Technical Information
DOW HDPE05962B
High Density Polyethylene Resin
Overview
DOW HDPE 05962B is a High Density Polyethylene produced via SOLUTION technology. This resin presents a
narrow molecular weight distribution that offers excellent impact resistance in rigid packaging, high gloss, excellent
stiffness and processability.
Main Characteristics
Resin for Injection Molding
Pails and Crates
Resin for Cast film
Film for diapers, femine hygiene
Complies with:
U.S. FDA 21 CFR 177.1520 (c) 3.1a
EU, No 10/2011
Consult the regulations for complete details
Additive
Antiblock: No
Physical
Slip: No
Nominal Value (English)
Density
0.958 g/cm
Melt Index (190C/2.16 kg)
5.0 g/10 min
Processing Aid: No
Nominal Value (SI)
0.958 g/cm
5.0 g/10 min
Environmental Stress-Cracking Resistance
Compression Molded
Mechanical
ASTM D792
ASTM D1238
ASTM D1693
44.0 hr
Nominal Value (English)
44.0 hr
Nominal Value (SI)
Tensile Strength
Test Method
ASTM D638
Yield, Compression Molded
4210 psi
29.0 MPa
Break, Compression Molded
3630 psi
25.0 MPa
Tensile Elongation
ASTM D638
Break, Compression Molded
Flexural Modulus (Compression Molded)
Films
2400 %
16000 psi
Nominal Value (English)
Film Thickness - Tested
0.94 mil
Film Puncture Resistance (0.94 mil (24 m))
40.0 ftlb/in
2400 %
110 MPa
Nominal Value (SI)
24 m
3.31 J/cm
Secant Modulus
ASTM D790
Test Method
Dow Method
ASTM D882
2% Secant, MD : 0.94 mil (24 m)
68500 psi
472 MPa
2% Secant, TD : 0.94 mil (24 m)
97500 psi
672 MPa
MD : Yield, 0.94 mil (24 m)
3920 psi
27.0 MPa
TD : Yield, 0.94 mil (24 m)
4060 psi
28.0 MPa
MD : Break, 0.94 mil (24 m)
5220 psi
36.0 MPa
TD : Break, 0.94 mil (24 m)
4060 psi
28.0 MPa
Tensile Strength
ASTM D882
Tensile Elongation
ASTM D882
MD : Break, 0.94 mil (24 m)
600 %
600 %
TD : Break, 0.94 mil (24 m)
650 %
650 %
8.0 g
8.0 g
Dart Drop Impact (0.94 mil (24 m))
Elmendorf Tear Strength
40 g
40 g
TD : 0.94 mil (24 m)
120 g
120 g
Impact
Nominal Value (English)
Notched Izod Impact (Compression Molded)
Hardness
0.47 ftlb/in
Nominal Value (English)
Durometer Hardness (Shore D)
ASTM D1709A
ASTM D1922
MD : 0.94 mil (24 m)
Page: 1 of 3
Test Method
82
Nominal Value (SI)
25 J/m
Nominal Value (SI)
82
Trademark of The Dow Chemical Company (Dow) or an affiliated company of Dow.
Test Method
ASTM D256
Test Method
ASTM D2240
Form No. 400-00084177en
Rev: 2012-07-24
Optical
Nominal Value (English)
Nominal Value (SI)
Test Method
Gloss (45, 0.945 mil (24.0 m))
85
85
ASTM D2457
Haze (0.945 mil (24.0 m))
6.0 %
6.0 %
ASTM D1003
Extrusion
Melt Temperature
Nominal Value (English)
515 F
Nominal Value (SI)
268 C
Notes
These are typical properties only and are not to be construed as specifications. Users should confirm results by their own tests.
Page: 2 of 3
Trademark of The Dow Chemical Company (Dow) or an affiliated company of Dow.
Form No. 400-00084177en
Rev: 2012-07-24
Product
Stewardship
The Dow Chemical Company and its subsidiaries (Dow) has a fundamental concern for all who make,
distribute, and use its products, and for the environment in which we live. This concern is the basis for our
Product Stewardship philosophy by which we assess the safety, health, and environmental information on
our products and then take appropriate steps to protect employee and public health and our environment.
The success of our Product Stewardship program rests with each and every individual involved with Dow
products from the initial concept and research, to manufacture, use, sale, disposal, and recycle of each
product.
Customer
Notice
Dow strongly encourages its customers to review both their manufacturing processes and their
applications of Dow products from the standpoint of human health and environmental quality to ensure
that Dow products are not used in ways for which they are not intended or tested. Dow personnel are
available to answer your questions and to provide reasonable technical support. Dow product literature,
including safety data sheets, should be consulted prior to use of Dow products. Current safety data sheets
are available from Dow.
Medical
Applications Policy
NOTICE REGARDING MEDICAL APPLICATION RESTRICTIONS: Dow will not knowingly sell or sample
any product or service (Product) into any commercial or developmental application that is intended for:
a. long-term or permanent contact with internal bodily fluids or tissues. Long-term is contact which
exceeds 72 continuous hours;
b. use in cardiac prosthetic devices regardless of the length of time involved (cardiac prosthetic devices
include, but are not limited to, pacemaker leads and devices, artificial hearts, heart valves, intra-aortic
balloons and control systems, and ventricular bypass-assisted devices);
c. use as a critical component in medical devices that support or sustain human life; or
d. use specifically by pregnant women or in applications designed specifically to promote or interfere with
human reproduction.
Dow requests that customers considering use of Dow products in medical applications notify Dow so that
appropriate assessments may be conducted. Dow does not endorse or claim suitability of its products for
specific medical applications. It is the responsibility of the medical device or pharmaceutical manufacturer
to determine that the Dow product is safe, lawful, and technically suitable for the intended use. DOW
MAKES NO WARRANTIES, EXPRESS OR IMPLIED, CONCERNING THE SUITABILITY OF ANY DOW
PRODUCT FOR USE IN MEDICAL APPLICATIONS.
Disclaimer
NOTICE: No freedom from infringement of any patent owned by Dow or others is to be inferred. Because
use conditions and applicable laws may differ from one location to another and may change with time, the
Customer is responsible for determining whether products and the information in this document are
appropriate for the Customers use and for ensuring that the Customers workplace and disposal practices
are in compliance with applicable laws and other governmental enactments. Dow assumes no obligation
or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE
EXPRESSLY EXCLUDED.
NOTICE: If products are described as experimental or developmental: (1) product specifications may
not be fully determined; (2) analysis of hazards and caution in handling and use are required; (3) there is
greater potential for Dow to change specifications and/or discontinue production; and (4) although Dow
may from time to time provide samples of such products, Dow is not obligated to supply or otherwise
commercialize such products for any use or application whatsoever.
Additional
Information
North America
U.S. & Canada:
Mexico:
Latin America
Argentina:
Brazil:
Colombia:
Mexico:
www.dowplastics.com
Europe/Middle East
1-800-441-4369
1-989-832-1426
+1-800-441-4369
Italy:
South Africa
+54-11-4319-0100
+55-11-5188-9000
+57-1-219-6000
+52-55-5201-4700
Asia Pacific
+800-3694-6367
+31-11567-2626
+800-783-825
+800-99-5078
+800-7776-7776
+603-7965-5392
This document is intended for use within Latin America
Published: 2005-05-05
2015 The Dow Chemical Company
Page: 3 of 3
Trademark of The Dow Chemical Company (Dow) or an affiliated company of Dow.
Form No. 400-00084177en
Rev: 2012-07-24