0% found this document useful (0 votes)
195 views30 pages

L022 Sce

This document outlines the scope of accreditation for DEKRA Certification B.V. from July 6th, 2022 to May 1st, 2026. It includes their head office location in Arnhem, Netherlands where they perform testing activities for electrical safety, parameters, dielectric properties, and isolation of cables, cords, and conduits. The testing is conducted according to various international, European, and internal standards.

Uploaded by

esuarezal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
195 views30 pages

L022 Sce

This document outlines the scope of accreditation for DEKRA Certification B.V. from July 6th, 2022 to May 1st, 2026. It includes their head office location in Arnhem, Netherlands where they perform testing activities for electrical safety, parameters, dielectric properties, and isolation of cables, cords, and conduits. The testing is conducted according to various international, European, and internal standards.

Uploaded by

esuarezal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 30

Annex to declaration of accreditation (scope of accreditation)

Normative document: EN ISO/IEC 17025:2017


Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

Location(s) where activities are performed under accreditation

Head Office

Meander 1051
6825 NL
Arnhem
The Netherlands

Location Abbreviation/ location code


Meander 1051 A.
6825 NL
Arnhem
The Netherlands

No. Material or Type of activity1 Internal reference number Location


product

Electrical Safety Tests

1
If there is a referral to a code starting with NAW, NAP, EA or IAF, this concerns a scheme mentioned on RvA-BR010-lijst.
If no date or version number is mentioned for a normative document, the accreditation concerns the most current version of the document or scheme.

This annex has been approved by the Board of the


Dutch Accreditation Council, on its behalf,

J.A.W.M. de Haas

Dutch Accreditation Council RvA Page 1 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product

1. Cables
. and cords Type test of cables and cords according HD 21 A.
(CABL) to the tests in the standard: HD 22
HD 603
- Fire and Flammability tests HD 604
- Electric parameter tests HD 605
- Dielectric properties determination
- Mechanical Tests EN 13501, EN 50143;
- Isolation properties determination EN 50214; EN 50267;
EN 50525; EN 50288;
EN 50399; EN 50618

NEN/EN 50200
NEN/EN/IEC 60228
NEN-EN 50525
NEN/EN 50266
NEN/EN 50362
NEN/EN /IEC 61034

IEC 60092, IEC 60227-1,


IEC 60227-2, IEC 60227-3,
IEC 60227-5, IEC 60227-7;
IEC 60331; IEC 60332; IEC 60502-1;
IEC 60502-2; IEC 60754; IEC 60800;
IEC 60840; IEC 62067

DEKRA K 42; DEKRA K 102


DEKRA K 145; DEKRA K 146
DEKRA K 151; DEKRA K 152
DEKRA K 156; DEKRA K 157
DEKRA K 158; DEKRA K160
DEKRA K 161; DEKRA K 162
DEKRA K 163; DEKRA K 164
DEKRA K 165; DEKRA K 167
DEKRA K 168; DEKRA K 169
DEKRA K 170; DEKRA K 171
DEKRA K 175; DEKRA K 176
DEKRA K 177; DEKRA K 178
DEKRA K 179

Dutch Accreditation Council RvA Page 2 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product

BS 6004; BS 6007; BS 4553; A.


BS 5467; BS 6231; BS 6346;
BS 6387; BS 6500; BS 6622;
BS 6724; BS 6883; BS 7211;
BS 7629; BS 7835; BS 7846; BS
7889; BS 8491; BS EN 50288-7
BS EN 50525

DIN VDE0815; DIN VDE0250

2. Cables and cords Test methods for non-metallic materials IEC 60811-201; IEC 60811-202 A.
(CABL) IEC 60811-203; IEC 60811-401
IEC 60811-402; IEC 60811-403
IEC 60811-404; IEC 60811-405
IEC 60811-406; IEC 60811-408
IEC 60811-409; IEC 60811-411
IEC 60811-412; IEC 60811-501
IEC 60811-502; IEC 60811-503
IEC 60811-504; IEC 60811-505
IEC 60811-506; IEC 60811-507
IEC 60811-508; IEC 60811-509
IEC 60811-510; IEC 60811-511
IEC 60811-605; IEC 60811-606
IEC 60811-607

3. Cables and cords Electrical test methods for low voltage A.


NEN-EN 50395
(CABL) energy cables

4. Cables and cords Non electrical test methods for low NEN-EN 50396 A.
(CABL) voltage energy cables

5. Conduits Type test of conduits according to the NEN/EN/IEC 61386 A.


tests in the standard, among others:
DEKRA K24
- electrical safety tests
EN 50086
- mechanical tests

- environmental tests

Dutch Accreditation Council RvA Page 3 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product

6. Installation Type test of cable trays and cable KEMA 55 A.


systems ladders, according to the tests in the
standard, among others: NEN/EN 50085
Cable trays NEN/IEC/EN 61537
- electrical safety tests
Cable ladders BS EN 61537
- mechanical tests

- environmental tests

7. Boxes and Type test of boxes and enclosures for NEN/EN/IEC 60670 A.
enclosures for electrical installations, according to the
electrical tests in the standard, among others:
installations
- electrical safety tests

- mechanical tests

- environmental tests
IEC 60730-1, EN 60730-1
8. Switches for Type test according to the tests in the A.
IEC 60730-2-2, EN 60730-2-2
appliances and standard:
IEC 60730-2-3, EN 60730-2-3
automatic controls
- Temperature tests IEC 60730-2-4, EN 60730-2-4
for electrical
- Water and dust ingress tests IEC 60730-2-6, EN 60730-2-6
household
- Chemical tests IEC 60730-2-7, EN 60730-2-7
appliances
- Fire and Flammability tests IEC 60730-2-8, EN 60730-2-8
(CONT)
- Electric parameter tests IEC 60730-2-9, EN 60730-2-9
- Short circuit tests IEC 60730-2-10, EN 60730-2-10
IEC 60730-2-11, EN 60730-2-11
- Dielectric properties determination
IEC 60730-2-22, EN 60730-2-22
- Endurance tests
IEC 61095, EN 61095
- Mechanical Tests
IEC 61058 zie Cat. INST
- Radiation tests
IEC/EN 60691, 60934, 60529,
- Isolation properties determination. IEC 60265, 62271-1, 62271-100,
62271-101, 62271-102, 62271-105,
62271-110, 62271-200, 62271-201,
62271-202, 62271-203, EN 50152-1

IEEE Std C37.09, C37.081, 37.60,


C37.013, C37.34,
ANSI C37.41, C37.73, C37.20.2,
C37.122
ANSI/IEEE C37.21
ANSI C37.54, C37.55, C37.20.2,
C37.72

Dutch Accreditation Council RvA Page 4 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
IEC 60335-2-2, EN 60335-2-2
9. Household and Type test of household equipment A.
IEC 60335-2-3, EN 60335-2-3
similar equipment according to the tests in the standard:
IEC 60335-2-4, EN 60335-2-4
(HOUS)
- Temperature tests IEC 60335-2-5, EN 60335-2-5
- Water and dust ingress tests IEC 60335-2-6, EN 60335-2-6
- Fire and Flammability tests IEC 60335-2-7, EN 60335-2-7
- Electric parameter tests IEC 60335-2-8, EN 60335-2-8
- Short circuit tests IEC 60335-2-9, EN 60335-2-9
- Dielectric properties determination IEC 60335-2-10, EN 60335-2-10
IEC 60335-2-11, EN 60335-2-11
- Endurance tests
IEC 60335-2-12, EN 60335-2-12
- Mechanical Tests
IEC 60335-2-13, EN 60335-2-13
- Radiation tests
IEC 60335-2-14, EN 60335-2-14
- EMC – Emission tests
IEC 60335-2-15, EN 60335-2-15
- Isolation properties determination IEC 60335-2-17, EN 60335-2-17
IEC 60335-2-21, EN 60335-2-21
IEC 60335-2-23, EN 60335-2-23
IEC 60335-2-24, EN 60335-2-24
IEC 60335-2-25, EN 60335-2-25
IEC 60335-2-27, EN 60335-2-27
IEC 60335-2-30, EN 60335-2-30
IEC 60335-2-31, EN 60335-2-31
IEC 60335-2-32, EN 60335-2-32
IEC 60335-2-35, EN 60335-2-35
IEC 60335-2-36, EN 60335-2-36
IEC 60335-2-40, EN 60335-2-40
IEC 60335-2-41, EN 60335-2-41
IEC 60335-2-42, EN 60335-2-42
IEC 60335-2-52, EN 60335-2-52
IEC 60335-2-54, EN 60335-2-54
IEC 60335-2-58, EN 60335-2-58
IEC 60335-2-60, EN 60335-2-60
IEC 60335-2-61, EN 60335-2-61
IEC 60335-2-64, EN 60335-2-64
IEC 60335-2-65,EN 60335-2-65
IEC 60335-2-67, EN 60335-2-67
IEC 60335-2-68, EN 60335-2-68
IEC 60335-2-69, EN 60335-2-69
IEC 60335-2-72, EN 60335-2-72
IEC 60335-2-75, EN 60335-2-75
IEC 60335-2-79, EN 60335-2-79
IEC 60335-2-80, EN 60335-2-80
IEC 60335-2-81, EN 60335-2-81
IEC 60335-2-87, EN 60335-2-87
IEC 60335-2-88, EN 60335-2-88

Dutch Accreditation Council RvA Page 5 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
IEC 60335-2-89, EN 60335-2-89
IEC 60335-2-90, EN 60335-2-90
IEC 60335-2-96, EN 60335-2-96
IEC 60335-2-97, EN 60335-2-97
IEC 60335-2-98, EN 60335-2-98
IEC 60335-2-99, EN 60335-2-99
IEC 60335-2-101, EN 60335-2-101
IEC 60335-2-109, EN 60335-2-109

IEC/EN 61770
IEC/EN 62233
EN 50366
IEC/EN 60204
IEC/EN 60730-1/ 2-8 / 2-9
IEC/EN 61558-1/ 2-3 / 2-6 / 2-5 / 2-6
/ 2-16
IEC/EN 62061
EN/ISO 13849-1

10. Low power measurements IEC/EN 62301 A.

Dutch Accreditation Council RvA Page 6 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
IEC 60309-1, EN 60309-1
11. Installation Type test of installation accessories and A.
IEC 60309-2, EN 60309-2
accessories and connection devices according to the tests
IEC 60309-4 EN 60309-4
connection in the standard: IEC 60320-1, EN 60320-1
devices
- Temperature tests IEC 60320-2-1, EN 60320-2-1
(INST)
- Water and dust ingress tests IEC 60320-2-2, EN 60320-2-2
- Chemical tests IEC 60320-2-3, EN 60320-2-3
- Fire and Flammability tests IEC 60320-3, EN 60320-3
- Electric parameter tests IEC 60669-1, EN 60669-1
IEC 60669-2-1, EN 60669-2-1
- Short circuit tests
IEC 60669-2-4, EN 60669-2-4
- Dielectric properties determination
IEC 60669-2-5, EN 60669-2-5
- Endurance tests
IEC 60670, EN 60670
- Mechanical Tests
IEC 60670-1, EN 60670-1
- Isolation properties determination IEC 60670-21, EN 60670-21
IEC 60670-22, EN 60670-22
IEC 60670-23, EN 60670-23
IEC 60670-24, EN 60670-24
IEC 60884-1, EN 60884-1
IEC 60884-2-5, EN 60884-2-5
IEC 60998-1, EN 60998-1
IEC 60998-2-1, EN 60998-2-1
IEC 60998-2-2, EN 60998-2-2
IEC 60998-2-3, EN 60998-2-3
IEC 60998-2-4, EN 60998-2-4
IEC 61058-1, EN 61058-1
IEC 61534-1, EN 61534-1
IEC 61534-21, EN 61534-21
IEC 62208, EN 62208

60974, 61316, 61386, 62094


EN 50075, 50066, 50146, 50250,
50393
NEN 1251,
61238, 62080
BS 1363-1, BS 1363-2,
BS 1363-3, BS 1363-4
SS 145
BS 546, BS 4573, BS 5733
NEN 1020
NF C61-314
DIN VDE 0620-1,
DIN VDE 0620-2-1
CEI 23-50

Dutch Accreditation Council RvA Page 7 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
NBN C 61-112-1
NEK IEC 60884-1, NEK 502
ÖVE/ÖNORM E 8684-1
ÖVE/ÖNORM E 8620-2(-3,-4, -5)
SFS 5610
SS 428 08 34
DS 60884-2-D1
SEV 1011
UNE 20315-1-1;
UNE 20315-1-2
IEC/EN 61535
EN 50428 required with 60669

Dutch Accreditation Council RvA Page 8 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
IEC 60155, EN 60155
12. Luminaires Type test of luminaires according to the A.
IEC 60238, EN 60238
(LITE) tests in the standard:
IEC 60570
- Temperature tests IEC 60598-1, EN 60598-1
- Water and dust ingress tests IEC 60598-2-1, EN 60598-2-1
- Photometric tests IEC 60598-2-2, EN 60598-2-2
- Chemical tests IEC 60598-2-3, EN 60598-2-3
- Fire and Flammability tests IEC 60598-2-4, EN 60598-2-4
- Electric parameter tests IEC 60598-2-5, EN 60598-2-5
IEC 60595-2-8, EN 60598-2-8
- Short circuit tests
IEC 60598-2-10, EN 60598-2-10
- Dielectric properties determination
IEC 60598-2-11, EN 60598-2-11
- Endurance tests
IEC 60598-2-12, EN 60598-2-12
- Mechanical Tests
IEC 60598-2-13, EN 60598-2-13
- Radiation tests IEC 60598-2-19, EN 60598-2-19
- Isolation properties determination IEC 60598-2-20, EN 60598-2-20
IEC 60598-2-21, EN 60598-2-21
IEC 60598-2-22, EN 60598-2-22
IEC 60598-2-24, EN 60598-2-24
IEC 60598-2-25, EN 60598-2-25
IEC 60838-1, EN 60838-1
IEC 60838-2-2, EN 60838-2-2
IEC 60921, EN 60921
IEC 60968, EN 60968
IEC 60969, EN 60969
IEC 61347-1, EN 61347-1
IEC 61347-2-1, EN 61347-2-1
IEC 61347-2-2, EN 61347-2-2
IEC 61347-2-3, EN 61347-2-3
IEC 61347-2-7, EN 61347-2-7
IEC 61347-2-8, EN 61347-2-8
IEC 61347-2-9, EN 61347-2-9
IEC 61347-2-11, EN 61347-2-11
IEC 61347-2-12, EN 61347-2-12
IEC 61347-2-13, EN 61347-2-13
IEC 62471, EN 62471
IEC/EN 60929, 61184, 62031,
62035, 60923, 60925, 60927, 61047,
62384, 62560, 61195, 62493

CPS system for Emergency lighting EN 50171

Battery cabinet for central power supply


system for energizing emergency escape IEC/EN 62485-2
lighting

Dutch Accreditation Council RvA Page 9 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
IEC 61010-1, EN 61010-1
13. Measurement, Type test of measurement-, control- and A.
IEC 61010-2-010, EN 61010-2-010
control and laboratory equipment according to the
IEC 61010-2-030, EN 61010-2-030
laboratory tests in the standard: IEC 61010-2-040, EN 61010-2-040
equipment
IEC 61010-2-051, EN 61010-2-051
(MEAS)
- Temperature tests IEC 61010-2-081, EN 61010-2-081
- Water and dust ingress tests IEC 61010-2-091, EN 61010-2-091
- Fire and Flammability tests IEC 61010-2-101, EN 61010-2-101
- Electric parameter tests IEC 61010-2-201, EN 61010-2-201
- Short circuit tests (fault conditions) IEC 61010-031, EN 61010-031
- Dielectric properties determination
- Endurance tests
- Mechanical Tests IEC/EN 60044
- Radiation tests IEC/EN 61243
- Isolation properties determination IEEE Std C57.13

IEC 60601-1, EN 60601-1


14. Electrical Type test of electrical equipment for A.
IEC 60601-1-1, EN 60601-1-1
equipment for medical use according to the tests in the
IEC 60601-1-3, EN 60601-1-3
medical use standard: IEC 60601-1-4, EN 60601-1-4
(MED)
- Temperature tests IEC 60601-1-6, EN 60601-1-6
- Water and dust ingress tests IEC 60601-1-8, EN 60601-1-8
- Chemical tests IEC 60601-1-9, EN 60601-1-9
- Fire and Flammability tests IEC 60601-1-10, EN 60601-1-10
- Electric parameter tests IEC 60601-1-11, EN 60601-1-11
- Short circuit tests IEC 60601-2-2, EN 60601-2-2
- Dielectric properties determination IEC 60601-2-8, EN 60601-2-8
- Endurance tests IEC 60601-2-10, EN 60601-2-10
- Mechanical Tests IEC 60601-2-12, EN 60601-2-12
- Radiation tests IEC 60601-2-16, EN 60601-2-16
- Isolation properties determination IEC 60601-2-17, EN 60601-2-17
- EMC – Emission tests IEC 60601-2-18, EN 60601-2-18
- EMC – Immunity tests IEC 60601-2-19, EN 60601-2-19
IEC 60601-2-22, EN 60601-2-22
IEC 60601-2-66 & EN 60601-2-66:
IEC 60601-2-24, EN 60601-2-24
Acoustic measurements according
IEC 60601-2-25, EN 60601-2-25
subclauses 201.9.6 & 201.13.1.2 are
IEC 60601-2-26, EN 60601-2-26

Dutch Accreditation Council RvA Page 10 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
subcontracted to the DEKRA laboratory in IEC 60601-2-27, EN 60601-2-27
Malaga (Spain) IEC 60601-2-37, EN 60601-2-37
IEC 60601-2-40, EN 60601-2-40
IEC 60601-2-41, EN 60601-2-41
IEC 60601-2-46, EN 60601-2-46
IEC 60601-2-49, EN 60601-2-49
IEC 60601-2-52, EN 60601-2-52
IEC 60601-2-54, EN 60601-2-54
IEC 60601-2-57, EN 60601-2-57
IEC 60601-2-66, EN 60601-2-66
IEC 80601-2-26, EN 80601-2-26
IEC 80601-2-49, EN 80601-2-49
IEC 80601-2-58, EN 80601-2-58
IEC 80601-2-60, EN 80601-2-60

ISO 80601-2-61

IEC/EN/ISO 80601

15. Miscellaneous Type test of miscellaneous equipment IEC 60825-1, EN 60825-1 A.


equipment according to the tests in the standard: IEC 60825-2, EN 60825-2.
(MISC)
- Temperature tests
- Water and dust ingress tests
- Photometric tests
- Fire and Flammability tests
- Electric parameter tests
- Short circuit tests
- Endurance tests
- Isolation properties determination

IEC 60950-1, EN 60950-1


16. IT and office Type test of IT and office equipment A.
IEC 60950-22, EN 60950-22
equipment according to the tests in the standard:
IEC 62040-1, EN 62040-1
(OFF)
- Temperature tests
IEC/EN 60825
- Water and dust ingress tests
IEC 62368
- Fire and Flammability tests
EN 41003
- Electric parameter tests
- Short circuit tests (fault conditions)
- Dielectric properties determination
- Endurance tests
- Mechanical Tests
- Radiation tests
- Isolation properties determination

Dutch Accreditation Council RvA Page 11 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
IEC 61439, EN 61439
17. Low voltage, high Type test of low voltage, high power A.
IEC 60439-2, EN 60439-2
power switching switching equipment according to the
IEC 60439-3, EN 60439-3
equipment tests in the standard: IEC 60439-4, EN 60439-4
(POW)
- Temperature tests IEC 60439-5, EN 60439-5
- Water and dust ingress tests IEC 60439-6, EN 60439-6
- Chemical tests IEC 60947-2, EN 60947-2
- Fire and Flammability tests IEC 60947-3, EN 60947-3
- Electric parameter tests IEC 60947-4-1, EN 60947-4-1
- Short circuit tests IEC 60947-4-2, EN 60947-4-2
- Dielectric properties determination IEC 60947-4-3, EN 60947-4-3
- Endurance tests IEC 60947-5-1, EN 60947-5-1
- Mechanical Tests IEC 60947-6-1, EN 60947-6-1
- Isolation properties determination IEC 60947-6-2, EN 60947-6-2
- EMC – Emission tests IEC 60947-7-1, EN 60947-7-1
- EMC – Immunity tests IEC 60947-7-2, EN 60947-7-2
- EMC – Radiation test IEC 60947-7-3, EN 60947-7-3
IEC 60947-7-4, EN 60947-7-4

IEC/EN 60282, 62208


EN 50178, IEC 60470, 60549,
60644, EN 60282-1
IEEE Std C37.41, C37.60
ANSI C37.44
IEC 61921

Dutch Accreditation Council RvA Page 12 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product

18. Installation Type test of installation protective IEC/EN 60755, 62019 A.


protective equipment according to the tests in the
equipment standard: IEC 60529
(PROT)
- Temperature tests IEC 60127-6, EN 60127-6
- Water and dust ingress tests IEC 60269-3, EN 60269-3
- Fire and Flammability tests IEC 60898-1, EN 60898-1
- Electric parameter tests IEC 60898-2, EN 60898-2
- Short circuit tests IEC 61008-1, EN 61008-1
- Dielectric properties determination IEC 61008-2-1, EN 61008-2-1
- Endurance tests IEC 61009-1, EN 61009-1
- Mechanical Tests IEC 61009-2-1, EN 61009-2-1
- Isolation properties determination IEC 61009-2-2, EN 61009-2-2
- EMC – Emission tests IEC 61643-11, EN 61643-11
- EMC – Immunity tests IEC 61643-31, EN 61643-31
- EMC – Radiation tests
IEC 60099, 60137, 60168, 60383,
60507, 60660, 61109, 60815
HD 630, 639, 60269
IEEE Std 62.11
ANSI C29
CAN/CSA C411.1

19. Installation Type test of installation protective IEC/EN 60755, 62019 A.


protective equipment according to the tests in the
equipment standard: IEC 60529
(PROT)
- Temperature tests IEC 60127-6, EN 60127-6
- Water and dust ingress tests IEC 60269-3, EN 60269-3
- Fire and Flammability tests IEC 60898-1, EN 60898-1
- Electric parameter tests IEC 60898-2, EN 60898-2
- Short circuit tests IEC 61008-1, EN 61008-1
- Dielectric properties determination IEC 61008-2-1, EN 61008-2-1
- Endurance tests IEC 61009-1, EN 61009-1
- Mechanical Tests IEC 61009-2-1, EN 61009-2-1
- Isolation properties determination IEC 61009-2-2, EN 61009-2-2
- EMC – Emission tests IEC 61643-11, EN 61643-11
- EMC – Immunity tests IEC 61643-31, EN 61643-31
- EMC – Radiation tests

IEC 60099, 60137, 60168, 60383,


60507, 60660, 61109, 60815
HD 630, 639, 60269
IEEE Std 62.11
ANSI C29
CAN/CSA C411.1

Dutch Accreditation Council RvA Page 13 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
IEC 61869-1, EN 61869-1
20. Safety Type test of safety transformers and A.
IEC 61869-2, EN 61869-2
transformers and simillar equipment according to the tests
IEC 61558-1, EN 61558-1
similar equipment in the standard: IEC 61558-2-1, EN 61558-2-1
(SAFE)
Temperature tests IEC 61558-2-4, EN 61558-2-4
- Water and dust ingress tests IEC 61558-2-5, EN 61558-2-5
- Fire and Flammability tests IEC 61558-2-6, EN 61558-2-6
- Electric parameter tests IEC 61558-2-7, EN 61558-2-7
- Short circuit tests IEC 61558-2-8, EN 61558-2-8
- Dielectric properties determination IEC 61558-2-13, EN 61558-2-13
- Endurance tests IEC 61558-2-15, EN 61558-2-15
- Mechanical Tests IEC 61558-2-16, EN 61558-2-16
- Isolation properties determination

IEC/EN 62040,
IEC/EN 60076, IEC/EN 60353
EN 50091, EN 50464-1
HD 538.1
IEEE Std. C57.12.90, C57.21
NEMA 107
CISPR 16

Type test according to the tests as


21. Electronics, IEC 60065, EN 60065 A.
mentioned in the standard, except the
entertainment following tests which are subcontracted:
equipment - Temperature tests IEC / EN 60491
(TRON) - Water and dust ingress tests IEC 62368
- Chemical tests
- Fire and Flammability tests
- Electric parameter tests
- Short circuit tests
- Dielectric properties determination
- Endurance tests
- Mechanical Tests
- Radiation tests
- Isolation properties determination

Except the following tests which are


subcontracted:

60065, cl. 20.1.3 Pre-conditioning of


printed circuit boards
60065, cl. 12.1.2 Vibration-sine

Dutch Accreditation Council RvA Page 14 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product

Photometric Tests
(all tests are in accordance with the reference method)

22. Headlamps low All tests as mentioned in the ECE ECE Regulations Nos. 1, 5, 8, 19, A.
and high beams Regulations stated under Test method¹ 20, 31, 56, 57, 72, 76, 82, 98, 112,
and front fog 113, 123, 149;
lamps Photometry European Directives 76/761, 76/762
Colorimetry and 97/24
Heat tests
Plastic tests
All tests as mentioned in de FMVSS, FMVSS108 (49CFR 571.108);
23. Headlamps low CMVSS 108, 108.1, 1201; A.
CMVSS and SAE (methods)
and high beams SAE J578, J581, J582, J583,
and front fog J591, J852, J1383, J1735,
lamps Photometry J2595;
Colorimetry
SAE (Methods) J575, J2139, J1889,
J2650, J1306, J1623

24. Signalling lamps All tests as mentioned in the ECE ECE Regulations Nos. 6, 7, 23, 38, A.
Regulations stated under Test method 50, 77, 87, 91, 148 and European
Directives 76/757, 76/759, 76/758,
Photometry 77/538, 77/539, 77/540 and 97/24
Colorimetry ECE Regulation 38 (rear fog lamps
Heat test only)

25. All tests as mentioned in de FMVSS, FMVSS108 (49CFR 571.108); A.


CMVSS and SAE(methods) CMVSS 108, 108.1, 1201;
SAE J222, J578, J585, J586, J587,
Photometry J588, J592, J593, J914, J1319,
Colorimetry J1373, J1395, J1398, J1424, J1432,
J1957, J2039, J2040, J2042, J2087,
J2261, J131, J584;

26. Devices for the All tests as mentioned in the ECE ECE Regulations Nos. 4, 50, 148 A.
illumination of Regulations stated under Test method European Directives 76/760 and
rear registration Luminance 97/24
plates Colorimetry
All tests as mentioned in de FMVSS, FMVSS 108 (49 CFR 571.108);
27. CMVSS 108; A.
CMVSS and SAE (methods)
Luminance SAE J578, J587;
Colorimetry

Dutch Accreditation Council RvA Page 15 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product

28. Retro-reflective All tests as mentioned in the ECE ECE Regulations Nos. 3, 69, 70, 88, A.
devices Regulations stated under Test method² 104, 150
European Directive 76/757
excluding Retro-reflection
advance-warning Colorimetry
triangles Water resistance test
Corrosion
Fuel and oil resistance
Heat test
UV resistance
All tests as mentioned in de FMVSS, FMVSS 108 (49 CFR 571.108),
29. CMVSS 108, 108.1, A.
CMVSS and SAE (methods)
Retro-reflection SAE J578, J594, J774, J1967, J2041
Colorimetry

30. Light Sources All tests as mentioned in the ECE ECE Regulations Nos. 37, 99 A.
Regulations stated under Test method IEC 60809
IEC 60810
Geometry IEC 60983
Photometry
Colorimetry IEC 60061
Optical quality
Mechanical tests

31. Special warning All tests as mentioned in the ECE ECE Regulation No. 65 A.
lamps (beacons Regulations stated under Test method
and flash lights)
Photometry
Colorimetry
Water resistance test

32. Cornering Lamps All tests as mentioned in the ECE ECE Regulation No.119, 149 A.
Regulations stated under Test method
Photometry
Colorimetry

33. All tests as mentioned in de FMVSS, FMVSS108 (49CFR 571.108); A.


CMVSS and SAE (methods) CMVSS 108, 108.1, 1201;
SAE J578, J852
Photometry SAE (Methods) J575, J2139, J1889,
Colorimetry J2650, J1306, J1623;

Dutch Accreditation Council RvA Page 16 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product

34. Non-directional Electrical and Photometric Measurements IES LM-79 A.


Solid State of Solid-State Lighting Products (section
Luminaires and 10 not required for non-directional or
Subcomponents subcomponents):
- Efficacy,
- Light Output,
- Lumen Maintenance,
- CCT, CRI,
- Color Maintenance

35. Non-directional Characterization of LED Light Engines IES LM-82 A.


Solid State and LED Lamps for Electrical and
Luminaires and Photometric Properties as a Function of:
Subcomponents - Temperature,
-Efficacy,
- Light Output,
- Lumen Maintenance,
- CCT , CRI,
- Color Maintenance,
- Light Source Life

36. LED Directional Electrical and Photometric Measurements IES LM-79 A.


Lamps of Solid-State Lighting Products,
- Efficacy, (excluding par. 9.3, 10.0 en 12.5)
- Light Output,
-Lumen Maintenance,
- Lifetime,
- CCT, CRI,
- Color Maintenance

37. LED Electrical and Photometric Measurements IES LM-79 A.


Omnidirectional of Solid-State Lighting Products,
and Decorative - Efficacy, (excluding par. 9.3, 10.0 en 12.5)
Lamps - Light Output,
-Lumen Maintenance,
- Lifetime,
- CCT, CRI,
- Color Maintenance
IES LM-79
38. All Lamps (Light - Efficacy, A.
Bulbs) - Light Output,
- Lumen Maintenance,
- CCT, CRI,
- Color Maintenance

Dutch Accreditation Council RvA Page 17 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
IES LM-79
39. All Luminaire and - Efficacy, A.
IES LM-82
Subcomponents - Light Output,
- Lumen Maintenance,
- CCT, CRI,
- Color Maintenance

Radio Testing
Radio transmitters Carrier/Operating frequency/Permitted
40. 2231, 2232, 2230 A.
and receivers Range of operating frequencies
10 Hz – 40 GHz
Unwanted emissions in the spurious 2231, 2232, 2229, 2238, 2230,
41. A.
domain (Transmitter/Receiver) 2235, 2860
9 KHz – 40 GHz
FCC (2226, 2227, 2228, 2233,
2234, 2236)
TX effective radiated power/RF Output 2232, 2229, 2238, 2230,
42. A.
Power,
FCC (2226, 2227, 2228, 2233,
10 nW – 2 W @ 10 Hz – 40 GHz 2234, 2236)
TX Maximum e.r.p. power spectral 2232, 2229, 2238,
43. A.
density,
FCC (2226, 2227, 2228, 2233,
10 nW/MHz – 2 W/MHz @ 10 Hz – 40 2234)
GHz
6dB/20dB/26dB/99%/Occupied/Nominal/B 2231, 2232, 2229, 2238,
44. A.
andwidth/Modulation bandwidth FCC (2226, 2227, 2228, 2233,
10 Hz – 40 GHz 2234, 2236)

Duty cycle, Tx-Sequence,Tx-gap


45. 2229, 2238, 2230 A.
Up to 100% @ 10 Hz – 40 GHz
Frequency error, 2229,
46. A.
-40 to + 60 oC FCC (2226, 2227, 2228, 2233,
2234)
TX out of band emissions,
47. 2232, 2229, 2238 A.
9 KHz – 40 GHz
TX Transient power,
48. 2229 A.
10 nW – 2 W @ 10 Hz – 40 GHz

Dutch Accreditation Council RvA Page 18 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
TX Adjacent channel power,
49. 2229 A.
10 nW – 2 W @ 10 Hz – 40 GHz

50. TX behaviour under low voltage 2229 A.


conditions

51. TX Adaptive power control 2229 A.


2229, 2238,
52. TX FHSS , Accumulated Transmit time, A.
Frequency Occupation & Hopping FCC (2226, 2227, 2228, 2233,
Sequence, Hopping Frequency 2234)
Separation

53. TX short term behavior 2229 A.


RX Sensitivity level,
54. 2229 A.
-150 dBm – 30 dBm

55. Clear channel assessment threshold 2229 A.

56. Polite spectrum access/timing 2229 A.

57. Adaptive Frequency agility 2229 A.

58. Behavior at high wanted signal level 2229 A.


Receiver Blocking or decentralization
59. 2231, 2232, 2229, 2238, 2230 A.
9 kHz to 6 GHz

60. Medium Utilization 2238 A.


Adaptivity,
61. 2232, 2238 A.
9 kHz to 6 GHz

62. Geo-location capability 2232, 2238 A.

63. User Access Restrictions 2232 A.


Transmitter H-field requirements,
64. 2231 A.
9 KHz – 30 MHz
Transmitter RF carrier current,
65. 2231 A.
9 KHz – 135 KHz
Transmitter radiated E-field,
66. 2231 A.
9 KHz – 30 MHz

Dutch Accreditation Council RvA Page 19 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
Transmitter Frequency Stability
67. 2231 A.

Adjacent channel selectivity,


68. 2231, 2230 A.
0 dB to -80 dB @ 9 kHz – 6 GHz

69. Spectrum access Techniques 2230 A.

70. Transmit Power Control (TPC) 2232 A.

71. Band Edge (Low/High) FCC (2226, 2227, 2228, 2233, A.


2234)
Field strength of emissions within the
72. FCC (2226, 2227, 2228, 2233, A.
band
2234)
9 kHz – 40 GHz
Field strength of emissions outside of the
73. FCC (2226, 2227, 2228, 2233, A.
band,
2234)
9 kHz – 40 GHz

74. Frequency tolerance of the carrier signal FCC (2226, 2227, 2228, 2233, A.
2234)
2230,
75. Number of hopping channels and Dwell A.
time FCC (2226, 2227, 2228, 2233,
2234)

76. Frequency Stability 2236 A.

77. Carrier Frequency Separation FCC (2226, 2227, 2228, 2233, A.


2234)
RF exposure evaluation, EN/IEC 62311,
78. A.
EN/IEC 62479,
0 Hz to 300 GHz 47 CFR § 2.1091,
47 CFR § 2.1093,
RSS-102
Dynamic Frequency Selection (DFS), 2232,
79. A.
10 Hz to 6 GHz FCC (2226, 2227, 2228, 2233,
2234)

Dutch Accreditation Council RvA Page 20 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
DFS Tests: Channel Availability Check, 2232,
80. A.
Off-Channel CAC – Radar Detection
FCC (2226, 2227, 2228, 2233,
Threshold Level, Off-Channel CAC –
Detection Probability, In service 2234)
Monitoring, Channel shutdown, Non-
occupancy period, Uniform spreading,
DFS U-NII Detection bandwidth, Statrical
performance check
10 Hz to 6 GHz

81. TX In-band emissions 2232 A.

Electromagnetic Compatibility (EMC) - Emission (EMC.E)


Test object
Type of test
Code Method / Reference documents Location
or product
Conducted Emissions,
EMC. Electric and Voltage method (AN), EN 55025 (CISPR 25) A.
E.01 electronic
equipment
100 KHz - 108 MHz
Conducted Emissions EN 55011 (CISPR 11),
EMC. Electric and Voltage method (AMN), EN 55013 (CISPR 13), A.
E.02 electronic EN 55014-1 (CISPR 14-1),
equipment EN 55015 (CISPR 15),
9 KHz - 30 MHz EN 55016-1-2 (CISPR 16-1-2),
EN 55016-2-1 (CISPR 16-2-1),
EN 55022 (CISPR 22),
EN 55025 (CISPR 25),
EN 55032 (CISPR 32),
EN/IEC 60945, ANSI C63.4, MP5-
1986,
CAN/CSA-CEI/IEC CISPR 11-04,
CAN/CSA-CISPR 22-10
Conducted Emissions EN 55011 (CISPR 11),
EMC. Electric and Voltage method (LISN), EN 55013 (CISPR 13), A.
E.03 electronic EN 55014-1 (CISPR 14-1),
equipment 9 KHz - 30 MHz EN 55015 (CISPR 15),
EN 55016-1-2 (CISPR 16-1-2),
EN 55016-2-1 (CISPR 16-2-1),
EN 55022 (CISPR 22),
EN 55025 (CISPR 25),
EN 55032 (CISPR 32),
EN/IEC 60945, ANSI C63.4, MP5-
1986,
CAN/CSA-CEI/IEC CISPR 11-04,
CAN/CSA-CISPR 22-10

Dutch Accreditation Council RvA Page 21 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
Conducted Emissions, EN 55011 (CISPR 11),
EMC. Electric and Voltage method EN 55013 (CISPR 13), A.
E.04 electronic (Voltage probe) EN 55014-1 (CISPR 14-1),
equipment EN 55015 (CISPR 15),
9 KHz - 30 MHz EN 55016-1-2 (CISPR 16-1-2),
EN 55016-2-1 (CISPR 16-2-1),
EN 55022 (CISPR 22),
EN 55032 (CISPR 32),
ANSI C63.4, MP5-1986,
CAN/CSA-CEI/IEC CISPR 11-04,
CAN/CSA-CISPR 22-10
Conducted Emissions, EN 55011 (CISPR 11),
EMC. Electric and Current method (Current probe) EN 55013 (CISPR 13), A.
E.05 electronic EN 55014-1 (CISPR 14-1),
equipment 100 KHz - 250 MHz EN 55015 (CISPR 15),
EN 55016-1-2 (CISPR 16-1-2),
EN 55016-2-1 (CISPR 16-2-1),
EN 55022 (CISPR 22),
EN 55025 (CISPR 25),
EN 55032 (CISPR 32)
Conducted Emissions, EN 55013 (CISPR 13),
EMC. Electric and Power disturbance method (Absorbing clamp) EN 55014-1 (CISPR 14-1), A.
E.06 electronic EN 55016-1-3 (CISPR 16-1-3),
equipment 30 MHz - 1000 MHz EN 55016-2-2 (CISPR 16-2-2),
EN 55032 (CISPR 32)
Conducted Emissions,
EMC. Electric and Discontinuous disturbance EN 55014-1 (CISPR 14-1) A.
E.09 electronic
equipment 9 KHz - 30 MHz
Radiated Emissions EN 55011 (CISPR 11),
EMC. Electric and Semi Anechoic Chamber Method (SACM) EN 55012 (CISPR 12), A.
E.15 electronic EN 55013 (CISPR 13),
equipment 150 KHz - 40 GHz EN 55014-1 (CISPR 14-1),
EN 55015 (CISPR 15),
EN 55016-1-4 (CISPR 16-1-4),
EN 55016-2-3 (CISPR 16-2-3),
EN 55022 (CISPR 22),
EN 55025 (CISPR 25),
EN 55032 (CISPR 32),
EN/IEC 60945; FCC Part 15,
FCC Part 18, ANSI C63.4, MP5-
1986,
CAN/CSA-CEI/IEC CISPR 11-04,
CAN/CSA-CISPR 22-10

Dutch Accreditation Council RvA Page 22 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
Radiated Emissions EN 55011 (CISPR 11),
EMC. Electric and Open Area Test Site (OATS) EN 55012 (CISPR 12), A.
E.16 electronic 150 KHz - 1 GHz EN 55013 (CISPR 13),
equipment EN 55014-1 (CISPR 14-1),
EN 55015 (CISPR 15),
EN 55016-1-4 (CISPR 16-1-4),
EN 55016-2-3 (CISPR 16-2-3),
EN 55022 (CISPR 22),
EN 55025 (CISPR 25),
EN 55032 (CISPR 32),
EN/IEC 60945; FCC Part 15,
FCC Part 18, ANSI C63.4, MP5-
1986,
CAN/CSA-CEI/IEC CISPR 11-04,
CAN/CSA-CISPR 22-10
Radiated Emissions, EN 55011 (CISPR 11),
EMC. Electric and Large Loop Antenna System (LLAS) EN 55015 (CISPR 15), A.
E.18 electronic EN 55016-1-4 (CISPR 16-1-4),
equipment 9 KHz - 30 MHz EN 55016-2-3 (CISPR 16-2-3)
Radiated Emissions, EN 55011 (CISPR 11),
EMC. Electric and 60 cm loop method EN 55016-1-4 (CISPR 16-1-4), A.
E.20 electronic EN 55016-2-3 (CISPR 16-2-3),
equipment 9 KHz - 30 MHz EN/IEC 60945
FCC Part 15, FCC Part 18,
ANSI C63.4, MP5-1986,
CAN/CSA-CEI/IEC CISPR 11-04
Radiated Emissions, EN/IEC 61851-21-2
EMC. Electric and Magnetic field (Annex B) A.
E.22 electronic
equipment 2 kHz – 185 kHz
Harmonic Current Emissions, EN/IEC 61000-3-2
EMC. Electric and (Up to and including 16A per phase) A.
E.26 electronic
equipment 1 and 3 phase

EMC. Electric and Voltage changes, voltage fluctuations and EN/IEC 61000-3-3 A.
E.27 electronic flicker Emissions,
(Up to and including 16A per phase)
equipment
1 and 3 phase
50/60 Hz
EMC. Electric and Magnetic effect Emissions, EN/IEC 60945, EN ISO 694 A.
E.28 electronic Compass safe distance
equipment
DC
EMC. Electric and Harmonic Current Emissions, EN/IEC 61000-3-12 A.
E.29 electronic (> 16A per phase)
equipment
1 and 3 phase

Dutch Accreditation Council RvA Page 23 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
EMC. Electric and Voltage changes, voltage fluctuations and EN/IEC 61000-3-11 A.
E.30 electronic flicker Emissions
equipment (> 16A per phase)

1 and 3 phase
50/60 Hz
EMC. Electric and Pulse emission for ESA’s ISO 7637-1, A.
E.31 electronic along supply lines 12V and 24V ISO 7637-2
equipment

EMC. Electric and Radio disturbances EN 55025 (CISPR 25) A.


E.33 electronic (ALSE method)
equipment
150 kHz – 2500 MHz
Conducted Emissions, EN 55013 (CISPR 13),
EMC. Electric and Voltage method EN 55014-1 (CISPR 14-1), A.
E.34 electronic (AAN method) EN 55015 (CISPR 15),
equipment EN 55016-1-2 (CISPR 16-1-2),
150 KHz - 30 MHz EN 55016-2-1 (CISPR 16-2-1),
EN 55022 (CISPR 22),
EN 55032 (CISPR 32)

Electromagnetic Compatibility Immunity/Susceptability (EMI)


Test object
Type of test
Code Method / Reference documents
or product

Electric and Conducted RF Immunity, Electromagnetic, A.


EMC.
electronic EN/IEC 61000-4-6
I.01 up to 30 Vrms
equipment 150 KHz to 230 MHz

Conducted RF Immunity
A.
Electric and Bulk Current Injection method ISO 11451-1, ISO 11451-4,
EMC. ISO 11452-1, ISO 11452-4
electronic
I.02 up to 200 mA,
equipment
1 MHz – 400 MHz

Harmonics and interharmonics including mains


Electric and signaling at a.c. power port, low frequency EN/IEC 61000-4-13, A.
EMC.
electronic immunity EN/IEC 61000-2-2
I.03
equipment
16.5 Hz – 3000 Hz
Immunity to conducted disturbances, Common
mode A.
Electric and
EMC.
electronic DC - 150 KHz up to 30 V EN/IEC 61000-4-16
I.08 DC, 162/3, 50, 60 Hz
equipment
Continuous: up to 30 V
Short duration: up to 300 V

Dutch Accreditation Council RvA Page 24 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product

Electric and Electrostatic discharge Immunity (ESD) A.


EMC. EN/IEC 61000-4-2,
electronic ISO 10605
I.21 Contact discharge: up to 15 kV,
equipment Air discharge: up to 30 kV

Electric and Electrical fast transient / burst Immunity (EFT), A.


EMC.
electronic EN/IEC 61000-4-4
I.22 1 and 3 phase
equipment 0,25 kV - 4 kV

Electric and Surge Immunity, A.


EMC.
electronic EN/IEC 61000-4-5
I.23 1-phase up to 10,0 kV
equipment 3-phase up to 4,0 kV

Electric and Power frequency magnetic field Immunity A.


EMC.
electronic EN/IEC 61000-4-8
I.24 50/60 Hz
equipment 1 – 1500 A/m

Electric and Pulsed magnetic field Immunity A.


EMC.
electronic EN/IEC 61000-4-9
I.25 1 - 5000 A/m
equipment
Voltage dips, short interruptions and voltage
Electric and variations Immunity EN/IEC 61000-4-11, A.
EMC.
electronic EN/IEC 61000-4-34
I.26 1 and 3 phase
equipment
0 - 360 Angle(s)
Electric transient transmission via lines other
Electric and than supply lines Immunity ISO 7637-1,
A.
EMC.
electronic ISO 7637-3
I.27 600 V
equipment
RF (fixed)

Electric and DC voltage ripple Immunity EN/IEC 61000-4-17 A.


EMC.
electronic
I.30 16,5 Hz – 1000 Hz
equipment

Electric and Supply frequency variations Immunity A.


EMC.
electronic EN/IEC 61000-4-28
I.32 16,5 Hz- 400 Hz
equipment

Electric and Ring wave immunity test A.


EMC.
electronic EN/IEC 61000-4-12
I.36 1 and 3 phase
equipment up to 4 kV
DC Voltage dips, short interruptions and
Electric and voltage variations Immunity A.
EMC.
electronic EN/IEC 61000-4-29
I.37 360 Vdc
equipment
40 A

Dutch Accreditation Council RvA Page 25 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product

Electric and ISO 7637-1, A.


EMC. Electric transient transmission along supply
electronic ISO 7637-2
I.39 lines Immunity
equipment
Radiated Immunity,
EMC. Electric and Semi Anechoic Chamber method EN/IEC 61000-4-3, A.
I.41 electronic ISO 11451-1, ISO 11451-2,
equipment 20 MHz to 150 MHz up to 30 V/m ISO 11452-1, ISO 11452-2
150 MHz to 6 GHz up to 200 V/m
Radiated Radio Frequency Susceptibility
EMC. Electric and
Open Area Test Site (OATS) ISO 11451-1, ISO 11451-2, A.
I.43 electronic ISO 11452-1, ISO 11452-2
equipment 20 MHz to 6 GHz up to 30 V/m
Unbalance, immunity test
A.
Electric and
EMC. 1 and 3 phase
electronic EN/IEC 61000-4-27
I.46 50/60 Hz
equipment
UN ± 50 %
0°, 120° and 240° ± 30°
Voltage fluctuation immunity test
Electric and A.
EMC.
electronic 1 and 3 phase EN/IEC 61000-4-14
I.47
equipment 50/60 Hz
ΔU = ±12 % Un
An objective light flickermeter and voltage
fluctuation immunity test
A.
Electric and
EMC.
electronic IEC/TR 61547-1
I.48 1 and 3 phase
equipment
50/60 Hz
39 – 4800 cpm

Electromagnetic Compatibility (EMC) - Electromagnetic Fields (EMC.F)


Test object
Type of test
Code Method / Reference documents
or product

Electric and Magnetic flux density A.


EMC.
electronic EN/IEC 62493
F.01 20 KHz – 300 MHz
equipment

Electric and Magnetic flux density A.


EMC. EN/IEC 62233
electronic
F.01 0 – 400 KHz
equipment

Product standards containing one or more of the above mentioned test activities are listed below.
Accreditation is only applicable to the tests mentioned above.

Dutch Accreditation Council RvA Page 26 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product

Electromagnetic Compatibility (EMC) scheme (EMC.S)


EMC.E.01; EMC.E.02; EMC.E.03; EMC.E.04; UN ECE Regulation 10,
EMC. Automotive EMC EMC.E.05; EMC.E.15; EMC.E.16; EMC.E.26; 2004/104/EC, A.
S.02 tests EMC.E.27; EMC.E.29; EMC.E.30; EMC.E.31; EN 55012 (CISPR 12),
EMC.E.33; EMC.E.34; EN 55025 (CISPR 25,
EN 50498, EN 12895,
EMC.I.02; EMC.I.22; EMC.I.23; EMC.I.39;
EMC.I.41; EMC.I.43 ISO/EN 14982 (Machinery)
EMC.E.01; EMC.E.02; EMC.E.03; EMC.E.04; EN 55014-1, CISPR 14-1,
EMC. Electrical and EMC.E.05; EMC.E.06; EMC.E.09; EMC.E.15; EN 55014-2, CISPR 14-2,
A.
S.03 electronic EMC.E.16; EMC.E.18; EMC.E.20; ; EMC.E.22; EN/IEC 60945 (EMC requirements),
equipment EMC EMC.E.26; EMC.E.27; EMC.E.28; EMC.E.29;
EN/IEC 61000-6-1,
tests EMC.E.30; EMC.E.31; EMC.E.33; EMC.E.34
EN/IEC 61000-6-2,
EMC.I.01; EMC.I.02; EMC.I.03; EMC.I.08;
EMC.I.21; EMC.I.22; EMC.I.23; EMC.I.24;
EMC.I.25; EMC.I.26; EMC.I.27; EMC.I.30;
EMC.I.32; EMC.I.36; EMC.I.37; EMC.I.39; EN/IEC 61000-6-3,
EMC.I.41; EMC.I.43; EMC.I.46; EMC.I.47; EN/IEC 61000-6-4,
EMC.I.48
EN 50121-1, EN 50121-2,
EN 50132-3-1, EN 50121-3-2,
EN 50121-4, EN 50121-5,
EN/IEC 61204-3, EN 50293,
EN 55015 (CISPR 15),
IEC/TR 61547-1
EN 55022 (CISPR 22), EN 55024
(CISPR 24), EN 55032 (CISPR 32),
EN 55035 (CISPR 35), EN 55013
(CISPR 13), EN 55020 (CISPR 20),
EN/IEC 60601-1-2,
EN/IEC 60601-2-X,
EN/IEC 60730-1,
EN/IEC 60730-2-X (EMC-
requirements),
EN/IEC 62040-2,
EN/IEC 61326-1, EN/IEC 61326-2-X,
EN/IEC 60947-X (EMC-
requirements)

EN 50130-4, EN 301 489-1,


EN 301 489-3, EN 301 489-17,
EN 301 489-19, EN 301 489-52,
EN 50428, EN/IEC 60669-2-X,
EN 50270,
EN 15194 (EMC requirements),
EN/IEC 61000-6-7,
EN/IEC 61326-3-1,
EN 50491-5-1, EN 50491-5-2,

Dutch Accreditation Council RvA Page 27 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
EN 50491-5-3, EN/IEC 63044-5-1,

EN/IEC 63044-5-2,
EN/IEC 63044-5-3
EN/IEC 61851-22,
EN/IEC 61851-21-2

Lloyds Regulations (Germanischer


Lloyds, DNV-GL, Lloyd’s Registers,
Bureau Veritas), EMC requirements
EMC.E.02; EMC.E.03; EMC.E.04; EMC.E.15;
EMC. FCC (Federal EMC.E.16 FCC Part 15, FCC Part 18 A.
S.05 Communications
Commission) EMC
tests
EMC.E.02; EMC.E.03; EMC.E.04; EMC.E.15; ICES-001, ICES-003 A.
EMC. ISED EMC tests EMC.E.16
S.07

Radio Product Standards

Material or
Internal reference number Method / Reference documents
product
Test numbers 39, 40, 41, 44, 59, 64, 65, 66, 67
a. Short range and 68 ETSI EN 300 330 A.
devices; Radio
equipment in the
frequency range 9
kHz to 25 MHz and
inductive loop
systems in the
frequency range 9
kHz to 30 MHz
Test numbers 39, 40, 41, 42, 43, 44, 47, 59,
b. Broadband Radio 61, 62, 63, 70, 79, 80 and 81 ETSI EN 301 893 A.
Access Networks
(BRAN); 5 GHz high
performance RLAN
Short Range Test numbers 39 up to and including 59
c. Devices (SRD) ETSI EN 300 220-1, ETSI EN 300 A.
operating 220-2

in the frequency
range 25 MHz to 1
000 MHz;

Dutch Accreditation Council RvA Page 28 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
Test numbers 39, 40, 41, 42, 43, 44, 45, 47,
d. Wideband 52, 59, 60, 61 and 62 ETSI EN 300 328 A.
transmission
systems; Data
transmission
equipment
operating in the 2,4
GHz band;
Short Range Test numbers 39, 40, 41, 42, 45, 59, 68, 69
e. Devices (SRD); and 75 ETSI EN 300 440 A.
Radio equipment to
be used in
the 1 GHz to 40
GHz frequency
range;
Test number 40
f. Global System for ETSI EN 301 511 A.
Mobile
communications
(GSM); Mobile
Stations (MS)
equipment;
Test number 40
g. IMT cellular ETSI EN 301 908-1 A.
networks;
Electrical and Test numbers 39, 40, 41, 42, 43, 44, 46, 52,
h. Electronic 71, 72, 73, 74, 75, 77, 79 and 80 FCC CFR 47 Part 15, Subpart C, A.
Equipment 15.209, 15.225, 15.231, 15.247,
(Including: (Fire) 15.407
Alarm systems,
Telecommunication ISED RSS-Gen, 210, 247
Terminal
Equipment,
Maritime
Communication and
Navigation
Equipment and
Radio Transmitters
and Receivers)

Dutch Accreditation Council RvA Page 29 of 30


Annex to declaration of accreditation (scope of accreditation)
Normative document: EN ISO/IEC 17025:2017
Registration number: L 022

of DEKRA Certification B.V.

This annex is valid from: 06-07-2022 to 01-05-2026 Replaces annex dated: 29-06-2022

No. Material or Type of activity1 Internal reference number Location


product
Electrical and Test numbers 39, 40, 41, 42, 44 and 76
i. Electronic FCC CFR 47 Part 22, 24, 27 A.
Equipment
(Including: (Fire) ISED RSS 130, 132-134, 139, 199,
Alarm systems,
Telecommunication
Terminal
Equipment,
Maritime
Communication and
Navigation
Equipment and
Radio Transmitters
and Receivers)
Satellite Earth Test number 40
j. Stations and ETSI EN 303 413 A
Systems (SES);
Global Navigation
Satellite System
(GNSS) receivers

The accreditation for the activities below is suitable for notification

European construction products regulation No 305/2011

System 3 Verification of Constancy of Performance

Product area 31:Power, control and communication cables

Decision 2011/284/EC
Power, control and EN 50575:2014+A01:2016
communication cables

81 Power, control Flame spread test EN 503992


and
communication
cables2
Test for vertical flame propagation EN 60332-1-22

Determination of acidity (by pH EN 60754-22


measurement) and conductivity

Reaction to fire classification (D) and (E) EN 13501-62

¹ Weather-beaten tests of synthetic lenses is subcontracted


² Use of facilities outside the test laboratory of the accredited organisation

Dutch Accreditation Council RvA Page 30 of 30