TROUBLE SHOOTING (ELECTRICAL)
I.      ENGINE NOT CRANKING:
                                  50                                        71
         +ve              MB1
                                                                                          ESR4
                                                                                    50T
                                MFPB1                   FPC                               ECS’I’
                                                                                   50C
                                                  13C
                                                                                               START
          8 BATTERIES
                                                                                    43
.                               MFPB2                                                     P22
                                                                                    43A
                                                  13                                      S1
                                                                                    43B
                                       FPC COIL
                                                                                                   CK1
                                                              70                                   43C
                                                                                  CK1              CK2
                          MB2
            -ve                  4                             4            4
                                                  A                                                    B
A      FUEL PUMP CONTACTOR MAY BE IN OPEN CONDITION.
     1. Battery knife switch may be in open.
     2. MB1 may be tripped or defective. (49 – 50)
     3. MB2 may be tripped or defective. (44 – 4)
     4. MFPB1 may be tripped or defective (50 – 13C)
     5. MFPB2 may be tripped or defective (13C – 13)
     6. Fuel pump contactor coil may be in open (13,4) or defective contactor (50-70)
B. CK1 AND CK2 CONTACTORS NOT CLOSING
   1. Fuel pump breaker may be tripped or defective. (70 – 71)
   2. MUSD1 may be in stop or defective
   3. MUSD2 may be in stop or defective
   4. ESR4 N/C interlock defective (71 – 50T)
   5. ECS may be in RUN or defective N/C interlock in ECS idle (50T –50C)
   6. Defective start button (50C – 43)
   7. Defective P22 N/C interlock (43 – 43A) or contactor may be welded.
   8. Defective S1 N/C interlock (43A – 43B) or contactor may be welded.
   9. Defective CK1 contactor coil (43B – 4)
   10. Defective CK1 bridge interlock when CK1 is in closed (43B – 43C)
   11. Defective CK2 contactor coil (43C – 4)
   12. Defective traction generator.
                                                                   134
                                                                         Diesel Traction Training Centre/Guntakal
II.ENGINE CRANKING BUT NOT FIRING:
                           71
                                      OPS
                                                          START
                                    50F
                                                        50D
                                     CRT2
                                    50N
                                                         LWS
                                     CK2
                                    50M                 50J
                                     GOV                 GOV
                                     STABILIZING         CLUTCH
                                     COIL                COIL
A:
     1. OPS may be struck up in pick up position (switch in open condition)
        or defective switch (71 – 50F)
     2. CRT2 may be open circuited (50F – 50N)
     3. CK2 N/C bridge inter lock may be defective (50N – 50M) or in open.
     4. Amphinol plug (GE Gov.) may be slack (50M – 4)
B:
     1. Start button may not be closing properly or defective (71 – 50D)
     2. LWS may be defective or low water in expansion tank (50D – 50J)
     3. After energizing CK2 its bridge interlock may not be opened (50N – 50M)
C:
     1.    OST may be in tripped condition
     2.    Fuel oil pressure may be zero
     3.    Fuel pump motor may be failed.
     4.    Fuel booster pump may be defective.
     5.    Fuel booster pump love joy coupling may be failed.
     6.    Fuel oil system may be defective.
     7.    GE Governor Booster pump may be defective.
     8.    GE Governor Booster pump love joy coupling may be defective.
     9.    Governor oil may be less.
     10.   Governor linkage may be disconnected with fuel linkage.
     11.   Fuel oil level may be less.
     12.   W.W. Gov. low lube oil button (LLOB) may be in tripped condition.
                                              135
                                                    Diesel Traction Training Centre/Guntakal
III. ENGINE CRANKING, FIRING BUT NOT HOLDING:
                         71
                                                  OPS
                                            50K
                                             SAR
                                             50D
                                              LWS
                                            50J
                                              GOV
                                              CLUTCH
                                              COIL
 1.   Lube oil pressure may be below 1.6 Kg/cm2
 2.   Lube oil system may be defective
 3.   OPS defective (Switch defective) (71 – 50K)
 4.   SAR closed interlock (N/O) defective (50K – 50D)
                                     136
                                           Diesel Traction Training Centre/Guntakal
IV THROTTLE NOT RESPONDING:
                          16D
              50                    16A
                   MCB1     MCB2         TH‘I’          DMR SELF
                                   30D                  INTERLOCKS
                                         SH 01234
                                   30F            16F
                                         TH ‘I’
                                                        DMR SELF
                                   30B                  INTERLOCKS
                                         SH 01234
                                                        16
                                                         DMR
                                                        30K
                                                         PCS
          1. MCB1 may be defective (50 – 16D) or tripped.
          2. MCB2 may be defective (16D – 16A) or tripped.
          3. TH N/C interlock defective in S.H.C.S. (16A – 30D) or TH may not
              be in Idle.
          4. SH N/C interlocks defective in S.H.C.S (30D – 30F) or SH may not
              be in OFF, 1,2,3,4
          5. TH N/C interlock defective in L.H.C.S. (30F – 30B) or TH may not
              be in Idle
          6. SH N/C interlocks defective in L.H.C.S. (30B – 16) or SH may not
              be in OFF, 1,2,3,4
          7. Defective DMR (16 –30K)
          8. Defective PCS (30K – 4) or PCS may be knocked out
          9. DMR self interlocks defective (16A – 16F – 16)
          10. ESR`s not energizing or defective interlocks.
          11. ECS may be in idle.
          12. GR may be in tripped condition
          13. W.W. Gov. Am phenol plug slack
          14. In AC/DC locos GFOLR may be tripped
                                 137
                                         Diesel Traction Training Centre/Guntakal
V. LOAD METER NOT RESPONDING:
                   13         30E          30C          30CC
                                                                      6
                         TH 1-8   TH 1-8         GFCO-A    GFCO-B
                                                               BKT1
                                                                          6A
                                                               ECS'R'
                                                                          6B
                                                                GR
                                                                          6C
                                                               BKT2
                                                                          6D
                                                                 TR
                                                                          6E
                                                                CK1
                                                                          6F
                                                                CK2
                                                                          6H
                                                          G.F.COIL
With this circuit we can get generator field excitation and main generator induced
EMF connected to traction motors through BKT, REV and Power contactors.
1. LOAD METER NOT RESPONDING.
  This may be due to following reasons.
  a. Generator field contactor not closing (GFC)
  b. S1, S21, S31 power contactors not closing
  c. Excitation cards slack or defective
GENERATOR FIELD CONTACTOR NOT CLOSING
Control air pressure may be less than 5 Kg/CM2
   a. Throttle handle interlocks in working control stand may be defective or open
   b. GF switch No. 1 or No. 2 may be defective or wire cut
   c. BKT 1 or BKT 2 May not be thrown properly or its inter lock may be defective
   d. ECS may be in idle or defective switch
   e. GR may be tripped or defective
   f. Transition relay inter lock may be defective
   g. CK 1 welded or bridge inter lock may be defective
   h. CK 2 welded or bridge inter lock may be defective
   i. GF contactor may be defective
                                                  138
                                                        Diesel Traction Training Centre/Guntakal
Note : If BKT 1 or 2 operating towards motoring properly, even then GFC not closing
Pack GFC and work on wards. Before packing GFC ensure that CK 1 & CK 2 must be in
deenergized condition (open).
S1, S21, S31 Power contactors not closing
   a. Reversed handle not thrown properly or its interlocks may be defective
   b. Reverser 1 & 2 May not be thrown properly or its interlocks may be defective.
   c. BKT 1 or BKT 2 interlocks may be defective
   d. ECS inter lock may be defective
   e. BKR inter lock may be defective
   f. TR & GFC inter lock may be defective
   g. P1 power contactor may be welded or its inter lock may be defective
      S21 Alone not picking up
      P21 Power contactor may be welded or inter lock may be defective
      S31 Alone not picking up
      P31 Power contactor may be welded or inter lock may be defective
EXCITATION CARDS SLACK
  a. Remove safety bar from the excitation panel.
  b. Slack all the 7 Excitation cards and press for proper fitment
LOAD METER NOT RESPONDING AFTERPICKING UP 2nd TRANSITION
  a. P32 power contactor may not be closed (not energized)
  b. P32 power contactor interlock may be defective
LOAD METER NOT RESPONDING DURING MOTORING AFTER WORKING
DYNAMIC BRAKE
       1. BKT 1 or BKT 2 may not thrown properly towards motoring
       2. BKT 1 or BKT 2 interlocks may be defective
LOAD METER NOT RESPONDING IN ONE DIRECTION
  a. Working control stand reverser handle defective
  b. Non working control stand with or with out reverser handle kept in one direction
  c. REV 1 & 2 may not thrown properly on one direction
  d. REV 1 & 2 interlock may be defective.
   LOAD METER NOT INDICATING: (But power available)
        1 During Loco starting (Moving) S1 power contactor is not picking up.
        2 TM1 or TM4 may be defective
        3 LAS may be defective
        5. Load ammeters and its circuit may be defective.
        6. After picking up IInd transition P2 Power contactor is not picking up.
                                         139
                                               Diesel Traction Training Centre/Guntakal
SAFETY DEVICES FITTED IN DIESEL ELECTRIC LOCOMOTIVE
                                  (Electrical)
                               DEAD MAN’s RELAY
                       16D
        50                         16A
              MCB1        MCB2         TH‘I’           DMR SELF
                                 30D                   INTERLOCKS
                                       SH 01234
                                 30F             16F
                                       TH ‘I’
                                                       DMR SELF
                                 30B                   INTERLOCKS
                                       SH 01234
                                                       16
                                                        DMR
                                                       30K
                                                        PCS
1.DEADMAN`S RELAY: This is fitted in front panel of control compartment. When
   MCB1 and MCB2 switched ON, this relay will energize, through PCS. Whenever PCS
   is knocked out DMR will de-energize and engine will come to idle. The PCS will be
   operated during emergency brake application, train parting and in accidents.
                                         140
                                               Diesel Traction Training Centre/Guntakal
                                 GROUND RELAY
                                                  CK1
     GA 11
                                  A
                                  C                                 BS
                                  C
                                  R
                                 TG
                                                                  BATTERY
                                   36
             GRCO                     CP
                                      FIELD
                       36B
                 GR
                                      STARTING                     BS
                                      FIELD
                                             CK2
                  EARTH
                                  GK 2
          GA 2
2.GROUND RELAY: GR is fitted in front panel right side of the control compartment.
When ever power circuit gets earth fault during running or whenever control circuit
gets earth fault during engine starting this relay will energize.
GR is connected in between –VE of main generator and locomotive body through GRCO.
If any insulation punctures, leakage takes place or any bus bar or cable touches the
body (ground), the leakage current flows through the GR coil and energize. With this
load meter will drop to zero, engine comes to idle with GR indication and alarm.
                                         141
                                               Diesel Traction Training Centre/Guntakal
                            SAFETY AUXILLIARY RELAY
                           4                                 71
                                 TACHO                                       OPS
                  ECP            GEN
                                                                   50 K
                                 SUPLY
                               31
                                                                            SAR
                    SAR                                            50 D
                               31Z
                                                                           LWS
              SPEED                                                 50 J
              PILOT
              VALVE
                                                         GOVERNOR
                                                         CLUTCH
                                                         COIL
3.SAFETY AUXILIARY RELAY: This relay is provided in GE governor locomotives to
protect the engine (During engine running) from over speeding in case of any open
circuit takes place in Governor speed coil circuit. This SAR is connected in series with
speed coil (Pilot Valve). When engine is in running if speed coil current reduces below
220 Milli Amps. (from 475 Milli Amps) SAR will be de-energized. The closed interlock
connected in clutch coil will open and supply will cut off to clutch coil, there by `A`
Arm and `B` Arm will be separated, `B` Arm comes to no fuel position and engine will
come to shut down without any indication.
                                          142
                                                Diesel Traction Training Centre/Guntakal
                              OIL PRESSURE SWITCHES
                                                             71 (+VE) WIRE
                                                                   OPS1
                                  (ENGINE
                                  START)                                  50F
                                                       50K
                                                             SAR
                                              50D
                                                ESR1
                                ESR4                         OPS2
                                       ESR2    50D1
                                                 ESR2
                                               50D2
                                               LWS
                                               50J
                        GOV. CLUTCH COIL
                                                             4 (-VE) WIRE
4. a.) OIL PRESSURE SWITCH 1: These are fitted in GE governor locomotives only.
It is located in drivers cab. On run if TH handle is below 6th notch if lube oil pressure
drops below 1.3 kg/cm2 this switch will drop. Its closed interlock will open, and clutch
coil will be de-energized. There by `A` and `B` arms will separate and `B` arm will
come to no fuel position. Engine will come to shut down. OPS open interlock will close
and low lube oil indication with bell will come. (Audio and visual indication) .OPS picks up
at 1.6 kg/cm2.
     b.) OIL PRESSURE SWITCH 2: On run if TH handle is above 7th notch if lube oil
pressure drops below 3.5 kg/cm2 this switch will drop. Its closed interlock will open,
and clutch coil will be de-energized. There by `A` and `B` arms will separate and `B`
arm will come to no fuel position. Engine will come to shut down. OPS open interlock will
close and low lube oil indication with bell will come. (Audio and visual indication) .
OPS picks up at 3.7 kg/cm2.
                                              143
                                                     Diesel Traction Training Centre/Guntakal
                               LOW WATER SWITCH
                       71
                                      OPS
                                     50K
                                     SAR
                                      50D
                                   LWS
                                                     5B
                                      50J            (For Hot Engine
                                                     Indication and
                               GOV                   alarm)
                               CLUTCH
                               COIL
5.LOW WATER SWITCH: LWS is fitted in cooling water system and located in
compressor/expressor room. It is connected in series with Governor clutch coil by its
closed switch. (If cooling water level is above 1” from the bottom of expansion tank)
Whenever water level is reduced below 1” from the bottom in expansion tank, LWS will
operate and its closed interlock will open and cut off supply to Governor clutch coil.
`A` arm `B` arm will be separated `B` arm will come to no fuel position and engine
comes to shutdown. LWS open interlock will close and hot engine indication with alarm
will come. (Audio and visual indication)
                                         144
                                               Diesel Traction Training Centre/Guntakal
                        ENGINE TEMPERATURE SWITHCHES
                   71
                           TS1          R1
                                 72B
                                                           ECC
                                 R1    72
                           TS2         R2
                                 72C
                                 R2      72
                           ETS    5B
                                         HEA
                                                72
                                       ERF
6. ENGINE TEMPERATURE SWITHCHES: The heat generated in the engine
cylinders has to be dissipated efficiently; pressurized water-cooling system is
employed in the diesel engine. The cooled water is collected from the radiators and
pumped through various channels in the engine block by the water pump, which is gear
driven by the engine crank shaft. After exchanging the heat, the water is cooled in the
radiators by forced air. Atmospheric air is drawn through the radiator FINS by the
radiator fan coupled to the engine by eddy current clutch.
    At 68°c TS1 switch will close R1 operating coil will energize. R1 contactor will
     close and ECC will get supply. Now radiator fan will work in full speed.
    At 74°c TS2 will close R2 operating coil will energize. R2 contactor will close and
     ECC will get supply. Now also radiator fan will work in full speed only.
    At 90°c ETS will close and hot engine indication with alarm will come.
    If radiator fan is not working switch ON ERF. Now ECC will get direct supply
     bye passing entire electrical control system.
                                              145
                                                     Diesel Traction Training Centre/Guntakal
                                                   WHEEL SLIP RELAY
          GA 11                                                                                             GA 11
          1              2              3                   1          5           2          3       4          6
                                                    WSRR1
      F              F          F           WSR3
                                                                WSR1                   WSR2               WSR3
              WSR1
                                                        F         F            F         F        F         F
          4              5   WSR2       6
                                                                                                             GA 2
                                                    WSRR2                  PARALLEL COMBINATION
      F              F              F
       GA 2 SERIES PARALLEL COMBINATION
7. WHEEL SLIP RELAY: In the locomotive all the six wheels are powered by six
individual traction motors coupled through a gear, if any one of the wheel is slipped due
to loss of adhesive or not rotating due to locked axle, the wheel will skid and has to be
machined. To detect the locked axle or pinion slip or wheel slipping on the track, a
safety device is called WSR is provided to operate. If any potential difference takes
place between any two Traction motors this relay will operate and T.G. Field excitation
will be reduced (nullified) and load meter drops to zero, wheel slip indication with
buzzer and auto sand application will takes place.
To identify the particular motor there are two WSR coils in each relay. One is in series
parallel combination another is in parallel combination.
8.OVERSPEED TRIPPING ASSEMBLY: In case of any electric speed signals (Circuit)
problem there is every chance of engine RPM shooting and damage to the engine and
crankshaft. A mechanical tripping device is connected to the fuel rack when the engine
RPM is increased beyond 1140 RPM the fuel racks are forcibly brought to no fuel
position by tripping OSTA and engine will come to shut down without indication.
 If engine is re-cranked with OSTA tripping position, engine will crank firing will not
takes place resulting batteries discharging.
                                                            146
                                                                  Diesel Traction Training Centre/Guntakal
            REASONS FOR ENGINE AUTOMATIC SHUT DOWN
                       (WITH INDICATION)
1. Water level in Expansion Tank is reduced from the bottom below 1” and causing
   LWS operation. (Hot Engine indication with Alarm)
2. Lube oil pressure dropping below 1.3 kg/cm2, up to 6th notch causing
   OPS-1 dropping. (Low Lube oil indication with alarm)
3. Lube oil pressure dropping below 3.5 kg/cm2 in 7th & 8th notches causing
   OPS 2 dropping. (Low Lube oil indication with alarm)
                           (WITHOUT INDICATION)
4. In G.E. Governor Locos Governor Amphinol Plug slack
5. In G.E. Governor Locos Tacho Generator signal failed to Governor and causing
    SAR Relay dropping
6. Fuel Pump Breaker tripping.
7. Fuel Pump contactor opening.
8. MFPB-1 or MFPB-2 tripping.
9. MB-2 Breaker tripping.
10. MB-1 & AGFB together tripping.
11. Battery Knife switch open and AGFB tripping at a time.
12. Fuel Pump Motor fail.
13. Fuel Booster Pump or Governor Booster Pump failed.
14. Fuel Booster Pump Lovejoy coupling or Governor Booster Pump Love joy coupling
    failed.
15. Fuel Oil system defective.
16. Fuel oil very less in tank.
17. Governor Oil less in tank.
18. Governor oil pressure may be less.
19. Governor linkage may be disconnected.
20. OSTA may be tripped.
                                     147
                                           Diesel Traction Training Centre/Guntakal
               REASONS FOR AUTOMATIC ENGINE COMING TO IDLE
                            (WITH INDICATION)
   1. G.R. may be operated (explosive or non-explosive P.G.)
   2. GFOLR may be operated (AC/DC Locos).
                                (WITHOUT INDICATION)
   3. DMR may be de-energized:
         a) PCS-2 knocked out due to A-9 emergency.
         b) P2 may be closed due to BP dropping below 4.4 kg/cm2 in Brake pipe.
         c) PCS-1 knocked out due to vacuum train pipe vacuum dropped.
         d) Fire man emergency may be operated.
         e) MCB-1 or MCB-2 may be tripped.
         f) DMR self interlocks may not be having proper contact(Defective)
   4. ERR Relay may be de-energized ( in W.W. Gov. Loco)
   5. Governor Amphenal plug slack. ( in W.W. Gov. Loco).
   REASONS FOR CONTINUOUS WHEEL SLIP
   1. Locked axle.
   2. Traction motor defective.
         a) Pinion slipped
         b) Loose connections any where in power circuit(T.M).
         c) Open Circuit in TM internal connections
         d) TM Bearing seized.
   3. Any FS contactor may be welded.
   4. During 1st and 3rd any one FS contractor not pick up.
   5. Paper or tape between any contactors (PC, BKT, REV, FS contractor).
   6. WSR resistance 1 or WSR resistance 2 may be open circuited                 causing
      continuous wheel slip below II nd transition (From starting of Loco)
Identification of defective traction motor
In series parallel picking up    In parallel picking up of     Defective Traction motor
       of WSR relay                    WSR relay
           WSR 1                          WSR 1                         No. 1
          WSR 2                           WSR 2                         No. 2
          WSR 3                           WSR 2                         No. 3
           WSR 1                          WSR 3                         No. 4
          WSR 2                           WSR 1                         No. 5
          WSR 3                           WSR 3                         No. 6
                                           148
                                                 Diesel Traction Training Centre/Guntakal
REASONS FOR POWER GROUND.
  1. In power system some where earthed.
  2. Power contactors fluttering
  3. Transition pickup & dropout at the same time.
  4. Control Air pressure may be improper.
  5. Water or oil entered in electrical machinery.
  6. Cables or bus bars rubbing any where to loco body.
  I PACKING OF FPC CONTACTOR IN NORMAL.
  1. Open battery knife switch and switch OFF all the breakers.
  2. Pack the contactor with wooden wedge.
  3. Switch on BS and all the breakers.
  II PACKING OF FPC CONACTOR IF COIL IS IN BURNT CONDITION.
  1. Remove 13 +ve wires in FPC contactor coil terminal and join all the 13 wires with
     conducting wire outside the terminal.
  2. Remove 4 –ve wires in FPC Contactor Coil terminal and join all the 4 wires with
     conducting wire outside the terminal
  III. PACKING OF GF CONTACTOR IN NORMAL.
  Note:- Before packing ensure CK1 & CK2 must be in open condition (De-
            Energized)
  1. Keep TH-I, REV Neutral, both GFC-OFF and ECS – idle.
  2. Pack the GF contactor with wooden wedge.
  3. ECS - run both GFCO-ON, REV- Required direction SA9 – full application, A9-
     minimum and open TH-1 notch.
  Load meter will shoot to abnormal and jerk will be experienced, after few
     seconds LM will come to normal.
  IV. Packing of GF contactor If coil is in burnt condition.
       After doing item (1) in above, GF coil 6H terminal wires to be removed and join
  all the wires with conducting wire outside the terminal.
  GF coil 4 terminal wires to be removed and join all the wires with conducting wire
  outside the terminal.
  Continue above procedure item 2&3 in “III” for GF packing.
  Note :-II nd transition will not pickup with GF contactor packing
           (a.). After getting more than 48 Km speed close the TH to idle and
           open, now IInd transition will pickup.
           (b.). Close the TH to idle and apply manual transition (irrespective of
             Loco speed) open TH IInd transition will pick up.
           (c). DB should not be used.
                                        149
                                              Diesel Traction Training Centre/Guntakal