Control - Turn Stalk Module P21-1012 - 01
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
L L
TABLE "C": SOFTWARE VARIATION
VARIATION CONTROLLING SPECIFICATION
P98-5003E0001, WITH SECTION 7.4.2.2
01 ( FAILURE MANAGEMENT FOR UNDER
BASE NUMBER SOFTWARE VARIATION, CURRENT TURN SIGNALS ) REMOVED.
K SEE TABLE "C" K
02 P98-5000E0001
P21-1012-XXX
DAYTIME RUNNING LAMP
5 OPTION VARIATION,
SEE TABLE "B" NOTES:
1) USE WITH MULTIFUNCTION TURN STALK AND NEW CAB INTERIOR.
TABLE "B": DAYTIME RUNNING 2) FOR FULL MODULE FUNCTION, DESCRIPTION, REFERENCES AND
J LAMP OPTION VARIATION APPLICABLE REGULATIONS, SEE SPECIFICATION AT LATEST J
REVISION PER TABLE "C".
VARIATION DRL ENABLED
( 158.88 ) 3 NO 3 INJECTION MOLDED ENCLOSURE. LID MATERIAL:
PC / ABS - Dow Pulse 830 ( BLACK )
4 YES
( 144.48 )
4) MODULE MOUNTING BOLTS TO BE TORQUED TO
6 FT-LBF ( 8.1 N-m ).
5 PART TRACEABILITY INFORMATION TO BE LOCATED
APPROXIMATELY AS SHOWN.
LABEL TEXT COLOR FOR P21-1012-3XX: BLACK
I LABEL TEXT COLOR FOR P21-1012-4XX: RED I
6) OPERATIONAL VOLTAGE RANGE: 9-16VDC.
( 50.80 ) TABLE "A": ELECTRICAL INPUTS, OUTPUTS POWER AND GROUND
7) OPERATIONAL TEMPERATURE RANGE: -40°C TO +70°C.
( 6.12 ) PIN CATEGORY: DESCRIPTION ACTIVE MAXIMUM
S = SIGNAL INPUT HIGH / LOW STEADY STATE 8) ELECTRONICS ARE CONFORMALLY COATED.
G = GROUND OPERATING CURRENT
( 117.49 ) P = POWER SOURCE 9) MODULE HAS THESE OUTPUTS:
O = OUTPUT - HEADLAMPS ( LOW & HIGH BEAMS )
- DAYTIME RUNNING LAMPS ( POWERED VIA LOW BEAM OUTPUT )
21-WAY CONNECTOR - TURN AND HAZARD LAMPS, AND CHASSIS STOP LAMPS
H - WINDSHIELD WASHER PUMP H
1 ** O LEFT TURN / HAZARD - 20A*** COMBINED - WINDSHIELD WIPER LOW AND INTERMITTENT SPEED CONTROL.
( 103.89 ) 2 ** O LEFT TURN / HAZARD - BETWEEN PINS 1 & 2
10) TURN SIGNAL AND HAZARD FLASH RATE: 85 PER MINUTE.
( 8.34 ) 3 ** P LEFT TURN / HAZARD AND - 25A COMBINED
LEFT TURN / HAZARD/STOP BETWEEN PINS 3 & 6 11) TURN SIGNAL AND HAZARD FLASH DUTY CYCLE:
4 P ACCESSORY ACTIVE SIGNAL - 2A UP TO 16 AMP CURRENT DRAW ON TURN / HAZARD OUTPUTS: 50%
AND WASHER PUMP POWER ABOVE 16 AMP CURRENT DRAW ON TURN / HAZARD OUTPUTS: 35%
5 S HEADLAMPS ON / OFF LOW 14mA 12) MAXIMUM NUMBER OF # 1156 OR # 1157 BULBS ( 27 WATT,
6 ** P LEFT TURN / HAZARD AND - 25A COMBINED 32 CANDLE POWER ) PER TURN SIGNAL OUTPUT, BASED ON CURRENT
G LEFT TURN / HAZARD / STOP BETWEEN PINS 3 & 6 DRAW CALCULATIONS: G
7 S WIPER SPEEDS RESISTOR 52mA OUTPUT MAXIMUM NUMBER
3 INTERMITTENT # 1 - # 4 AND LOW LADDER OF BULBS
8 S HEADLAMPS FLASH LOW 14mA LEFT OR RIGHT
( 44.38 ) 9
9 O LEFT TURN / HAZARD / STOP - 5A TURN / HAZARD
10 O WASHER PUMP - 2A LEFT OR RIGHT
2
21-WAY HEADER CONNECTOR 11 S LEFT AND RIGHT TURN RESISTOR 29mA TURN / HAZARD / STOP
P / N: 1-967625-2 12-WAY HEADER CONNECTOR LADDER
MATING P / N: P20-1132-1621 P / N: 1-967622-5 13) MODULE OUTPUT BEHAVIOR IN THE PRESENCE OF AN
12 S WASHER PUMP ON / OFF LOW 14mA
MATING P / N: P20-1132-1312 OVERCURRENT SITUATION:
F 13 O HEADLAMPS HIGH BEAM - 14A F
14 < SPARE > - LOW BEAM OUTPUT: IF THE LOW BEAM OUTPUT IS SHORTED, IS
15 S HAZARD LAMP ON / OFF LOW 14mA CONNECTED TO BULBS WHICH ARE RATED ABOVE 65 WATTS PER
SIDE, OR FOR SOME OTHER REASON DRAW TOO MUCH CURRENT, THE
16 O HEADLAMPS LOW BEAM - 11.5A OUTPUT WILL SHUT DOWN AND THE HIGH BEAMS WILL ACTIVATE AT
17 < SPARE > REDUCED INTENSITY. AFTER 1 SECOND, THE LOW BEAM OUTPUT WILL
18 S IGNITION ON / OFF HIGH 14mA REACTIVATE. IF THE PROBLEM IS GONE, THE LOW BEAMS WILL REMAIN
( 6.19 ) ACTIVE AND THE HIGH BEAMS WILL SHUT DOWN.
19 * P HEADLAMPS LOW BEAM - 11.5A IF THE PROBLEM PERSISTS, THE LOW BEAM OUTPUT WILL AGAIN SHUT
20 G MODULE GROUND - 300mA DOWN. THIS CYCLE WILL HAPPEN AT MOST FIVE TIMES, AND THE
21 S SWITCH COMMON LOW 1A FINAL STATE WILL BE HIGH BEAMS ON.
E - HIGH BEAM, TURN / HAZARD AND TURN / HAZARD / STOP OUTPUTS: IF E
12-WAY CONNECTOR THE HIGH BEAM OUTPUT, OR A TURN / HAZARD OR TURN / HAZARD / STOP
1 G MODULE GROUND - 300mA OUTPUT IS SHORTED, IS CONNECTED TO TOO MANY BULBS ( SEE
2* P MODULE BATTERY - 1A NOTE # 12 AND TABLE A ), OR FOR SOME OTHER REASON DRAWS TOO MUCH
CURRENT, THE OUTPUT WILL SHUT DOWN. AFTER FIVE SECONDS, THE
3 S HEADLAMPS HI / LOW CYCLE LOW 14mA OUTPUT WILL REACTIVATE. THE OUTPUT WILL ATTEMPT TO REACTIVATE
4 P HEADLAMPS HIGH BEAM - 14A EVERY FIVE SECONDS UNTIL THE PROBLEM IS FIXED.
5 S PARK BRAKE STATUS LOW 14mA
14) KENWORTH REFERENCE DIAGRAMS:
6 S SERVICE BRAKE STATUS HIGH 14mA - TURN, HAZARD AND STOP SIGNALS: P94-1470 OR SUPERSEDING DIAGRAM
7 ** O RIGHT TURN / HAZARD - 20A*** COMBINED - HEADLAMPS: P94-1461 OR SUPERSEDING DIAGRAM
D BETWEEN PINS 7 & 10 - WINDSHIELD WIPERS & WASHER: P94-1465 OR SUPERSEDING DIAGRAM D
8 * / ** P RIGHT TURN / HAZARD AND - 25A COMBINED
RIGHT TURN / HAZARD/STOP BETWEEN PINS 8 & 11 15) PETERBILT REFERENCE DIAGRAM: P94-6023 OR SUPERSEDING DIAGRAM.
TERMINAL DESIGNATIONS PROD X
9 O WIPER MOTOR LOW - 1A 16) SUPERSEDES P21-1009: SERV X
( THIS IS A GROUNDING OUTPUT )
10 ** O RIGHT TURN / HAZARD - 20A*** COMBINED
BETWEEN PINS 7 & 10
1 19 1 10
11 * / ** P RIGHT TURN / HAZARD AND - 25A COMBINED
2 20 2 11 RIGHT TURN / HAZARD / STOP BETWEEN PINS 8 & 11
C 3 21 3 12 12 O RIGHT TURN / HAZARD / STOP - 5A C
* PIN 19 OF THE 21-WAY CONNECTOR, AND PINS 8 & 11 OF THE 12-WAY CONNECTOR, SUPPLY
SECONDARY POWER TO THE CONTROLLER. THIS PREVENTS CONTROLLER SHUT DOWN IF BATTERY
POWER IS LOST ON PIN 2 OF THE 12-WAY CONNECTOR.
** THE FOLLOWING PINS ARE INTERNALLY BUSSED TOGETHER:
PINS 7 & 10 ( 12-WAY CONNECTOR )
PINS 8 & 11 ( 12-WAY CONNECTOR )
PINS 1 & 2 ( 21-WAY CONNECTOR )
PINS 3 & 6 ( 21-WAY CONNECTOR )
B PIN 20 ( 12-WAY CONNECTOR ) & PIN 1 ( 21-WAY CONNECTOR ) B
*** AMPERAGE LIMITS ON THESE TERMINALS IS BASED ON A 35% DUTY CYCLE USAGE.
A A
DWG
SIZE
A0
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1