ZT-CP3 Zeta Conventional Manual Call Point Range
This unique manual call point mimics the feel of breaking glass whilst offering the user the benefits and safety advantages of a
glass-free resettable operating element. Once activated a warning flag drops in to view easily identifying the call point that has
been operated .A key can the reset the unit. The call point provides an ideal solution for most conventional fire alarm systems.
It is ideal for industries that are sensitive to broken glass as well as areas that suffer from a high number of false activation s
such as; schools, shopping centres and other public places.
                                   ReSet Call Point Surface Mounting        Mou
                                                                                nti
                                                                                   ng
                                                                                        Wall Plate                 Methods of mounting
  Dia A.                           Back Box (Colour Matched)         Flu
                                                                         sh
                                   (Optional)
                                                                                                              Flush Installation
                                                  ting
                                              oun                                                             The call point is provided with a wall plate that is
                                       a c eM
                                     f                                                  Screw 3.5 x 3.5
                                 Sur                                                    (2) provided
                                                                                                              designed to fit directly onto a standard UK single
                                                                                        (Flush Models only)   35mm deep flush box.
                                                                                         Cover                Secure the wall plate to the flush mount box with
                                                                                                              the screws provided. Carefully attach the call
                                                                                                              point to the top of the wall plate and hinge down
                                                                                                              to snap securely into place.
                                    Screw No. 8 x 1.5                                   Operating             Surface Installation
                                         (2) provided                                   Element
                                (Surface Models only)                                                         NB: For security reasons the call point is
                                                                                                              deliberately difficult to remove from the back
                                                         ReSet Key (1)                                        box once fitted. Please ensure that the call
                                                             provided
                                                                                                              point is installed correctly before snapping
                                                                                                              closed.
                                                                                                              The call point can be supplied with its own
                                                                                                              surface mounting back box, 20mm entry holes
                                                                                                              can be easily cut using the template provided on
                                                          Dia C.                                              each pack box. (See illustration below).
                                                                                                              With the screws provided, fix the back box to the
                                                                                                              wall. Carefully attach the call point to the top of
                                                                                                              the back box, hinge down to snap securely into
                                                                                                              place.
                                                                                                                                       A
                                                                                                                            Dimensions
                                                                                                                             87 mm               23 mm
  Dia B.                                       Step 2
                                               Firmly push down on the cover to engage with
                                               clip. This should create a positive clicking
                                               sound which ensures that the clip has been
Step 1                                         correctly engaged (Dia C.)
Carefully attach the ReSet Call Point to the   NB: If unsure if the clip has engaged with the
top of the back box (Dia A.) and hinge down back box, *IMPORTANT* release the cover
to the points where the cover rests on the top following Step 3. When back in the position                        OPERATING ELEMENT COVER
of the clip (Dia B.)                           demonstrated in Dia B. repeat Step 2.
                                                                                                                 35 mm               87 mm
                         Dia D.
                                                2
                                                                                                                                                        87 mm
Step 3 - Detaching the cover from the 	
back box
1. Insert key into the bottom of the ReSet  1
   cover
2. Keep the key inserted and with your hand
   pull the cover towards you (Dia D.)                                                                                          BACK BOX
                                                            Option 1 Normally open switch
                                                             Option 1 terminals 1 and 4
                                                            closing on alarm
                                  ZT-CP3 Zeta Conventional Manual
                                                            Option 2 -Call     Point
                                                                         Normally  openRange
                                                                                         switch
                                                            ReSet Configuration
                                                            closing on alarm with a 1470 0hm       1
                                                                                   control panel
                                                            resistor fitted inseries with the switch
                                                                                            1  2
                                                            Option 3 - Normally470R1
                                                                                   open switch
                                                            closing on alarm with R2a 680 ohm
                                                            resistor inseries with  the switch
                                                                                  680       3  4
                                  Specifications                                                        Connection Options
                                                                                                                       4                  4
                                                      3 Amps 12 - 24V DC     Fire Panel Connection terminals 1 & 2
Current Rating
                                                      3 Amps 125 - 250V AC   Normally
                                                                               Option 1open    switch1 closing
                                                                                         terminals     and 4 on alarm with a 470
                                                                               Option
                                                                             ohm       2 terminals
                                                                                  resistor           1 and 2with the switch
                                                                                           fitted in series
Housing and Mounting Box Material                     Polycarbonate
                                                                                                                       1                  1
Electrical Contact Material                           Silver plated brass
                                                                                      +
                                                                               ReSet Configuration
                                                                                          panel
                                                                                                                       1                  1
                                                                                  controlpanel
Operating Temperature                                 -10°C to +55°C
                                                                                                                470
                                                                                                                                    470
                                                                                                                               1    2
Installation Terminal Conductor Size                  0.5mm to 2.5mm                                             R1
                                                                                 control
                                                                                                                470
                                                                                                                 R2
Humidity (no condensation)                            0 to 95%                                                  680 4          3    4     4
                                                                                                    -
Specifications are typical and given at 25°C          Relative humidity
                                                                                                                       2                   2
                    Terminal Configurations                                  Option 1 terminals 1 & 4
                                                                             Normally
                                                                              Option 21open
                                                                              Option         switch11closing
                                                                                        terminals
                                                                                         terminals    and 24 on alarm
                                                                                                     and
          1                 2                  Terminal configuration for     Option 3 terminals 1 and 3
                                               Product Codes:                               panel
                                                                                                                       1
                                                                                                                       1                  11
                                               ZT-CP3/F
                            470
                                                                                           panel
                                                                                                                           1               1
                                               ZT-CP3
                                                                                         panel
                                                                                                                 680
  680                                          ZT-CP3/B
                                                                                    control
                                                                                   control
                                               ZT-CP3/W
                                                                                 control
                                               ZT-CP3/Y
           3                4                                                                                          2
                                                                                                                       4
                                                                                                                                          2
                                                                                                                                          4
                                                                                                                           3               3
                                                                             Option 2 terminals 1 & 3
                    Terminal Configurations
                                                                             Normally open switch closing on alarm with a 680
                                                                             ohm resistor
                                                                               Option
                                                                              Option       fitted in 11
                                                                                      32 terminals
                                                                                         terminals    series
                                                                                                        and 32with the switch
                                                                                                        and
                                               Terminal configuration for
                                               Product Codes:
                                               ZT-CP3/G                                                                1
                                                                                                                       1                  1
                                                                                                                                          1
                                                                                          panel
                                                                                  control panel
                                                                                                                680
                                                                                                                680
                                                                                                                                    680
                                                                                  control
                                                                                                                       2
                                                                                                                       3                  2
                                                                                                                                          3
                                                                               Option 3 terminals 1 and 3
                                                                                                                       1                   1
                                                                                    control panel
                                                                                                                 680
                                            Zeta Alarms Limited                                                        3                   3
                         Detection House • 72-78 Morfa Road • Swansea • SA1 2EN
                    Telephone: +44 (0)1792 455 175 • Email: info@zetaalarmsystems.com
                                                                                                           IDRESET-RS2-ZT-CP3 - REVISED 03/17-014-PRINTED IN ENGLAND