0% found this document useful (0 votes)
316 views2 pages

Earth Leakage Relay Specs

The document describes earth leakage relays from Mikro. It summarizes the features of three models - the NX 301A, NX 302A, and NX 301E. These models provide trip indication, detection of no current transformer connection, and immunity to interference. The NX 302A adds safety output contact, leakage level indicators, and remote reset/test functions. Technical specifications include voltage and current ratings, contact specifications, temperature and humidity ranges, and dimensions.

Uploaded by

AhmadAfiq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
316 views2 pages

Earth Leakage Relay Specs

The document describes earth leakage relays from Mikro. It summarizes the features of three models - the NX 301A, NX 302A, and NX 301E. These models provide trip indication, detection of no current transformer connection, and immunity to interference. The NX 302A adds safety output contact, leakage level indicators, and remote reset/test functions. Technical specifications include voltage and current ratings, contact specifications, temperature and humidity ranges, and dimensions.

Uploaded by

AhmadAfiq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Earth Leakage Relay

www.itmikro.com

NX302A
301A
NX 301E 301E Features
•• Trip starting indicator

•• Detection of no connection to current


transformer for extra safety

•• Relay tripped indicator


NX 301A •• High immunity to electrical interference

Features for NX 302A only


•• Safety output contact

•• Earth leakage level indicators

•• Remote reset and remote test functions

NX 302A

Technical Data
AUXILIARY SUPPLY OUTPUT CONTACTS ZERO - PHASE CURRENT TRANSFORMER
Model NX301A / 302A -240A : 198 ~ 265 V AC Contact arrangement : 1 x manual reset type To operate with Mikro’s ZCT series of current
Model NX301A / 301E -110A : 94 ~ 127 V AC : 1 x safety contact* transformer
Rated frequency : 50 / 60 Hz : NC and NO contacts
VA rating : 3 VA typical available
Rated voltage : 250 V AC ENVIRONMENTAL CONDITIONS
Contact rating :5A Temperature : -10°C to 55°C
Expected electrical life : 100,000 operations Humidity : 5% to 95%,
NX 302A / 301A / 301E

SETTING RANGES at rated current non-condensing


Sensitivity adjustment : 0.03 A to 30 A Expected mechanical life : 5 x 106 operations
Delay time adjustment : 0 sec to 3.0 sec
MECHANICAL
INPUTS Mounting : Panel mounting
Remote Test* / Reset Inputs*: N.O. dry contact Dimension (mm) : 96(w) x 96(h) x 90(d)
PERFORMANCE Approximate weight : 0.4 kg (excluding ZCT)
Setting accuracy : -15% to +0%
Timing accuracy : ±5% INDICATORS
Auxiliary supply : Green indicator
Time delay : Red indicator * Applicable to NX302A series only
Trip : Red indicator ** Applicable to NX301E series only
Real-time leakage current : Red indicator
Earth Leakage Relay

www.itmikro.com

Typical Application Diagram Case Dimensions


96 mm

96 mm
Front

90 mm
NX 301A or NX302A 70 mm

Side

91.0 ± 0.5 mm

91.0 ± 0.5 mm
Panel Cutout
NX 302A

NX 301E
NX 302A / 301A / 301E

Ordering Information
MODEL DESCRIPTION
NX301A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V AC
NX301A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V AC
NX302A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V AC
NX302A -110A For 50 Hz system, auxiliary voltage 94 ~ 127 V AC
NX301E - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V AC
NX301E -110A For 50 Hz system, auxiliary voltage 94 ~ 127 V AC
NX301A - 240A6 For 60 Hz system, auxiliary voltage 198 ~ 265 V AC
NX301A - 110A6 For 60 Hz system, auxiliary voltage 94 ~ 127 V AC
NX302A - 240A6 For 60 Hz system, auxiliary voltage 198 ~ 265 V AC
NX302A -110A6 For 60 Hz system, auxiliary voltage 94 ~ 127 V AC
NX301E - 240A6 For 60 Hz system, auxiliary voltage 198 ~ 265 V AC
NX301E -110A6 For 60 Hz system, auxiliary voltage 94 ~ 127 V AC

You might also like