This document provides technical specifications for the Systec V-40 / V-55 system in 6 points. It lists the connections for compressed air, demineralized water, tap water, drain, interface, and power supply. It also provides comments on the operating parameters and limitations for each connection point as well as information on heat emission, article numbers for different models, and weight.

Uploaded by

Theodore Kouakou
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
178 views1 page

Systec V 40 55 en

This document provides technical specifications for the Systec V-40 / V-55 system in 6 points. It lists the connections for compressed air, demineralized water, tap water, drain, interface, and power supply. It also provides comments on the operating parameters and limitations for each connection point as well as information on heat emission, article numbers for different models, and weight.

Uploaded by

Theodore Kouakou
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

L L

Systec V-40 / V-55


K K

J J

1290
950
770

770
I I

H
500 680 H

500 680

G G

Technical data
No. Description Size DX DE DB Comments
F F
min. 3-10bar / 50l/min., Class 4 according to DIN ISO 8573,
1 Compressed air NW 7,2 O O --
Only with "water cooling with support pressure"
B
1bar water pressure
2 Demineralized water* 3/4" ET X X --
alkaline earth ions < 0,02 mmol/l, conductivity: 0,1 - 15 S/cm
1bar water pressure
E 3 Tap water* 3/4" ET X X -- E
A alkaline earth ions 2,0 mmol/l, conductivity max. 300 S/cm, 11 dH, 200mg/l CaCO3
Systec VX and Systec VE
Temperature-resistant installation (103 C in case of failure)
Temperature is controlled at 70 C (setable)
105

4 Drain 3/4" ET X X X
Systec VB
D D
Temperature-resistant installation (103 C in case of failure)
72 356 479 90
No controlled temperature, Drain height max. 40cm above the floor

5 Interface X X -- RS-232 / RS-485 (Ethernet Network and USB compatible)


1 A
B 6 Power supply* X X X 1x230V+N+PE / 50-50Hz / 16 Ampere / CEE 7/4 socket, Type F
C C

2
50

Art.No.: VX Art.No.: VE Art.No.: VB Heat emission Net weight Test weight*


3 5
Systec V-40 110 kg 155 kg
50

1040 1240 1400 <400 Watt/h


4 6 Systec V-55 1055 1255 1410 <400 Watt/h 115 kg 175 kg
50

B B

X = Standard O = Optional -- = Not Available Lenght dimensions in mm


Allgemein- Oberfl che Ma stab: Gewicht:
toleranz Werkstoff:
* Other media connections available on request ISO 2768 T1-m Bemerkung:

25 Gezeichnet
Datum
13.05.2014
Name
Zilske
* Other voltages and single-phase available on reqiest Kontrolliert
Norm
Systec V- 350

A * Test weight: chamber completely filled with water for pressure test Systec Zng.-Nr.: AZ 1040 EN Rev.: 1 1 A
the autoclave company A0
Status nderungen Datum Name

16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1