0% found this document useful (0 votes)
3K views34 pages

Jhs

Portable Aircondition Manual - JHS

Uploaded by

MS Deen Jahufar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
3K views34 pages

Jhs

Portable Aircondition Manual - JHS

Uploaded by

MS Deen Jahufar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 34
ORS MANUAL PORTABLE AIR CONDITIONER MODEL NO. A016-10KR/B1 Wi CCS u ee eeu eu seer) rns RCO Ree enue as CCU INTRODUCTION DESCRIPTION OF UNIT AND PARTS. SPECIFICATIONS IMPORTANT SAFETY INSTRUCTIONS Installation and operation Electrical safety... +e ee eee eee a INSTALLATION INSTRUCTIONS Suggested tools for installation Selection of installation location Attaching exhaust hose Window kit installation Connect hose to window kit Check the sealing OPERATION Inserting batteries inthe remote «++ +s eee eee eee eee eee eed Using the remote controls sss see tee eee tee eee eee eee et Control panel and remote keypad JHS Smart (Wi-Fi) Guides -- +--+ see Water drainage. Protection function of JHS portable air conditioner» +++ +++ +++ ee eeee 27 CARE AND CLEANING Cleaning the case Cleaning the filter Start-end of season operations: +++ +++ seer eee eee TROUBLESHOOTING Before you call for service » WARRANTY 4JHS portable air conditioner li dwarranty ++ DESCRIPTION OF UNIT AND PARTS o—_——s @ tance —@ Air-outier crite B Exhaust connector drainage Hole @ controtpanei @ castor ® Power cord @ Airoutiet © FilterFrame Upper @ Filter Frame Lower Air Exhaust Hose Hose Outlet Hose Inlet Remote Control Window Panel ScrewA Ss" 7 Baintions ee re Nh ee 7 SPECIFICATIONS Model A016-10KR/B1 . Fan Speeds 2 Control Type Touch button +Remote | WiFi ves Energy Efficiency Ratio(EER) 2.61ClassA Swing ‘Automatic two-way directional Cooling Capacity 100008TU | Timer yes Noise Level <544BA AirFilter Washable Power Consumption 1280W 11.1A | Drain Options Continuous and manual Estimated CoolingArea__220sq.ft(20m') max | Water-full Indicator Yes Temperature Range 61°F~88°F UnitDimensions 14" Wx 13.3°Dx27.8"H Dehumidifying Capacity 50.7pints/ day Unit Weight 50lbs ‘Amount OF Air Moved (CFM Max.) 205CFM Refrigerant RAIA IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USE Your safety and the safety of others are very important. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. We nave provided many important safety messages in this manual and on the appliance. Always read ‘and follow all safely messages. This is the safety alert symbols. RGN Failed to follow the instructions could result in death or serious injury. PRIME | Files to folow theinstructios couldresultin personal injury or property damage, ( ®@ BE SURENOTTODO { °e BE SURE FOLLOW THE INSTRUCTIONS. IMPORTANT SAFETY INSTRUCTIONS POMS To reduce the risk of explosion, fire, death, electric shock, scalding, or personal injury when using this appliance, please observe the following basic precaution: NEU + Some parts wiht sharp edges may cause _« The portable air conditioneris aheavy injury. So glovesare highly recommended _object, which needs two or more people to for unpacking and installing, liftand install. Failed to do may resultin Injury or other accidents, Oe @e e = 7 + After installation please store the carton, _* This appliance is not intended for use by plasticbag, and otherpacking materials in persons (including children) with reduced a safe place to avoidchildren's contact. _physical, sensory or mental capabilities, Packing materials can become airtight ‘or lack of experience and knowledge unless chambers. they have been given supervision or Instruction concerning use of the appliance by the person responsible for their safety. ea SET.» earronl SG ba “Neverattemptto operate this appliance if + Donot repair or replace any partof the itis damaged, malfunctioning, partially appliance. All repairs and servicing must disassembled orhas missing orbrokenparts, __be performed by qualified service personnel including a damaged cord or plug. Use only authorized JHS factory OEM parts. @ \ IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of explosion, fire, death, electric shock, scalding, or personal injury when using this appliance, please observe the following basic precaution: EU ee + Keep the product away fromfire. Donot —_* Donot use heating equipment near the store or use flammable gases or materials appliance. near the appliance. + Inthe event of a gas leak (propane gas, _« Onlyuse the appliance in an upright position. LP gas,etc.)donot operate this or any other Make sure the angle of inclination 10° appliance. Gpenawindow ordoortoventilate Always place the appliance on a stable, fat, the area immediately, level surface to prevent the air conditioner from overturning, @ s a IMPORTANT SAFETY INSTRUCTIONS INSTALLATION AND OPERATION + Read all instructions before using the appliance and save these instructions. + Power on this appliance in strict accordance with ELECTRICAL SAFETY guide (Page 07.) + Keep the air inlet and outlet free of obstructions. + Do notuse this unit in places exposed to direct sunlight, wind or rain. + Before cleaning or maintenance operations, always unplug the unit from the outl + Ifthe product has been submerged, contact the JHS customer service center for Instructions before resuming use. + Ifthe product makes a strange noise or emits a smell or smoke, pull the power plug out and contact the JHS customer me * Donot place heavy objects (>3KG) on top of the air conditioner. eo IMPORTANT SAFETY INSTRUCTIONS «Donotplace containers with liquids onthe _* Do not use the product in places where it unit could be splashed by water. “Donotuse watertocleantheairconditioner. _ + Do not insert or place fingers or objects into the air discharge area or rear grille of, the unit + California Safe Drinking Water and Toxic Enforcement Act ‘This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after installation. ° IMPORTANT SAFETY INSTRUCTIONS POMS COME Ue heats ELECTRICAL SAFETY (High voltage appliance) eC eee Sree ee ea ee mee ee ey rer Pee Cate ee ety Penne che ot + Do not cover the power cord with a rug or carpeting, Pee cent eeu cn See ern er een Push the power plug all the way into the wall outlet so that itis not ays grip the plug firmly and pull straight out from the outlet when taking er pl ieee oe eee ect Never use the appliance if the outlet is damaged or loose. or IMPORTANT SAFETY INSTRUCTIONS POMS COME Ue heats ELECTRICAL SAFETY (High voltage appliance) + Do not use multiple-outlet power strip or extension cord with this appliance Poeun te ee ot Peete Seen ceter ee on LCDI INTEGRATED CIRCUIT BREAKER GROUNDING METHOD Follow 4 steps on the LCD! plug ‘case, ifthe TEST button does otcause the circuit breaker trip ‘of the RESET button willnot stay ‘engaged, unplug the air conditioner immediately and contact JHS customer service Ensure proper ground center. exists before use Re ee eae any eet ee eet NEW a eile) ML EME Le) IONS SUGGESTED TOOLS FOR INSTALLATION + Screwdrivers (medium size) ‘Tape measure or ruler = Knife or scissors + Saw (In the event that the window kit needs tobe cut down in size because the window is too narrow for direct Installation) SELECTION OF INSTALLATION LOCATION © Place the unit near a window. @ Forest perfomance, allow atleast 20inch (soem) ota spaceonallsdes ofthe untforgoodalrcieulaton, 20ineh au ATTACHING EXHAUST HOSE Install the plastic hose with window bracket adapter and hose connector on both sides. Ensure proper fiton both ends. The supplied exhaust hose can be extended to S8inch max (Stretch both ends ofthe exhaust hose out for 10-15em) i Lock unLock Push the plastic hose into the hose connector on the back of the unit Keep gently and horizontal to avoid getting stuck. Ne EPMO eRe) 1ONS ATTACHING EXHAUST HOSE Note The length ofthe exhaust hose is specially designed for the unit. Do not replace or extend it with another hose as this could cause malfunction. Do not block airflow around the air conditioner. The exhaust hose ‘should be free of any obstructions. Abent hose will block exhaust air and cause the unit to malfunction or shut-off. NOT RECOMMENDED RECOMMENDED WINDOW KIT INSTALLATION Your window slider kithas been designed to ft most standard "Vertical and “Horizontal” window applications, however, it may be necessary for you to improvise / modily some aspect ofthe installation procedures for certain types of window. Minimum and maximum window openings Maximum: 57° (145 em) wii 9 (Sem A m= TALS oT rg EEE tiem inion ap | 18"| 21" 21" 8 8 Z a —— rr 138 ra » c 39-57 vtrte Sar (sen) NOTE: + Adjust to the desired length and use provided metal wing nuts and bolts to secure. + Ifthe window opening is less than 18" the minimum length of the PanelA, cutA with the hole init short fo fit for the window opening. + Never cut out the hole in Panel A Fig.a Sineh-18ineh For a 9°-18" window opening, use panel A (Cut shortif necessary) 8ineh-18inen ea Wie) MN Suid 1ONS WINDOW KIT INSTALLATION Fora 19°-38" window opening, use panelA*B For a39"-57" window opening, use panelA+B+C (Cut short 8 itnecessary) Fig.b Fig.c Fea LO The air exhaust hose must be installed or removed from the portable alr conditioner in accordance with, the way itis being used: 2, Slide ie forlocking 3. Frthe connection fiemly, locking the type screw. ea Wie) MN Suid mie) re Cut the foam seal to the proper length, then attach it to the window frame or panel for sealing, oI Tile) (NEN @ Press and glide the battery cover ‘onthe rearoftheremote, remove the cover, Make sure the polarity is correct @ insert wo new R03 "AAA" 1.5V batteries into the batery compar TEE tment Make sure the polarity Is ea] correct, @® Battery isnotincludedin he pack- age because of transportation safely. NOTE: + Donot mix old and new batteries. Do not mix alkaline, standard (carbon-zinc) or rechargeable batteries. + Ifthe remote contro! is not be used fora certain length of ime, remove the batteries (Batteries may explode orleak). + Ifthe remote control unitis replaced or discarded, the batteries must be removed and disposed of in accordance with current legislation as they are harmful o the environment. INSTALLATION INSTRU 1ONS WEN oe Point the remote control to the air conditioner. The remote control must be no more than 16Ft(5 meters) away from the appliance (without obstacles between the remote control and the appliance). The remote control must be handled with extreme care, Da not drop it or expose it to direct sources of heat, sunlight or water MAX 16 ft er 5 meters Weed OPERATION Qn re ” 6e@e@ eee Power button ‘Swing button @ Up button @ Cooling button @ Mode button @ Timer button ® Down button ® Dehumiditying button @ UP button @ steepmodebutton @ Fan button @® Low speed button @down button GH Swing button © Timer button @ High speed button @ Sieepmodebutton @ LCD display OPERATION nee Se) OPERATION OF FUNCTIONS IS THE SAME WHEN USING REMOTE OR CONTROL PANEL, UNLESS OTHERWISE STATED. 11. When the machine is powered on for the first time, the buzzer will sound "power-on" tone, and then the unit will get into standby status. LCD displays current TEMP, 2.poverbuton ©) Press the key totum on and tur offthe unit. In the case of power on, press the key to turn off the machine inthe case of power off, press the key to turn on the unit 3. Mode Selection Inthe case of power on, >Press the key on the uint panel to choose Q ootina) © ehumisityingy GB (ran) > Pree tekey onthe remote ©) to ston between Cooing-- Dehumisiying Fan mode 4. Upbutton and Down button @Y @® Press the two keys to change the temperature setting value, operation procedure as follow: While setting temperature, press up key or down key to select the required temperature (Non-available in Fan or Dehumidifying mode). Adjustable between 61°F ~ 88°F (16°C~31"C)-Simultaneously press both keys to switch between Celsius (°C ) and Fahrenheit (*F) 5. Fan Speed Selection > Pree ne key onthe remote @) such belweenhigharlow wind speed In Dehumiifying mode, pressing the key is non-effective, and the fan will forcibly choose low wind speed operation. OPERATION OPERATION OF FUNCTIONS IS THE SAME WHEN USING REMOTE OR CONTROL PANEL, UNLESS OTHERWISE STATED. 6. Timer In the case of power on and the unitis turn off, press the key to set time for turning on the unit In the case of power on and the unitis turn on, press the key to set time for turning off the unit Press this ay, when the timing symbol ashes (Hounds, nen ores @) @ toselectne ‘Timing values can be set within 01-24 hours and the timing value is adjusted by one hour. Timing mode can be turned off by set time values 00 or power of. 1-steopmose() In the cooling mode, press the key to enter the sleep mode, the unit wll work on energy-saving and quiet mode. Sleep mode is non-effective in the Dehumidifying or Fan mode. EE ee Using this JHS smart APP you can control the portable AC unit via an iPhone or Android smart phone anywhere, even outside of your home, for example, in office, airport ete, 2 route ‘Supported wi must working with Operating Frequency: 2.4 GHz ‘Standard: IEEE 802.11b/g/n ‘Supported smart phone system: Android 4.1 or later 108 8.0 or later NoTEs: + The Wi-FIAPP is only compatible with smart phones and is not available for laptops or tablets. + APP may not support the latest version of Androidor iOS system because of the test of stability ‘Also may not compatiblo with tampered Android or IOS systom. + Due to different network situation, sometimes, request time-out could happen, itis necessary t0 do network configuration again. + Due to different network situation, the control process may retum time-out(0S-60S) sometimes. In this, situation, there may be some differences between the display of control panel and APP. + Continuous Power-on8of wl be no response because of protection uncon of campressor(3-minute delay). + Allthe illustrations in the manual are for explanation purpose only. The latest APP may be slightly different. The actual shape shall prevail + The mobile APP will continue to be updated with design and content improvements. Check for update at the Play Store or the App Store. ou OPERATION OPERATION GUIDE @ Please ensure your mobile device is connected to WiFi router. Algo, the WIFI outer should already be connected to Internet before doing user registration and network configuration process, © Downtoad and install APP: @rodgistration Sean Rode onthe controlpanelorsearch Open JHS smart APP start Register JHS smart in Reghster OPERATION OPERATION GUIDE: Registration Fill in your mobile number or e-mail address. Click Next and wait a moment (1-10 minutes) gh @ zxcvbnam @ wo space oturn Enter the verification code which is sent from JHS service center via SMS or email then set ‘password by yourself. Click Confirm tofnish registration, ‘six-digit verification code OPERATION OPERATION GUIDE: © Adda now JHS smart unit. Insert power plug to keep unit be standby, “Touch the WiFi button on the unit panel for 5 ‘seconds until LED indicator keep continuous flashing. Back to home page, click Login Fill in your mobile number or e-mail address. Fill in your password and finish login. ot. OPERATION OPERATION GUIDE: © Add anew JHS smart unit Select your corresponding device Power on the device and confirm OPERATION Een ere OPERATION GUIDE ® Adda new JHS smart unit Fill in the WiFi passward and confirm confirm qwertyu asdfghjkt IS zx cvbanm @ Connecting Now OPERATION OPERATION GUIDE: @ Add anew JHS smart unit, Succesfully Added 1 Device(s) share with Family OPERATION OPERATION GUIDE: ‘® Now you can contro! the unit to set your room temperature whether you are driving on road or at the office. ‘Turn your JHS air conditioner on and off Change working modes Set the temperature ma OPERATION Een ere OPERATION GUIDE © Now you' have the control youneed to set your room temperature whether you're driving on the road oratofice. Set fan speeds for comfort and Sel schedules to programme a customized timer energy savings. Function °° Confirm OPERATION EEE Were OPERATION GUIDE ‘© Now you't have the control you need to set your room temperature whether you're driving on the road or at office. sunday Monday Tussday Wednesday Friday OPERATION OPERATION GUIDE © Spociai Functions €€.9._ Share the unt to your famiyo fiend which instaled JHS smart APP, tel ther to fnish login, then come true mut-user conto Moy Device Name noTest Check The Network Check Now Device nfo Create Grou Check for Firmware Update Wee Caen Re JHS portable air conditioner has a self-evaporative system. The condensed water willbe recycled to the working compressor and evaporator, most of the water will be evaporated. This work procedure can not only improve cooling efficiency but also save energy for all customers. Since most of the condensed water will be used to aid the compressor, there is no need of drain hose: Ingeneral using environment, youuse the portable air conditioner for cooling or dehumidifying ina high humidity situation (Relative humidity >25%, like New Orleans, Louisiana, Jacksonville, Florida, Houston), the collected excess. water will need to be drained through a drain plug in the bottom of the unit, With a full reservoir, the compressor will stop working Continuous drainage Remove out 1. Unscrew the water stopper and unplug the rubber plug. 2. Connect the drainage pipe to the water container or drainage ditch to outdoor. ‘The length of provided drainage pipe is 24inch (60cm), pipe diameter is 0.55inch( 14mm) OPERATION PROTECTION FUNCTION OF JHS PORTABLE AIR CONDITIONER 1. Frost Protection Function: In acold environment, ithe temperature of the EVA pipe sensor's too low, the machine will automatically enter protection status; ifthe temperature of the EVA pipe sensor rises to a certain temperature (10°C), itean automatically revert to normal operation. Overflow Protection Function When water in the water pan exceeds the warning level, the machine will automatically sound an alarm and stop working, and the W.F indicator will flash. At this time, you need to drain the water (details see Drainage Instructions at the end of this chapter). After the water is emptied, the unit will work normal again. Protection Function of the Compressor: To increase the service life of the compressor, ithas a 3-minute delay booting protection function, after the compressor is turned off CoN Tae Pa Before cleaning or maintenance, turn the apy lance off by pressing the button () onthe control panel or button ©) onthe emte control WaiforS-19mintes hen unplug rom he alata outlet WWI ks You should ciean the appliance witha slightly damp cloth then dry with a dry cloth + Never wash the alr conditioner with water. It could be dangerous because of short circult or fire + Never use petrol, alcohol or solvents te clean the appliance. + Never spray insecticide liquids or similar. CARE AND CLEANING It the air fiter is clogged with dust, he effectiveness of the air conditioning will be reduced. To keep your air conditioner working efficiently, you should clean the evaporator iter every two weeks of operation. + Press the fastener of airfiter frame from the back of the unit. Disassemble te filter sereen from the fee PRESSIT frame { : Put the ar filter screen into warm water (about 40°C 104°F) with neutral detergent, dy tin the shade after rinsing clean + Ifitis very dirty, use a vacuum cleaner to remove dust accumulations from the fiter. Immerse in warm water and rinse a number of times. + After washing, leave the fer to dry then re-insert the fiter + Never operate the air conditioner ifthe airfiteris taken out, START- END OF SEASON OPERATIONS END OF SEASON OPERATIONS @ Remove the cap, run of all water ettinto the basin. When allhe water hasbeen drained, put the cap backin place. @® clean the iter and dry thoroughly before puting back ® Remove ihe bateres from the remote @ Store ho unitina cool, dey room, away fom drwet unligh exireme iarnperatures, and excessive dust Keep itout ofthe reach of hilaren ‘START OF NEW SEASON CHECKS @ Make sure the power cable and plug are undamaged @ Fotiow the instalation instructions precisely, install the unitagain. @ Pace new batteries int remote TROUBLESHOOTING + Check to make sure that the air conditioner is plugged in securely. If itis not, remove the plug from the outlet, wait 10 seconds and plug it in again firmly. + Check the blown circuit fuse or the tripped main circuit breaker. Ifthey work properly, test the outlet with another appliance. ‘Troubleshoot your problem by using the chart below. This list includes common occurrences that are not the result of a defect in factory workmanship or materials. Ifthe air conditioner still does not work properly, contact JHS customer service center. Customers must never troubleshoot internal components, Er Eeneenn Gotan Unit does not ceminens Drain the water in the bottom tray. start when REE) B. Reset the temperature, pressing Heath ara eens C, Recommend to use the unitin at the ON/OFF button. Pte temperature of 7-35°C (44-95 °F )for tres = cjg mode. owt D. Recommend to use the unitin at the eet cone temperature of 17-35 °C (62-95 °F) for Pencarian dehumidifying mode. ‘The cooling oftect (ENE EERE ec ea ‘A Pull the curtain, isnot good. PRUETT 8. Make sure all the windows and doors are ‘There are other sou! closed Peete i C. Remove the heat sources if possible. cereals D. Clean the air fiter. eae E. Make sure the exhaust hose is assembled Diet Properly. Big noise or Soe Put the air conditioner on afat and hard vibration. eects place. ‘The remote control does not, work. A Let the remote control get close tothe air Conditioning 5M, B. Make sure that the remote control directly faces to the direction of the remote control receiver. Replace batteries, WARRANTY JHS PORTABLE AIR CONDITIONER LIMITED WARRANTY Any repair, replacement, or warranty servi directed to customer service center, and all qu ions about this product should be ‘The warranty commences the day the product is purchased and covers up to a period of 1 year (12 months) for parts (manufacturing defects only). JHS will replace the defective product with either a new or remanufactured unit equivalent to your original purchase during the warranty period. Exclusions: This warranty does not apply to the below: + Ifthe appearance or exterior of the product has been damaged or defaced, altered or mosified in design or construction, there is damaged due to power line surge, user damage to the AC power cord or connection to an improper voltage source. + Ifthe damage is due to general misuse, accidents + Damages caused by unauthorized repair and using of non-genuine parts, + On products that have been purchased as refurbished, like new, second-hand. + Unit used in a commercial or rental setting * Damages caused by improper installations. We promise to answer your inquiry within 24hours (working day) and provide you an amicably happy solution. Email: es@acjhs.com Website: www.acjhs.com All the technical and specific parameters, please refer to product nameplate. Due to continuous improvement, JHS reserves the right to change some design without timely notice, Please recycle where facilities exist, ‘mmm Cheok with your local authority or retailer for recycling, wr Electrical products should be properly disposed Your cold day in the summer www.acjhs.com ry Printed in China

You might also like