TS-303 English

The document describes a fixed type gas detector with three models for detecting different gases. The TS-303A detects combustible gases, the TO-303 detects oxygen, and the TK-303 detects toxic gases. It has standard features like corrosion resistance, trip-proof construction, and alarm contacts. It can detect various gases with high accuracy and fast response times.

Uploaded by

SM OHN
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
201 views4 pages

TS-303 English

The document describes a fixed type gas detector with three models for detecting different gases. The TS-303A detects combustible gases, the TO-303 detects oxygen, and the TK-303 detects toxic gases. It has standard features like corrosion resistance, trip-proof construction, and alarm contacts. It can detect various gases with high accuracy and fast response times.

Uploaded by

SM OHN
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Fixed Type Cas Alarim

Combustible Gas Alarrn TS-303


Oxygen Gas Alarrn TO‐ 303
Toxic Gas Alarm TK-303

TOKASEIKICO.′ LTD.
Design based on new thought.
303 series has become complete by three kinds such as combustible gas,oxygen and toxic gas
丁his is fixed type gas detectorllvith one detection points.
The rnain body design is standardized and 9ood appearance.

System configuration
lndicating alarm unit 303 series

■I(Dutstanding corrosion
resistance and insulation
properties(Resin body)
■II⊃ rip… proof construction
■ With dirrlmer function
萎 ■ Extension alarrrn contact
(dry)



■ 4… 20mA Signal output
1

錮沐 瘍
(OptiOn)

Detection unit

i3c i3c 12c 12c


J曇 │■ 1,‐ │
鶴 ..

1纂 │

「品儡めIII:::│ ※ We tt d prttde釧 引
m type aS W酬
碁 椰 鎌lRIr認 意稲
1憲 じ


旧StthЫ J∝ hё 銀 酬 的 ed he樋
きFtte5e‐
and blackdamp from the OaS rrlahufacturer,gas "b率 l景聯
gas consumption utilities,vessel,stockp‖ ing ba( 囁 Hles

SPECIFiCAT10NS/303 SERIES
M● del TS‐ 303A TO‐ 303 TK4303
Measurement Cas General Combusuble Gas(・ 1) Oxygen Tox c Gas(☆ 2)

Principle Catalytic Combusion Galvanic Ce‖ Electro Chemical

●〓■
Measurement Range Oγ 100%LEL 0∼ 25%02 Please referto table of rneasurement gas

Accuracy Wnhin± 576 of fu‖ scale wnhin± o7%02 Wnhin± 5∼ 10%of full scale
More than 1/10 offu‖ sCale

Alarm SetJng Leve More than 1/10 offu‖ scale More than lノ 10 offu‖ scale

Accuracy of Alarm Wnhin± 25%of alarm setting level VVithin± 2596 of alarm setting level vvnhin± 2596 0f alarm seting level
Respohse Speed Within 30 second response(☆ 3) VVithin 1 0 second 90,6 response VVithin 30 second response(・ 3)

Env ronmental Cond面 on -10℃ ∼50℃ under 95%RH 0℃ ∼40℃ under 95%RH 0℃ ∼40℃ under 85%RH
Power AC100V,50/60Hz(aVai able for DC1 2V,DC24V)AC100V,50/60Hz(aVa‖ ab efor DC12Ⅵ DC24V)AC100V,50/60Hz(aVal able for DC1 2V,DC24V)
External Alarm Contacl Extension Alarm Contact(dry)lC Extension Alarm Contact(dry)lC Extension Alarm Contact(dry)lC

indicaing Lamp Ac■ on lndication:Green Action indication:Green AcJon lndication:Green
Alarm indicalon:Red Alarm lndicaJon:Red Alarm lnd ca■ on:Red

Defect lndication:Red Alarm lndication:lntermittent buzzer Alarm indication:intermittent buzzer

Audible Alarm Alarm indication:lntermntent buzzer


Defect indication:Constanttone
Option l Recorder output(0-100mヽ ち4-20mA etc) 3 Two level alarm output(la Orlb)
※ n cOuld nOtbe combined wnh l and 2 or3 and 4
2 Addnional meter output(0-500μ A) 4 The second contact point output(la Orlb)
*l A general combuslble gas is propane,butane,CNG,LNG,and an ethanol,etc
*2 Please referto the attached table(gas for detection)forthe toxic gas
*3 With using gas of 160%densly for alarm setting level

Wa‖ ―mounted type Flush― mounted


Flush― n∩ (type

V
Pane cuting d mens on

Flush― mounted type with three point combination

Pane cutung d mens on

0 李 ●
ⅢII'議ⅢⅢI 丁LV Meas range
(ppm) (ppm)
As referto atached table
CO I■ ││IⅢ ⅢMOn。_。 xld │● :■ │15o
10 0-30
VVithin ten seconds of Within 60 seconds(★ ) NH■ ■■ Ⅲ de■ ││■ 1´ ││■ │■ 75

90°/O respOnse level


Hcl Ammonia 5 0∼ 15
'IⅢ
ltis possible to setit voluntarily by 1/10 or rnore offu‖ ―
scale (AL2 is set separately)
Ci2 lyす 。
gen,hfOrlde ■11■ │■ │‐
3
VV■ hin± 25%of alarm seting level(AL2 is set separately) HF Chlorine 3 0- 9
AC125V、 3A HCN■
Representauve contact(ALl,AL2):lc orla、
05A
■■Hydrogen甲 111111111130
lndividual oontact:(ALl,AL2):la、 AC125V、
PH3 Hydrogen Cyanide03 0∼ 1
Red LED b‖ nking and intermittent buzzer "lde
S021111Ⅲ OSpl■ ■■│ 1111110∼ 115
5 0∼ 15
4∼ 20mA(Load resistance 250 0)
N021■ Acetl“ │■ ■ ■●│││10■ ‐ 3o
CH3NH2 Nitrogen Dioxlde 10 0∼ 30
AC100V50/60Hz(Available for ACl10V AC220V,DC12v and DC24V) Br2 11111111,│IⅢ ⅢIII 111111111101110
AsH3 Bromine 0.3 0∼ 1
375(W)X384(H)Xl10(D)mm (ln Case of six points type)

)W th using gas of 160,6 density for alarm setting level


は││■ ■IⅢ Ⅲ
I■ ■ │ 111111111113
3 0∼ 10
(★

(clし ,:ヽ ││■ IDlboralllll■ ││ 111111111∼ 130


● Emergency DC―AC inverter Specrica10n SiH4 3 0∼ 10
Si2H6 Sila■ ■■│ 1● │││■ 10
Si3H8 3 0∼ 10
AC100V(Commercial power)
AC100V(Sine‐ Wave)、 50Hz(n is possib e to specify 60Hz)
BF311 十llsilanざ ││■ │ 1111110115
About tWO years 3 0∼ 15
One hour(in Case rated loading 60Ⅵ ′
) One hour(in Case rated A,FIII■ ││■ IⅢ Ⅲl■ ¨ 1111:│││││││15
02 Arsenic 18%02 0∼ 25%02
380(W)X310(H)X169(D) 480(W)× 400(H)× 212(D)

:::jrll111:;}「 1+│││ 1篤 IT

Emergency 5000 settes


DC― AC inverter Wa‖ ‐
mounted type
TPK-20WISi) TU-5000(W)

※Specifications are subject to change without any prior notice

MANUFACTURED BY: DISTRIBUttED BY:

TOKA SEIKICO口 ′LTDロ


3-239-2,Kosugi,Nakahara― ku,
Kawasaki,」 APAN
211-0063
PHONE:+81-44-722-2000
FAX :+81-44-722-7460
E―ma‖ :sales@toka¨ selki.co.jp
http://www.toka― selki.co.jp
T0609012(N)