3 seconds. The main menu will
be displayed.
2.Navigate to and select occupancy sensor setup on
3 4 5 6 7 8
the GRAFIK Eye QS menu (Sensor Setup >
Occupancy > Setup). It will start searching for
sensors.
3.Scroll through the list of sensors until the desired
sensor is found. The screen will show the
3 4 5 6 7 8
QSE-IO's serial number at the top, and CCI
number (1-5) in the lower right corner.
4.Press the OK button and proceed to assign the
sensor.
5.Exit programming mode on the GRAFIK Eye
3 4 5 6 7 8
control unit. Press and hold the top and bottom
scene buttons for 3 seconds.

3 4 5 6 7 8 page 21
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8

QSE-IO Control Interface Programming Guide


3 4 5 6 7 8 3 4 5 6 7 8 3
zone
4 5 6 7 8 3 4 5 6 7 8
z
Zone Toggle Mode
3 4 5 6 7 8 3 4 5 6 7 8 3
tz oo gnSettings
Dip Switch
4 5
ge l e 6 7 8 3 4 5 6 Related
7 8 Action cz
• Links to one or more GRAFIK Eye QS control unit
zones and/or Energi Savr Node zones. 3 4 zt o5o gn6ge l7e 8 Maintained Inputs:
3 zc4
Closure turns zone on;
• Toggles between
3 4 5 6
Off
7 8
and a user-preset zone level. 3
t o5 g 6g l7e 8
4 5 6 7 8
opening turns zone off
c4
• Inputs: momentary only or maintained only, and
correspond3 to either 5 independently controlled
3 4
zone Input 1: toggle preset level 1/Off
Input 2: toggle preset level 2/Off
3
z
Input 3: toggle preset level 3/Off
3 4
t o5 g 6g l7e 8 3
c4
4 5 6 7 8 3 4 5 6 7 8
zones or groups of zones, or 3 independently Input 4: toggle preset level 4/Off
controlled zones or groups of zones plus zone 3 4 5 6 7 8
Input 5: toggle preset level 5/Off
3 4
Outputs: Maintained
raise and lower
3 4 5 (see
6 7 chart).
8 3
3 4 5
4 6 7
5 8
6 7 8 3 4
- Maintained: closure turns zones on to preset 3 4 5 6 7 8 Momentary Inputs:
3 4
level(s); opening turns zone(s) off. Closure toggles zone
Input 1: toggle preset level 1/Off
- Momentary: 3 4
closure
5 6 7 8
toggles zone(s) between 3
34 5
46 7
58 6 7 8 Input 2: toggle preset level 2/Off 3 4
preset level(s) and off; opening has no effect. Input 3: toggle preset level 3/Off
3 4 5 6 7 8 3 4
• Outputs: maintained. Input 4: toggle preset level 4/Off
3 4 5 6 7 8
Input 5: toggle preset level 5/Off
• Communicates directly with GRAFIK Eye QS 3 4 5 6 7 8
Outputs: Maintained
3 4
control units and Energi Savr Node systems. 3 4 5 6 7 8 3 4
3
3
4 5
4
6 7
5
8
6 7 8 Maintained Inputs: 3 4
Programming Instructions Closure turns zone on;
3 4 5 6 7 8 opening turns zone off 3 4
1. Enter programming mode on the QSE-IO control 3 4 5 6 7 8
Input 1: toggle preset level 1/Off
interface: Press and hold the Program button for 3 4 5 6 7 8 Input 2: toggle preset level 2/Off 3 4
3 4 5 6 7 8 Input 3: toggle preset level 3/Off 3 4
3 seconds. LED 1 will blink. Input 4: raise last zone toggled
2.Zone Toggle input 1 will be selected. To advance 3
34 5
46 7
58 6 7 8 Input 5: lower last zone toggled
3 4
through the inputs, tap the Program button. To go Outputs: Maintained
to the previous input, double-tap the Program 3 4
button. zone zone h3o t e l4 5 6 7 i8n t e g Momentary
r a t i o n Inputs:
3 4
t o g g l e
3.On the GRAFIK Eye QS control unit, c ouse
n t r othe
l raise con guration c o n gClosure
u r a ttoggles
i o n zone
Input 1: toggle preset level 1/Off 3 4
and lower3 buttons
4 5 6 7 for
8 the zone you
3 4want
5 6 to7 8assign 3 4 5 6 7 8
Input 2: toggle preset level 2/Off
to the selected input on the QSE-IO control Input 3: toggle preset level 3/Off 3 4
interface, and set the desired level. Then, press Input 4: raise last zone toggled
6Input
7 5:8 lower last zone toggled 3 4
and release
3 4
the
5 6
raise
7 8
and lower buttons
3 4 5 6
together
7 8 3 4 5 6 7 8 3 4 5
Outputs: Maintained
3 4
to assign that zone to the selected input on the
3 4
QSE-IO control
3 4 5 6
interface.
7 8
Repeat 3this
4 5
step
6 7
for
8
any
other zones that you wish to be toggled by the Legend: 3 4
selected input (on the same or any other GRAFIK Up/On
Eye QS control
3 4 5 6 units
7 8 in the system).
3 4 To5 unassign
6 7 8
Down/Off
assigned zones, press and release the raise and 3 4
lower buttons together.
4.Repeat steps 2 and 3 for each zone 3 4
toggle
5 6 7
input
8

on the QSE-IO control interface.


5.Exit programming mode on the QSE-IO 3 4 5 6
control
7 8
interface: Press and hold the Program button for
3 seconds.
For programming instructions for
Energi Savr Node systems, see
"Energi Savr Node Handheld Programming
Guide" at www.lutron.com.

page 22
33 44
3 4
QSE-IO Control Interface Programming Guide 3 4

zone zone 3
h o4 t e
Zone Control Mode
tz oo gn ge l e cz o n etSettings
Dip Switch rol Related Action
3c
h o4 nt e
3 4
• Allows seeTouch
controls3(vias4ac z
teQSM),
no eg
5o n6geQSl7ekeyswitches,
wallstations,
8
Pico wireless
special and
or other s
3 h ac
z d
4 o
e n5 et r
6 o 7l p a8r t i t i oMaintained
n i n g
Closure turns zone on; 3 c
h 4 n
o
Inputs, Maintained outputs: t5 e
selection special 2 stuffs o c c s e nopening
s o r turns zone off
QSE-IO control
3 can
• Optionally, 4 z
3
t additionally
4
odevices
5o g
5 n6ge l7toe toggle
6 7 8
CCOs.
8 to one or more
link 3 4 5 6 7 8 33 z c4 o n5 et r6 o 7l 8 Input 1: toggle preset level 1/Off3 hc4o nt5 e
4 5 6 7 8 3 4 5 6 7 8

zt oocontrol
n ge l unit zc oo nn et r o l Input 2: toggle preset level 2/Off h o t e

zt oo gn6ge l7ee 8
g
GRAFIK Eye QS zones and/or Energi Input 3: toggle preset level 3/Off c o n
3 4
Savr Node zones. 5 3 z4 o n 5 e6 7 8 3 h4o t5 e
• CCIs toggle
3 4

4between
5 6 7 8

6 Off7 and
3 4

8 a user-preset zone
5 6 7 8 3
c4
o n t
5
r o l6 7
Input 5: toggle preset level 5/Off c o n
Input 4: toggle preset level 4/Off
8 3 4 5 6 7 8

level. 3 4 t o 5 g 6g l 7e 8 3 c4 o n 5 tr 6 o 7l 8 3 c4o n
3 5 3 4 5 6 7 8 3
Outputs toggled by QS input devices 4 5
5
• Inputs: momentary Maintained Inputs, Momentary3output:4
33 3 444 5 556 7 only668 77or maintained
88 3 4 5 only,
6 7 8 and 3 334 5 446 7 558 66 773 4 885 6 7 8 3 4 55
Closure turns zone on;
correspond 3 4to 5 5 independently
6 7 8 controlled zones 3 4 5 6 7 8 opening turns zone off 3 4 5
or groups 3 of4 zones. 5 6 7 8 3 4 5 6 7 8 3
Input 1: toggle preset level 1/Off 4 5
- Maintained: 3 4
closure
5 6 7 8
turns zones3 on 4
to
5 6
preset
7 8 3 4 5 6 7 8 3 4 5 6 7Input
8 2: toggle preset level 2/Off

3 4 5 6 7 8 3 4 5 6 7 8 Input 3: toggle preset level 3/Off


level(s);3 opening
4 5 turns 6 zone(s)
7 8 off. 3 4 5 6 7 8 3
Input 4: toggle preset level 4/Off 4 5
- Momentary: closure toggles zone(s) between Input 5: toggle preset level 5/Off
33 3 444 5 556 7 668 77 88 334 446 558 66 77 88 3 4 5
preset3level(s) and off; opening has no effect.
3 5 7
Outputs pulsed by QS input devices
4 5 6 7 8 3 4 5 6 7 8 3 4 5
• Outputs:  Maintained Inputs, Pulsed output:
3 4 5 6 7 8 3 4 5 6 7 8
- Maintained 3 4 only
5 6 7 8 3 4 5 6 7 8
Closure turns zone on;
(button3 press4 on 5 input 6 7device
8 toggles output) opening turns zone off
3 4 5 6 7 8
3 4 5 6 7 8 3 4 5 6 7 8 Input 1: toggle preset level 1/Off
- Momentary only Input 2: toggle preset level 2/Off
(button33 press
44 5 on
3 4 556 7input
668 77device
88 triggers 3 334 5 446 7 558 66 77 88 Input 3: toggle preset level 3/Off
momentary3 4 pulse)5 6 7 8 3 4 5 6 7 8 Input 4: toggle preset level 4/Off
Input 5: toggle preset level 5/Off
- Pulsed3 only 4 5 6 7 8 3 4 5 6 7 8 Outputs pulsed by QS input devices
(CCO status 3 4 5
follows
6 7 8
activating button status, 3 4 5 6 7 8

3 4 5 6 7 8 Momentary input, Maintained output:


where 3if button
4 5 is released,
6 7 8 CCO is open, 3 4 5 6 7 8
Closure toggles zone
and if button
3 4 is5 pressed, 6 7 CCO8 is closed). 3
334 5
446 7
558 66 77 88 Input 1: toggle preset level 1/Off
• Communicates
3 4 5directly
6 with
7 8 seeTouch 3 4 5 6 7 8
Input 2: toggle preset level 2/Off
Input 3: toggle preset level 3/Off
wallstations, Pico wireless controls (via a QSM), 3 4 5 6 7 8 Input 4: toggle preset level 4/Off
QS keyswitches, or other QSE-IO control 3 4 5 6 7 8
Input 5: toggle preset level 5/Off
devices. 3
3
4
4
5
5
6
6
7
7
8
8
Outputs toggled by QS input devices
Special note: "Momentary" output pulse is of Momentary input, Momentary output:
3 334 5 446 7 558 66 77 88 Closure toggles zone
fixed duration (250 ms default). "Pulsed" output
3 4 5 6 7 8 Input 1: toggle preset level 1/Off
pulse duration corresponds to activating button Input 2: toggle preset level 2/Off
3 4 5 6 7 8
being held/released. 3 4 5 6 7 8 Input 3: toggle preset level 3/Off
Input 4: toggle preset level 4/Off
3 4 5 6 7 8 Input 5: toggle preset level 5/Off
Outputs pulsed by QS input devices
zone zone h3o t e l4 5 6 7 i 8n t e g r a t i o n
toggle control c 3o n 4g u r a5t i o n6 7 c8o n g Momentary
u r a t i o ninput, Pulsed output:
Closure toggles zone
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8
Input 1: toggle preset level 1/Off
Input 2: toggle preset level 2/Off
Input 3: toggle preset level 3/Off
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 Input
7 84: toggle preset level 4/Off
Input 5: toggle preset level 5/Off
Outputs pulsed by QS input devices
3 4 5 6 7 8 3 4 5 6 7 8

Legend:
Up/On
3 4 5 6 7 8 3 4 5 6 7 8
Down/Off
(continued on next page)
3 4 5 6 7 8

page 23
3 4 5 6 7 8
QSE-IO Control Interface Programming Guide

Zone Control Mode (continued)

Programming Buttons on QS Input Devices


to the CCOs
seeTouch QS Wallstation 3. To unassign an assigned CCO, select that CCO
Note: Wallstation must be set up for zone toggle as above, and press and hold the Program button
mode; see the instructions that accompanied your on the QSE-IO control device for 5 seconds.
wallstation for instructions. 4. Repeat steps 3 and 4 for any other CCOs you
wish to assign to this keyswitch.
1. Enter programming mode on the wallstation: Hold 5. Exit programming mode: Press and hold the
the top and bottom buttons for 5 seconds. Program button on the keyswitch for 5 seconds.
2. Press the button on the wallstation that you wish Replace the Faceplate adapter and faceplate on
to program. the keyswitch.
3. On the QSE-IO control device, tap the Program
button to advance through the CCOs (the LED for CCI on a Different QSE-IO Control Device
the selected CCO will blink rapidly). When you Note: On the control device to be programmed,
have reached the CCO that you wish to assign to the DIP switches must be in Zone Toggle
the selected button on the wallstation, press and configuration to toggle a CCO on a control device
hold the Program button on the QSE-IO control in Zone Control configuration. If correctly applied,
device for 5 seconds, then release. The LED will this programming mode can be used to translate
flash to confirm assignment. maintained signals into momentary, or vice versa.
4. To unassign an assigned CCO, select that CCO 1. Enter programming mode on the Zone Toggle
as above, and press and hold the Program button QSE-IO control interface: Press and hold the
on the QSE-IO control device for 5 seconds. Program button for 3 seconds. LED 1 will blink.
5. Repeat steps 3 and 4 for any other CCOs you 2. CCI1 will be selected. To advance through the
wish to assign to this wallstation button. inputs, tap the Program button. To go to the
6. Repeat steps 2 through 5 to program additional previous input, double-tap the Program button.
buttons on the wallstation. 3. On the Zone Control QSE-IO control interface, tap
7. Exit programming mode: Press and hold the top the Program button to advance through the
and bottom buttons on the wallstation for 5 CCOs (the LED for the selected CCO will blink
seconds. rapidly). When you have reached the CCO that
QS Keyswitch you wish to assign to the selected CCI, press and
Note: Keyswitch must be set up for zone toggle hold the Program button on the Zone Control
mode; see the instructions that accompanied your QSE-IO control device for 5 seconds. The LED
keyswitch for instructions. will flash to confirm assignment.
4. To unassign an assigned CCO, select that CCO
1. Enter programming mode on the keyswitch: press as above, and press and hold the Program button
and hold its Program button for 5 seconds. (You on the QSE-IO control device for 5 seconds.
must remove the faceplate and faceplate adapter 5. Repeat steps 3 and 4 for any other CCOs you
to access the Program button.) wish to assign to this CCI on the Zone Toggle
2. On the QSE-IO control device, tap the Program QSE-IO control interface.
button to advance through the CCOs (the LED for 6. Repeat steps 2 through 5 to program additional
the selected CCO will be blink rapidly). When you CCIs on the Zone Toggle QSE-IO control device.
have reached the CCO that you wish to assign to 7. Exit programming mode on the Zone Toggle
the selected button on the wallstation, press and QSE-IO control interface: Press and hold the
hold the Program button on the QSE-IO control Program button for 3 seconds.
device for 5 seconds. The LED will flash to
confirm assignment.
(continued on next page)

page 24
QSE-IO Control Interface Programming Guide

Zone Control Mode (continued)

Programming Instructions (continued)


Pico Wireless Control - State E: CCO2 Close
Note: Pico wireless control must already be LED2 alternates between flashing rapidly and
associated to a QSM and must have been set as On.
Zone type (this is the default type). Refer to the -S  tate F: CCO3 Open
QSM documentation for programming LED3 alternates between flashing rapidly and
instructions. A Pico control device programmed Off.
as a Zone type can be assigned to one or more -S  tate G: CCO3 Close
CCOs. All buttons on the Pico control device LED3 alternates between flashing rapidly and
affect the same CCO or group of CCOs. However, On.
any button on the Pico control device can be - State H: CCO4 Open
programmed to take any of its assigned CCOs to LED4 alternates between flashing rapidly and
any state (Open or Close). Off.
- State I: CCO4 Close
1. Enter programming mode on the Pico wireless LED4 alternates between flashing rapidly and
control: press and hold the top and bottom On.
buttons for 5 seconds. - State J: CCO5 Open
2. Press the button on the Pico wireless control that LED5 alternates between flashing rapidly and
you wish to program. (Raise/Lower buttons need Off.
not be programmed.) - State K: CCO5 Close
- CCOs on the QSE-IO control device that are LED5 alternates between flashing rapidly and
already programmed to Close when this button On.
is pushed will have their LEDs constantly on. 4. Press and hold the Program button on the
- CCOs on the QSE-IO control device that are QSE-IO control device for 5 seconds to complete
already programmed to Open when this button the assignment. The selected LED will blink
is pushed will have their LEDs flashing slowly rapidly to confirm the assignment.
(once per second). Note: If this is the first time you are assigning this
- CCOs that are not programmed to do anything combination of CCO and Pico wireless control,
when this button is pushed will have their LEDs the QSE-IO control device will automatically
constantly off. assign that CCO to all the other buttons on the
3. On the QSE-IO control device, tap the Program Pico wireless control (using default settings).
button to advance through the available states
that can be programmed to correspond to button 5. To unassign an assigned CCO, select that CCO
presses on the Pico wireless control. To go to the as above, and press and hold the Program button
previous state, double-tap the Program button. on the QSE-IO control device for 5 seconds. The
- State A (Initial state): No action. All LEDs are Off. selected LED will blink rapidly to confirm the
- State B: CCO1 Open unassignment. Note that the CCO will
LED1 alternates between flashing rapidly and automatically be unassigned from all buttons on
Off. the Pico wireless control.
- State C: CCO1 Close 6. Repeat steps 3 through 5 for any other CCOs you
LED1 alternates between flashing rapidly and wish to assign to the selected button.
On. 7. Repeat steps 2 through 6 for additional buttons.
- State D: CCO2 Open 8. Exit programming mode: Press and hold the top
LED2 alternates between flashing rapidly and and bottom buttons on the Pico wireless control.
Off.

(continued on next page)

page 25
QSE-IO Control Interface Programming Guide

Zone Control Mode (continued)

Programming Instructions (continued)


CCOs Follow GRAFIK Eye QS Zones CCIs Toggle GRAFIK Eye QS and
Each CCO can be set up to be controlled by a Energi Savr Node Zones
GRAFIK Eye QS zone. Note: On the control device to be programmed,
Note: To be assigned to a CCO, a GRAFIK Eye the DIP switches must be in Zone Toggle
QS control unit must first be set to the "Remote configuration. DIP switch 1 must be down (Off).
Non-Dim" load type. A GRAFIK Eye QS zone can 1. Enter programming mode on the QSE-IO control
be mapped to only one CCO. interface: Press and hold the Program button for
1. Enter programming mode on the GRAFIK Eye QS 3 seconds. LED 1 will blink.
control unit: Press and hold the top and bottom 2. CCI1 will be selected. To advance through the
scene buttons for 3 seconds. The LEDs in the inputs, tap the Program button. To go to the
scene buttons will scroll from top to bottom, and previous input, double-tap the Program button.
the info screen will display the main menu. 3.On the GRAFIK Eye QS control unit, use the raise
2. Use the Master buttons to the right of the screen and lower buttons for the zone you want to assign
to navigate to the "Remote Zone" menu, and to the selected input on the QSE-IO control
press the OK button. interface, and set the desired level. Then, press
3.On the GRAFIK Eye QS control unit, press the and release the raise and lower buttons together
raise or lower button for the zone you want to to assign that zone to the selected input on the
assign to the selected output on the QSE-IO QSE-IO control interface. Repeat this step for any
control interface. other zones that you wish to be toggled by the
4.On the QSE-IO control interface, repeatedly press selected input (on the same or any other GRAFIK
the Program button until the LED for the CCO you Eye QS control units in the system). To unassign
want to assign to with the zone is flashing. assigned zones, press and release the raise and
5. Press and hold the Program button on the lower buttons together.
QSE-IO control interface for 5 seconds to 4.Repeat steps 2 and 3 for each zone toggle input
complete the assignment. on the QSE-IO control interface.
6. To unassign a CCO, repeat steps 4 and 5 with an 5. Repeat steps 3 and 4 for any other zones you
assigned CCO. wish to assign to this CCI on the QSE-IO control
7. Repeat steps 3 through 6 to assign/unassign interface.
GRAFIK Eye QS zones to additional CCOs. 6. Repeat steps 2 through 5 to program additional
7. Exit programming mode on the GRAFIK Eye QS CCIs on the QSE-IO control device.
control unit: Press and hold the top and bottom 7. Exit programming mode on the QSE-IO control
scene buttons simultaneously for 3 seconds. The interface: Press and hold the Program button for
info screen will go to Scene 1. 3 seconds.
For programming instructions for
Energi Savr Node systems, see
"Energi Savr Node Handheld Programming
Guide" at www.lutron.com.

(continued on next page)

page 26
QSE-IO Control Interface Programming Guide

Zone Control Mode (continued)

Programming Instructions (continued)


CCIs Toggle CCOs on the same
QSE-IO Control Device
Note: On the control device to be programmed,
the DIP switches must be in Zone Toggle
configuration. DIP switch 1 must be up (On). If
correctly applied, this programming mode can be
used to translate momentary signals into
maintained, or vice versa.
If needed, it is possible to program the same
CCIs to GRAFIK Eye QS zones, Energi Savr Node
zones, and/or local CCOs on the same QSE-IO
control device.
1. Enter programming mode on the QSE-IO control
interface: Press and hold the Program button for
3 seconds. LED 1 will blink.
2. Toggle or pulse a CCI to select it. If no equipment
is connected to the CCI, this can be
accomplished by momentarily connecting a
jumper wire between that CCI and CCI
COMMON.
3. To advance through the CCOs, tap the Program
button. To go to the previous CCO, double-tap
the Program button.
4. Press and hold the Program button to assign the
selected CCO to the selected CCI.
5. Repeat steps 3 and 4 for any additional CCOs
you wish to assign to the selected CCI.
6. Repeat steps 2 through 5 to select additional
CCIs to complete your desired assignments.
7. Exit programming mode on the QSE-IO control
interface: Press and hold the Program button for
3 seconds.

page 27
33 44 55 66 77 88 33 44 55 66 77 88 33 44 55 66 77 88 33 44 55 66 77 88
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8

3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8
33 44 55 66 77 88 33 44 55 66 77 88 33 44 55 66 77 88 3 4 5 6 7 8
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8

QSE-IO Control Interface Programming


3 4 5 6 7 8
Guide
zone 3
33
3
4
44
4
5
55
5
6
66
6
7
77
7
hotel
8
88
8
3
33
3
integ 4
44
4
5
55
5
6
66
6
7
77
7
8
88
8
3
33
3
4
44
4
5
55
5
6
66
6
7
77
7
8
88
8
3
33
3
4
44
4
5
55
5
6
66
6
7
77
7
8
88
8

Hotel Mode
control c o n g u r a t i Related
o n Action c o n
3 4 5 6 7 8 3 4 5 6 7 8
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8
3 4 5 6 7 8 3 4 5 6 7 8

Dip Switch Settings


3 4 5 6 7 8

• Links to one or more GRAFIK Eye QS control units


3 4 5 6 7 8
33 44 55 66 77 88 33 44 55 66 77 88
3 4 5 6 7 8 3 4 5 6 7 8
3 4 5 6 7 8
Mode 1:
and/or Energi 3Savr4 Node 5 6
areas.7 8 3 4
3
33
5
4
44
5
55
6
66
6
7
77
7 8
8
88
Input 1: toggle output 1 3
33
4
44
5
55
6
66
7
77
8
88

• Accepts inputs from seeTouch QS wallstations, Input 2: toggle output 2


3 4 5 6 7 8 3 4 5 6 7 8

Input
r a t i3:o pulse n output 3
z o n e
Pico wireless control devices (through a QSM), z o n e h o t e l 3 4 5 6 7 i n
8 t e g
Input 4:t start/end
3 4 5 6 7 8

i o n Afterhours mode
3 4 5 6 7 8 3 4 5 6 7 8
3 4 5 6 7 8
t o g g l e c o n t r o l c o n g u r a t i o n c o n g u r a
3 4 5 6 7 8

QS keyswitches, or other QSE-IO control devices, Input 5: toggle Scene 1/Off


allowing the
3 4 mode
5 6 7 to8 toggle between3 4 5 Service
6 7 8 3 4 5 6 7
3
3 8
4
4
5
5
6
6
7
7
8
8
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8

(make up room) 3 and 4 Privacy


5 6 (do
7 not8 disturb), as 3 4 5 6 7 8 Mode 2: 3 4 5
Input 1: toggle output 1
well as to ring a doorbell.
3 4 5 6 7 8
3 4 5 6 7 8
3 4 5 6 7 8

Input 2:8 toggle output 2


• Allows interface
3 4 5 6
with
7 8
hotel room equipment.
3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7
Input 3: pulse output 3 3
3
4
4
5
5
6
6
7
7
8
8

Toggles outputs; Afterhours Mode; Scene 1 and


3 4 5 6 7 8

Input 4: start/end Afterhours mode


3 4 5 6 7 8

Input 5: enable/disable Scene Lockout


Off scene; 3
or
4 5
Scene
6 7 8
Lockout (see3 chart).
4 5 6 7 8
3
33
3
4
44
4
5
55
5
6
66
6
7
77
7
8
88
8

• Inputs: maintained3 4
(input
5
36 is momentary).
7 8 Legend: Standard Usage:
Output 1: Service (make up room)
• Outputs: maintained or momentary. zz oo nn ee Up/On zz oo nn ee hh oo tt ee ll ii nn tt ee gg rr aa tt ii oo nn 3
3
4
4
5
5
6
6
7
7
8
8

tt oo gg gg ll ee cc oo nn tt rr oo ll cc oo nn Outputgg uu rr aa tt2:
ii oo nnPrivacy (do
cc oo nnnotgg uudisturb)
rr aa tt ii oo nn
• Communicates
3 4 5 6 directly
7 8 with seeTouch
3 4 5 wallstations,
6 7 8 Output 3: Doorbell i n t e g r a t i o n
zz oo nn ee Down/Off zz oo nn ee
3 4 5 6 7 8
hh oo tt ee ll3 4 5 6 7 8 3 4 5 6 7 8

Pico wireless controls (via a QSM), QS integration


3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7 8

tt oo gg gg ll ee cc oo nn tt rr oo ll cc oo nn gg uu rr aa tt ii oo nn cc oo nn gg uu rr aa tt ii oo nn
Outputs 1 and 2 are mutually exclusive
keyswitches, or other QSE-IO control devices. 3
33
3
4
44
4
5
55
5
6
66
6
7
77
7
8
88
8 Output 2 active disables Output 3
3
33
3
4
44
4
5
55
5
6
66
6
7
77
7
8
88
8
3
33
3
4
44
4
5
55
5
6
66
6
7
77
7
8
88
8
3
3
4
4
5
5
6
6
7
7
8
8

• Inputs 4 (Start/End Afterhours) and 3 4


5 5(Scene
6 7 8
1/Off, Either Input 4 or Input 5 (not both) can be
or Scene Lockout) 3 4are5designed6 7 to8 be wired to a 3
33
3
4
44
4
5
55
5
6
66
6
7
77
7
8
88
8
3
33
3
4
44
4
5
active; the other must be disabled
55
5
6
66
6
7
77
7
8
88
8
3
3
4
4
5
5
6
6
7
7
8
8
3
3
4
4
5
5
6
6
7
7
8
8

hotel room keycard holder (input 43 recommended), 4 5 6 7 8


DIP switch 1 up (on): Input 4 activated
or third-party contact closure signals from the
3 4 5 6 7 8 3 4 5 6 7 8
33 44 55 66 77 88 33 44 55 66 77 88
3 4 5 6 7 8
DIP switch 1 down (off): Input 4 disabled
3 4 5 6 7 8

hotel reception desk at check-in and check-out DIP switch 2 up (on): Input 5 activated
3
3
4
4
5
5
6
6
7
7
8
8
DIP switch 2 down (off): Input 5 disabled
3
33
4
44
5
55
6
66
7
77
8
88

(input 5 recommended). When a GRAFIK Eye QS


3 4 5 6 7 8

control unit or 3Energi 4 Savr 5 6Node


7 area
8 is in
3
33
4
44
5
55
6
66
7
77
8
88

• Due to the mutually exclusive nature of the


3 4 5 6 7 8

Afterhours mode, the lights will turn off after a


programmable timeout (default is 5 minutes). If a Service, Privacy, and Doorbell CCOs, a given 3
3
4
4
5
5
6
6
7
7
8
8

button is pushed, turning the lights back on while button on the wallstation can be programmed to
in Afterhours mode, the lights will once again go only one of the three CCOs. However, multiple
off after a separate programmable timeout (default buttons may be programmed to the same CCO.
is 45 minutes).3 Before 4 5turning
6 off,
7 the8 lights flash to
1. Enter programming mode on the wallstation: Hold
warn any occupant in the space. When Afterhours the top and bottom buttons for 5 seconds.
mode is ended, this behavior stops and the lights 2. Press the button on the wallstation that you wish
return to their previous state. to program.
Special note: "Service" and "Privacy" will 3. On the QSE-IO control device, tap the Program
automatically mutually exclude each other. button to advance through CCOs 1, 2, and 3 (the
"Doorbell" is blocked when "Privacy" is active. LED for the selected CCO will blink rapidly). When
you have reached the CCO that you wish to assign
to the selected button on the wallstation, press and
Programming Instructions hold the Program button on the QSE-IO control
Programming Buttons on a seeTouch QS device for 5 seconds. The LED will flash to confirm
Wallstation to CCOs 1, 2 and 3 (Service, Privacy assignment.
and Doorbell) 4. To unassign an assigned CCO, select that CCO
Notes as above, and press and hold the Program button
on the QSE-IO control device for 5 seconds.
• Wallstation must be set up for zone toggle mode; 5. Repeat steps 2 through 4 to program additional
see the instructions that accompanied your buttons on the wallstation.
wallstation. 6. Exit programming mode: Press and hold the top
and bottom buttons on the wallstation for 5
seconds.

page 28
QSE-IO Control Interface Programming Guide

Hotel Mode (continued)

Programming Instructions (continued)


Programming Buttons on a Pico Wireless Control Programming CCIs 4 and 5 to a GRAFIK Eye QS
to CCOs 1, 2, and 3 (Service, Privacy and Control Unit or an Energi Savr Node Unit
Doorbell) 1. Enter programming mode on the QSE-IO control
Notes interface: Press and hold the Program button for
• The Pico wireless control must already be 3 seconds. LED 4 will blink.
associated to a QSM and must have been set as 2. Input 4 will be selected. To select between Input 4
Zone type (the default type). Refer to the QSM and Input 5, tap the Program button.
documentation for programming instructions. 3. When the desired input is selected, to assign the
• A Pico wireless control programmed as a Zone GRAFIK Eye QS control unit to that input, press
type can be assigned to either: and hold the Scene 1 button on the GRAFIK Eye
QS control unit for 3 seconds. Repeat to assign
- CCO1 (Service) and CCO2 (Privacy) together, additional GRAFIK Eye QS control units to that
where the top button of the Pico will command input.
"Service" and the bottom button will command 4. Press and hold the Program button on the
"Privacy" (2 button Pico wireless control QSE-IO control interface for 3 seconds to exit
recommended) programming mode.
- CCO3 (Doorbell), where the middle button of the Note: For programming instructions for
Pico wireless control will ring the doorbell (unless Energi Savr Node systems, see
the Privacy signal is asserted) "Energi Savr Node Handheld Programming
1. Enter programming mode on the Pico wireless Guide" at www.lutron.com.
control: Press and hold the top and bottom
buttons for 5 seconds.
2. On the QSE-IO control device, tap the Program
button to advance through CCOs 1, 2, and 3 (the
LED for the selected CCO will blink rapidly). When
you have reached the CCO that you wish to
assign to the Pico wireless control, press and
hold the Program button on the QSE-IO control
device for 5 seconds. The LED will flash to
confirm assignment.
3. To unassign an assigned CCO, select that CCO
as above, and press and hold the Program button
on the QSE-IO control device for 5 seconds. The
selected LED will blink rapidly to confirm the
unassignment.
4. Exit programming mode: Press and hold the top
and bottom buttons for 5 seconds.

page 29
con guration 3 4
con guration
5 6 7 8

8 3 4 5 6 QSE-IO
7 8 Control Interface Programming
3 4 5 6 7 8
Guide

Integrationz o Mode
ne zone hotel integration
toggle control Dip
c o n Switch
g u r a t i oSettings
n c o n gRelated
u r a t i o n Action
• Allows a QSE-CI-NWK-E
3 4 5 6 7 8
control device
3 4 5 6
to7 8 3 4 5 6 7 8 Input 1: notify QSE-CI-NWK-E
8 communicate with3 4 5
contact 6 7
closure 8
based 3 4 5 6 7 8
Input 2: notify QSE-CI-NWK-E
third-party equipment. Input 3: notify QSE-CI-NWK-E
Input 4:8 notify QSE-CI-NWK-E
• Inputs: m3omentary
4 5 6 7 8or maintained.3 4 5 6 7 8 3 4 5 6 7 8 3 4 5 6 7
Input 5: notify QSE-CI-NWK-E
• Outputs: momentary or maintained.
• Communicates directly with a QSE-CI-NWK-E
8 control device.
3 4 5 6 7 8 3 4 5 6 7 8

Legend:
Up/On
Programming Instructions
3 4 5 6 7 8 3 4 5 6 7 8
Down/Off
No programming is necessary. See the Lutron
Integration Protocol document (P/N 040249) at
8 www.lutron.com for supported commands.
3 4 5 6 7 8

3 4 5 6 7 8

page 30
QSE-IO Control Interface Programming Guide

Internet: www.lutron.com
E-mail: product@lutron.com
World Headquarters
USA
Lutron Electronics Co., Inc. Asian Headquarters
7200 Suter Road Singapore
Coopersburg, PA Lutron GL Ltd.
18036-1299 15 Hoe Chiang Road
TEL +1.610.282.3800 #07-03 Euro Asia Centre
FAX +1.610.282.1243 Singapore 089316
Customer Assistance: 1.844.LUTRON1 TEL +65.6220.4666
North and South America Technical Hotlines FAX +65.6220.4333
USA, Canada, Caribbean: 1.800.523.9466 Asia Technical Hotlines
Mexico: +1.888.235.2910 Northern China: 10.800.712.1536
Central/South America: +1.610.282.6701 Southern China: 10.800.120.1536
European Headquarters Hong Kong: 800.901.849
United Kingdom Indonesia: 001.803.011.3994
Lutron EA Ltd. Japan: +81.3.5575.8411
6 Sovereign Close Macau: 0800.401
London Singapore: 800.120.4491
E1W 3JF United Kingdom Taiwan: 00.801.137.737
Thailand: 001.800.120.665853
TEL +44.(0)20.7702.0657 Other countries: +65.6220.4666
FAX +44.(0)20.7480.6899
FREEPHONE (UK) 0800.282.107
Technical support +44.(0)20.7680.4481

)Lutron, Lutron, Sivoia, seeTouch, Pico, Quantum, and GRAFIK Eye are trademarks of Lutron
Electronics Co., Inc. registered in the U.S. and other countries.
Energi Savr Node is a trademark of Lutron Electron­ics Co., Inc.
© 2012-2016 Lutron Electronics Co., Inc.

R P/N 040391 Rev B 11/2016