0 ratings0% found this document useful (0 votes) 3K views34 pagesJhs
Portable Aircondition Manual - JHS
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here.
Available Formats
Download as PDF or read online on Scribd
ORS
MANUAL
PORTABLE AIR
CONDITIONER
MODEL NO. A016-10KR/B1 Wi
CCS u ee
eeu eu seer)
rns
RCO Ree enue as
CCUINTRODUCTION
DESCRIPTION OF UNIT AND PARTS.
SPECIFICATIONS
IMPORTANT SAFETY INSTRUCTIONS
Installation and operation
Electrical safety... +e ee eee eee a
INSTALLATION INSTRUCTIONS
Suggested tools for installation
Selection of installation location
Attaching exhaust hose
Window kit installation
Connect hose to window kit
Check the sealing
OPERATION
Inserting batteries inthe remote «++ +s eee eee eee eee eee eed
Using the remote controls sss see tee eee tee eee eee eee et
Control panel and remote keypad
JHS Smart (Wi-Fi) Guides -- +--+ see
Water drainage.
Protection function of JHS portable air conditioner» +++ +++ +++ ee eeee 27
CARE AND CLEANING
Cleaning the case
Cleaning the filter
Start-end of season operations: +++ +++ seer eee eee
TROUBLESHOOTING
Before you call for service »
WARRANTY
4JHS portable air conditioner li
dwarranty ++DESCRIPTION OF UNIT AND PARTS
o—_——s
@ tance —@ Air-outier crite B Exhaust connector drainage Hole
@ controtpanei @ castor ® Power cord
@ Airoutiet © FilterFrame Upper @ Filter Frame Lower
Air Exhaust Hose Hose Outlet Hose Inlet Remote Control
Window Panel ScrewA
Ss" 7 Baintions
ee re
Nh ee
7SPECIFICATIONS
Model A016-10KR/B1 . Fan Speeds 2
Control Type Touch button +Remote | WiFi ves
Energy Efficiency Ratio(EER) 2.61ClassA Swing ‘Automatic two-way directional
Cooling Capacity 100008TU | Timer yes
Noise Level <544BA AirFilter Washable
Power Consumption 1280W 11.1A | Drain Options Continuous and manual
Estimated CoolingArea__220sq.ft(20m') max | Water-full Indicator Yes
Temperature Range 61°F~88°F UnitDimensions 14" Wx 13.3°Dx27.8"H
Dehumidifying Capacity 50.7pints/ day Unit Weight 50lbs
‘Amount OF Air Moved (CFM Max.) 205CFM Refrigerant RAIA
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
Your safety and the safety of others are very important. Incorrect operation due to ignoring instruction
will cause harm or damage. The seriousness is classified by the following indications.
We nave provided many important safety messages in this manual and on the appliance. Always read
‘and follow all safely messages.
This is the safety alert symbols.
RGN Failed to follow the instructions could result in death or serious injury.
PRIME | Files to folow theinstructios couldresultin personal injury or property damage,
( ®@ BE SURENOTTODO
{ °e BE SURE FOLLOW THE INSTRUCTIONS.IMPORTANT SAFETY INSTRUCTIONS
POMS
To reduce the risk of explosion, fire, death, electric shock, scalding, or personal injury when
using this appliance, please observe the following basic precaution:
NEU
+ Some parts wiht sharp edges may cause _« The portable air conditioneris aheavy
injury. So glovesare highly recommended _object, which needs two or more people to
for unpacking and installing, liftand install. Failed to do may resultin
Injury or other accidents,
Oe @e e
= 7
+ After installation please store the carton, _* This appliance is not intended for use by
plasticbag, and otherpacking materials in persons (including children) with reduced
a safe place to avoidchildren's contact. _physical, sensory or mental capabilities,
Packing materials can become airtight ‘or lack of experience and knowledge unless
chambers. they have been given supervision or
Instruction concerning use of the appliance
by the person responsible for their safety.
ea
SET.»
earronl SG
ba
“Neverattemptto operate this appliance if + Donot repair or replace any partof the
itis damaged, malfunctioning, partially appliance. All repairs and servicing must
disassembled orhas missing orbrokenparts, __be performed by qualified service personnel
including a damaged cord or plug. Use only authorized JHS factory OEM parts.
@
\IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of explosion, fire, death, electric shock, scalding, or personal injury when
using this appliance, please observe the following basic precaution:
EU ee
+ Keep the product away fromfire. Donot —_* Donot use heating equipment near the
store or use flammable gases or materials appliance.
near the appliance.
+ Inthe event of a gas leak (propane gas, _« Onlyuse the appliance in an upright position.
LP gas,etc.)donot operate this or any other Make sure the angle of inclination 10°
appliance. Gpenawindow ordoortoventilate Always place the appliance on a stable, fat,
the area immediately, level surface to prevent the air conditioner
from overturning,
@
s
aIMPORTANT SAFETY INSTRUCTIONS
INSTALLATION AND OPERATION
+ Read all instructions before using the
appliance and save these instructions.
+ Power on this appliance in strict accordance
with ELECTRICAL SAFETY guide
(Page 07.)
+ Keep the air inlet and outlet free of
obstructions.
+ Do notuse this unit in places exposed to
direct sunlight, wind or rain.
+ Before cleaning or maintenance operations,
always unplug the unit from the outl
+ Ifthe product has been submerged, contact
the JHS customer service center for
Instructions before resuming use.
+ Ifthe product makes a strange noise or
emits a smell or smoke, pull the power
plug out and contact the JHS customer
me
* Donot place heavy objects (>3KG) on top
of the air conditioner.
eoIMPORTANT SAFETY INSTRUCTIONS
«Donotplace containers with liquids onthe _* Do not use the product in places where it
unit could be splashed by water.
“Donotuse watertocleantheairconditioner. _ + Do not insert or place fingers or objects
into the air discharge area or rear grille of,
the unit
+ California Safe Drinking Water and Toxic Enforcement Act
‘This product contains chemicals known to the State of California to cause cancer and
birth defects or other reproductive harm. Wash hands after installation.
°IMPORTANT SAFETY INSTRUCTIONS
POMS
COME Ue heats
ELECTRICAL SAFETY (High voltage appliance)
eC eee
Sree
ee ea ee mee ee ey
rer
Pee Cate ee ety
Penne che ot
+ Do not cover the power cord with a rug or carpeting,
Pee cent eeu cn
See ern er een
Push the power plug all the way into the wall outlet so that itis not
ays grip the plug firmly and pull straight out from the outlet when taking
er pl ieee
oe eee ect
Never use the appliance if the outlet is damaged or loose.
orIMPORTANT SAFETY INSTRUCTIONS
POMS
COME Ue heats
ELECTRICAL SAFETY (High voltage appliance)
+ Do not use multiple-outlet power strip or extension cord with this appliance
Poeun te ee ot
Peete
Seen ceter ee on
LCDI INTEGRATED CIRCUIT BREAKER GROUNDING METHOD
Follow 4 steps on the LCD! plug
‘case, ifthe TEST button does
otcause the circuit breaker trip
‘of the RESET button willnot stay
‘engaged, unplug the air
conditioner immediately and
contact JHS customer service Ensure proper ground
center. exists before use
Re ee eae any
eet ee eetNEW a eile) ML EME Le)
IONS
SUGGESTED TOOLS FOR INSTALLATION
+ Screwdrivers (medium size)
‘Tape measure or ruler
= Knife or scissors
+ Saw (In the event that the window kit needs tobe cut down in size because the window is too narrow for direct
Installation)
SELECTION OF INSTALLATION LOCATION
© Place the unit near a window.
@ Forest perfomance, allow atleast 20inch (soem)
ota spaceonallsdes ofthe untforgoodalrcieulaton, 20ineh
au
ATTACHING EXHAUST HOSE
Install the plastic hose with window bracket adapter and hose connector on both sides. Ensure proper
fiton both ends.
The supplied exhaust hose can be extended to S8inch max
(Stretch both ends ofthe exhaust hose out for 10-15em)
i Lock unLock
Push the plastic hose into the hose connector on the back of the unit
Keep gently and horizontal to avoid getting stuck.Ne
EPMO eRe)
1ONS
ATTACHING EXHAUST HOSE
Note
The length ofthe exhaust hose is specially designed for the unit. Do not replace or extend it with another
hose as this could cause malfunction. Do not block airflow around the air conditioner. The exhaust hose
‘should be free of any obstructions.
Abent hose will block exhaust air and cause the unit to malfunction or shut-off.
NOT RECOMMENDED RECOMMENDED
WINDOW KIT INSTALLATION
Your window slider kithas been designed to ft most standard "Vertical and “Horizontal” window applications,
however, it may be necessary for you to improvise / modily some aspect ofthe installation procedures
for certain types of window. Minimum and maximum window openings
Maximum: 57° (145 em)
wii 9 (Sem A
m= TALS oT rg EEE tiem
inion ap | 18"| 21" 21" 8
8 Z a —— rr
138 ra » c
39-57 vtrte Sar (sen)
NOTE:
+ Adjust to the desired length and use provided metal wing nuts and bolts to secure.
+ Ifthe window opening is less than 18" the minimum length of the PanelA, cutA with the hole init
short fo fit for the window opening.
+ Never cut out the hole in Panel A
Fig.a
Sineh-18ineh
For a 9°-18" window opening, use panel A
(Cut shortif necessary)
8ineh-18inenea
Wie) MN Suid
1ONS
WINDOW KIT INSTALLATION
Fora 19°-38" window opening, use panelA*B For a39"-57" window opening, use panelA+B+C
(Cut short 8 itnecessary)
Fig.b Fig.c
Fea LO
The air exhaust hose must be installed or removed from the portable alr conditioner in accordance with,
the way itis being used:
2, Slide ie forlocking 3. Frthe connection fiemly, locking the type screw.ea
Wie) MN Suid
mie)
re
Cut the foam seal to the proper length, then attach it to the window frame or panel for sealing,
oI Tile)
(NEN
@ Press and glide the battery cover
‘onthe rearoftheremote, remove
the cover, Make sure the polarity is correct
@ insert wo new R03 "AAA" 1.5V
batteries into the batery compar TEE
tment Make sure the polarity Is ea]
correct,
@® Battery isnotincludedin he pack-
age because of transportation
safely.
NOTE:
+ Donot mix old and new batteries. Do not mix alkaline, standard (carbon-zinc) or rechargeable batteries.
+ Ifthe remote contro! is not be used fora certain length of ime, remove the batteries (Batteries may
explode orleak).
+ Ifthe remote control unitis replaced or discarded, the batteries must be removed and disposed of
in accordance with current legislation as they are harmful o the environment.INSTALLATION INSTRU
1ONS
WEN oe
Point the remote control to the air conditioner. The remote control must be no more than 16Ft(5 meters)
away from the appliance (without obstacles between the remote control and the appliance).
The remote control must be handled with extreme care, Da not drop it or expose it to direct sources
of heat, sunlight or water
MAX 16 ft
er 5 meters
Weed
OPERATION
Qn
re ”
6e@e@
eee
Power button ‘Swing button
@ Up button @ Cooling button @ Mode button @ Timer button
® Down button ® Dehumiditying button @ UP button @ steepmodebutton
@ Fan button @® Low speed button @down button GH Swing button
© Timer button @ High speed button
@ Sieepmodebutton @ LCD displayOPERATION
nee
Se)
OPERATION OF FUNCTIONS IS THE SAME WHEN USING REMOTE OR CONTROL PANEL, UNLESS
OTHERWISE STATED.
11. When the machine is powered on for the first time, the buzzer will sound "power-on" tone, and then
the unit will get into standby status. LCD displays current TEMP,
2.poverbuton ©)
Press the key totum on and tur offthe unit. In the case of power on, press the key to turn off the machine
inthe case of power off, press the key to turn on the unit
3. Mode Selection
Inthe case of power on,
>Press the key on the uint panel to choose
Q ootina) © ehumisityingy GB (ran)
> Pree tekey onthe remote ©) to ston between Cooing-- Dehumisiying Fan mode
4. Upbutton and Down button @Y @®
Press the two keys to change the temperature setting value, operation procedure as follow:
While setting temperature, press up key or down key to select the required temperature (Non-available
in Fan or Dehumidifying mode). Adjustable between 61°F ~ 88°F (16°C~31"C)-Simultaneously press
both keys to switch between Celsius (°C ) and Fahrenheit (*F)
5. Fan Speed Selection
> Pree ne key onthe remote @) such belweenhigharlow wind speed
In Dehumiifying mode, pressing the key is non-effective, and the fan will forcibly choose low wind
speed operation.OPERATION
OPERATION OF FUNCTIONS IS THE SAME WHEN USING REMOTE OR CONTROL PANEL, UNLESS
OTHERWISE STATED.
6. Timer
In the case of power on and the unitis turn off, press the key to set time for turning on the unit
In the case of power on and the unitis turn on, press the key to set time for turning off the unit
Press this ay, when the timing symbol ashes (Hounds, nen ores @) @ toselectne
‘Timing values can be set within 01-24 hours and the timing value is adjusted by one hour.
Timing mode can be turned off by set time values 00 or power of.
1-steopmose()
In the cooling mode, press the key to enter the sleep mode, the unit wll work on energy-saving and
quiet mode.
Sleep mode is non-effective in the Dehumidifying or Fan mode.
EE ee
Using this JHS smart APP you can control the portable AC unit via an iPhone or Android smart phone
anywhere, even outside of your home, for example, in office, airport ete,
2 route
‘Supported wi must working with
Operating Frequency: 2.4 GHz
‘Standard: IEEE 802.11b/g/n
‘Supported smart phone system:
Android 4.1 or later
108 8.0 or later
NoTEs:
+ The Wi-FIAPP is only compatible with smart phones and is not available for laptops or tablets.
+ APP may not support the latest version of Androidor iOS system because of the test of stability
‘Also may not compatiblo with tampered Android or IOS systom.
+ Due to different network situation, sometimes, request time-out could happen, itis necessary t0
do network configuration again.
+ Due to different network situation, the control process may retum time-out(0S-60S) sometimes. In this,
situation, there may be some differences between the display of control panel and APP.
+ Continuous Power-on8of wl be no response because of protection uncon of campressor(3-minute delay).
+ Allthe illustrations in the manual are for explanation purpose only. The latest APP may be slightly
different. The actual shape shall prevail
+ The mobile APP will continue to be updated with design and content improvements. Check for update
at the Play Store or the App Store. ouOPERATION
OPERATION GUIDE
@ Please ensure your mobile device is connected to WiFi router. Algo, the WIFI outer should already
be connected to Internet before doing user registration and network configuration process,
© Downtoad and install APP: @rodgistration
Sean Rode onthe controlpanelorsearch Open JHS smart APP start Register
JHS smart in
ReghsterOPERATION
OPERATION GUIDE:
Registration
Fill in your mobile number or e-mail address.
Click Next and wait a moment (1-10 minutes)
gh
@ zxcvbnam @
wo space oturn
Enter the verification code which is sent from
JHS service center via SMS or email then set
‘password by yourself. Click Confirm tofnish
registration,
‘six-digit verification codeOPERATION
OPERATION GUIDE:
© Adda now JHS smart unit.
Insert power plug to keep unit be standby,
“Touch the WiFi button on the unit panel for 5
‘seconds until LED indicator keep continuous
flashing.
Back to home page, click Login
Fill in your mobile number or e-mail address.
Fill in your password and finish login.
ot.OPERATION
OPERATION GUIDE:
© Add anew JHS smart unit
Select your corresponding device
Power on the device and confirmOPERATION
Een ere
OPERATION GUIDE
® Adda new JHS smart unit
Fill in the WiFi passward and confirm
confirm
qwertyu
asdfghjkt
IS zx cvbanm @
Connecting NowOPERATION
OPERATION GUIDE:
@ Add anew JHS smart unit,
Succesfully Added 1 Device(s)
share with FamilyOPERATION
OPERATION GUIDE:
‘® Now you can contro! the unit to set your room temperature whether you are driving on road or
at the office.
‘Turn your JHS air conditioner on and off Change working modes Set the temperature
maOPERATION
Een ere
OPERATION GUIDE
© Now you' have the control youneed to set your room temperature whether you're driving on the
road oratofice.
Set fan speeds for comfort and Sel schedules to programme a customized timer
energy savings.
Function
°°
ConfirmOPERATION
EEE Were
OPERATION GUIDE
‘© Now you't have the control you need to set your
room temperature whether you're driving on the
road or at office.
sunday
Monday
Tussday
Wednesday
FridayOPERATION
OPERATION GUIDE
© Spociai Functions €€.9._ Share the unt to your famiyo fiend which
instaled JHS smart APP, tel ther to fnish login,
then come true mut-user conto
Moy Device Name noTest
Check The Network Check Now
Device nfo
Create Grou
Check for Firmware UpdateWee
Caen
Re
JHS portable air conditioner has a self-evaporative system. The condensed water willbe recycled to
the working compressor and evaporator, most of the water will be evaporated. This work procedure
can not only improve cooling efficiency but also save energy for all customers.
Since most of the condensed water will be used to aid the compressor, there is no need of drain hose:
Ingeneral using environment,
youuse the portable air conditioner for cooling or dehumidifying ina high humidity situation (Relative
humidity >25%, like New Orleans, Louisiana, Jacksonville, Florida, Houston), the collected excess.
water will need to be drained through a drain plug in the bottom of the unit, With a full reservoir, the
compressor will stop working
Continuous drainage
Remove out
1. Unscrew the water stopper and unplug the rubber plug.
2. Connect the drainage pipe to the water container or drainage ditch to outdoor.
‘The length of provided drainage pipe is 24inch (60cm), pipe diameter is 0.55inch( 14mm)OPERATION
PROTECTION FUNCTION OF JHS PORTABLE AIR CONDITIONER
1. Frost Protection Function:
In acold environment, ithe temperature of the EVA pipe sensor's too low, the machine will automatically
enter protection status; ifthe temperature of the EVA pipe sensor rises to a certain temperature
(10°C), itean automatically revert to normal operation.
Overflow Protection Function
When water in the water pan exceeds the warning level, the machine will automatically sound an
alarm and stop working, and the W.F indicator will flash. At this time, you need to drain the water
(details see Drainage Instructions at the end of this chapter).
After the water is emptied, the unit will work normal again.
Protection Function of the Compressor:
To increase the service life of the compressor, ithas a 3-minute delay booting protection function,
after the compressor is turned off
CoN Tae Pa
Before cleaning or maintenance, turn the apy
lance off by pressing the button () onthe control
panel or button ©) onthe emte control WaiforS-19mintes hen unplug rom he alata
outlet
WWI ks
You should ciean the appliance witha slightly damp cloth then dry with a
dry cloth
+ Never wash the alr conditioner with water. It could be dangerous because
of short circult or fire
+ Never use petrol, alcohol or solvents te clean the appliance.
+ Never spray insecticide liquids or similar.CARE AND CLEANING
It the air fiter is clogged with dust, he effectiveness of the air conditioning will be reduced. To keep
your air conditioner working efficiently, you should clean the evaporator iter every two weeks of operation.
+ Press the fastener of airfiter frame from the back
of the unit. Disassemble te filter sereen from the fee PRESSIT
frame { :
Put the ar filter screen into warm water (about
40°C 104°F) with neutral detergent, dy tin the
shade after rinsing clean
+ Ifitis very dirty, use a vacuum cleaner to remove
dust accumulations from the fiter. Immerse in warm
water and rinse a number of times.
+ After washing, leave the fer to dry then re-insert
the fiter
+ Never operate the air conditioner ifthe airfiteris
taken out,
START- END OF SEASON OPERATIONS
END OF SEASON OPERATIONS
@ Remove the cap, run of all water ettinto the basin. When allhe water hasbeen drained, put the
cap backin place.
@® clean the iter and dry thoroughly before puting back
® Remove ihe bateres from the remote
@ Store ho unitina cool, dey room, away fom drwet unligh exireme iarnperatures, and excessive
dust Keep itout ofthe reach of hilaren
‘START OF NEW SEASON CHECKS
@ Make sure the power cable and plug are undamaged
@ Fotiow the instalation instructions precisely, install the unitagain.
@ Pace new batteries int remoteTROUBLESHOOTING
+ Check to make sure that the air conditioner is plugged in securely. If itis not, remove the plug
from the outlet, wait 10 seconds and plug it in again firmly.
+ Check the blown circuit fuse or the tripped main circuit breaker. Ifthey work properly, test the
outlet with another appliance.
‘Troubleshoot your problem by using the chart below. This list includes common occurrences that are
not the result of a defect in factory workmanship or materials.
Ifthe air conditioner still does not work properly, contact JHS customer service center. Customers must
never troubleshoot internal components,
Er Eeneenn Gotan
Unit does not ceminens Drain the water in the bottom tray.
start when REE) B. Reset the temperature,
pressing Heath ara eens C, Recommend to use the unitin at the
ON/OFF button. Pte temperature of 7-35°C (44-95 °F )for
tres = cjg mode.
owt D. Recommend to use the unitin at the
eet cone temperature of 17-35 °C (62-95 °F) for
Pencarian dehumidifying mode.
‘The cooling oftect (ENE EERE ec ea ‘A Pull the curtain,
isnot good. PRUETT 8. Make sure all the windows and doors are
‘There are other sou! closed
Peete i C. Remove the heat sources if possible.
cereals D. Clean the air fiter.
eae E. Make sure the exhaust hose is assembled
Diet Properly.
Big noise or Soe Put the air conditioner on afat and hard
vibration. eects place.
‘The remote
control does not,
work.
A Let the remote control get close tothe air
Conditioning 5M,
B. Make sure that the remote control directly
faces to the direction of the remote control
receiver.
Replace batteries,WARRANTY
JHS PORTABLE AIR CONDITIONER LIMITED WARRANTY
Any repair, replacement, or warranty servi
directed to customer service center,
and all qu
ions about this product should be
‘The warranty commences the day the product is purchased and covers up to a period of 1 year
(12 months) for parts (manufacturing defects only).
JHS will replace the defective product with either a new or remanufactured unit equivalent to
your original purchase during the warranty period.
Exclusions: This warranty does not apply to the below:
+ Ifthe appearance or exterior of the product has been damaged or defaced, altered or mosified in
design or construction,
there is damaged due to power line surge, user damage to the AC power cord or connection to an
improper voltage source.
+ Ifthe damage is due to general misuse, accidents
+ Damages caused by unauthorized repair and using of non-genuine parts,
+ On products that have been purchased as refurbished, like new, second-hand.
+ Unit used in a commercial or rental setting
* Damages caused by improper installations.
We promise to answer your inquiry within 24hours (working day) and provide you an amicably
happy solution.
Email: es@acjhs.com
Website: www.acjhs.com
All the technical and specific parameters, please refer to product nameplate.
Due to continuous improvement, JHS reserves the right to change some design without timely
notice,
Please recycle where facilities exist,
‘mmm Cheok with your local authority or retailer for recycling,
wr Electrical products should be properly disposedYour cold day in the summer
www.acjhs.com
ry
Printed in China