0% found this document useful (0 votes)
324 views3 pages

IPD3005C Datasheet

The document discusses the IPD3005C digital three-phase energy meter. It features DIN rail mounting, true RMS measurements, a large LCD display, IEC 62053-22 Class 0.5S kWh accuracy for 5A CT input, a metrological LED, solid state pulse output, 2MB memory, 3 digital inputs, and RS-485/Modbus communication. It provides basic measurements including voltage, current, power, power factor, demands, harmonics, and TOU data logging and recording.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
324 views3 pages

IPD3005C Datasheet

The document discusses the IPD3005C digital three-phase energy meter. It features DIN rail mounting, true RMS measurements, a large LCD display, IEC 62053-22 Class 0.5S kWh accuracy for 5A CT input, a metrological LED, solid state pulse output, 2MB memory, 3 digital inputs, and RS-485/Modbus communication. It provides basic measurements including voltage, current, power, power factor, demands, harmonics, and TOU data logging and recording.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

NMI/SUB BILLING METERING

IPD3005C
DIGITAL KWH METER 5A , CT CONNECT 415V RS485 MODBUS COMMUNICATION DIN MTG.
ENERGY MANAGEMENT > NMI/SUB-BILLING METERING > THREE PHASE MULTIFUNCTION METER

OVERVIEW
The IPD3005C series Digital Three-Phase Energy Meter is IPD’s latest offer for the low voltage power/energy metering market featuring DIN rail mount, high accuracy, multifunc-
tion true RMS measurements and a large, easy to read LCD display. The IPD3005C series complies with IEC 62053-22 Class 0.5S kWh accuracy standards for 5A CT Input. The
IPD3005C series comes standard with a metrological LED as well as a Solid State Pulse Output for energy pulsing. The IPD3005C series provides 2MB memory for Data Recording
and 3 Digital Inputs for status monitoring, Tariff switching or pulse counting for collecting Water, Air, Gas, Electric and Steam information from 3rd party metering devices. The
standard RS-485 port and Modbus protocol support allows the IPD3005C series to become a vital component of an intelligent, multifunction monitoring solution for any Power
and Energy Management Systems.

FEATURES
Ease of use
- Large, easy to read LCD
- Two LED indicators for energy pulsing and communication activities
- Password-protected setup via front panel
- Easy installation with DIN rail mounting, no tools required
- 3-phase power supply, no external control power required

Basic Measurements
- Multifunction True RMS measurements
• Voltage, Current, kW, kvar, kVA, PF, Phase Angle and Frequency
• Per phase and Total kWh and kvarh Imp/Exp/Tot/Net and kVAh
• 4-Quadrant kvarh
• Device Operating Time (Running Hour)
• Voltage and Current THD, TOHD, TEHD, Individual Harmonics up to 31st and
unbalance
DIMENSIONS AND INSTALLATION • Current K-Factor, Crest Factor, TDD, TDD Odd and TDD Even
• I1, I2, I3, kW/kvar/kVA Total Demands and Max. Demands
L1, L2, L3 N from Source - Max/Min Log
- 12 monthly recording of kWh/kvarh Imp/Exp/Tot/Net, kVAh, kvarh Q1-Q4 as
Voltage Input
well as kWh/kvarh Imp/Exp and kVAh per Tariff
(5A CT Input Option)
- Two TOU schedules, each providing
• 12 Seasons
• 20 Daily Profiles, each with 12 Periods in 15-minute interval
• 90 Holidays or Alternate Days
• 4 Tariffs, each providing the following information
Pulse Output o kWh/kvarh Import/Export, kVAh
o kW/kvar/kVA Max. Demands
Energy Pulse & - 2MB Log Memory
Comm. LEDs - Data Recorder Log of 16 measurements @ 10-minute interval for 197 days
- 16 SOE events time-stamped to 1ms resolution
Buttons
- Front Panel & Communication Programming Counters

Digital Inputs
- 3 channels for external status monitoring and pulse counting
RS-485 - Self-excited, internally wetted at 24VDC
Digital Input
Pulse Outputs
- 1 Front Panel LED and 1 Solid State Pulse Output for energy pulsing application

L1, L2, L3 N to Load Communications


- Optically isolated RS485 port, baud rate from 1200 to 19,200 bps
- Modbus RTU protocol
DIMENSIONS AND INSTALLATION
Real-time Clock
- Battery-backed real-time clock @ 6ppm
- Clock error ≤ 0.5s/day

System Integration
- Easy integration into other Automation or SCADA systems via Modbus RTU protocol

TYPICAL APPLICATIONS
- DIN rail mount energy metering
- Industrial and commercial metering
- Substation, building and factory automation
- Sub-metering
- Power quality monitoring
- NMI Pattern Approval Metering

1
NMI/SUB BILLING METERING

IPD3005C

SPECIFICATIONS
Part No. IPD3005C

Inputs (L1, L2, L3, N)


Voltage (Un) 240VLN
Range 0.7 to 1.1 Un
Burden <10VA/phase

CT Input
Current (In/Imax) 5A/6A
Range (0.1%-120%) In
Starting Current 0.1% In
Burden <0.5VA/phase
Frequency 45Hz-65Hz

Solid State Energy Pulse Output (Selectable - kWh/kvarh)


Pulse Constant 1/10/100/1000/3200 imp/kWh (imp/kvarh)
Isolation Optical
Max. Load Voltage 80V
Max. Forward Current 50mA
Pulse Width 60-150ms

Communications
RS-485 Modbus RTU
Baudrate 1200/2400/4800/9600/19200 bps
Maximum Wire Size 1.5mm2 (16AWG)
Maximum Torque 0.45 N.m

Environmental Conditions
Operating temp. -25°C to +70°C
Storage temp. -40°C to +85°C
Humidity 5% to 95% non-condensing
Atmospheric pressure 70 kPa to 106 kPa
Pollution Degree 2

Mechanical Characteristics
Mounting DIN Rail
Unit Dimensions 126x90x65mm
Shipping Dimensions 165x140x110mm
Shipping Weight TBD
IP Rating 51 (Front), 30 (Body)

ACCURACY
Parameters Accuracy Resolution
Voltage ±0.5% 0.01V
Current ±0.5% 0.001A
kW, kvar, kVA ±1% 0.01kW/kvar/kVA
kWh, kVAh IEC 62053-22 Class 0.5S for 5A CT Input 0.01kXh
kvarh IEC 62053-23 Class 2 0.01kvarh
P.F. ±1% 0.001
Frequency ±0.02Hz 0.001Hz
Harmonics IEC 61000-4-7 Class B 0.1%

2
NMI/SUB BILLING METERING

IPD3005C

STANDARDS OF COMPLIANCE

Safety Requirements
CE LVD 2014 / 35 / EU EN 61010-1: 2010 / EN 61010-2-030: 2010
Insulation IEC 62052-11: 2003, NMI M6-1
AC Voltage 4kV @ 1 minute
Impulse voltage 10kV, 1.2/50µs (NMI M6-1)
Electrical safety in low voltage distribution systems
IEC 61557-12: 2008 (PMD)
up to 1000Vac and 1500Vdc

Electromagnetic Compatibility
CE EMC Directive 2014 / 30 / EU (EN 61326: 2013)

Immunity Tests
Electrostatic discharge EN 61000-4-2: 2009
Radiated fields EN 61000-4-3: 2006+A1: 2008+A2: 2010
Fast transients EN 61000-4-4: 2012
Surges EN 61000-4-5: 2006
Conducted disturbances EN 61000-4-6: 2009
Magnetic Fields EN 61000-4-8: 2010
V Dips, Interruptions & Variations EN 61000-4-11:2004
Oscillatory waves EN 61000-4-12: 2006
Radio Disturbances CISPR 22:2006, Level B

Emission Tests
Limits and methods of measurement of electromagnetic disturbance characteristics EN 55011: 2009 + A1: 2010
of industrial, scientific and medical (ISM) radio-frequency equipment (CISPR 11)
Limits and methods of measurement of radio disturbance characteristics of EN 55022: 2010+AC: 2011
information technology equipment (CISPR 22)
Limits for harmonic current emissions for equipment with rated current ≤16 A EN 61000-3-2: 2014
Limitation of voltage fluctuations and flicker in low-voltage supply systems for
EN 61000-3-3: 2013
equipment with rated current ≤16 A
Emission standard for industrial environments EN 61000-6-4: 2007+A1: 2011
Testing and measurement techniques- Ring wave immunity test. EN 61000-4-12: 2006

Mechanical Tests
Spring Hammer Test IEC 62052-11: 2003
Vibration Test IEC 62052-11: 2003
Shock Test IEC 62052-11: 2003

Revenue Metering Approval