Larco Docil Anglais
Larco Docil Anglais
Petroleum Equipment
                       REFERENCES
                 More than 30’000 units in operation
                                                                                                                                         Petroleum Equipment
                                                                                                                                                                                                               Petroleum Equipment
                                                                                                                                • 4 LED or indicators
                                                                                                                                • 2 reference marks A and B
- Detection loop certified SIL2/SIL3 from detector to relay contact                                                             • a screw (adjust the impedance of the board
- ATEX approved                                                                                                                 Distance between the board and the level detector)
- Level alarm setting on site
- 2 separate level alarm on the same flange
- Easy complete and real test without any dismantling
- More than 30,000 detectors in use today
- LPG detector can be maintained without emptying the sphere
- Very high reliability, maintenance free no moving parts
- Response time less than 20 ms
- Precision : better than 1mm
- Continuous Auto check and loop control integrity
                                          Sensor L1, HL :                                                                                                                            Liquid is injected through the orifice specifically located at the
                                          High level, first safety level                                                                                                             head of the level detector.
                                          (this level should never be reached)                                                                                                       The liquid received into the test cups immerses the sensors
                                          • alarm the depot and the operator                                                                                                         => Alarm
                                                                                                                                 BLACK                             GREEN             The cups then empty itself slowly into the tank by a small hole
                                          • time-lag stop of the reception                                                       L1 (HL)                           L2 (HHL)
                                          • stop of pumping by the operator pipe                                                                                                     located lower than the inlet.
                                          • stop discharge pumps from rail reception
                                          • Stop of the ship pump by the boatman