omRon
PROFESSIONAL
BTOOD PRESSURE
MONITOR@
@
**"
f'ffifli
,,qi
Alt for HeaLthcare
EASY-TO-TJSE
eLitor-ffimtie blmmd pres$ur& momi
/ fon use by meCicm! profe$$imm&
f'
S'
W,
Fdopain in the hands and ears fnsm
repetit!ve use
Reduce individual differenee in
rn eas Li rern ent r-l-r eth od
* hio risk of rne!"cury leakage
COMPAGT DESIGN
SIMPLE OPERATION
l-arge stad button with 2 other
buttons for auscultation and pcwen
on/off. The device nealizes simple and
enhanceC usability at the serne time.
BATTEHY OR AC OPEHATION
The device can operate using 4 'AA'
batteries or AC power"
EASY TVIAINTENANGE
The deviee and cuffs can be eleened
easily witf"r a soft cioth nroistened
with alcohol.
EASY.TO.USE
Designed fon routine blood pressure
measuren"rents cn yoLu" patients"
omRon
tor intended
S
Desrgtned for use in clinics,
doctar's affice, hospitals
and medical facilifles
USER-FRI EN DLY FU NCTIONALIry
DUAL MEASUREMENT MODE MOTION STOP FUNCTION
Users can choose from two measurement When body movement is detected, the
rnodes-oscillometric measurement and device stops deflation for 5 seconds.
auscultation ( ele ) method with the latter
using stethoscope. IRREGULAR PULSE INDICATOR
Helps identify changes in heart rate,
ZERO INDICATOR FUNCTION rhythm, or pulse which may be caused by
Provides medical professional the added heart disease or other serious health
assurance of the device's pressure issues. The icon is also displayed when
accuracy. The indicator lights when ozero body mo\rement is detected during
calibration' is being performed prior to measurement.
blood pressure measurement. The device
displays "OK" sign when it is ready 5 CUFF SIZES AVAILABLE FOR
for measurement. MEASUREMENT
The unit can be used on pediatrics of age
3 years and above. Cuff sizes available for
use on different arm circumference:
XL: 42-50crn, L: 32-42cm, M'.22-32cm,
8:17-22cm, S$:12-18cm
Main Unit
Measurement Parameter NIBP, PR
Dimension Main unit: 130 x 175 x 120 (mm)
5.12 x 6.89 x 4.72 (inch) (WxHxD)
AC adapter: 55 x 25 x 70 (mm)
2.17 x 0.98 x 2.76 (inch) (WxHxD)
Weight Main unit: Approx. 510 g (not including accessories
and options)
AC adapter: Approx. 42 g
Display 7 segment LCD
Safety Standards IEC60601 -1 :1 988+A1 :'1 99'l +A2:1 995
Medical electrical equipment-Pad1 :General
requirements for safety
Protection Class Class ll
lnternal powered equipment
Deqree of Protection Type BF
Power Supply
AC adapter lnput voltage range: AC 100 V to 240 V
Rated Current: 0.5 A
Freouencv: 50/60 Hz
Output voltaqe ranqe: DC 6 V t5%
Dry cell battery Type: AA batteries, x4
Number of measurements: 250 OPTIONAL ACCESSORIES
. Measurement conditions Fits 42-50cm arm Fits 32-42cm arm
- New battery (AA high-performance manganese) circumfe16nce circumference
- Ambient temperature of 23"C (73.4"F)
- Using M-size cuff
- sYS120 / DlA80 / PR60
- One 5-minute measurement time consisting of
"cuff measurement time + wait time" AC adapter GS CUFF XL GS CUFF L
60240HWsSW HXA-GCUFF.XLLB HXA-GCUFF-LLB
Fits 22-32cm arm Fits'1
7-22cm arm Fits 12-'l8cm arm
Environmental Conditions circumference circumference circumference
Environmental Conditions Temperature range:5 to 40"C (41 to 104'F)
Humiditv ranoe: 15 to 85%RH (not condensed)
Atmospheric pressure: 700 to 1060hPa
Storage and transportation Temperature range: -20 to 60"C (-4 to 140"F) GS CUFF M GS CUFF S GS CUFF SS
HXA-GCUFF-MLB HXA-GCUFF-SLB HXA-GCUFF.SSLB
Humidity range: 10 to 95%RH (not condensed)
Atmospheric pressure: 500 to 1060hPa STANDARD PACKAGE CONTENTS:
EMC: Reference standard 1EC60601 -1 -2:2007 Main unit HBP-1.100, GS Cuff M, AC adaptor,
Medical electrical equipment - lnstruction Manual
Parl 1-2: General requirements for basic safety and
essential performance - Collateral standard:
Electromagnetic compatibility - Requirements and tests. SELECTING THE CUFF
Measure the circumference of the patient's arm
Non-lnvasive Blood Pressure (NIBP) and select the cuff size that is appropriate for the
Measurement technoloov
circumference,
Pulse rate accuracy
It is important to use the correct sized cuff for a
Measurement method Dvnamic Linear Deflation method
patient in order to get an accurate reading.
Pressure disolav ranoe 0 to 300 mmHg
Select the cuff that is suitable for the patient from the
Pressure disolav accuracv Within t3 mmHo or 2 o/o
cuffs below.
NIBP measurement range SYS 60 to 250 mmHg
DIA 40 to 200 mmHg
PULSE 40 to 200 /min
NIBP accuracy- Maximum mean error within +5 mmHg
Maximum standard deviation within 8 mmHo
Pulse rate accuracv Within t5 %o of readinq
Reference Standard: ANSI/AAMI SP-1 0:2002+41 :2003+M: 2006/(R)2008
1S081060-2:2009
* -Available as an optional accessory.
Comparison with auscultation method performed by a trained professional.
DIA determined by the auscultation method is "K5".
oMRON FIEAI-TI-ICARE Co", Ltd. A,sia Pacific HQ PT. OMRON HEATTHCARE INDONESIA
53, Kunotsubo, Terado-cho, OMRON HEATTHCARE SII",IGAPORE PTE LTO. Menara Bidakara 1, Lt. 22
Muko, Kyoto, 617-0002 JAPAN 438A Alexandra Road, #05-05108 Subroto Kav. 71-73
Jl. Jend. Gatot
A.lexandra Technopark, Singapore 119957 Jakarta 12870 www.omronhealthcare.co.id
www.omronhealtheare-ap.corn PHOltlE : (021) 2949 7500
!f omronhealthcareindonesia
ffil omronhealthcaretD
Email: ohsid_feedback@ap.omron.com
( ( 0197