The document provides detailed engineering data for the GDK22 TAS air compressor models, including performance specifications, cooling data, electrical data, and dimensions. It outlines key metrics such as rated discharge pressure, maximum operating temperatures, motor efficiency, and noise levels. Additionally, it includes notes on testing standards and product improvement commitments by Gardner Denver.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
40 views1 page

GDK22 Tas

The document provides detailed engineering data for the GDK22 TAS air compressor models, including performance specifications, cooling data, electrical data, and dimensions. It outlines key metrics such as rated discharge pressure, maximum operating temperatures, motor efficiency, and noise levels. Additionally, it includes notes on testing standards and product improvement commitments by Gardner Denver.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ENGINEERING DATA SHEET

CCN: 47825235001

GDK22 TAS
Rev.: A
ECN: 1491576
Sheet: 5 of 5
50Hz Date: 2023.07

Model Air GDK22-7A TAS GDK22-8A TAS GDK22-10A TAS GDK22-12.5A TAS

GENERAL PERFORMANCE DATA


(2) 7 8 10 12.5
Rated discharge Pressure barg
Maximum Operating Pressure barg 7.2 8.2 10.2 12.7
Minimum Operating Pressure barg 4.5 4.5 4.5 4.5
Maximum Operating Ambient Temperature °C 40 40 40 40
Minimum Operating Ambient Temperature °C 2 2 2 2
Maximum System Temperature Setting °C 109 109 109 109
Nominal Power - Main Motor kW 22 22 22 22
(3) 91.6% 91.6% 91.6% 91.6%
Main Motor Efficiency %

(1) 3.70 3.60 3.08 2.72


Capacity FAD m³/min
(4) 27.0 27.0 25.9 25.8
Package Input Power with Fan - Air Cooled kW
Package Input Power with Fan&Dryer - Air Cooled 28.0 28.0 26.9 26.8
(4)(5) 7.3 7.6 8.4 9.5
Specific Power - Air Cooled kW/m3/min
(4)(5) 7.6 7.8 8.7 9.8
Specific Power with Dryer - Air Cooled kW/m3/min

(6)
SOUND LEVEL
Noise Level Standard Package - Air Cooled Sound Pressure - dB(A) 68 68 68 68
Noise Level Standard Package - Air Cooled Sound Power - dB(A) 83 83 83 83

3
OIL CARRY OVER mg/m 5 5 5 5

COOLING DATA (@ Maximum Ambient Temperature & Maximum Discharge Pressure)


Heat Removal (Oil Cooler) kW 21.5 21.5 21.5 21.5
Heat Removal (Oil and Aftercooler) kW 26.0 26.0 26.0 26.0

Permitted Additional Static Pressure Pa 30 30 30 30


Permitted Fan Motor Power kW 0.498 0.498 0.498 0.498

Fan Air Flow m³/min 55.0 55.0 55.0 55.0

Cooling Air Temperature Rise @ 40°C °C 22.7 22.7 22.7 22.7

(7) 13.8 13.8 13.8


Aftercooler CTD °C 13.8

AIR END DATA


Male Rotor Speed RPM 4852 4645 4204 3619
Tip Speed Rotor m/sec 27.15 25.99 23.53 20.25
Full Load Shaft Power kW 27.2 24.1 23.8 22.6

(12)
COOLANT LUBRICATION DATA
Total Coolant Capacity - Air Cooled litres 12.6 12.6 12.6 12.6

(8)
PIPING CONNECTIONS
Air Discharge Inches R 1 INCH (FEMALE) 1 INCH (FEMALE) 1 INCH (FEMALE) 1 INCH (FEMALE)
Coolant Drain - Hose Size Inches NPT 0.38 (FEMALE) 0.38 (FEMALE) 0.38 (FEMALE) 0.38 (FEMALE)
Diameter of Power Inlet mm (Inches) 35 (1.4) 35 (1.4) 35 (1.4) 35 (1.4)

DIMENSIONS AND WEIGHT


Length, Width, Height mm 1596, 1246,1855 1596, 1246,1855 1596, 1246,1855 1596, 1246,1855
Net Weight - Air Cooled kg 871 871 871 871
GA Drawing Number - Air Cooled 47818010001 47818010001 47818010001 47818010001

(13)
ELECTRICAL DATA
Motor Speed rpm 1500 1500 1500 1500
Motor Protection TEFC IP55 TEFC IP55 TEFC IP55 TEFC IP55
Starting Model Y- Y- Y- Y-
Insulation Grade F F F F

(9)
Full Load Package Current - Air Cooled

Amps @ 380V 43 43 43 43

(14)
Main Motor Locked Rotor Current

Amps @ 380V 365 365 365 365

Package Power Factor 0.85 0.85 0.85 0.85

Electrical Installation
(10)
Recommended Supply Cable Size

mm²/Cu (Kcmil) @ 380V 25 25 25 25

(10)(11)
Maximum Recommended Fuse Rating

Amps @ 380V 100 100 100 100

Refrigerated Dryer Data


Refrigerant Type-Domestic R134a R134a R134a R134a
Refrigerant Type-Export R404a R404a R404a R404a
Refrigerant Quantity kg 0.3 0.3 0.3 0.3
Fan Air Flow m³/min 42 42 42 42

ISO Class Particles Humidity and Liquid Water Total Oil


Filter Data (Particles Humidity and Liquid Water. Oil)
(16)
ISO Class Data 1.6.1

Notes:
1. FAD (Free Air Delivery) is full package performance including all losses. Tested per ISO 1217 : 2009 Annex C
2. Maximum pressure at package discharge, value at which compressor will stop when unit operating at maximum target pressure
3. IE3 efficiency motor
4. Measured at rated capacity and rated pressure
5. Specific power guaranteed in accordance with ISO 1217 : 2009 Annex C
6. Measured in free field conditions per ISO 2151 using Hemispherical Method; ducted inlet and outlet, with + 3 dB(A) tolerance
7. CTD based on 100°F/38°C inlet air at 40% Relative Humidity (For alternate conditions contact Ingersoll Rand)
8. 'Rc' Thread for domestic standard
9. Maximum current includes 5% additional current due to fouled filters and elements
10. 90°C copper cables. Always apply local electrical codes for sizing cables and system protection
11. Time delay fuse recommended. Apply local electrical codes for fuse sizing
12. Coolant volumes listed are approximate. See operator manual for coolant fill proceedure
13. 50Hz (±2%) motor voltage tolerance: (380V)±7% ;
14. Star-Delta starting current inrush is about 33% of direct starting current
15. During the Star-Delta open-starting transition, the in-rush current value could instantaneously peak from 1.8 to 2.8 times the noted Locked-Rotor-Amperage (LRA) values
16 TAS units deliver ISO Class1-4-2 quality air measured at steady state conditions in accordance with ISO 8573-1:2010, with inlet air to package of 25 (77
17 Package discharge pressure=rated pressure-0.5bar(include water moisture,Hi-efficiency filter, dryer and tube pressure drop)

Product Improvement is a continuing goal at Gardner Denver. Design and specifications are subject to change without notice or obligation.