Z Z
10" 10"
AS PER ARCHTECTURAL DRAWING
RCC WALL(10" THK)
AS PER FOOTING
PCC
AS PER RAFT FOOTING
TYPICAL SECTION THROUGH LIFT
WALL(SECTION Z-Z)
GENERAL NOTES:- CONSULTANT:-
ONLY WRITTEN DIMENSION SHOULD BE FOLLOWED. DESIGN:-
THIS DRAWING SHOULD BE READ IN
CONJUCTION WITH RELEVANT ARCHITECTURAL APRO :-
DRAWINGS AND SITE CONDITIONS.
ANY DISCREPANCY IN THE DRAWING SHOULD BE BROUGHT
TO THE KNOWLEDGE OF CONSULTANT
BEFORE EXECUTION.
LOAD HAS BEEN TAKEN FOR (S+4) FLOORS ONLY.
PILE CAPACITY IS TAKEN AS 25 T.
CLEAR COVER TO MAIN REINFORCEMENT SHALL BE FOR
COLUMN - 40MM, PLINTH BEAM - 50MM, PILE-40mm,
PILE CAP-50mm, BEAM-25mm, SLAB - 20mm .
THE MIX FOR ALL R.C.C. WORK SHALL BE M-20 (1:1.5:3) .
ALL THE REINFORCEMENT SHALL BE Fe-500(HYSD BARS) .
MINIMUM DEVELOPMENT LENGTH FOR TOR STEEL SHALL
BE 50d, WHERE "d" IS DIA OF MAIN REINFORCEMENT.
THE LAP SHALL BE STAGGERED AND AVOIDED AT THE
POINT OF MAXIMUM BENDING MOMENT .