ZEFTRONICS: SOLUTIONS
R15V0L
                                      14V ELECTRONIC ALTERNATOR CONTROLLER
                            Features:                                                                         Benefits:
•     Voltage Regulation, Pulse Width Modulated ∗                       Increased Regulator life. Reduced panel lights flicker
•     Field-to-Ground Fault Protection (GFP)                      ∗     Protects against grounded alternator field
•     Trouble-Shooting Light (TSL)                                ∗     Identifies grounded field. Reduce trouble-shooting time.
•     Over-Voltage Protection                                     ∗     Protects system loads against overexcited alternator
Voltage Regulation: 14.2V + 0.2V. Max Field Current: 5A. Field-to-Ground Protection @ Field current > 6A
VOLTAGE REGULATION.                                                                 Wiring Diagram                      Alt Field     BUS                 Alt Out
The Voltage Regulator with Pulse Width Modulated                                                                        5A
                                                                                                                                                    40A-
                                                                                                                                                    100A
(PWM) field control keeps the bus voltage constant                                                                                   Bat
                                                                                                                                     Relay
by controlling the alternator’s field current:
increasing it when the system load increases and                                                                                               Diode is
decreasing it when the load drops.                                                                       ACU       Red                         used on
                                                                                                                                               Pipers
                                                                                                                                                              Bat
                                                                                                                   White            OV /GFP
OVER VOLTAGE (OV) PROTECTION.                                                                                                                          F1
The OV Protector (OVP) deactivates (turns off) the                                                                 Blue
                                                                                                                                                            ALT
Voltage Regulator and the alternator if the bus                                                                    Black                              F2
voltage exceeds 16V to protect sensitive avionics
equipment and the battery.
OV & FIELD-GROUND SHORT WARNING.                                                                                                          3.63”
                                                                                  Mounting Diagram
A warning light connected between the white wire                                         Height: 1.10”
and ground comes on to warn the pilot of the bus
                                                                                                                   0.22”,
voltage exceeding the OV level or alternator Field-                                                                 2 pl.              TSL
to-Ground Fault Protection (GFP).
                                                                                                                3.31”
FIELD TO GROUND SHORT PROTECTION.                                                                                  1.50”
If the alternator's field shorts to ground, the field-to-
ground short protector will deactivate the Voltage
Regulator, and switch on the unit's RED field-to-
                                                                                                                   1.20”
ground short indicator, and the GFP/ OV indicator
on the instrument panel.
                                                                                                                   0.28”, 6 pl
TROUBLE-SHOOTING LIGHT (TSL)
The TSL (on the unit) is designed to alert the user
to the condition of the Alternator / ACU system.
                                                                               Trouble-Shooting Light Continued ….
RED TSL indicates: An internal or external ground
                                                                               With the engine running, master switch on, and bus
short in the alternator field circuit
                                                                               voltage @ about 12V, GREEN TSL indicates that cur-
Without the engine running but master switch on,
                                                                               rent is flowing from the ACU but the
GREEN TSL indicates that the ACU is supplying
                                                                               alternator field or field wire to it is open.
current to the alternator’s field.
With the engine running, master switch on, and bus                             With the master switch on, if the TSL is off , that indi-
voltage @ about 14V, GREEN TSL indicates cor-                                  cates that one power input device (e.g. switch, circuit
rect alternator output voltage.                                                breaker, or wiring) is open or the ACU is defective.
By Femi G. Ibitayo                         1622 E. Whaley St., Longview, TX 75601. USA
©2003, ZEFTRONICS, Tovya Group Inc         Ph: 903-758-6661; Fax: 903-236-9766. E-mail: Tech@zeftronics.com                             ZEFTRONICS
R15V0L-PIT.pub.              Pg 1/4                Ph: 1-800-362-8985. Web Site: www.zeftronics.com                                     Electrical Charging Systems Solutions
                                                                                                                                                     ZEFTRONICS: SOLUTIONS
                                                                      R15V0L
                                          14V ELECTRONIC ALTERNATOR CONTROLLER
                     HOW THE SYSTEM WORKS
                                                                                                           INSTALLATION INSTRUCTION
When the master switch is turned on, battery voltage is
applied to the input of the R15V0L or similar alternator                             1. Disconnect and remove the present ACU.
controller/voltage regulator through the input devices                               2. At the ACU, measure the alternator’s field resistance:
and wires from the bus. The current passing through the                                 i.e. resistance between the field and the ground wire. A
voltage regulator is applied to the field of the alternator.                            resistance of 3.5 to 6Ω is normal. If the measured
Without the engine running, the field voltage is typically                              resistance is outside the specified range, check the
0.5-2V less than the bus or battery voltage.                                            alternator field and the connections/wire from the
                                                                                        ACU’s field wire to ground. 0Ω indicates a field to
Voltage Regulation
When the engine is running, the voltage regulator keeps                                 ground short. Correct the fault.
the bus voltage constant by controlling the alternator’s                             3. Mount and connect the new ACU to the system.
field current: increasing it when the system load                                    4. Perform the Post Installation Test Procedure.
increases and decreasing it when the load drops.The
regulated bus voltage is normally about 14V unless the                                            POST INSTALLATION TEST PROCEDURE
alternator is self-current limiting1 or if there is a voltage                        1. Turn on the Master switch and observe:
drop in the input devices preceding ACU.                                                On the ACU the TSL light is on. A Red TSL indicates
                                                                                        that the Field or field wire is shorted to ground.
OVER VOLTAGE PROTECTION.
To protect sensitive avionics equipment and other sys-                               2. Measure the voltage on Red and Blue wires. The Red
tem loads, if the bus voltage exceeds 16V the OV                                        should read Battery voltage, while the Blue reads 1-2
Protector (OVP) deactivates (turns off) the Voltage                                     volts less than the Red wire.
Regulator to remove the alternator’s field current. The                              3. If the steps 1 and 2 are successful, perform step 4.
ACU stays latched off until the alternator switch is reset.                          4. Turn off all the avionics and voltage sensitive loads.
                                                                                        Start the engine. At 1500-1600 RPM measure bus
Field-to-Ground Short Protection                                                        voltage: It should read 13.8V - 14.4V. If the bus
Should the alternator's field become shorted to ground                                  voltage exceed these limits, check for voltage drop in
the field-to-ground short protector turns off the Voltage                               the 5A breaker, the Alt switch, and pre-ACU wires.
Regulator, and switches on the ACU's Red field-to-
ground short TSL and the instrument panel’s OV light .                                          TROUBLE-SHOOTING THE SYSTEM
TROUBLE-SHOOTING LIGHT (TSL)                                                         For help on how to solve problems in the system, see the
The TSL on the unit alerts the user to the condition of                              Trouble-Shooting Notes (TSN) page and or TechCards.
the Alternator / ACU system. The TSL has three color/
states: Red, Green, and Off.
Red TSL indicates: An internal or external ground short                                      Wiring Diagram
in the alternator field circuit                                                                                           Alt Field     BUS                    Alt Out
                                                                                                                                                         40A-
Without the engine running but master switch on, Green                                                                   5A
                                                                                                                                                         100A
TSL indicates that the ACU is supplying current to the                                                                                 Bat
                                                                                                                                       Relay
alternator’s field. An off TSL indicates that one of the
power input devices is open or the ACU is defective.                                                                                                Diode is
With the engine running, master switch on:                                                                    ACU Red                               used on
                                                                                                                                                    Pipers
                                                                                                                                                                   Bat
A bus voltage @ about 14V, Green TSL indicates cor-                                                                    White          OV /GFP
rect alternator output voltage.                                                                            R15V0L Blue
                                                                                                                                                           F1
A bus voltage @ about 12V, Green TSL indicates that                                                                                                              ALT
                                                                                                                       Black                               F2
current is flowing from the ACU but the alternator field
or field wire to it is open.
1
  self-current limiting—Internal characteristics of the alternator that
causes it to limit its current and voltage output at a given speed.
 By Femi G. Ibitayo                                  1622 E. Whaley St., Longview, TX 75601. USA
 ©2003, ZEFTRONICS, Tovya Group Inc
 R15V0L-PIT.pub.              Pg 2/4
                                                    Ph: 903-758-6661; Fax: 903-236-9766. E-mail: Tech@zeftronics.com
                                                            Ph: 1-800-362-8985. Web Site: www.zeftronics.com
                                                                                                                                               ZEFTRONICS
                                                                                                                                               Electrical Charging Systems Solutions
                                                                                                                                         ZEFTRONICS: SOLUTIONS
                                        TROUBLE-SHOOTING THE SYSTEM
                                     14V Type B alternator system on Beech, Piper, etc
                                      R15V0L or similar Controller/ACU
When the master switch (ALT & BAT) is turned on, bat-                          With the engine off, when the master switch (Alt & Bat)
tery voltage is applied to the Bus & OV Relay input.                           is turned on, battery voltage (12V) is applied to the input
                                                                               of the ACU through the 5 Amp FLD circuit breaker, ALT
Take all voltage measurements at test points A, B, D, E                        switch and the OV Relay. The applied voltage causes
and F referenced to ground.                                                    current to flow to the alternator’s field through the ACU
   A. __________ Volts.                B. _________ Volts                      to excite the alternator’s field.
   D __________ Volts.                 E. _________ Volts                      With the engine on and the master switch on, the ACU
   F __________ Volts.                 Fl. _________ Volts                     controls the excitation of the alternator to produce a Bus
                                                                               voltage of 13.8 –14.3V. This regulated voltage charges
The voltages measured at A, B, D, and E should be the
                                                                               the battery and allows the alternator to power all the elec-
same, Bus voltage (around 12V). The voltage on F (field
                                                                               trical system loads in the aircraft.
or alternator controller/voltage regulator output) will be
0.5 to 2V less than the voltage at A, B, D, or E. The volt-                    The 5 Amp circuit breaker opens if the current going to
age at F1 will be the same as F.                                               the ALT field exceeds 5 Amps, after a preset time lag, to
                                                                               protect the wire from the Bus to the field. Some wrongly
If the voltage at A is 0.2V more than that on D, check the
                                                                               expect this breaker to protect their non-Zeftronics ACU.
5 Amp breaker, ALT switch, and connections between
the bus and D for high resistance or open circuit. A high                      If the Bus voltage exceeds the preset over-voltage (OV)
resistance between A & D may lead to flickering / oscil-                       limit, the OV Relay, which is normally closed, will open
lating ammeter and panel lights. An open circuit be-                           up and disconnect the Bus from the ACU to remove exci-
tween A & D will not allow current to get to the control-                      tation from the alternator’s field.
ler/regulator and subsequently no current to the alterna-
                                                                               When power is applied to a static (non-rotating) alterna-
tor’s field and no voltage regulation. When there is no
                                                                               tor through the ACU/regulator, the F1 voltage is 0.5-2V
voltage regulation, the Bus voltage remains at battery
                                                                               less than Bus voltage. When the alternator is rotating, F1
voltage (about 12V).
                                                                               voltage will start low and increase with each load in-
If the voltage on F1 is 0.2V or more less than the voltage                     crease until the alternator current limits.
F, check for poor connection or open circuit between the
controller/regulator output and F1 on the alternator. If                       See TechCard for resistance and voltage measurements.
the resistance between the F and F1 is higher than 0.5Ω,
the alternator may not carry its rated load, showing a
symptom similar one where there is an open stator wire
or open diode in the alternator.                                                            Wiring Diagram         Alt Field     BUS                Alt Out
                                                                                           Type B Alternator             A                      40A-
                                                                                                                  5A
If the voltage on F1 is 0V or close , check for a ground                                    Control System               B       Bat
                                                                                                                                                100A
                                                                                                                                                         J
short on F1 on the alternator or wire from F on the con-                                                                         Relay
                                                                                                                         C
troller/regulator.
                                                                                                                                         Diode is
If there is a field-to-ground short, the R15V0L will turn                                  ACU        OVP       Red      D               used on
                                                                                                                                         Pipers
                                                                                                                         E                               H Bat
itself off and turn its built-in Trouble-Shooting Light                                                          White         OV /GFP
(TSL) Red.                                                                                             VR
                                                                                                                Blue     cF                         F1
                                                                                                                                                         ALT
An open stator wire or open diode in the alternator will                                   R15V0L               Black                             F2
make the alternator only able to carry about half its
rated output. For example, a 70A 12V alternator has a
14V output with about 30A load on it. When the load is                             In this Type B system: the ACU is between the BUS and the Alt field.
                                                                                   To control the bus voltage, the unit switches power to one side of the
increased to 40A, the bus voltage drops to 12 to 13V,
                                                                                   field several times a second. The OVP opens when OV occurs.
indicating an alternator that is current limiting.
See TechCard for resistance and voltage measurements.
By Femi G. Ibitayo                          1622 E. Whaley St., Longview, TX 75601. USA
©2003, ZEFTRONICS, Tovya Group Inc          Ph: 903-758-6661; Fax: 903-236-9766. E-mail: Tech@zeftronics.com                       ZEFTRONICS
R15V0L-PIT.pub.             Pg 3/4                  Ph: 1-800-362-8985. Web Site: www.zeftronics.com                               Electrical Charging Systems Solutions
                                                                                                                                            ZEFTRONICS: SOLUTIONS
                                      Frequently Asked Questions & TECHCARD Notes
                                         14V Type B alternator system on Piper, Beech, etc
                                            TROUBLE-SHOOTING THE SYSTEM
                                                                                     OUR GOAL IS TO HELP YOUR SYSTEM OPERATE BETTER                  ZEFTRONICS
 Flickering / oscillating ammeter and panel lights.                                       AND HELP YOU UNDERSTAND ITS OPERATION.
                                                                                                                                                    TECHCARDS
Check the 5 Amp breaker, ALT switch, and connections                          INSTALLATION TESTS. BEFORE INSTALLING THIS UNIT, PERFORM TESTS:
                                                                                  1. Read pages 1 to 3 and this page.
between the bus and the input to the ACU for high resis-                          2. Check for and replace open, frayed, or broken wires. Clean thor-
tance or intermittent connection..                                                   oughly or replace corroded, dirty, or oxidized connections, terminals,
                                                                                     contact, or poorly soldered wire junction.
                     No voltage regulation                                        3. Check for Open or Ground-shorted alternator field. Most 12V alter-
With the master switch on and Battery voltage measured                               nators have 3-6Ω field resistance. Ground shorted alternator field
on the ACU input, the ACU output voltage should be 0.5                               will damage most Voltage Regulators/ACU. Repair or replace an
to 2V less the bus voltage.                                                          alternator has a field to ground short, do not connect the ACU to it.
                                                                                  4. With the engine off: Check voltage drops across the Field, Alt
  • If there is no Bus voltage on the ACU input, look                                switch, Alt field circuit breaker and ACU. High voltage-drop means
     for a broken wire, bad connection or input device                               excessive junction resistance and will lead to many problems like:
     (5A circuit breaker or Alt switch) between the ACU                              fluctuation ammeters, charge-meters and panel lights.
     and the bus.                                                                 6. Perform and record the following tests with the Master Switch Off:
  • If the input voltage is more than 0.2V lower than                                                                      12V Values        Typical Values
                                                                                     A. Field resistance at ALT            __________Ω           3 – 6Ω
     the bus voltage, look for and correct or replace the
                                                                                     B. Field resistance at ACU            __________Ω           3 – 6Ω
     input device that is causing the problem.                                       C. Field SW resistance                __________Ω           0 – 0.1Ω
  • If the output voltage is 0V and the input has battery                            D. Field C/BKR resistance             __________Ω           0 – 0.05Ω
     voltage, look for a grounded alternator field or field                          E. ALT Out C/BKR resistance           __________Ω           0 – 0.05Ω
     wire (as indicated by a Red ACU TSL). If the field                           6. Perform and record the following tests with the Master Switch On:
                                                                                                                           12V Values        Typical Values
     resistance is correct as shown in step 5 of the instal-
                                                                                     A. BUS Volt Engine Off                __________V           12 – 13V
     lation tests and the ACU’s Trouble-Shooting Light                               D. ACU/Reg input Volt                 __________V           12 – 13V
     (TSL) is off, send the ACU in for test/repair.                                  F. Field Voltage                      __________V         0.5-2V <VBus
  • If the TSL is Red, repair the field ground fault or                           7. Post Installation. If all tests are correct to or per steps 5 & 6, run
     replace the alternator.                                                         the engine and record:                12V System         Typical value
                                                                                     A. Bus voltage                        __________V          13.8 – 14.3V
  • If the output voltage is the same as the input volt-                             H Bus voltage                         __________V          13.8 – 14.3V
     age, look for an open alternator field or field wire.                           J Bus voltage                         __________V         13.8 – 14.3V
     If the field resistance is higher than what is shown
     in step 5 of the installation tests, send the alternator
                                                                              For tech help & other TechCards, call: 903-758-6661
     in for test/repair. If the field resistance is correct,
     send the ACU in for test/repair.                                          © ZEFTRONICS, 2002                               ZEFTRONICS
                                                                                                                                Electrical Charging System Solutions
Bus voltage remains at battery voltage (about 12V)
To solve this problem, see No voltage regulation.                                            Wiring Diagram         Alt Field       BUS                 Alt Out
                                                                                            Type B Alternator             A                         40A-
                                                                                                                     5A
 Alternator carries only about half its rated output.                                        Control System               B         Bat
                                                                                                                                                    100A
Look for an open stator wire or open diode in the                                                                                   Relay                    J
                                                                                                                          C
alternator. In Piper PA 28 & 32 series, check the
                                                                                                                                             Diode is
condition of the diode between the bus (J) and alternator                                  ACU         OVP       Red      D                  used on
output (H). Check the shunts and alternator output wires                                                                  E
                                                                                                                                             Pipers
                                                                                                                                                             H Bat
                                                                                                                  White
indicating an alternator that is current limiting.                                                     VR
                                                                                                                                OV /GFP
                                                                                                                 Blue     F                             F1
Bus voltage drops with load increase                                                                                                                         ALT
                                                                                           R15V0L                Black                                  F2
To solve this problem, see Alternator carries only
about half its rated output.
                                                                                    In this Type B system: the ACU is between the BUS and the Alt field.
                                                                                    To control the bus voltage, the unit switches power to one side of the
                                                                                    field several times a second. The OVP opens when OV occurs.