RTU Setup Form
Please submit to Mission Technical Support by fax or email, (770) 685-7913 • setupforms@123mc.com
Notifications for this RTU will not be sent until Mission receives this form and enters the data. Thoroughly complete the
following form and write N/A if unused. * Indicates a required field.
Installer Name:* Phone Number:*
Customer/Account Name:*
Unit Serial Number:* Install Date:*
Unit Site Name*
(What you want site called when we notify you):
Installation Type:* New Upgrade Wet Well Module: Yes No Solar Power: Yes No
Installation Address
(Needed for mapping on your web portal)
Street:* City:* State:* Zip:*
Latitude: Longitude:
Digital Inputs
M110/M150: Only inputs 1–3 can be setup for pump runtimes. M800/M850: Inputs 1–8 can be setup for pump runtimes.
Items in parentheses are factory defaults. Enter N/A if unused.
Digital Input Type Normal Contact Input Configuration Input Description
Pump Run, State Dry Contact or What customer wants to hear when input is
Input Alarm, or Status Select N/O or N/C Load Sensor Fault or No Fault off-normal
8
Input Type Normal Contact Digital Option Board / Expansion Module Inputs
Alarm or Status State Wire fault detection not available
10
11
12
13
14
15
16
Analog Inputs
Analog Channel 1 Description:
Units: Input Type: Min Value: Max Value:
(FT, PSI, GPM) (4–20 mA/0–5 V)
Low Alarm: Low Restore: High Restore: High Alarm:
Analog Channel 2 Description:
Units: Input Type: Min Value: Max Value:
(FT, PSI, GPM) (4–20 mA/0–5 V)
Low Alarm: Low Restore: High Restore: High Alarm:
Analog Option Board Inputs
Analog Channel 3 Description:
Units: Input Type: Min Value: Max Value:
FT, PSI, GPM (4–20 mA/0–5 V)
Low Alarm: Low Restore: High Restore: High Alarm:
Analog Channel 4 Description:
Units: Input Type: Min Value: Max Value:
FT, PSI, GPM (4–20 mA/0–5 V)
Low Alarm: Low Restore: High Restore: High Alarm:
Analog Channel 5 Description:
Units: Input Type: Min Value: Max Value:
FT, PSI, GPM (4–20 mA/0–5 V)
Low Alarm: Low Restore: High Restore: High Alarm:
Analog Channel 6 Description:
Units: Input Type: Min Value: Max Value:
FT, PSI, GPM (4–20mA/0–5 V)
Low Alarm: Low Restore: High Restore: High Alarm:
Pulse Option Board Inputs
Label Scale Units
Channel
Rainfall, Inflow, Discharge, etc. Rainfall (0.01) Flow (10, 100, 1000) Inches, Gallons, etc.
1
2
Analog Output Option Board
Channel Label Minimum Maximum Units
Gate or Valve Position, Pump Speed, etc.
1
2
Pump Capacities
(gallons per minute)
Pump 1 GPM: Pump 5 GPM:
Pump 2 GPM: Pump 6 GPM:
Pump 3 GPM: Pump 7 GPM:
Pump 4 GPM: Pump 8 GPM:
Output Relay Labels
Service Mode Indicator can be used on any output relay Check box if used
Output Relay 1:
Output Relay 2:
Output Relay 3:
Volumetric Flow Calculations
For M800 and M850 RTUs Only
Option 1—Wet Well Cross-Sectional Area:
Rectangle or square wet well:
Area = length x width
Round wet well:
Area = 3.14 x (diameter/2) x
(diameter/2)
__________ square feet
Level Measurement: Analog Channel Number: ________
Option 2—Fixed Points:
Lead Pump Start Level (feet):
Lead Pump Stop Level (feet):
Installation Notes
Select Setup Type: Upgrade to MyDro New Installation Replacing Competitive System
Please call _______________________________________, I have questions about:
RSF-0718