A.
Rak Wärmetechnik GmbH
Heat Technology
Twin-heating cable for outdoor use, one connection cable, 30 W / m
TWIN-heating cable for outdoor use
Deployable exterior as radiant panel heating..
The heating cables can be laid in any configuration under all floor
coverings that are suitable for underfloor heating.
The power output per m² of the TWIN-heating cable can be freely
selected and therefore allows optimum heat adjustment to the
required temperature.
Completely converted, with 1 x 3 m PTC resistor.
UV-resistant outer sheath
Deliverable in the length from 14,0 m up to 205,0 m.
Manufactured in compliance with the VDE-standards (DIN EN60335-
2-96 / DIN EN60335-1 / DIN EN50366 ).
Laying schedule: Construction of the cable
After the selection of the specific power per sqm, you find the distance of
the meander (mandatory). In the column above you find the heatable
surface in sqm. 5 4 3 2 1
1 Twin-heating conductor, forward- and return
Article-No. Type Length Power conductor run parallel and are made from
30-6101 / 400 6101-30 14,0 m 430 W strand (no rigid wire)
30-6102 / 400 6102-30 21,0 m 665 W 2 Primary insulation: FEP (Teflon®)
30-6103 / 400 6103-30 28,0 m 850 W
3 Multi-overlapping polyester-insulation
30-6104 / 400 6104-30 35,0 m 1060 W
30-6105 / 400 6105-30 50,0 m 1500 W 4 Protective conductor: copper braid, tinned
30-6106 / 400 6106-30 64,0 m 1920 W 5 Outer sheath: PVC
30-6107 / 400 6107-30 75,0 m 2240 W
Technical data
30-6108 / 400 6108-30 86,0 m 2570 W Voltage: 400V AC
30-6109 / 400 6109-30 99,0 m 2980 W Nominal limit temperature: 80° C
30-6110 / 400 6110-30 114,0 m 3430 W External diameter: 5 mm
30-6111 / 400 6111-30 127,0 m 3810 W Specific heat output per m: 30 W
30-6112 / 400 6112-30 145,0 m 4360 W Resistance tolerance: +10% / -5%
Supply line: 1x3m
30-6113 / 400 6113-30 163,0 m 4900 W
Protection category: IPX7
30-6114 / 400 6114-30 181,0 m 5445 W Minimum bending radius: 6 x dA
30-6115 / 400 6115-30 205,0 m 6150 W
Laying Schedule heated surface qm
Art. Nr. 150 160 180 200 220 240 250 280 300 350
W/ qm W/ qm W/ qm W/ qm W/ qm W/ qm W/ qm W/ qm W/ qm W/ qm
30-6101 / 400 2,9 2,7 2,4 2,1 1,9 1,78 1,71 1,53 1,43 1,22
30-6102 / 400 4,4 4,1 3,7 3,3 3,0 2,8 2,7 2,4 2,21 1,90
30-6103 / 400 5,7 5,3 4,7 4,3 3,9 3,5 3,4 3,0 2,8 2,43
30-6104 / 400 7,1 6,6 5,9 5,3 4,8 4,4 4,2 3,8 3,5 3,0
30-6105 / 400 10,0 9,4 8,3 7,5 6,8 6,3 6,0 5,4 5,0 4,3
30-6106 / 400 12,8 12,0 10,6 9,6 8,7 8,0 7,7 6,8 6,4 5,5
30-6107 / 400 14,9 14,0 12,4 11,2 10,2 9,3 9,0 8,0 7,5 6,4
30-6108 / 400 17,1 16,0 14,3 12,8 11,7 10,7 10,3 9,2 8,6 7,3
30-6109 / 400 19,9 18,7 16,6 14,9 13,6 12,4 11,9 10,7 9,9 8,5
30-6110 / 400 22,8 21,4 19,0 17,1 15,6 14,3 13,7 12,2 11,4 9,8
30-6111 / 400 25,4 23,8 21,2 19,0 17,3 15,9 15,2 13,6 12,7 10,9
30-6112 / 400 29,0 27,2 24,2 21,8 19,8 18,1 17,4 15,6 14,5 12,4
30-6113 / 400 32,7 30,6 27,2 24,5 22,3 20,4 19,6 17,5 16,3 14,0
30-6114 / 400 36,3 34,0 30,2 27,2 24,7 22,7 21,8 19,4 18,1 15,6
30-6115 / 400 41,0 38,4 34,2 30,7 27,9 25,6 24,6 22,0 20,5 17,6
Distance of m eander 20,6 19,3 17,1 15,4 14,0 12,8 12,3 10,9 10,2 8,7
A. Rak Wärmetechnik GmbH, In der Luxhohl 5, D – 63303 Dreieich, info@rak-waermetechnik.de, www.rak-waermetechnik.de