DPM380 2

The document describes a digital power meter that measures various electrical parameters. It has an LCD display with Modbus communication and measures voltages, currents, power factors, energy usage, harmonics and demand over configurable time intervals. It is designed for panel mounting and has IP54 protection. Power supply options include 90-415V AC or 100-300V DC. Communication is via isolated RS485 using Modbus RTU protocol. Typical wiring diagrams show applications for 3-phase 4-wire and 3-wire systems using various combinations of current transformers and voltage transformers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
204 views2 pages

DPM380 2

The document describes a digital power meter that measures various electrical parameters. It has an LCD display with Modbus communication and measures voltages, currents, power factors, energy usage, harmonics and demand over configurable time intervals. It is designed for panel mounting and has IP54 protection. Power supply options include 90-415V AC or 100-300V DC. Communication is via isolated RS485 using Modbus RTU protocol. Typical wiring diagrams show applications for 3-phase 4-wire and 3-wire systems using various combinations of current transformers and voltage transformers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Digital Power Meter

www.itmikro.com

DPM 380
380B
Features
LCD display with back lighting with Modbus-RTU
communication

MEASUREMENT PARAMETERS:
• Phase Voltage (L-N) & Line Voltage (L-L)
• Min & Max Phase and Line Voltage
• Phase Current and Neutral Current
• Min & Max Phase Current and Neutral Current
• Bidirectional kW (per phase & total)
• Bidirectional kVAR (per phase & total)
• kVA (per phase & total)
• Min & Max kW, kVAR and KVA
• Frequency
• True & Displacement Power Factor (per phase &
total)
• Energy kWh, kVARh and kVAh
• THD Phase Voltage ( L-N )
• THD Phase Current
• Power Demand (kW, kVAR & kVA)
• Maximum Power Demand (kW, kVAR & kVA)

Technical Data
DISPLAY TYPE POWER DEMAND ENVIRONMENTAL CONDITIONS
LCD display Interval : 1 ~ 30 mins Temperature : -10°C to 55°C
Humidity : 5% to 95%,
MEASUREMENTS POWER FACTOR MEASUREMENT non-condensing
3-phase 4-wire system Total and displacement power factor
3-phase 3-wire system Accuracy : 1.0% MECHANICAL
Mounting : Panel mounting
CURRENT MEASUREMENT (TRMS) FREQUENCY MEASUREMENT Dimension (mm) : 96(w) x 96(h) x 87.5(d)
CT primary : 5 ~ 9995 A Measurement range : 45 ~ 65 Hz Approximate weight : 0.48kg
CT secondary : 5 A Measurement updating period : 1s Enclosure protection : IP54 at the panel
Minimum measurement : 5 mA Accuracy : 0.5% IP20 at the body
Accuracy : 0.5% from 1A to
6 A (secondary) ENERGY ACCURACY
Burden : < 0.05 VA at 5 A Active (according to IEC 62053-21) : class 1
Sustained overload : 6 A Reactive (according to IEC 62053-23) : class 2
DPM 380/380B

VOLTAGE MEASUREMENT (TRMS) AUXILIARY POWER SUPPLY


Nominal phase voltage : 20 ~ 300 V AC AC voltage : 90 ~ 415 V AC
Minimum measurement :10 V Frequency : 50 / 60 Hz
Accuracy : 0.5% at full scale DC voltage : 100 ~ 300 V DC
Phase voltage via VT : 60 ~ 33,000 V Power consumption : <3 VA

POWER MEASUREMENT COMMUNICATION


Real power, apparent power, reactive Hardware interface : Isolated RS485
power Protocol : Modbus-RTU
measurement Baud rate : 2400, 4800, 9600,
Measuring updating period : 1 s 19200, 38400
Accuracy : 1.0%
Digital Power Meter

www.itmikro.com

Typical Application Diagram Case Dimensions


3-PHASE 4-WIRE SYSTEM:4CTs, direct V input. 3-PHASE 4-WIRE SYSTEM:3CTs, direct V input.

19 19
20 20
1 1
2 2 Front

96mm
3 3
4 4
5 5
6 6
7 7
8 8
13
15 15 14 96mm
13
16 12
14 16

17 12
17
18 18

Rear

90.5mm
3-PHASE 3-WIRE SYSTEM:3CTs, 3VTs 3-PHASE 3-WIRE SYSTEM:2CTs, 3VTs

19 19
20 20
1 1
2 2 17.5mm
3 87.5mm
3
4 4
5 5
6 6
7 7
8 8
13 13
15 15
14 14 1 2 3 4 5 6 7 8
16 12 12
16 90.5mm
17 17
18 18
9 10 11 12 13 14 Back
15 16 17 18 19 20

90.5mm

Cut-Out Recommendations
−0.5mm

Electromagnetic Compatibility (EMC)


91 +

Part 6-2: Generic Standards IEC61000-6-2


Immunity for industrial environments.
91 +
− 0.5mm
DPM 380 / 380B

Part 6-4: Generic Standards IEC61000-6-4


Emission standard for industrial environments.

Ordering Information
MODEL DESCRIPTION
DPM 380-415AD Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC, with RS 485
DPM 380B-415AD Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC