Product Sheet 1028
Autoclimate Ltd
Unit 37, Atcham Business Park
Atcham, Nr Shrewsbury
Shropshire SY4 4UG
Tel: +44 (0)1743 445566
Fax: +44 (0)1743 464646
ROBINAIR AC690 Pro
Part No.: 2404-116
Date: 26 March 2008
Introduction Issue: 0.3
AC690 - is the most advanced AC service station for car, truck and bus. Fully SPECIFICATION
automatic and user friendly it has been developed for use on all Automotive R134a Voltage: 220-240v AC 50 Hz
air conditioning systems with the minimum of user intervention possible. The AC690 Refrigerants: R134A
automatically controls the recovery, recycling, vacuum and recharging process for Weight: 110kg
the oil, UV dye and refrigerant without the need for the operator. It can also be used Dimensions: 128cm x 69 cm x 69 cm
in manual mode to control each phase independently. The powerful dual stage Max. Operating
vacuum pump guarantees a rapid and effective dehydration of the system prior to Pressure: 16 bar (232 PSI)
recharging. The unit is equipped with an integrated database supplying the details Temp. Operating
of 3900 vehicles for refrigerant, oil type and quantity required, which can be used Range: 10 - 50ºC
in conjunction with the built vehicle fault diagnostic program. The standard fitted Warranty: 12 months (optional 3 year extended
warranty available)
printer gives an overall detailed activity report at the end of the automatic process,
or at the end of each process when used in manual mode.
Complete Automation
The AC690 Pro offers complete “programme and walk away” capability. This
is achieved with two additional scales which firstly, weigh recovered oil and
automatically injects the same amount of fresh oil plus any extra oil if required. UV
dye injection is also automatic when selected.
Automatic Operation / Vehicle Database
The user can run either in “manual” or “automatic” (expert or beginner) mode for
maximum flexibility. “Automatic” option reduces “hands on” time to around 5 minutes
per job (with automatic leak check) and allows you to select “make”, “model” & “type”
of vehicle (from the 3,900 available on the OEM database). Refrigerant charge, oil
viscosity and quantity are then displayed and confirmed. The database now has full
edit and key up-date facilities.
Unique Diagnostic Programme
The integrated diagnostic programme is extremely powerful. From key temperature
and pressure data the programme diagnoses possible faults and rectifications,
saving time and improving service levels. This functionality replicates expensive
stand-alone “A/C fault-finding / Diagnostic” tools very effectively. In fact, the data
used to gauge “normal” parameters is make / model specific where other equipment
will often use “universal” data, decreasing accuracy in the process.
Printer
The AC690 Pro is sold with an integrated printer. This has been up-graded to allow
you to print your company details (inc. telephone number) along with date, time,
refrigerant recovered, refrigerant charged, oil recovered, oil charged, vacuum time
and vacuum leak test pass / fail and “Next Service” date. Customer and vehicle
details are also on printout when selected from database. The printer can help both
the sales process and record-keeping and print-outs can be generated at any stage
of operation.
Flush-Prepared
The AC690 Pro is sold prepared for liquid refrigerant flushing with integrated software
support. A machine kit and adaptor kit are available as optional extras to up-grade to
full liquid refrigerant flushing capability. Flushing removes contamination and debris
and is essential when components (especially the compressor) have failed. Flushing
is mandatory following compressor failure or system contamination by many vehicle
and compressor manufacturers for warranty purposes.
Features
Product Sheet 1028
Autoclimate Ltd
Unit 37, Atcham Business Park
Atcham, Nr Shrewsbury
Shropshire SY4 4UG
Tel: +44 (0)1743 445566
Fax: +44 (0)1743 464646
Features & Benefits ROBINAIR AC690 Pro
Complete Automation Integrated Printer
Achieved through programmable software Generates data to help the sales process Part No.: 2404-116
and automated oil and dye injection. as well as creating job records for you and Date: 26 March 2008
Reduces “hands-on” time to under 5 your customers. Complete flexibility to print Issue: 0.3
minutes at any stage, includes customer and contact
details SPECIFICATION
Voltage: 220-240v AC 50 Hz
Choice of Operating Modes High Capacity Internal Tank
Refrigerants: R134A
Manual or automatic, beginner or expert for 20.0 kg capacity internal tank Weight: 110kg
maximum flexibility Dimensions: 128cm x 69 cm x 69 cm
Max. Operating
Vehicle Databases Large Gauges Pressure: 16 bar (232 PSI)
Temp. Operating
Integrated OEM vehicle database with Large 80 mm pulse-free Class 1 gauges, Range: 10 - 50ºC
R134A oil data for over 3,900 vehicles mounted near-vertical for easy viewing Warranty: 12 months (optional 3 year extended
with new predic tive selection facility. (displaying Bar, PSI scales) warranty available)
Programmable user database
Diagnostic programme NEW Design
Saves time identifying “vehicle” faults, Durable cabinet with large inflated
suggest out of 36 common faults depending rear wheels and front castors for easy
on test results manoeuvrability in confined spaces
Operator Prompts LCD Display
Visual and audible 80 digit backlit multi-language LCD display
Hoses Condenser
2.5 metre as standard. 5m & 7.5m available Vertically mounted twin-fan super-cooled for
on request high performance in all conditions
Large Memory Facility Tank Gauge
4 MB memory facility to store and edit Shows internal pressure
service data for up to an extra 250 vehicles
Database Up-dates
Smart key up-date facility to keep you up-to-date with new vehicles.
Powerful Heavy Duty Compressor Leak check
Hermetic 1/3 Hp compressor means fast Fully automatic vacuum leak test
and complete refrigerant recovery from the
system at 500 gms pm
Automatic Refrigerant Recycling Automatic UV dye injection
Recycles recovered refrigerant ready for Solenoid controlled
re-use
Auto-restart Air Purge
Recovery / recycling begins again if system Automatic non-condensable gas release
pressure rises valve
Automatic Oil Separation / Injection Electronically Calibrated Scale
Automatic oil separation and automatic Accurate re-charging (resolution to + / - 5
scale-controlled oil injection gms)
Large Vacuum Pump
Powerful two-stage 180 litres per minute vacuum pump to remove air and moisture