0% found this document useful (0 votes)
166 views6 pages

SM4000 00 - en Us

The document provides product specifications for the SM4000 Magnetic-inductive flow meter, including its measuring range of 5-3000 ml/min, inputs/outputs of 2 digital outputs and 1 analog output, operating voltage of 18-30V DC, accuracy of ±(2% MW + 0.5% MEW), and communication interface of IO-Link. It describes the meter's functions, media compatibility, electrical and mechanical specifications, and parameter setting options.

Uploaded by

Angga Suryadarma
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
166 views6 pages

SM4000 00 - en Us

The document provides product specifications for the SM4000 Magnetic-inductive flow meter, including its measuring range of 5-3000 ml/min, inputs/outputs of 2 digital outputs and 1 analog output, operating voltage of 18-30V DC, accuracy of ±(2% MW + 0.5% MEW), and communication interface of IO-Link. It describes the meter's functions, media compatibility, electrical and mechanical specifications, and parameter setting options.

Uploaded by

Angga Suryadarma
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

SM4000

Magnetic-inductive flow meter


SMR14DXXFRKG/US-100

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range 5...3000 ml/min 0.005...3 l/min
Process connection threaded connection G 1/4 DN6 flat seal
Application
System gold-plated contacts
Application Totalizer function; for industrial applications
Installation connection to pipe by means of an adapter
Media Conductive liquids; water; water-based media
conductivity: ≥ 20 µS/cm
Note on media
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C] 0...60
Pressure rating [bar] 10
Pressure rating [Mpa] 1.2
MAWP (for applications
[bar] 7.3
according to CRN)
Electrical data
Operating voltage [V] 18...30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA] < 80
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 5
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Inputs
Inputs counter reset

ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SM4000-00 — 03.08.2021 —
SM4000
Magnetic-inductive flow meter
SMR14DXXFRKG/US-100

Outputs
Total number of outputs 2
Output signal switching signal; analog signal; pulse signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching
[V] 2
output DC
Permanent current rating of
[mA] 200
switching output DC
Number of analog outputs 1
Analog current output [mA] 4...20; (scalable)
Max. load [Ω] 500
Analog voltage output [V] 0...10; (scalable)
Min. load resistance [Ω] 2000
Pulse output flow rate meter
Short-circuit protection yes
Type of short-circuit
yes (non-latching)
protection
Overload protection yes
Measuring/setting range
Measuring range 5...3000 ml/min 0.005...3 l/min
Display range [ml/min] -1999...3600
Resolution [ml/min] 1
Set point SP [ml/min] 20...3000
Reset point rP [ml/min] 5...2984
Analog start point ASP [ml/min] 0...2400
Analog end point AEP [ml/min] 600...3000
Low flow cut-off LFC [ml/min] < 60
Volumetric flow quantity monitoring
Pulse value 1...3000 ml
Pulse length [s] 0,008...2
Temperature monitoring
Measuring range [°C] -20...80
Resolution [°C] 0.2
Set point SP [°C] -19.2...80
Reset point rP [°C] -19.6...79.6
Analog start point [°C] -20...60
Analog end point [°C] 0...80
In steps of [°C] 0.2
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring
± (2 % MW + 0,5 % MEW)
range)
Repeatability ± 0,2% MEW

ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SM4000-00 — 03.08.2021 —
SM4000
Magnetic-inductive flow meter
SMR14DXXFRKG/US-100

Temperature monitoring
Accuracy [K] ± 2,5 (Q > 0,5 l/min)
Reaction times
Flow monitoring
Response time [s] 0.15; (dAP = 0, T19)
Delay time programmable dS,
[s] 0...50
dr
Damping for the switching
[s] 0...5
output dAP
Temperature monitoring
Dynamic response T05 / T09 [s] T09 = 40 (Q > 1 l/min)
Software / programming
Flow monitoring; quantity meter; Preset counter; Temperature monitoring;
Parameter setting options hysteresis / window; normally open / closed; switching logic; current/
voltage/pulse output; Start-up delay; display can be deactivated; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port class A
Process data analog 3
Process data binary 2
Min. process cycle time [ms] 4
Type of operation DeviceID
Supported DeviceIDs
default 671
Operating conditions
Ambient temperature [°C] -10...60
Storage temperature [°C] -25...80
Protection IP 67
Tests / approvals
EMC DIN EN 60947-5-9
model number 007MI
accuracy class -
maximum allowable error ± 2,5 % FS
CPA approval
Q (min) 0,0003 m³/h
Q (t) -
Q (max) 0,18 m³/h
Shock resistance DIN IEC 68-2-27 20 g (11 ms)
Vibration resistance DIN IEC 68-2-6 5 g (10...2000 Hz)
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request

ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SM4000-00 — 03.08.2021 —
SM4000
Magnetic-inductive flow meter
SMR14DXXFRKG/US-100

Mechanical data
Weight [g] 536.5
Material stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts) stainless steel (1.4404 / 316L); PEEK; FKM
Process connection threaded connection G 1/4 DN6 flat seal
Displays / operating elements
Display unit 6 x LED, green (ml/min, l/h, l, m³, °C, 10³)
Switching status 2 x LED, yellow
Display
Measured values alphanumeric display, 4-digit
Programming alphanumeric display, 4-digit
Remarks
MW = Measured value
Remarks
MEW = Final value of the measuring range
Pack quantity 1 pcs.
Electrical connection
Connector: 1 x M12; Contacts: gold-plated

ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SM4000-00 — 03.08.2021 —
SM4000
Magnetic-inductive flow meter
SMR14DXXFRKG/US-100

Connection

Colors to DIN EN 60947-5-2


OUT1:
- Switching output Volumetric flow quantity monitoring
- Pulse output quantity meter
- signal output Preset counter
- IO-Link
OUT2:
- Switching output Volumetric flow quantity monitoring
- Switching output Temperature monitoring
- analog output Volumetric flow quantity monitoring
- analog output Temperature monitoring
- Input counter reset
Core colors :
BK = black
BN = brown
BU = blue
WH = white

ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SM4000-00 — 03.08.2021 —
SM4000
Magnetic-inductive flow meter
SMR14DXXFRKG/US-100

Diagrams and graphs


Pressure loss

dP Pressure loss
Q volumetric flow quantity

ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SM4000-00 — 03.08.2021 —

You might also like