The document provides detailed specifications for various models of compressors, including performance data, cooling data, construction details, and electrical requirements. It outlines maximum and minimum operating pressures, capacities, sound levels, and dimensions for both air-cooled and water-cooled models. Additionally, it includes notes on efficiency, installation, and compliance with standards.

Uploaded by

wutangcon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views2 pages

R160ie Eng Data

The document provides detailed specifications for various models of compressors, including performance data, cooling data, construction details, and electrical requirements. It outlines maximum and minimum operating pressures, capacities, sound levels, and dimensions for both air-cooled and water-cooled models. Additionally, it includes notes on efficiency, installation, and compliance with standards.

Uploaded by

wutangcon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

72811.16.

29

CCN: 23663677
Rev.: E
Sheet:1 of 2
Date: 7/20/2011

Model Name R160IE-X110 R160IE-X125 R160IE-X145 R160IE-X200

GENERAL PERFORMANCE DATA

Maximum Operating Pressure (2) barg (psig) 7.5 (110) 8.5 (125) 10 (145) 14 (200)
Rated Discharge Pressure barg (psig) 7 (100 ) 8 (115) 9.5 (135) 13.5 (190)
Minimum Operating Pressure barg (psig) 4.5 (65) 4.5 (65) 4.5 (65) 4.5 (65)
Capacity FAD (1) m³/min (cfm) 29.17 (1030) 27.47 (970) 25.57 (903) 20.53 (725)
Maximum Operating Ambient Temperature °C (°F) 46 (115)
Minimum Operating Ambient Temperature °C (°F) 2 (35)
Maximum System Temperature Setting °C (°F) 109 (228)
Nominal Power - Main Motor HP 200
Main Motor Efficiency (3) Percent 96.2%
Pkg. Input Power with Fan Motor - Air Cooled (4) kW 174.9 174.3 173.3 167.4
Pkg. Input Power with Fan Motor - Water Cooled (4) kW 166.7 166.1 165.1 159.2
Specific Power - Air Cooled (4)(5) kW/m3/min (kW/100cfm) 6.00 (16.98) 6.35 (17.97) 6.78 (19.19) 8.15 (23.09)
Specific Power - Water Cooled (4)(5) kW/m3/min (kW/100cfm) 5.72 (16.18) 6.05 (17.12) 6.46 (18.28) 7.75 (21.96)

SOUND LEVEL (6)


Standard Package - Air Cooled dB(A) 75
Standard Package - Water Cooled dB(A) 72

COOLING DATA (@ Maximum Ambient Temperature & Maximum Discharge Pressure)


Heat Removal Oil Cooler kW (1000 Btu/hr) 167 (570) 165 (563) 165 (562) 171 (583)
Heat Removal Oil and Aftercooler kW (1000 Btu/hr) 208 (711) 206 (702) 205 (701) 206 (703)
Additional Static Pressure (16) Pa (in H2O) 60 (0.25) - 250 (1.0)

Air-cooled
Fan Air Flow m³/min (cfm) 363 (12829)
Fan Motor Nominal Power kW 7.5
Cooling Air Temperature Rise °C (°F) 30 (55) 32 (58) 33 (60) 33 (60)
(7)
Aftercooler CTD, 60 Hz °C (°F) 8 (15) 8 (15) 8 (15) 8 (15)

Water-cooled - Standard Duty


Fan Air Flow m³/min (cfm) 115 (4000)
Fan Motor Nominal Power kW 0.8
Aftercooler CTD (7)(8) °C (°F) 8 (15) 8 (15) 8 (15) 8 (15)
Cooling Water Flow
@ 10°C (50°F) l/min (gal/min) 214 (57) 214 (57) 218 (58) 208 (55)
@ 20°C (68°F) l/min (gal/min) 218 (58) 218 (58) 218 (58) 210 (56)
@ 30°C (86°F) l/min (gal/min) 222 (59) 222 (59) 222 (59) 222 (59)
@ 40°C (104°F) l/min (gal/min) 233 (62) 237 (63) 241 (64) 222 (59)
@ 46°C (115°F) l/min (gal/min) 237 (63) 237 (63) 248 (66) 244 (65)
Cooling Water Temperature Rise @ 30°C °C (°F) 11 (20) 11 (20) 11 (20) 11 (20)
Cooling Water Pressure Drop bar (psi) Less Than 0.41 bar (6 psi)
Cooling Air Temperature Rise @ 30°C °C (°F) 9 (16) 9 (16) 9 (16) 9 (16)

Water-cooled - Harsh Duty


Fan Air Flow m³/min (cfm) 115 (4000)
Fan Motor Nominal Power kW 0.8
Aftercooler CTD (8) °C (°F) 8 (15) 8 (15) 8 (15) 8 (15)
Cooling Water Flow
@ 10°C (50°F) l/min (gal/min) 184 (49) 207 (55) 207 (55) 196 (52)
@ 20°C (68°F) l/min (gal/min) 184 (49) 206 (55) 205 (55) 196 (52)
@ 30°C (86°F) l/min (gal/min) 188 (50) 214 (57) 214 (57) 196 (52)
@ 40°C (104°F) l/min (gal/min) 207 (55) 227 (61) 229 (61) 196 (52)
@ 46°C (115°F) l/min (gal/min) 206 (55) 227 (60) 228 (61) 230 (61)
Cooling Water Temperature Rise @ 30°C °C (°F) 14 (25) 14 (25) 13 (24) 13 (23)
Cooling Water Pressure Drop bar (psi) Less Than 0.41 bar (6 psi)
Cooling Air Temperature Rise °C (°F) 8 (15) 8 (15) 9 (16) 9 (16)

AIR END DATA


Male Rotor Speed Stage 1 RPM 2762 2651 2445 2005
Male Rotor Tip Speed Stage 1 m/sec 32.7 31.4 28.9 23.7
Male Rotor Speed Stage 2 RPM 2631 2528 2336 1925
Male Rotor Tip Speed Stage 2 m/sec 25.1 24.1 22.3 18.3
Full Load Shaft Power kW 160 160 159 153
72811.16.29

CCN: 23663677
Rev.: E
Sheet:2 of 2
Date: 7/20/2011

CONSTRUCTION, FOUNDATION, AND MOUNTING DATA

PIPING CONNECTIONS
Air Discharge Inches BSPT/NPT (9) 3.00
Package Automatic Condensate Drain Inches BSPT/NPT (9) 0.38
Coolant Drain Plug Inches BSPT/NPT (9) 0.75
Diameter of Power Inlet mm / inch Up to 4.0" (removable plate)
Water Inlet and Outlet Connections Inches BSPT/NPT (9) 1.50

COOLANT LUBRICATION DATA


Total Coolant Capacity - Air Cooled litres (US gal) 95 (25)
Total Coolant Capacity - Water Cooled - Std litres (US gal) 90(24)
Total Coolant Capacity - Water Cooled - Harsh litres (US gal) 95 (25)

DIMENSIONS & WEIGHT Base Mounted


Length, Width, Height mm (inches) 2855 / 1836 / 2032 (112.4 / 72.3 / 80)
Net Weight - Air Cooled kg (lb.) 3198 (7050)
Net Weight - Water Cooled kg (lb.) 3175 (7000)
GA Drawing Number - Air Cooled 23570609
GA Drawing Number - Water Cooled 23570617

ELECTRICAL DATA (14) 380V, 3 440V, 3 460V, 3 575V, 3


Motor Enclosure Protection IP55 (TEFC)
(10)
Full Load Package Current - Air Cooled Amps 344 287 275 220
Full Load Package Current - Water Cooled (10) Amps 336 279 267 212
Package Locked Rotor Current Amps 2628 2287 2068 1754
Package Power Factor 0.88 0.88 0.88 0.88

Electrical Installation
Recommended Supply Cable Size (11)(15) mm²/Cu (AWG or kcmil) 350(700) 250(500) 200(400) 150(300)
Recommended Fuse Rating (11)(12) Amps 450 400 350 300

Notes :
( 1 ) FAD (Free Air Delivery) is full package performance including all losses. Tested per ISO 1217 : 2009 Annex C
( 2 ) Maximum pressure at package discharge, value at which compressor will stop when unit operating at maximum target pressure
( 3 ) IE3 efficiency motor
( 4 ) Measured at rated capacity and rated pressure
( 5 ) Specific power guaranteed in accordance with ISO 1217 : 2009 Annex C
( 6 ) Measured in free field conditions per ISO 2151 using Hemispherical Method; ducted inlet and outlet, with + 3 dB(A) tolerance.
( 7 ) 40% Relative Humidity Inlet Air and maximum speed ( For alternate conditions contact Ingersoll Rand)
( 8 ) Ambient temperature equivalent to cooling water inlet temperature
( 9 ) BSPT or NPT, depending on regional standard
(10) Maximum current includes 10% additional current due to fouled filters and elements
(11) Always apply local electrical codes for sizing cables and fusing.
(12) Time delay fuse recommended. Apply local electrical codes for fuse sizing
(13) Coolant volumes listed are approximate. See operator manual for coolant fill proceedure.
(14) Voltage tolerance: 357V - 440V
(15) Cable size based on 90°C copper cables
(16) See detailed scope document 23883374
Product Improvement is a continuing goal at Ingersoll Rand. Design and specifications are subject to change
without notice or obligation.