0% found this document useful (0 votes)
145 views3 pages

Flexible Control Cables Guide

This document describes flexible control cables produced by Yair Duchovni Cables. The cables are constructed with stranded copper conductors insulated with FR PVC and a grey FR-PVC jacket. They are designed for power and control applications where flexibility is required, especially in wet or harsh indoor environments. The document provides details on the cable specifications, standards, electrical and mechanical properties, fire resistance, available models, and technical parameters.

Uploaded by

loko221
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
145 views3 pages

Flexible Control Cables Guide

This document describes flexible control cables produced by Yair Duchovni Cables. The cables are constructed with stranded copper conductors insulated with FR PVC and a grey FR-PVC jacket. They are designed for power and control applications where flexibility is required, especially in wet or harsh indoor environments. The document provides details on the cable specifications, standards, electrical and mechanical properties, fire resistance, available models, and technical parameters.

Uploaded by

loko221
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

www.yadu.co.

il DS Code: 1010

Flexible Control Cables - YSLY


Applications
 Power and control where cable flexibility is
required – indoor use, in chemically harsh and
wet environments
 Where EMC is not required

Standards
 DIN VDE 0245
 IEC 60227-1
 IEC 60332-1

Construction
Conductors Stranded copper conductors type 5 per IEC 60228
Insulation FR PVC Type D per IEC 60227-1
Color code 1 wire – yellow/green, all other – black, numbered. Two (2) wire cables
do not contain the yellow/green wire
Core layout In concentric layers
Jacket FR-PVC type ST5 per IEC 60227-1
Color: grey (RAL 7032)
Printing Control Cable YSLY-JZ, NxM, IEC 60332-1, VDE 0245, 300/500V RoHS,
Batch-code, Length in m (where N is the number of wires and M is the
wire cross-section area in mm2)

Electrical Properties (20°C)

Conductor resistance: 0.5 mm2  39 /km


0.75 mm2  26.4 /km
1.0 mm2  19.5 /km
1.5 mm2  13.3 /km
2.5 mm2  7.98 /km
4.0 mm2  4.95 /km
6.0 mm2  3.30 /km
10 mm2  1.91 /km
16 mm2  1.21 /km
Insulation dielectric strength: 3000 VDC / 1 minute
Insulation resistance 20 M/km
Voltage rating 300/500 V

Yair Duchovni Cables, POB 25008, 17 Hamashbir St. Haifa 3125001 Israel
Tel. +972-4-881-8400, Fax +972-4-881-8410
Website: www.yadu.co.il  E-Mail: info@yadu.co.il

Page 1 of 3 290813-A
www.yadu.co.il DS Code: 1010

Flexible Control Cables - YSLY


Current load 0.5 mm2 6A
0.75 mm2 13 A
1.0 mm2 16 A
1.5 mm2 20 A
2.5 mm2 25 A
4.0 mm2 35 A
6.0 mm2 40 A

Mechanical and Thermal Properties


Bending radius > 10 x cable diameter
Operation temperature range -5 to +70C

Fire Propagation Properties


 IEC 60332-1

Cable Codes and Technical Parameters


Nominal Nominal
Number of
Cable Code PN Diameter Weight
Pairs
(mm) (kg/km)
2 2x0.5-YSLY-OZ 2120218D 5.2 33
2 2x0.75-YSLY-OZ 2140203D 5.8 28
3 3x0.75-YSLY-JZ 2140306D 6.1 34
4 4x0.75-YSLY-JZ 2140401D 6.5 45
5 5x0.75-YSLY-JZ 2140502D 7.1 55
7 7x0.75-YSLY-JZ 2140701D 8.2 75
9 9x0.75-YSLY-JZ 2140901D 9.4 95
10 10x0.75-YSLY-JZ 2141001D 10.0 105
12 12x0.75-YSLY-JZ 2141205D 10.6 125
18 18x0.75-YSLY-JZ 2141801D 12.5 184
25 25x0.75-YSLY-JZ 2142501D 14.3 253
2 2x1.0-YSLY-OZ 2160201D 6.2 49
3 3x1.0-YSLY-JZ 2160301D 6.5 58
4 4x1.0-YSLY-JZ 2160401D 7.0 74
5 5x1.0-YSLY-JZ 2160501D 8.3 97
7 7x1.0-YSLY-JZ 2160701D 9.1 124
9 9x1.0-YSLY-JZ 2160901D 9.7 165
10 10x1.0-YSLY-JZ 2161003D 10.7 175
12 12x1.0-YSLY-JZ 2161201D 11.5 205
18 18x1.0-YSLY-JZ 2161801D 13.6 293
25 25x1.0-YSLY-JZ 2162501D 15.6 395

Yair Duchovni Cables, POB 25008, 17 Hamashbir St. Haifa 3125001 Israel
Tel. +972-4-881-8400, Fax +972-4-881-8410
Website: www.yadu.co.il  E-Mail: info@yadu.co.il

Page 2 of 3 290813-A
www.yadu.co.il DS Code: 1010

Flexible Control Cables - YSLY


Nominal Nominal
Number of
Cable Code PN Diameter Weight
Pairs
(mm) (kg/km)
2 2x1.5-YSLY-0Z 2180204D 6.8 62
3 3x1.5-YSLY-JZ 2180301D 7.0 74
4 4x1.5-YSLY-JZ 2180401D 7.7 98
5 5x1.5-YSLY-JZ 2180503D 9.0 124
7 7x1.5-YSLY-JZ 2180701D 9.8 161
9 9x1.5-YSLY-JZ 2160901D 11.1 205
10 10x1.5-YSLY-JZ 2161003D 11.6 227
12 12x1.5-YSLY-JZ 2161201D 12.5 267
18 18x1.5-YSLY-JZ 2181801D 14.9 387
25 25x1.5-YSLY-JZ 2182501D 17.2 528
3 3x2.5-YSLY-JZ 2220317D 9.1 120
4 4x2.5-YSLY-JZ 2220403D 9.6 155
5 5x2.5-YSLY-JZ 2220506D 11.5 204
7 7x2.5-YSLY-JZ 2220701D 12.4 260
3 3x4-YSLY-JZ 2260303D 10.3 168
4 4x4-YSLY-JZ 2260403D 11.2 224
5 5x4-YSLY-JZ 2260501D 13.3 288
6 6x4-YSLY-JZ 2260530D 15.0 350
3 3x6-YSLY-JZ 2280302D 12.5 235
5 5x6-YSLY-JZ 2280503D 15.5 410
5 5x10-YSLY-JZ 2300501D 20.0 710
5 5x16-YSLY-JZ 2320501D 31.0 1050

Yair Duchovni Cables Ltd. reserves the right to alter the products described in this data sheet without prior notice

Yair Duchovni Cables, POB 25008, 17 Hamashbir St. Haifa 3125001 Israel
Tel. +972-4-881-8400, Fax +972-4-881-8410
Website: www.yadu.co.il  E-Mail: info@yadu.co.il

Page 3 of 3 290813-A

You might also like