Technical Information
DOWLEX™ 2006G
Polyethylene Resin 
Overview                Dowlex™ 2006G Polyethylene Resin is an ethylene 1-octene copolymer, suitable for cast film applications and also
                        perfectly designed to give excellent filler acceptance and low torque during compounding.
                        Dowlex™ 2006G offers superior stiffness and excellent temperature resistance making it the perfect partner for down
                        gauging. Films produced using Dowlex™ 2006G offer low shrinkage which is ideal when registered printing is used.
                         
                         
                        Main Characteristics:
                          • Optimum extruder output and process ability, pure or in blends
                           • Superior stiffness and temperature resistance
                         
                         
                        Complies with:
                          • Europe Commission Regulation (EU) No 10/2011
                           • U.S. FDA 21 CFR 177.1520(c )3.2a
                        Consult the regulations for complete details.
Additive                • Antiblock: No                          • Slip: No                                • Processing Aid: No
Physical                                                  Nominal Value (English)             Nominal Value (SI)               Test Method
  Density                                                           0.961 g/cm³                          0.961 g/cm³           ASTM D792
                    1                                               0.963 g/cm³                          0.963 g/cm³           Dow Method
  Base Density
  Melt Index (190°C/2.16 kg)                                            8.0 g/10 min                       8.0 g/10 min        ASTM D1238
Films                                                     Nominal Value (English)             Nominal Value (SI)               Test Method
  Film Thickness - Tested                                                1 mil                              20 µm               
  Tensile Strength                                                                                                             ASTM D882
       MD : Break, 0.79 mil (20 µm)                                  5510 psi                             38.0 MPa
       TD : Break, 0.79 mil (20 µm)                                  2760 psi                             19.0 MPa
       MD : 0.79 mil (20 µm) 2                                       3050 psi                             21.0 MPa
                                2                                    2180 psi                             15.0 MPa
       TD : 0.79 mil (20 µm)
  Tensile Elongation                                                                                                           ASTM D882
       MD : Break, 0.79 mil (20 µm)                                     700 %                              700 %
       TD : Break, 0.79 mil (20 µm)                                     15 %                                15 %
  Elmendorf Tear Strength                                                                                                      ASTM D1922
       MD : 0.79 mil (20 µm)                                            29 g                                29 g
       TD : 0.79 mil (20 µm)                                            390 g                              390 g
Extrusion Notes
 Cast film extrusion conditions:
    • Melt Temperature: 220°C
        • Die gap: 0.7 mm
        • Film thickness: 20 microns
Notes
   
       These are typical properties only and are not to be construed as specifications. Users should confirm results by their own tests.
  1
    Base density is estimated using the assumption that every 1000 ppm of antiblock in the finished product raises the density of the
  polymer by 0.0006 g/cm³. Base density is the estimated density of the polymer if it did not contain any antiblock.
  2
       @ 5% Elongation
                                                                                                                          Form No. 400-00234716en
Page: 1 of 2               ® ™ Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow.                      Rev: 2014-07-01
Product                         The Dow Chemical Company and its subsidiaries (“Dow”) has a fundamental concern for all who make,
                                distribute, and use its products, and for the environment in which we live. This concern is the basis for our
Stewardship                     Product Stewardship philosophy by which we assess the safety, health, and environmental information on
                                our products and then take appropriate steps to protect employee and public health and our environment.
                                The success of our Product Stewardship program rests with each and every individual involved with Dow
                                products ─ from the initial concept and research, to manufacture, use, sale, disposal, and recycle of each
                                product.
Customer                        Dow strongly encourages its customers to review both their manufacturing processes and their
                                applications of Dow products from the standpoint of human health and environmental quality to ensure
Notice                          that Dow products are not used in ways for which they are not intended or tested. Dow personnel are
                                available to answer your questions and to provide reasonable technical support. Dow product literature,
                                including safety data sheets, should be consulted prior to use of Dow products. Current safety data sheets
                                are available from Dow.
Medical                         NOTICE REGARDING MEDICAL APPLICATION RESTRICTIONS: Dow will not knowingly sell or sample
                                any product or service (“Product”) into any commercial or developmental application that is intended for:
Applications Policy             a. long-term or permanent contact with internal bodily fluids or tissues. “Long-term” is contact which
                                   exceeds 72 continuous hours;
                                b. use in cardiac prosthetic devices regardless of the length of time involved (“cardiac prosthetic devices”
                                   include, but are not limited to, pacemaker leads and devices, artificial hearts, heart valves, intra-aortic
                                   balloons and control systems, and ventricular bypass-assisted devices);
                                c. use as a critical component in medical devices that support or sustain human life; or
                                d. use specifically by pregnant women or in applications designed specifically to promote or interfere with
                                   human reproduction.
                                Dow requests that customers considering use of Dow products in medical applications notify Dow so that
                                appropriate assessments may be conducted. Dow does not endorse or claim suitability of its products for
                                specific medical applications. It is the responsibility of the medical device or pharmaceutical manufacturer
                                to determine that the Dow product is safe, lawful, and technically suitable for the intended use. DOW
                                MAKES NO WARRANTIES, EXPRESS OR IMPLIED, CONCERNING THE SUITABILITY OF ANY DOW
                                PRODUCT FOR USE IN MEDICAL APPLICATIONS.
Disclaimer                      NOTICE: No freedom from infringement of any patent owned by Dow or others is to be inferred. Because
                                use conditions and applicable laws may differ from one location to another and may change with time, the
                                Customer is responsible for determining whether products and the information in this document are
                                appropriate for the Customer’s use and for ensuring that the Customer’s workplace and disposal practices
                                are in compliance with applicable laws and other governmental enactments. Dow assumes no obligation
                                or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED
                                WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE
                                EXPRESSLY EXCLUDED.
                                NOTICE: If products are described as “experimental” or “developmental”: (1) product specifications may not be fully determined;
                                (2) analysis of hazards and caution in handling and use are required; (3) there is greater potential for Dow to change specifications
                                and/or discontinue production; and (4) although Dow may from time to time provide samples of such products, Dow is not obligated
                                to supply or otherwise commercialize such products for any use or application whatsoever.
                                NOTICE: This data is based on information Dow believes to be reliable, as demonstrated in controlled
                                laboratory testing. They are offered in good faith, but without guarantee, as conditions and method of use
                                of Dow products are beyond Dow’s control. Dow recommends that the prospective user determine the
                                suitability of these materials and suggestions before adopting them on a commercial scale.
                                To the best of our knowledge, the information contained herein is accurate and reliable as of the date of
                                publication, however we do not assume any liability for the accuracy and completeness of such
                                information.
Additional                      North America                                                     Europe/Middle East                            +800-3694-6367
                                U.S. & Canada:                          1-800-441-4369                                                          +31-11567-2626
Information                                                             1-989-832-1426            Italy:                                          +800-783-825
                                Mexico:                                +1-800-441-4369                                 
                                Latin America                                                     South Africa                                     +800-99-5078
                                Argentina:                            +54-11-4319-0100
                                Brazil:                               +55-11-5188-9000
                                Colombia:                               +57-1-219-6000            Asia Pacific                                  +800-7776-7776
                                Mexico:                               +52-55-5201-4700                                                          +603-7965-5392
www.dowplastics.com             This document is intended for use within Europe
                                Published: 2013-09-30
                                © 2019 The Dow Chemical Company
                                                                                                                                       Form No. 400-00234716en