Ri ET STE Transforming Railways Indian Railways Centre for Advanced Maintenance Technology Phase I] - Module No. STC-GS- UNIT OF REFRIGERATION “ The unit employed for designating Air Conditioning capacity is a “Ton of Refrigeration”. “ef "st The capacity of a plant is said to be one ton, if it is capable to extracting heat at a rate equivalent to that required to freeze one American ton (2000lbs) of water at 0°C into ice at the same temperature in 24 hrs. OR “ One ton of refrigeration is the heat required to melt 2000 Ibs of ice at 0°C into water at the same temperature in 24 hrs. 1 ton of Refrigeration = 2000 Ibs X 80K.cal/kg. = 907.198 kg x 80 K.cal/kg =72575.84 K.cal/24 Hrs =3023.99K.cal/hrs =3024 K.cal/hr DESIRABLE PROPERTIES OF A REFRIGERANT The refrigerant shall be: Non poisonous Non inflammable. Non-corrosive. Non -irritating. Non — toxicity. No harmful effect on the taste. Cheap & readily available in the market. Eco Friendly. It shall have high latent heat of vaporisation. It shall have low boiling point. It shall have high coefficient of performance. Easy detection of refrigerant leakage. Low freezing point. High specific heat. Low viscosity. High electrical insulation. NAME OF REFRIGERANTS © Ammonia (NH3) : Ice making, cold storage. © Sulphur di oxide(SO2) : Domestic refrigerator. ©) Methyl chloride (CH3CL): Small Domestic refrigerato: © Carbon Dioxide(CO2) : For manufacturing Dry ice, ©) Monoflouro trichloro Methane (F-11) © Dichloro Diflouro Methane (F-12) © Trifluro monochloro Methane (F-13). © Monoflouro dichloro Methane (F-21). o Monochloro Difluro Methane (F-22). o Trifluro chloro Ethane (F-113) © Tetra fluro dicloro Ethane (F-114). o Tetra fluro Ethane (R-134a) o R407c- Substitute for R22 Refrigerant blend containing R32, R125 and R134a (23/25/52% by weight). OZONE DEPLETION POTENTIAL (0.D.P.) * Relative value that indicates the potential of a substance to destroy ozone gas as compared with the potential of chlorofluoro Carbon-11 (CFC-11 or R11) which is assigned a reference value of 1. ¢ Thus, a substance with ODP of 2 is twice as harmful as CFC-11 * R-22, for example, has an ODP of 0.05. GLOBAL WARMING POTENTIAL (G.W.P.) %S Global warming potential (GWP) is a relative measure of how much heat a greenhouse gas traps in the atmosphere. % It compares the amount of heat trapped by a certain mass of the gas in question to the amount of heat trapped by a similar mass of carbon di-oxide. REFRIGERANTS-COMPARISON Property R-407c R-134a R-22 R-12 : Mono- Di- aici Tetrafluoroe si Jorodifluo | chlorodiflu name thane romethane — oromethan: Molecular | 36 102.03 86.868 120.91 mass Boiling pt°C |-46.1 -26.2 -40.8 29.8 Freezing pt °C -142 -256 -252 ou temp | 36.22 102 96 12 Critical 4.62 : . . pressure MPa 590 psia 722 psia | 591 psia GWP/ODP 1600/0 | 1300/0 1700/0.05 | 2400 Cylinder Orange Light sky blue Green White colour DESCRIPTION OF R-407¢ “* Substitute for R22 Refrigerant blend containing R32, R125 and R134a (23/25/52% by weight). “* Temperature glide approx 7K Refrigerant must be charged from liquid phase Physical and thermodynamic properties comparable to R22 Non-flammable and safe to use commercially available miscible with polyol ester oils “* Chemical Name: Difluoromethane, pentafluoroethane, 1,1,1,2- Tetrafluoroethane VAPOUR COMPRESSION CYCLE Main component of Vapour compression cycle are : 1) Compressor ii) Condenser i) Expansion valve iv) Evaporator unit. Schematic Diagram Of Air Conditioning System For Coaches FRESH AIR praisen FILTER a4 [Beek wanna 0 | BS OPENING L = |2@m= oenvonator CUM FILT, “ HEATING &.COOUNG LETS HP CUTOUT O Q HP GAUGE ae urn THERMOSTATS, iON RECEIVER HAND SHUT opel OFF VALVE COMPRESSOR CONDE WER COMPRESSOR pressure being increased due to incréase pressure of vapour temperature of vapour incréase and send to the condenser unit for condensati (Refrigerant in high pressure & in vapour form ) CONDENSER “* It is intended for cooling the hot gas & liquefying it. It may be air cooled or water cooled. or condensate the refrigerant. (Refrigerant in high pressure & in liquid form ) EXPANSION VALVE “* Its function is to control & regulate the rate of flow of liquid refrigerant under high pressure and allow it into the evaporator under low pressure or expended the refrigerant. % ‘s The expansion valve admits more refrigerant when air conditioning load is high & reduces it to minimum when load is low. (After expansion refrigerant in low pressure & in liquid form) EVAPORATOR “* This constitutes the cooling unit, in which the liquid refrigerant under low pressure evaporates and do so, it takes away its quota of latent heat, thereby cooling the medium surrounding the cooling coil. (After evaporation refrigerant in low pressure & in vapour form) High + pressure. Cr or | EXP. VALVE Low U pressure. | Liquid «— Vapour mixture ~~ Super saturated vapour> — — OUTDOORS Fan axle INDOORS ompressor Condenser coils Blower Cooling coils Temperature sensing bulb Indoor air IMPORTANT DIMENSIONS OF VARIOUS LHB < COACHES 1. Composite 1st % AC &AC Two Tier (EOG) LHB_/ Coach fi = SN Description Parameters O1 |No of passenger to sit/sleep AC 1* 10 02 |No of passenger to sit/sleep AC IInd 28 03 |No of lavatories 04 04 | Approx. Linen capacity 2.9 cubic meter 05 | Length over body 23540 mm 06 | Length over CBC 24000 mm 07 |Height of the coach from rail level 4039 mm Maximum width over body 3240 mm Eee Yt 2. AC First Class ~ (EOG) LHB type »> Coach ff SN Description Parameters 1 |No of passenger to sit/Sleep 24 2 |Door aside 02 3 |No of lavatories 03 (02 European and 01 Indian style) 4 |4- Berther 04 Nos. 5 |Cope 04 Nos. 6 |Approx. Linen capacity 1.7 cubic meter 7 |Length over body 23540 mm 8 |Length over CBC 24000 mm 9 |Height of the coach from rail 4039 mm level Maximum width over body 3240 mm (EOG) LHB type Coach 3. AC Three Tier © sata SN Description Parameters 1 |No of passenger to sit/Sleep 72 2 |Door aside 02 3 |No of lavatories 04 4 _|No of passenger per door 18 Nos. 5. |No of passenger per lavatories 18 Nos. 6 |Length over body 23540 mm 7 |Length over CBC 24000 mm 8 | Height of the coach from rail level 4039 mm 9 |Maximum width over body 3240 mm 4. AC Two Tier (EOG). With Wider Cabin Width LHB type Coach f SN Description Parameter 1 | No of passenger to sit/Sleep 52 2 |Door aside 02 3 _|No of lavatories 04 4 No of passenger per door 26 Nos. 5 _|No of passenger per lavatories 13 Nos. 6 |Linen room capacity 3.00 cubic meter 7 |Length over body 23540 mm 8 | Length over CBC 24000 mm. 9 |Height of the coach from rail level 4039 mm Maximum width over body 3240 mm 5. High Capacity Double Decker AC Chair Car (EOG) SN Description Parameter 1 | No of passenger to sit 120 2 |Door aside 02 3 | No of lavatories 04 4 _| No of passenger per door 60 Nos. [5 | No of passenger per lavatories 30 Nos. 7 ‘| Length over body 23540 mm 8 | Length over CBC 24000 mm 9 | Height of the coach from rail level 4366 mm 10 | Maximum width over body 3050 mm. ND ON GENERATION (EOG) SYSTEM * LHB EOG coaches are supplied power by End on generation (EOG) system i.e. by providing power car in front and rear end of a rake. Each power car has two DG sets, out of which one DG set is standby. “* The 750V supply is fed to entire rake through two feeders running on both sides of coaches along the full length of rake. FEEDER- 1 Oma COACHES: COACHES: GENERATOR CAR GENERATOR CAR “* LHB EOG coaches are equipped with 60 kVA step down transformers for stepping down 750 V, 3 ® AC, 4 wire, 50 Hz supply to 415 V, 3 ® AC, 4 wire, 50 Hz supply. Power cars at both ends take entire load of whole rake, which includes: * air conditioning, * light and fan circuit, * emergency battery charger circuit and * pantry equipment. CAMTECH, Gwalior COACH SUPPLY 415V, 38 [ ‘SQ/SOKVA TRANSFORMER 7 TC NOV, 3B 415V, 38 LIGHTING TRANSFORMER LIGHTING LOAD Phase I! - Module No. STC- _LHB TYPE EOG AC COACHES The End on Generation (EOG), Linke Hoffmann Bosch (LHB) variant AC coaches can be broadly classified into AC sleeper coaches and AC chair cars as given on next slide. CH, Gwalior OG COACHES {| CHAIR CAR SECOND AC CHAIR CAR EXECUTIVE AC CHAIR CAR | SLEEPER COACHES 1AC SLEEPER Il AC SLEEPER Ill AC SLEEPER BUFFET COACH POWER CAR Phase I! - Module No. ST HEAD ON GENERATION (HOG) Phase II - Module No. STC-GS-2 HEAD ON GENERATION SYSTEM (HOG) Salient Features » Single phase power supply received from OHE through loco or tapped from OHE in power car through separate pantograph. » Cost effective, reliable and energy efficient. CAMTECH, GWALIOR » Elimination of heavy under slung equipment viz alternator, battery, Inverter etc. in SG coaches and DA sets in EOG power car avoiding noise and smoke pollution. » Inverter (single phase to 3 phase) can be mounted on/ under loco or power car or individual coach. CAiaen me men Phase Il - Module No. STC-GS-1 Ratings of Important Electrical Equipment S : ‘ Qty/ N Equipment Rating Coach 1 Step down 3 @, 750 V/ 415V AC, 1 Transformer 60kVA > | Batt 70 Ah, 12 V Monoblock, 9 Mono aueery Lead Tin/ VRLA blocks 3 [Sealed 30,415 VAC 4 Compressor 4 |Condenser Motor |1 HP, 3 8, 415 V AC 4 5 |Blower Motor 1.5 HP, 3 @, 415 VAC 2 Qty/ SN Equipment Rating Coach 6 |Condenser Coil Fin on tube type 4 7 |Cooling Coil Fin on tube type 8 |Heater Unit 3 0, 415 VAC, 6kW 2 9 |Monoblock Pump {3 @, 415 V AC, 0.5 HP 2 Input =: 230V+5%, 10 10 JE Chi 1 eae nee Output: 110V DC Input: 415V, 3 @, AC 11 |Regulated Charger npn 1 Output: 110 V DC HOG SCHEME WITH 2 X 450 KVA BILK CONVERTER (PHASE D2) ‘TWO FEEDERS ( 750 V ,3 PHASE/1 PHASE) SLR.CUM CAR AC COACH NON-ACCOACH sLECUMFOWER CAR ( | | } | vine } ELECTRICAL LOCO WAP-S i * OOO OO OSCE Ames - Module No. STC-GS-1 CEPT OF HOG (HEAD G » The name HOG (Head ON Generation), itself implies that the electrical energy required for non-traction use is derived from the driving head (electric traction loco), which draws the electric supply from the Over-Head traction wires for traction purpose. » This high tension over-head traction supply of 25000 VAC (single phase) is tapped and fed to the converters which steps down and converts the electric supply to 750 V (3 Ph) AC supply, which is then fed to all the coaches in the entire train for non traction use. - OBJECTIVES mmeoreythin “* Switching over from ‘End ON Generation’ (EOG) system to ‘Head ON Generation’ (HOG) system of power supply, in running of the trains, is one of the steps taken by the railway ministry, as a contribution towards the objectives of green initiatives of the Indian Government. “ % "s Introduction of HOG system will reduce working of diesel generating sets required in EOG system. The objectives and the benefits of the HOG systems is enumerated here. OBJECTIVES OF HOG SYSTEM *& Eliminating Air and noise pollution caused due to working of Diesel Engines. Conservation of Petroleum resources (HSD oil), thus subsequently reducing effective cost of operation. Hoc SYSTEM COMPONENTS AND LOCATION PASSENGER 7 POWER COACH Pt CAR Phase II - Module No. STC-GS-2 INTERCONNECTION BETWEEN Loco & POWER CAR POWER CAR LOCOMOTIVE ive covetnoy TOWER CAR . A CONV EE CONTROL PANEL luc courts }CAB-1 CAB2 luc COUPLER-01 hve covrtexo1 B | [eonra \ REE] “ 0 IVF Coupler-01: CONV-A R, YB, E, Cl IVF Coupler-02; CONV-B R, Y.B, E, Cl UIC Coupler- 01& 02: * Control signals to and from the Converter and Loco to the Power Car. + Redundant system. If one UIC fails the other will ensure the Converter and train is healthy. ~ Modul Sts Indian Railways | Centre for Advanced Maintenance Technology ‘ ‘Phase Il — Module no, STC-GS-2 EXT. SUPPLY SOCKET IV COUPLER Electrical Features of LHB EOG AC Coaches | o IGBT based battery charger. o Micro-controller based Roof Mounted Package Unit (RMPU) for Air Conditioning. © Microprocessor based pump controller unit. o Integrated, modular single Switch Board Cabinet with controls of AC, lighting & pantry etc Provision of Dry type Transformer without. encapsulation Modular and elegant interior light fittings and reading lights. Integrated modular pantry unit Provision of electron beam irradiated cables. Provision of Measuring and Monitoring relays in Feeder circuit. Online insulation monitoring. Uniformity of illumination. Wheel set earthing equipment for high life of axle bearings. Provision of earthing and disconnecting device. Cable protection system with IP-67 protection and UL-94 VO fire retardancy. Screw less, modular elegant switches. Provision of Emergency Battery charger Switch-Board Cabinet- S1 A modular, integrated single cabinet designated switch board cabinet comprising all necessary equipments for control and protection of following coach systems: ** Microprocessor based Heating, Ventilation & Air conditioning *% Lighting Pantry Anti skid protection Public Address system Sanitary system (except W.C. control) Regulated IGBT based Battery charger Disconnecting and Earthing device. On-line insulation monitoring relays MCBS_— Anti-skid device_ De-de converters — Space for the main contactors _ Battery charger— Disconnecting and — earthing device Switch-Board Cabinet- $1 Pump) Sanitary Equipment Anti Skid Devices Wago Connectors for Cable _ Terminators Microprocessor ™ Controller for AC Package Unit (Rotating Frame) Space for the Disconnecting __. And Earthing Device Inside View of Switch-Board Cabinet Cable alleys f Insulation Monitoring device _ a 1 kVA transformer— LV fuses (transformer)— Switchboard View with Top Right Door Open MCB’S FORTHE AC PACKAGE ~~ VOLTMETER ( 750 VOLTS ) — AMMETER SELECTOR SWITCH PA VOLUME CONTROL Indication and Controls on Left Side Door Additions / Modifications done later on... ¢ Provision of individual leaf doors with push type locking arrangement. * Provision of stainless steel doors for the bottom panel doors, * Left door has been made in two parts. ¢ Feeder contactors control from 110 volts DC have been changed to 415 volts AC like the conventional AC coaches. Modified Doors Arrangement II - Module No. . Disconnecting and Earthing Device Disconnecting and Earthing Device is an OFF load device rated for 125 amps at 750 volts fed from Generator Car through ZS couplings. This is provided in Switch Board Cabinet. Tt has two positions ON & EARTH. It disconnects feed at 750V and earths the coach in case of emergency like contactor jamming or maintenance of coach even during running of coaches. CAMTECH, Gwalior ON position OFF position Hand Lever Disconnecting and Earthing Device Phase II - Module No. STC-GS-2 Microprocessor Controlled AC Package Unit (RMPU type) * Microprocessor controlled, two AC package units are provided in each coach at the ends. * Both package units are controlled by a microcomputer based controller, mounted in switch board cabinet S1 and fed from battery net. * These units work in fully automatic mode. Depending on ambient temperature, available modes of heating, ventilating, cooling and dehumidifying are selected and controlled. Technical Data (Output data per unit) Cooling capacity Heating capacity Compressor motors Nominal power Supply Voltage Fan motor axial (for condenser) Fan motor radial (for evaporator) 7.0TR 6.0kW 49kW 16.5 kVA 415 V,3 @, AC, 50 Hz 1HP, 415V, 3 @, AC, 50 Hz 1.SHP, 415V, 3 @, AC, 50 Hz Air volume Fresh air supply (m*/hr) Max. power input, cooling (kW) Max. power input, heating (kW) Max. power input, dehumidifying (kW) Refrigerant Weight (kg) Dimensions (mm) $20 13.25 6.0 11.0 Approximate R-22 630 Approximate 2200 x 2000 x 500 Quantity of refrigerant RMPU Make Fedders Lloyd/ LELL Amit SIDWAL/ INTEC Approx. Qty. per unit 4.2 kg per unit 3.2 kg per unit 2.85 kg per unit Condenser Fans Air Intake For Condenser Fans Roof Mounted AC Package Unit . . Each air conditioning package unit has two separate cooling circuits consisting of following components: Refrigeration compressors Condensers with Copper pipes and Aluminum fins Condenser fan Evaporators with Copper pipes and Aluminum fins Heating assembly - Two (nos.) - Two (nos.) - Two (nos.) - Two (nos.) - One (nos.) Twin-sucking radial fans for supply air (driven by single motor) - One (nos.) Maintenance covers - Six (nos.) Air inlets for circulating air - Two (nos.) Air inlets for fresh air - Two(nos.) Mixed air filters & Fresh air filter - for two (nos.) of each Air outlet for supply air - One (no.) Control and safety devices - HP-2,LP-2,OHP-1 ESTI-1,control Pressure-2. Condenser Air Intake Grill Flexible Conduit For Electrical Connection To Unit Electrical Junction Box (One On Each Side) Fresh Air Duct (Canvas/ Latest As Per Rdso Spec.) Mounting Bracket Return Air Duct View of RMPU with Side Cover Open | Earthing Cable. Evaporator Motor Heater Area Evaporator Motor Unit in RMPU Compressors Copper Heating Refrigerant Unit Piping Evaporator Motor Unit Compressors Units in RMPU RMPU Heating Unit PRESSURE TRANSDUCERS ECH, Gwalior Fresh Air Damper Servo Motor Junction Box Servomotor Controlled Fresh Air Dampers in RMPU Phase I! - Module Ne Temperature Air Condition — Fault Selector Switch Selector Off-on Switch Indication For Lp/Hp Switch Lamp Measurement Control Panel Pha: II - Module No. CH, Gwalior Micro Controller Cage Clamp Connector Microprocessor Based Controller for RMPU Phase I! - Module Ne Thermostat Heating Elements With Fuseable Cartridge Heating Unit Elements in RMPU General Data of RMPU components Compressor 1. Hermetically sealed scroll compressor u. Each with min 3.5 TR capacity at 60 Deg C condensing and 5 Deg C evaporating temperature. i. Total rating of AC package unit not less than 7 Tr. b) Heat Exchangers i. il. Air cooled Copper tubes with aluminum fins c) Filters i. Each unit has 2 fresh air and 2 mixed air filters Material is progressively structured, non — woven break resistant, thermally bonded fire retardant synthetic material. d) Humidity Control 1. Restricts the humidity level to 60 % ii. Monitored by Hygrostat iil. Desired temperature is achieved by switching on heaters as per logic, such that the combined power consumption does not exceed the permissible power under cooling capacity. 'e) Sensors i. ii. NTC type sensors Temperature settings are achieved by rotary switch provided on the Switch Board Cabinet. Temperature Cooling Heating 20.0 Deg C 17.0 Deg C 20.5 Deg C 17.5 Deg C 21.2 Deg C 18.2 Deg C 21.9 Deg C 18.9 Deg C | Position of switch 22.6DegC | 19.6 Deg C 24.3 Deg C 20.3 Deg C 25.0 Deg C 21.0 Deg C ala} ufa[wlro)— g) Refrigerating Piping 1. As per drawing. h) Protections i. LP, HP cut outs have been provided in the refrigerant circuit ii. Overheat protector has been provided in the heater circuit i ESTI protection has been provided in the heater circuit to operate at 130°C in case of failure of overheat protector for ultimate disconnection of power supply to heater. Individual electrical protection has been provided by MCB’s In-built overheat protection has also been provided in the motors windings, which are interlocked with microprocessor. Ratings of Important Electrical Equipment S : ‘ Qty/ N Equipment Rating Coach 1 Step down 3 @, 750 V/ 415V AC, 1 Transformer 60kVA > | Batt 70 Ah, 12 V Monoblock, 9 Mono aueery Lead Tin/ VRLA blocks 3 [Sealed 30,415 VAC 4 Compressor 4 |Condenser Motor |1 HP, 3 8, 415 V AC 4 5 |Blower Motor 1.5 HP, 3 @, 415 VAC 2 Qty/ SN Equipment Rating Coach 6 |Condenser Coil Fin on tube type 4 7 |Cooling Coil Fin on tube type 8 |Heater Unit 3 0, 415 VAC, 6kW 2 9 |Monoblock Pump {3 @, 415 V AC, 0.5 HP 2 Input =: 230V+5%, 10 10 JE Chi 1 eae nee Output: 110V DC Input: 415V, 3 @, AC 11 |Regulated Charger npn 1 Output: 110 V DC [arn Train LIGHTING EQUIPMENT * 110V (9 modules of 12 volt, 70Ah) VRLA battery * Battery fuse box ¢ Battery charger + Internal light fittings IOV (9 modules of 12 volt, 70 Ah) VRLA Battery fe Ss Coaches are provided with 9 modules of 12 volt 70Ah, VRLA battery in series in one battery box. “ The auxiliary power required for charging is supplied by a battery charger at constant voltage based as required by the battery. ** Current limit for battery charging is 20 Amp. on board charging at constant voltage with the voltage setting at 122.0 + 1.0 volt. Battery Module Salient Features Capacity : 12 V 70 Ah (at 27° C) battery module Container : PP-CP (Polypropylene Co-Polymers) V2 grade/ ABS FR V2 grade Rate of Discharge : 10 hr Overall length : 352 mm Maximum height : 178 mm Dimensions width : 170 mm Maximum weight per module : 26.5 Kg 9 Modules Of 12 Volts Each Total Weight 235 Kg Battery Box Clamping Arrgt. —— End Cell —~7] Connector Battery Fuse Box Battery fuse box is provided in under frame supported on brackets by fixing bolts. This box is properly earthed by earth cable. It is totally covered and locked by hinged bolts. - Shunt HRC Fuses Clamp Cage Connectors Battery Fuse Box (-ve) Mounting Cable Entry Holes Hall Effect Transducer Box Cover Note :- Hall Effect Transducer has been eliminated and has been integrated in the regulated battery charger itself IGBT Based Battery Charger > It is a 19” switch cabinet rack, force cooled mounted inside switch board cabinet, with current and temperature sensors. » Tt converts transformer’s secondary voltage 30, 415V, AC into 110V, DC for charging battery and feeding direct voltage loads. >It has a power capacity of 6.5 Kw. It has following features: ve Phase angle control for CVCI charging Low voltage and current ripples as low as 2% and THD less than 3%. Charging dependent on electrolyte temperature which is monitored by temperature sensor provided inside battery box. Soft start and quick shutdown Modifications / changes The Hall Effect transducer provided in Battery fuse box (to control the charging current of the battery) in the earlier OEM design coaches has been shifted to the battery charger itself. The wiring for the same has also been removed Light Fittings = Light fittings are provided with injection moulded and extruded diffuser for defused lighting with uniformity of illumination and lumen as per UIC = These fittings are screw less and press fit type. " Vestibule, toilet, pantry and emergency lighting works at 110V AC /DC with inverter and poly carbonate diffusers ECH, Gwalior eading lights are halogen type. Complete lighting is with high frequency ballast (58 kHz) for flicker free comfort lighting. Phase IT - Module Ratings of different lightings Fluorescent tubes (watt) : 18 Halogen lamp (watt) : 10 (reading lights) Incandescent Lamp FITTING AC Duct Panelling Compartment Light Inside View Phase IT - Mod: CAMTECH, Gwalior Inverter/ Ballast Mounted Along The Fitting Fluorescent Light Fitting Inverter Phase I! - Module No. STC-GS-2 Injection Moulded End Piece Polycarbonate Extruded Diffuser Vestibule Light Fitting Doorway Light Fitting Pha: CAMTECH, Gwalior Focus Halogen —Off-on Switch Luggage Adjustment Lamp Rack Screw Reading Light Fitting Phase I] - Module Reading Light Inverter / Ballast PI Mod Thank You

You might also like