KT-LCD3
User Manual
eBike Special Meter
                                           English
Please read through carefully before use
PREFACE
    This manual aims to help the user understand and familiarise themselves with the
    meter function, operation of the meter, how to set the project parameters, how to
    achieve the best match of the three (motor, controller, and meter) to improve electronic
    control performance of the electric motor. This manual covers installation, operation,
    parameter setting of the meter and how to use it properly, which help user resolve
    issues that arise from use.
OUTLOOK AND SIZE
Meter Dimension
                                    Meter Dimension
                          Dual Bracket Mounting Dimension
2
Button Box Dimensions
Main Material and Colour
  The KT-LCD3 and button box are primarily constructed of polycarbonates (PC) and are
  of a dark gray or white colour.
Wiring Schematic
                                                                                        3
                                           Contents
Preface                                                2
Outlook and Size                                       2
Installation Instruction                               6
Function Overview                                      7
Display Content                                        7
Button Definition                                      8
Basic Operation                                        8
           On/Off                                      8
           Display Interface                           8
           Battery Capacity Indicator                  12
           PAS Ratio                                   12
           Power Push Function                         13
           Cruise Function                             13
           Backlight and Headlights                    13
           Motor Operating Power and Temperature       14
           Ambient Temperature                         14
           Single Data Clearing                        14
           Automatically Prompt Interface              15
User Setting Project                                   16
General Project Setting                                16
           Maximum Trip Speed                          16
           Wheel Diameter                              17
           Units                                       17
P Parameter Setting                                    18
           P1 Motor Characteristic Parameter Setting   18
           P2 Wheel Speed Pulse Signal Setting         18
           P3 Power Assist Control Setting             19
           P4 Throttle Start-Up Setting                19
4
         P5 Power Monitoring Setting                      20
C Parameter Setting                                       20
         C1 Throttle Start-Up Setting                     21
         C2 Motor Phase Classification Coding Mode        22
         C3 Power Assist Ratio Gear Initialization        22
         C4 Handlebar Function Setting                    23
         C5 Handlebar Function Setting                    23
         C6 Handlebar Function Setting                    24
         C7 Cruise Function Setting                       25
         C8 Motor Operating Temperature Display Setting   25
         C9 Startup Password Setting                      26
         C10 Restore Default Setting                      27
         C11 Meter Attribute Setting                      27
         C12 Controller Minimal Voltage Setting           28
         C13 ABS Brakes and Anti-Charge Control Setting   29
         C14 Power Assist Tuning Setting                  30
Parameter Copy                                            30
Version Information                                       31
Contact Us                                                32
                                                            5
INSTALLATION INSTRUCTION
    Using the appropriate methods and fixtures, mount the LCD screen and button box
    onto the handle bar to the rider’s desires. Refer to the following images below for
    installation on specific handle bar diameters. While the vehicle is off, connect the
    necessary wiring and check to make sure all connections are firmly attached. Finally,
    remove the protection film from the display.
                         Ø 31.8 Handlebar Diameter Install
                         Ø 22.2 Handlebar Diameter Install
                                   Installed KT-LCD3
6
FUNCTION OVERVIEW
   KT-LCD3 meter provides a variety of functions such as vehicle controls and vehicle
   status digitized displays to meet the trip demands.
◊	 Trip time display (with displays of a single trip time (TM) and total trip time (TTM));
◊	 Trip speed display (with displays of real-time speed (Km/H or MPH) and a single
   maximum speed (MXS) and a single average speed (AVS));
◊	 Trip distance display (with displays of a single trip distance (DST) and total trip distance
   (ODO));
◊	 Display of turned on handlebar;
◊	 Display of power-assist startup;
◊	 Power assistant ratio (or handlebar) gear (ASSIST) switch;
◊	 6Km/H power push (       ) function;
◊	 Cruise function (CRUISE);
◊	 Battery capacity indicator (           );
◊	 Real-time battery voltage (VOL) display;
◊	 Motor power and temperature (MOTOR) display;
◊	 Brake display (    );
◊	 Turn on backlighting and lights (       );
◊	 Environment temperature (°C or °F) display;
◊	 Data clearing;
◊	 Fault code display;
◊	 User parameter setting
◊	 24V, 36V, 48V supply voltage can automatic identification and be compatible
DISPLAY CONTENT
                                                                                                  7
BUTTON DEFINITION
    KT-LCD3 meter adopts the structural form with part design between the main part
    and operating buttons.
    There are three buttons on the operating panel of the box, which are icons of
    button (UP),      button (DOWN) and          button (POWER).
                           Button Box and Operating Panel
BASIC OPERATION
On/Off
    To turn on or off, hold down       button for 2 seconds. System will automatically shut
    down when vehicle is stationary and not in use for longer than five minutes. When
    powered off, the power consumption of the meter and controller is zero.
Display Interface
    Display 1: The meter is configured to enter this display on start-up.
    The following are shown on display 1.
          Battery Capacity Indicator                    Single Trip Time (TM)
8
      Power Assist           Real-Time Trip Speed (Km/H)
Single Trip Distance (DST)      6Km/H Push Function
Motor Operation Power         Environment Temperature
Backlight and Headlights             Brake Status
Cruise Function (CRUISE)     Motor Running Temperature
                                                           9
     Display 2: To enter display 2, press the        button whilst in display 1. The interface
     will display as shown below.
                                           Display 2
             Total Trip Time (TTM)                   Total Trip Distance (ODO)
         Single Average Speed (AVS)               Motor Operating Temperature
     Once the vehicle is in riding mode, after five seconds display 2 automatically reverts to
     display 1. The original motor power is replaced by the motor running temperature as
     shown below. To return to motor output, cycle through the displays back to display 1.
10
Display 3: To enter display 3, press the       button whilst in display 2. The interface
will display as shown below.
                                       Display 3
   Single Maximum Speed (MXS)                      Real-Time Voltage (VOL)
Once the vehicle is in riding mode, after five seconds the single maximum speed will
return to real-time speed (Km/H) as shown below.
To return to display 1, press      button.
Display of Powered Motor: When motor is powered, the LCD will display and animate
the following interface to indicate the motor is drawing power. This will only last a
duration of 5 seconds before reverting to display 1. The interface will appear as follows.
                                                                                             11
                                  Display of Powered Motor
     Display of Power-Assist: When motor is operating under power-assistance, the display
     interface flashes the “ASSIST” sign. The indicator will cease after 5 seconds.
                                   Display of Power-Assist
Battery Capacity Indicator
     The KT-LCD3 can identify 24V, 36V, 48V battery capacities when used with supporting
     controllers. When the battery capacity is over 70%, four bars from the battery indicator
     will be displayed. As the battery capacities drop, the bars will change accordingly. Once
     the power capacity is less than 15%, the battery indicator will be empty and show
     zero bars. If the power display frame flashes, it is due to voltage shortage where the
     controller will power off.
PAS Ratio
     Press       button or        button to adjust the power assist ratio, changing the motor
     output power. Range of power assist is between 1 and 5 (this can also be configured
     according to the rider’s requirements), where one provides the lowest power and five
     provides the highest. When the PAS ratio is set to zero, the power assist function is off.
12
Power Push Function
 Users can use power push function for assistance in vehicle take-off. Hold           button
 and the motor will provide power until vehicle reaches 6 Km/H. The meter assist
 function icon    will flash indicating the function is active. By releasing the     button,
 the function will be revoked.
Cruise Function
 When the vehicle is traveling above 7Km/H, hold           button for 3 seconds to set the
 cruise function. The LCD will display "CRUISE" and "C" to indicate that the cruise function
 has been activated (as seen in the figure below). Brake or hold any button to revoke
 cruise. Note that this feature only works if it has been activated through the parameter
 settings (check C7 in parameter setting).
Backlight and Headlights
 To turn on or off LCD backlight and vehicle headlights, hold         button for 3 seconds.
 When this function is activated, the display will show       sign to indicate it is on.
                                                                                               13
Motor Operating Power and Temperature
     Whilst vehicle is in use, real time feedback of input power to the motor is displayed on
     the meter. The operating temperature of the motor can be displayed with supporting
     sensors installed in the inner motor to output the temperature for signal detection.
     When the motor operating temperature exceeds the warning value, temperature
     display flashes to alarm the rider. In this circumstance, the motor controller will offer
     the appropriate protection to motor.
Ambient Temperature
     Upon start-up, the environment temperature is displayed on the bottom right hand
     corner. The displayed figure may not accurately indicate the environment temperature
     immediately after start up, however will adjust within 10 minutes.
Single Data Clearing
     After five seconds of start up, whilst on display 1 hold both the        button and the
     button        simultaneously for 3 seconds. The single trip time (TM) and single trip
     distance (DST) will flicker. Press      button and the record contents of both will be
     cleared. If there are no operations within five seconds of (TM) and (DST) flashing, the
     meter will return to display 1, and the original record content will be saved.
14
Automatically Prompt Interface
  Error Code Display: When there are issues with the electronic control system of the
  vehicle, the meter will automatically display (flicker) a fault code. This cannot be removed
  until fault is fixed. Refer to Error Code & Definition Table for reference.
  Motor operating temperature alarm: When the motor operating temperature
  exceeds the warning value, the motor operating temperature display flashes to alarm
  the rider, whilst the controller will provide the appropriate protection to the motor.
                                   Error Code Display
Error Code & Definition Table:
       Error Code                                       Definition
         01_info                                   Throttle Abnormality
         03_info                              Motor Hall Signal Abnormality
         04_info                            Torque Sensor Signal Abnormality
         05_info                             Axis Speed Sensor Abnormality
         06_info                           Motor or Controller Short Circuited
                                                                                                 15
USER SETTING PROJECT
     The KT-LCD3 meter provides users with 3 depths of settings which are s:
     •	General Project Setting
     •	P Parameter Setting
     •	C Parameter Setting
     To enter the general project setting, simultaneously hold      button and           button
     for 3 seconds within 5 seconds of turning the meter on. The current setting will be
     indicated by a flashing sign. To scroll through the menu, press the       button.
     Once the general project menu has been cycled through, the display will cease
     flashing. Now enter the P Parameter settings by simultaneously holding              button
     and        button for 3 seconds. The same method to scroll through the menu can be
     applied and the meter will flash specific icons indicating the setting currently open.
     Once the flashing has stopped, hold down both the            and         button again to
     progress to the C parameter settings. To exit these settings at any stage, simply hold
     down the         button where the meter will return to display 1. If no button operation
     occurs for 60 seconds whilst in a settings menu, the KT-LCD3 will discard changes and
     return to display 1. To exit at any moment, hold        and the meter will discard any
     unsaved changes and revert to display 1.
GENERAL PROJECT SETTING
Maximum Trip Speed
     Turn on meter, and within 5 seconds of start-up simultaneously hold                 button
     and	       button for 3 seconds to enter general project settings. “MXS” and the speed
     will be displayed, indicating the maximum riding speed (Refer to image below for
     illustration). To adjust, press the    button to increase or          button to decrease
     the speed. Once desired speed has been selected, press the            button to confirm
     changes and move onto wheel diameter.
16
Wheel Diameter
  While in the general project setting, cycle through the menu using the             button
  until the values of “DST” are flashing. Use the       button and         button to scroll
  through the selection of the following wheel diameters: 6, 8, 10, 12, 14, 16, 18, 20, 22,
  24, 26, 700C and 28 inches. Confirm selection by pressing the          button.
Units
  While in the general project setting, cycle through the menu using the         button until
  the values of units are flashing (as shown below). Use the       button and         button
  to scroll through the selection of units. Confirm selection by pressing the        button.
Definition Table of Metric/Imperial Units:
              Unit                           Metric                    Imperial
             Speed                           Km/H                          MPH
            Distance                          Km                           Mil
         Temperature                          °C                           °F
                                                                                                17
P PARAMETER SETTING
     Enter the P Parameter settings by cycling through the General Project Settings to the
     end (when display ceases flashing) and simultaneously holding       button and	
     button for 3 seconds. If required to exit at any parameter, hold         button for 2
     seconds. Use the      button and      button to select the value and confirm selection
     by pressing the      button. The parameter will be saved and the meter will enter the
     next P parameter settings.
P1 Motor Characteristic Parameter Setting
                                         P1 Display
     The P1 settings are a motor characteristic parameter where:
     			           P1 = Motor Gear Reduction Ratio × Number of Rotor Magnets
     Rounding to a full number is necessary. The P1 setting ranges between 1 and 255.
P2 Wheel Speed Pulse Signal Setting
     The P2 parameter setting will display on the meter after the P1 parameter setting has
     been selected and confirmed. The KT-LCD3 will display as follows:
                                         P2 Display
18
 The P2 parameter is a setting mode for wheel speed pulse signal. If wheel generated
 1 pulse signal by a revolution, the P2 value should be set to 1. If the wheel generated
 6 pulse signals by a revolution, P2 should be set as 6. If users did not configure the
 parameter then P2 can be set to 0. The selection of P2 values ranges from 0 to 6.
P3 Power Assist Control Setting
 The P3 parameter setting will display on the meter after the P2 parameter setting has
 been selected and confirmed. The KT-LCD3 will display as follows:
                                       P3 Display
 P3 parameters affect the power assist control setting. When the value is set to 0, the
 throttle is dependent on the PAS Gear Ratio. This means when the PAS gear ratio is 1,
 the throttle will provide the least amount of power, whereas when it is 5, the throttle
 will provide the most power. If the P3 parameter is set to 1, the throttle will provide the
 maximum power regardless on the PAS gear ratio chosen.
P4 Throttle Start-Up Setting
 The P4 parameter setting will display on the meter after the P3 parameter setting has
 been selected and confirmed. The KT-LCD3 will display as follows:
                                       P4 Display
                                                                                               19
     The P4 settings is for controlling the throttle activation. When the P4 parameter is 1,
     the throttle is under "non-zero startup"where the throttle will only activate the motor
     after the motor has been activated via pedaling. Setting the P4 to 0 will set the throttle
     to activate the motor when triggered.
P5 Power Monitoring Setting
     The P5 parameter setting will display on the meter after the P4 parameter setting has
     been selected and confirmed. The KT-LCD3 will display as follows:
                                           P5 Display
     The P5 Parameter is power monitoring mode. When the value is set to 0, the power
     monitoring is in "real-time voltage" mode where the method to determine the battery
     capacity is based on real-time voltage. Once the P5 parameter is set to a specified value,
     the power monitoring is in "smart power" mode where the value set is determined by
     the battery characteristics. Such that, 24V lithium batteries are typically set between
     4-11 and 36V lithium batteries set between 5-15. The P5 parameter setting ranges from
     0-40.
C PARAMETER SETTING
     Enter the C Parameter settings by cycling through the P Parameter Settings to the end
     (when display ceases flashing) and simultaneously holding        button and        button
     for 3 seconds. If required to exit at any parameter, hold      button for 2 seconds. Use
     the       button and        button to select the value and confirm selection by pressing
     the      button. The parameter will be confirmed and the meter will enter the following
     C parameter settings.
20
C1 Throttle Start-Up Setting
 The C1 parameter setting will display on the meter after the P Parameter settings. The
 KT-LCD3 will display as follows:
                                          C1 Display
 C1 settings are the power assist sensor parameters. Its definition is shown in the
 following table. As it can be seen from the table, the values for this parameter range
 from 0 to 7.
    KUNTENG             C1            Start         KUNTENG V12           C1       Start
   Power Assist        Value        Sensitivity   Power Assist Sensors   Value   Sensitivity
     Sensors
 Forward 5 Signal       00          Standard        Reverse 6 Signal      05     Standard
                        01            Lower                               06       Lower
                        02           Lowest                               07      Lowest
 Forward 8 Signal       00           Higher        Reverse 10 Signal      05      Higher
                        01          Standard                              06     Standard
                        02            Lower                               07       Lower
 Forward 10 Signal      00           Highest       Reverse 12 Signal      05      Highest
                        01           Higher                               06      Higher
                        02          Standard                              07     Standard
                        Forward and Reverse Waveform
                                                                                               21
C2 Motor Phase Classification Coding Mode
     The C2 parameter setting will display on the meter after C1 settings. The KT-LCD3 will
     display as follows:
                                         C2 Display
     C2 parameters set the different phases of the motor when using a sine wave drive. The
     default value is 0, indicating that the used Quantum motor phase is standard. When the
     parameter is set as a specified value, a particular motor phase is selected. The range of
     values for C2 are between 0-7.
C3 Power Assist Ratio Gear Initialization
     The C3 parameter setting will display on the meter after C2 settings. The KT-LCD3 will
     display as follows:
                                        C3 Display
     C3 parameters are settings for the power assist ratio gear upon start-up, where if the
     rider desires the bike to start up with a power assist ratio gear of 3, the C3 setting
     should be set to 3. The setting range for the C3 parameters are 0-8 (0-5 are only used.
     Production errors produced additional settings of 6-8.
22
C4 Handlebar Function Setting
 The C4 parameter setting will display on the meter after C3 settings. The KT-LCD3 will
 display as follows:
                                        C4 Display
 C4 settings are for the handlebar functions. The setting range is 0-4. This is accompanied
 by a table below, defining each value.
  C4 Value     Throttle startup Mode P4 = 0            Throttle Startup Mode P4 = 1
      0          Zero startup handlebar                      Non-zero startup
               Zero startup, throttle speed      Throttle limited to 6km/h before pedaling
      1
                    limited to 6km/h             and provides full speed after pedal assist
                Zero startup, throttle speed         Non-zero startup, throttle speed
      2
              limited to rider's specification        limited to rider's specification
                  Zero startup, zero gear
      3                                                           Retain
                        effectively
              Throttle gears is distinguished    Throttle gears is distinguished according
      4
              according to the display meter               to the display meter
      5                   Retain                                  Retain
C5 Handlebar Function Setting
 The C5 parameter setting will display on the meter after C4 settings. The KT-LCD3 will
 display as follows:
                                        C5 Display                                            23
     C5 settings are for controlling the maximum operating current. The default value is 10
     and value ranges from 0 to 10. Refer to table below for definition of each value.
                       C5 Value                          Maximum Current Value (A)
                             00                                  Undefined
                             01                                  Undefined
                             02                                  Undefined
                             03                        Maximum Current Value ÷ 2.00
                             04                        Maximum Current Value ÷ 1.50
                             05                        Maximum Current Value ÷ 1.33
                             06                        Maximum Current Value ÷ 1.25
                             07                        Maximum Current Value ÷ 1.20
                             08                        Maximum Current Value ÷ 1.15
                             09                        Maximum Current Value ÷ 1.10
                             10                           Maximum Current Value
C6 Handlebar Function Setting
     The C6 parameter setting will display on the meter after C5 settings. The KT-LCD3 will
     display as follows:
                                          C6 Display
     C6 settings are for the meter's backlight brightness. The default value is 3 and the
     setting range is 1-5.
                       C6 Value                             Backlight Brightness
                             1                                    Dimmest
                             2                                     Darker
                             3                                    Standard
                             4                                    Brighter
                             5                                    Brightest
24
C7 Cruise Function Setting
 The C7 parameter setting will display on the meter after C6 settings. The KT-LCD3 will
 display as follows:
                                        C7 Display
 The cruise function settings can be found in C7. Refer to the following table for definitions
 of C7 values.
                   C7 Value                                    Cruise Function
                       0                                          Disabled
                       1                                          Enabled
C8 Motor Operating Temperature Display Setting
 The C8 parameter setting will display on the meter after C7 settings. The KT-LCD3 will
 display as follows:
                                        C8 Display
 C8 is settings for the motor operating temperature display. Refer to the following table
 for definitions of the C8 values.
                   C8 Value                       Motor Operating Temperature Function
                       0                                          Disabled
                       1                                          Enabled
                                                                                                 25
C9 Startup Password Setting
     The C9 parameter setting will display on the meter after C8 settings. The KT-LCD3 will
     display as follows:
                                         C9 Display
     C9 is the settings for password feature upon startup. The default value is 0. Refer to the
     following table for definition of the function.
                       C9 Value                                Password Function
                           0                                        Disabled
                           1                                        Enabled
     When the feature has been enabled and confirmed by pressing the               button, the
     display will change to the following.
                                  Password Setting Interface
     From here the rider can set the 3 digit passcode starting from the left and sequentially
     progress to the right. Password value range is 000-999. Select the values with the           	
     button,       button, and confirming the selection with the        button.
     PLEASE NOTE: If password is forgotten, the parameters can only be copied (see
     parameter copy) by data source meter prior to being decoded.
26
C10 Restore Default Setting
 The C10 parameter setting will display on the meter after C9 settings. The KT-LCD3 will
 display as follows:
                                        C10 Display
 C10 restores the KT-LCD3 meter to default settings. Refer to table below for definitions.
                  C10 Value                               Restore Default Setting
                         n                                       Disabled
                         y                                        Enabled
 To restore the meter to default settings, select the C10 value "y" to enable the function
 and hold the            button for 2 seconds. All parameters will restore to default values
 and the meter will return to display 1.
C11 Meter Attribute Setting
 The C11 parameter setting will display on the meter after C10 settings. The KT-LCD3 will
 display as follows:
                                         C11 Display
 C11 is meter attribute settings. The setting range is 0-2. Refer to following table for
 definition of values.
                                                                                               27
      C8 Value                                       Meter Attribute
                     Meter uses LCD3 new version of communication protocol, compatible with
          0
                     LCD1 and LCD3
                     Meter uses LCD1 and LCD2 old version communication protocol, it is not
          1
                     compatible with LCD3
                     As data source for copying parameters, the meter transfers the new LCD3
          2
                     parameter to other meters
C12 Controller Minimal Voltage Setting
     The C12 parameter setting will display on the meter after C11 settings. The KT-LCD3 will
     display as follows:
                                            C12 Display
     C12 parameters are settings for the controller's minimum operating voltage (voltage
     shortage value). Refer to the following table to calculate the minimum voltage.
                                                       Minimum Voltage (V)
              C12 Value
                                  24V Controller          36V Controller       48V Controller
                 0              Default Value-2V         Default Value-2V     Default Value-2V
                 1              Default Value-1.5V      Default Value-1.5V   Default Value-1.5V
                 2              Default Value-1V         Default Value-1V     Default Value-1V
                 3              Default Value-0.5V      Default Value-0.5V   Default Value-0.5V
                 4              Default Value=20V       Default Value=30V    Default Value=40V
                 5             Default Value+0.5V       Default Value+0.5V   Default Value+0.5V
                 6              Default Value+1V         Default Value+1V    Default Value+1V
                 7             Default Value+1.5V       Default Value+1.5V   Default Value+1.5V
28
C13 ABS Brakes and Anti-Charge Control Setting
 The C13 parameter setting will display on the meter after C12 settings. The KT-LCD3 will
 display as follows:
                                       C13 Display
 C13 parameters are settings for the ABS braking strength and anti-charge control. Refer
 to the following table for definitions of each C13 value.
  C13 Value        ABS Braking Strength                  Energy Recovery Efficiency
      0                     None                                    None
      1           Class 1 Braking Strength                   Best energy recovery
      2           Class 2 Braking Strength                General energy recovery
      3           Class 3 Braking Strength                Weaker energy recovery
      4           Class 4 Braking Strength                 Poor energy recovery
      5           Class 5 Braking Strength                   Bad energy recovery
 The recommended value for the C13 parameter is 1. Other options should be selected
 with caution for use. Seek professional advice for assistance.
 Be sure to note: the higher the braking intensity level, the higher the braking strength will
 be which results in greater damage to the motor shaft.
                                                                                                 29
C14 Power Assist Tuning Setting
     The C14 parameter setting will display on the meter after C13 settings. The KT-LCD3 will
     display as follows:
                                           C14 Display
     C14 is the parameters for power assist tuning. The default value is 2. Refer to the
     following table for definition of each value.
                       C14 Value                       Assist Strength of Pedal Assist
                           1                                       Weaker
                           2                                      General
                           3                                      Stronger
PARAMETER COPY
     Set parameters (including general project parameters, P parameters and C parameters)
     of any KT-LCD3 meter can be copied to another KT-LCD3 meter. This can be done via
     C11 Meter Attribute Setting, where the meter can become a data source. Use special
     wiring cables to configure the meter as shown below.
                           Meter Parameter Copy Wiring Diagram
30
                                Special Wiring Cable
 Correctly configure and wire the meters and provide a power supply of 48V, 36V or
 24V (VB + positive power supply). Hold     button of the source meter until start up.
 Within 5 seconds, simultaneously hold       button and       button for 2 seconds. If
 successfully completed, the meter will copy the parameters and display the following
 interface.
                             Successful Copy Display
 Please Note: Both C9 start up password and C11 meter attributes cannot be copied.
 And LCD3 meter can only copy to meter of same model.
VERSION INFORMATION
 KT_LCD3_V2.0
 Released on October 20, 2014
                                                                                         31