Residential Gas Meter G6
Exact measurement
and security
Overview Technical Data
The gas meter 6G6L is a compact G6 Maximum flow rate: Qmax = 10 m3/h
meter designed for measurement of gas
Minimum flow rate: Qmin = 0,06 m3/h
supplied to apartments where maximum
consumption of gas is equivalent to Nominal flow rate: Qn = 6 m3/h
10m3/h of air of density of 1,2 kg/m3
Cyclic volume: V = 2,2 dm3
Max. working pressure: Pmax = 0,5 bar
The gas meters can be used for
Index max indication 99999,999 m3/h
measurement of:
∉ Natural gas Starting flow rate: 8 dm3
Weight: 3 kg
∉ City gas
Fireproof up to 650°C up to 0,1 bar
∉ Propane-butane gas
according to EN1359
Gas meter is equipped with pulse magnet
as standard. Pulse transmitter can be Pressure loss curves Typical error curves
added at any time (1 imp = 0,01 m3).
2.0
3
Dimensions 2
1.5
1
1 0
1.0
2 -1 EN 1359 / OIML R31
-2
71/318/EW G
0.5
-3
0 2 4 6 8 10
Qmin
0 Flow rate Q (m3/h)
0 2 4 6 8 10
Flow rate Q (m3/h)
1 – air
2 – natural gas
APATOR METRIX SA Piaskowa 3 83-110 Tczew, Poland
tel. +48-58-53 09 200 fax. +48-58-53 09 300
http://www.metrix.pl e-mail: metrix@metrix.pl