ET STE Transforming Railways
Indian Railways
Centre for Advanced Maintenance Technology
Phase I] - Module No. STC-GS-UNIT OF REFRIGERATION
“ The unit employed for designating Air
Conditioning capacity is a “Ton of Refrigeration”.
“ef
"st
The capacity of a plant is said to be one ton, if it is
capable to extracting heat at a rate equivalent to
that required to freeze one American ton (2000lbs)
of water at 0°C into ice at the same temperature in
24 hrs.OR
“ One ton of refrigeration is the heat required to melt
2000 Ibs of ice at 0°C into water at the same
temperature in 24 hrs.
1 ton of Refrigeration = 2000 Ibs X 80K.cal/kg.
= 907.198 kg x 80 K.cal/kg
=72575.84 K.cal/24 Hrs
=3023.99K.cal/hrs
=3024 K.cal/hrDESIRABLE PROPERTIES OF A
REFRIGERANT
The refrigerant shall be:
Non poisonous
Non inflammable.
Non-corrosive.
Non -irritating.
Non — toxicity.
No harmful effect on the taste.
Cheap & readily available in the market.
Eco Friendly.It shall have high latent heat of vaporisation.
It shall have low boiling point.
It shall have high coefficient of performance.
Easy detection of refrigerant leakage.
Low freezing point.
High specific heat.
Low viscosity.
High electrical insulation.NAME OF REFRIGERANTS
© Ammonia (NH3) : Ice making, cold storage.
© Sulphur di oxide(SO2) : Domestic refrigerator.
©) Methyl chloride (CH3CL): Small Domestic refrigerato:
© Carbon Dioxide(CO2) : For manufacturing Dry ice,
©) Monoflouro trichloro Methane (F-11)
© Dichloro Diflouro Methane (F-12)
© Trifluro monochloro Methane (F-13).© Monoflouro dichloro Methane (F-21).
o Monochloro Difluro Methane (F-22).
o Trifluro chloro Ethane (F-113)
© Tetra fluro dicloro Ethane (F-114).
o Tetra fluro Ethane (R-134a)
o R407c- Substitute for R22 Refrigerant blend
containing R32, R125 and R134a
(23/25/52% by weight).OZONE DEPLETION POTENTIAL
(0.D.P.)
* Relative value that indicates the potential of a
substance to destroy ozone gas as compared with
the potential of chlorofluoro Carbon-11 (CFC-11 or
R11) which is assigned a reference value of 1.
¢ Thus, a substance with ODP of 2 is twice as
harmful as CFC-11
* R-22, for example, has an ODP of 0.05.GLOBAL WARMING POTENTIAL (G.W.P.)
%S Global warming potential (GWP) is a relative
measure of how much heat a greenhouse gas traps
in the atmosphere.
% It compares the amount of heat trapped by a certain
mass of the gas in question to the amount of heat
trapped by a similar mass of carbon di-oxide.REFRIGERANTS-COMPARISON
Property R-407c R-134a R-22 R-12
: Mono- Di-
aici Tetrafluoroe si Jorodifluo | chlorodiflu
name thane
romethane — oromethan:
Molecular | 36 102.03 86.868 120.91
mass
Boiling pt°C |-46.1 -26.2 -40.8 29.8
Freezing pt °C -142 -256 -252
ou temp | 36.22 102 96 12Critical 4.62 : . .
pressure MPa 590 psia 722 psia | 591 psia
GWP/ODP 1600/0 | 1300/0 1700/0.05 | 2400
Cylinder Orange Light sky blue Green White
colourDESCRIPTION OF R-407¢
“* Substitute for R22 Refrigerant blend containing
R32, R125 and R134a (23/25/52% by weight).
“* Temperature glide approx 7K Refrigerant must
be charged from liquid phase Physical and
thermodynamic properties comparable to R22
Non-flammable and safe to use commercially
available miscible with polyol ester oils
“* Chemical Name: Difluoromethane,
pentafluoroethane, 1,1,1,2- TetrafluoroethaneVAPOUR COMPRESSION CYCLE
Main component of Vapour compression cycle are :
1) Compressor
ii) Condenser
i) Expansion valve
iv) Evaporator unit.Schematic Diagram Of Air Conditioning
System For Coaches
FRESH AIR
praisen FILTER
a4 [Beek wanna 0
| BS OPENING
L = |2@m= oenvonator
CUM FILT,
“ HEATING &.COOUNG LETS
HP CUTOUT O Q HP GAUGE ae urn THERMOSTATS, iON
RECEIVER
HAND SHUT
opel OFF VALVE
COMPRESSOR CONDE WERCOMPRESSOR
pressure being increased due to incréase pressure of
vapour temperature of vapour incréase and send to
the condenser unit for condensati
(Refrigerant in high pressure & in vapour form )CONDENSER
“* It is intended for cooling the hot gas & liquefying
it. It may be air cooled or water cooled. or
condensate the refrigerant.
(Refrigerant in high pressure & in liquid form )EXPANSION VALVE
“* Its function is to control & regulate the rate of flow
of liquid refrigerant under high pressure and allow
it into the evaporator under low pressure or
expended the refrigerant.
%
‘s
The expansion valve admits more refrigerant when
air conditioning load is high & reduces it to
minimum when load is low.
(After expansion refrigerant in low pressure &
in liquid form)EVAPORATOR
“* This constitutes the cooling unit, in which the
liquid refrigerant under low pressure evaporates
and do so, it takes away its quota of latent heat,
thereby cooling the medium surrounding the
cooling coil.
(After evaporation refrigerant in low pressure
& in vapour form)High
+ pressure.
Cr or |
EXP.
VALVE Low
U pressure. |
Liquid «— Vapour mixture ~~ Super saturated vapour>
— —OUTDOORS
Fan axle
INDOORS
ompressor Condenser coils
Blower
Cooling coils Temperature
sensing bulb Indoor airIMPORTANT DIMENSIONS OF VARIOUS LHB <
COACHES
1. Composite 1st %
AC &AC Two
Tier (EOG) LHB_/
Coach fi
=
SN Description Parameters
O1 |No of passenger to sit/sleep AC 1* 10
02 |No of passenger to sit/sleep AC IInd 28
03 |No of lavatories 04
04 | Approx. Linen capacity 2.9 cubic meter
05 | Length over body 23540 mm
06 | Length over CBC 24000 mm
07 |Height of the coach from rail level 4039 mm
Maximum width over body 3240 mmEee Yt
2. AC First Class ~
(EOG) LHB type »>
Coach ff
SN Description Parameters
1 |No of passenger to sit/Sleep 24
2 |Door aside 02
3 |No of lavatories 03 (02 European and 01 Indian style)
4 |4- Berther 04 Nos.
5 |Cope 04 Nos.
6 |Approx. Linen capacity 1.7 cubic meter
7 |Length over body 23540 mm
8 |Length over CBC 24000 mm
9 |Height of the coach from rail 4039 mm
level
Maximum width over body 3240 mm(EOG) LHB
type Coach
3. AC Three Tier ©
sata
SN Description Parameters
1 |No of passenger to sit/Sleep 72
2 |Door aside 02
3 |No of lavatories 04
4 _|No of passenger per door 18 Nos.
5. |No of passenger per lavatories 18 Nos.
6 |Length over body 23540 mm
7 |Length over CBC 24000 mm
8 | Height of the coach from rail level 4039 mm
9 |Maximum width over body 3240 mm4. AC Two Tier (EOG).
With Wider Cabin
Width LHB type
Coach f
SN Description Parameter
1 | No of passenger to sit/Sleep 52
2 |Door aside 02
3 _|No of lavatories 04
4 No of passenger per door 26 Nos.
5 _|No of passenger per lavatories 13 Nos.
6 |Linen room capacity 3.00 cubic meter
7 |Length over body 23540 mm
8 | Length over CBC 24000 mm.
9 |Height of the coach from rail level 4039 mm
Maximum width over body 3240 mm5. High Capacity
Double Decker AC
Chair Car (EOG)
SN Description Parameter
1 | No of passenger to sit 120
2 |Door aside 02
3 | No of lavatories 04
4 _| No of passenger per door 60 Nos.
[5 | No of passenger per lavatories 30 Nos.
7 ‘| Length over body 23540 mm
8 | Length over CBC 24000 mm
9 | Height of the coach from rail level 4366 mm
10 | Maximum width over body 3050 mm.ND ON GENERATION (EOG) SYSTEM
* LHB EOG coaches are supplied power by End on
generation (EOG) system i.e. by providing power
car in front and rear end of a rake. Each power car
has two DG sets, out of which one DG set is
standby.
“* The 750V supply is fed to entire rake through two
feeders running on both sides of coaches along the
full length of rake.FEEDER- 1
Oma
COACHES:
COACHES:
GENERATOR
CAR
GENERATOR
CAR
“* LHB EOG coaches are equipped with 60 kVA step
down transformers for stepping down 750 V, 3 ®
AC, 4 wire, 50 Hz supply to 415 V, 3 ® AC, 4 wire,
50 Hz supply.Power cars at both ends take entire load of whole
rake, which includes:
* air conditioning,
* light and fan circuit,
* emergency battery charger circuit and
* pantry equipment.CAMTECH, Gwalior
COACH SUPPLY
415V, 38 [
‘SQ/SOKVA TRANSFORMER 7
TC
NOV, 3B
415V, 38
LIGHTING TRANSFORMER
LIGHTING LOAD
Phase I! - Module No. STC-_LHB TYPE EOG AC COACHES
The End on Generation (EOG), Linke Hoffmann
Bosch (LHB) variant AC coaches can be broadly
classified into AC sleeper coaches and AC chair cars
as given on next slide.CH, Gwalior
OG COACHES
{| CHAIR CAR
SECOND AC CHAIR CAR
EXECUTIVE AC CHAIR CAR
| SLEEPER COACHES
1AC SLEEPER
Il AC SLEEPER
Ill AC SLEEPER
BUFFET COACH
POWER CAR
Phase I! - Module No. STHEAD ON GENERATION
(HOG)
Phase II - Module No. STC-GS-2HEAD ON GENERATION SYSTEM
(HOG)
Salient Features
» Single phase power supply received from OHE
through loco or tapped from OHE in power
car through separate pantograph.
» Cost effective, reliable and energy efficient.
CAMTECH, GWALIOR» Elimination of heavy under slung equipment viz
alternator, battery, Inverter etc. in SG coaches
and DA sets in EOG power car avoiding noise
and smoke pollution.
» Inverter (single phase to 3 phase) can be
mounted on/ under loco or power car or
individual coach.
CAiaen me men Phase Il - Module No. STC-GS-1Ratings of Important Electrical Equipment
S : ‘ Qty/
N Equipment Rating Coach
1 Step down 3 @, 750 V/ 415V AC, 1
Transformer 60kVA
> | Batt 70 Ah, 12 V Monoblock, 9 Mono
aueery Lead Tin/ VRLA blocks
3 [Sealed 30,415 VAC 4
Compressor
4 |Condenser Motor |1 HP, 3 8, 415 V AC 4
5 |Blower Motor 1.5 HP, 3 @, 415 VAC 2Qty/
SN Equipment Rating Coach
6 |Condenser Coil Fin on tube type 4
7 |Cooling Coil Fin on tube type
8 |Heater Unit 3 0, 415 VAC, 6kW 2
9 |Monoblock Pump {3 @, 415 V AC, 0.5 HP 2
Input =: 230V+5%, 10
10 JE Chi 1
eae nee Output: 110V DC
Input: 415V, 3 @, AC
11 |Regulated Charger npn 1
Output: 110 V DCHOG SCHEME WITH 2 X 450 KVA BILK
CONVERTER (PHASE D2)
‘TWO FEEDERS ( 750 V ,3 PHASE/1 PHASE)
SLR.CUM CAR AC COACH NON-ACCOACH sLECUMFOWER CAR
( | | } |
vine
}
ELECTRICAL LOCO
WAP-S
i *
OOO OO
OSCE Ames - Module No. STC-GS-1CEPT OF HOG (HEAD G
» The name HOG (Head ON Generation), itself implies that
the electrical energy required for non-traction use is
derived from the driving head (electric traction loco),
which draws the electric supply from the Over-Head
traction wires for traction purpose.
» This high tension over-head traction supply of 25000 VAC
(single phase) is tapped and fed to the converters which
steps down and converts the electric supply to 750 V (3 Ph)
AC supply, which is then fed to all the coaches in the entire
train for non traction use.- OBJECTIVES mmeoreythin
“* Switching over from ‘End ON Generation’ (EOG)
system to ‘Head ON Generation’ (HOG) system of power
supply, in running of the trains, is one of the steps taken
by the railway ministry, as a contribution towards the
objectives of green initiatives of the Indian Government.
“
%
"s
Introduction of HOG system will reduce working of
diesel generating sets required in EOG system. The
objectives and the benefits of the HOG systems is
enumerated here.OBJECTIVES OF HOG SYSTEM
*& Eliminating Air and noise pollution
caused due to working of Diesel Engines.
Conservation of Petroleum resources
(HSD oil), thus subsequently reducing
effective cost of operation.Hoc SYSTEM COMPONENTS AND LOCATION
PASSENGER 7 POWER
COACH
Pt CAR
Phase II - Module No. STC-GS-2INTERCONNECTION BETWEEN Loco &
POWER CAR
POWER CAR
LOCOMOTIVE
ive covetnoy TOWER CAR .
A CONV EE CONTROL PANEL
luc courts
}CAB-1 CAB2 luc COUPLER-01
hve covrtexo1
B | [eonra \ REE] “
0
IVF Coupler-01: CONV-A
R, YB, E, Cl
IVF Coupler-02; CONV-B
R, Y.B, E, Cl
UIC Coupler- 01& 02:
* Control signals to and from the Converter and Loco to the
Power Car.
+ Redundant system. If one UIC fails the other will ensure
the Converter and train is healthy.
~ ModulSts
Indian Railways |
Centre for Advanced Maintenance Technology ‘
‘Phase Il — Module no, STC-GS-2EXT. SUPPLY
SOCKET IV COUPLERElectrical Features of LHB EOG AC Coaches |
o IGBT based battery charger.
o Micro-controller based Roof Mounted Package Unit
(RMPU) for Air Conditioning.
© Microprocessor based pump controller unit.
o Integrated, modular single Switch Board Cabinet
with controls of AC, lighting & pantry etcProvision of Dry type Transformer without.
encapsulation
Modular and elegant interior light fittings and
reading lights.
Integrated modular pantry unit
Provision of electron beam irradiated cables.
Provision of Measuring and Monitoring relays in
Feeder circuit.
Online insulation monitoring.Uniformity of illumination.
Wheel set earthing equipment for high life of axle
bearings.
Provision of earthing and disconnecting device.
Cable protection system with IP-67 protection and
UL-94 VO fire retardancy.
Screw less, modular elegant switches.
Provision of Emergency Battery chargerSwitch-Board Cabinet- S1
A modular, integrated single cabinet designated switch
board cabinet comprising all necessary equipments for
control and protection of following coach systems:
** Microprocessor based Heating, Ventilation & Air
conditioning
*% LightingPantry
Anti skid protection
Public Address system
Sanitary system (except W.C. control)
Regulated IGBT based Battery charger
Disconnecting and Earthing device.
On-line insulation monitoring relaysMCBS_—
Anti-skid device_
De-de converters —
Space for the main contactors _
Battery charger—
Disconnecting and —
earthing device
Switch-Board Cabinet- $1Pump) Sanitary Equipment
Anti Skid Devices
Wago Connectors for Cable _
Terminators
Microprocessor ™
Controller for AC Package
Unit (Rotating Frame)
Space for the Disconnecting __.
And Earthing Device
Inside View of Switch-Board CabinetCable alleys f
Insulation Monitoring device _ a
1 kVA transformer—
LV fuses (transformer)—
Switchboard View with Top Right Door OpenMCB’S FORTHE AC PACKAGE ~~
VOLTMETER ( 750 VOLTS ) —
AMMETER SELECTOR
SWITCH
PA VOLUME CONTROL
Indication and Controls on Left Side DoorAdditions / Modifications done later on...
¢ Provision of individual leaf doors with push type
locking arrangement.
* Provision of stainless steel doors for the bottom
panel doors,
* Left door has been made in two parts.
¢ Feeder contactors control from 110 volts DC have
been changed to 415 volts AC like the conventional
AC coaches.Modified Doors Arrangement
II - Module No..
Disconnecting and Earthing Device
Disconnecting and Earthing Device is an OFF load
device rated for 125 amps at 750 volts fed from
Generator Car through ZS couplings.
This is provided in Switch Board Cabinet.
Tt has two positions ON & EARTH.
It disconnects feed at 750V and earths the coach in
case of emergency like contactor jamming or
maintenance of coach even during running of
coaches.CAMTECH, Gwalior
ON
position
OFF
position
Hand
Lever
Disconnecting and Earthing Device
Phase II - Module No. STC-GS-2Microprocessor Controlled AC Package Unit
(RMPU type)
* Microprocessor controlled, two AC package units are
provided in each coach at the ends.
* Both package units are controlled by a microcomputer
based controller, mounted in switch board cabinet S1 and
fed from battery net.
* These units work in fully automatic mode. Depending on
ambient temperature, available modes of heating,
ventilating, cooling and dehumidifying are selected and
controlled.Technical Data (Output data per unit)
Cooling capacity
Heating capacity
Compressor motors
Nominal power
Supply Voltage
Fan motor axial (for condenser)
Fan motor radial (for evaporator)
7.0TR
6.0kW
49kW
16.5 kVA
415 V,3 @, AC, 50 Hz
1HP, 415V, 3 @, AC, 50 Hz
1.SHP, 415V, 3 @, AC, 50 HzAir volume
Fresh air supply (m*/hr)
Max. power input, cooling (kW)
Max. power input, heating (kW)
Max. power input, dehumidifying (kW)
Refrigerant
Weight (kg)
Dimensions (mm)
$20
13.25
6.0
11.0 Approximate
R-22
630 Approximate
2200 x 2000 x 500Quantity of refrigerant
RMPU Make
Fedders Lloyd/ LELL
Amit
SIDWAL/ INTEC
Approx. Qty. per unit
4.2 kg per unit
3.2 kg per unit
2.85 kg per unitCondenser Fans Air Intake For Condenser Fans
Roof Mounted AC Package Unit.
.
Each air conditioning package unit has two separate
cooling circuits consisting of following components:
Refrigeration compressors
Condensers with Copper pipes and
Aluminum fins
Condenser fan
Evaporators with Copper pipes and
Aluminum fins
Heating assembly
- Two (nos.)
- Two (nos.)
- Two (nos.)
- Two (nos.)
- One (nos.)Twin-sucking radial fans for supply air
(driven by single motor) - One (nos.)
Maintenance covers - Six (nos.)
Air inlets for circulating air - Two (nos.)
Air inlets for fresh air - Two(nos.)
Mixed air filters & Fresh air filter - for two (nos.) of each
Air outlet for supply air - One (no.)
Control and safety devices - HP-2,LP-2,OHP-1
ESTI-1,control Pressure-2.Condenser Air Intake Grill
Flexible Conduit For Electrical
Connection To Unit
Electrical Junction Box (One On
Each Side)
Fresh Air Duct
(Canvas/ Latest As Per Rdso
Spec.)
Mounting Bracket
Return Air Duct
View of RMPU with Side Cover Open |Earthing Cable.
Evaporator Motor
Heater Area
Evaporator Motor Unit in RMPUCompressors Copper Heating
Refrigerant Unit
Piping
Evaporator
Motor Unit
Compressors Units in RMPU
RMPU Heating UnitPRESSURE TRANSDUCERSECH, Gwalior
Fresh Air
Damper
Servo Motor
Junction Box
Servomotor Controlled Fresh Air Dampers in RMPU
Phase I! - Module NeTemperature Air Condition — Fault Selector Switch
Selector Off-on Switch Indication For Lp/Hp
Switch Lamp Measurement
Control Panel
Pha:
II - Module No.CH, Gwalior
Micro Controller
Cage Clamp
Connector
Microprocessor Based Controller for RMPU
Phase I! - Module NeThermostat Heating Elements With
Fuseable Cartridge
Heating Unit Elements in RMPUGeneral Data of RMPU components
Compressor
1. Hermetically sealed scroll compressor
u. Each with min 3.5 TR capacity at 60 Deg C
condensing and 5 Deg C evaporating temperature.
i. Total rating of AC package unit not less than 7 Tr.b) Heat Exchangers
i.
il.
Air cooled
Copper tubes with aluminum fins
c) Filters
i.
Each unit has 2 fresh air and 2 mixed air filters
Material is progressively structured, non —
woven break resistant, thermally bonded fire
retardant synthetic material.d) Humidity Control
1. Restricts the humidity level to 60 %
ii. Monitored by Hygrostat
iil. Desired temperature is achieved by switching on
heaters as per logic, such that the combined
power consumption does not exceed the
permissible power under cooling capacity.'e) Sensors
i.
ii.
NTC type sensors
Temperature settings are achieved by rotary switch
provided on the Switch Board Cabinet.
Temperature
Cooling Heating
20.0 Deg C 17.0 Deg C
20.5 Deg C 17.5 Deg C
21.2 Deg C 18.2 Deg C
21.9 Deg C 18.9 Deg C |
Position of switch
22.6DegC | 19.6 Deg C
24.3 Deg C 20.3 Deg C
25.0 Deg C 21.0 Deg C
ala} ufa[wlro)—g) Refrigerating Piping
1. As per drawing.
h) Protections
i. LP, HP cut outs have been provided in the
refrigerant circuit
ii. Overheat protector has been provided in the heater
circuiti
ESTI protection has been provided in the heater
circuit to operate at 130°C in case of failure of
overheat protector for ultimate disconnection of
power supply to heater.
Individual electrical protection has been provided
by MCB’s
In-built overheat protection has also been
provided in the motors windings, which are
interlocked with microprocessor.Ratings of Important Electrical Equipment
S : ‘ Qty/
N Equipment Rating Coach
1 Step down 3 @, 750 V/ 415V AC, 1
Transformer 60kVA
> | Batt 70 Ah, 12 V Monoblock, 9 Mono
aueery Lead Tin/ VRLA blocks
3 [Sealed 30,415 VAC 4
Compressor
4 |Condenser Motor |1 HP, 3 8, 415 V AC 4
5 |Blower Motor 1.5 HP, 3 @, 415 VAC 2Qty/
SN Equipment Rating Coach
6 |Condenser Coil Fin on tube type 4
7 |Cooling Coil Fin on tube type
8 |Heater Unit 3 0, 415 VAC, 6kW 2
9 |Monoblock Pump {3 @, 415 V AC, 0.5 HP 2
Input =: 230V+5%, 10
10 JE Chi 1
eae nee Output: 110V DC
Input: 415V, 3 @, AC
11 |Regulated Charger npn 1
Output: 110 V DC[arn Train LIGHTING EQUIPMENT
* 110V (9 modules of 12 volt, 70Ah) VRLA battery
* Battery fuse box
¢ Battery charger
+ Internal light fittingsIOV (9 modules of 12 volt, 70 Ah) VRLA Battery
fe
Ss
Coaches are provided with 9 modules of 12 volt
70Ah, VRLA battery in series in one battery box.
“ The auxiliary power required for charging is supplied
by a battery charger at constant voltage based as
required by the battery.
** Current limit for battery charging is 20 Amp. on
board charging at constant voltage with the voltage
setting at 122.0 + 1.0 volt.Battery Module Salient Features
Capacity : 12 V 70 Ah (at 27° C) battery module
Container : PP-CP (Polypropylene Co-Polymers)
V2 grade/ ABS FR V2 grade
Rate of Discharge : 10 hr
Overall length : 352 mm
Maximum height : 178 mm
Dimensions width : 170 mm
Maximum weight per module : 26.5 Kg9 Modules Of 12 Volts Each
Total Weight 235 Kg
Battery Box
Clamping Arrgt. ——
End Cell —~7]
ConnectorBattery Fuse Box
Battery fuse box is provided in under frame
supported on brackets by fixing bolts. This box is
properly earthed by earth cable. It is totally covered
and locked by hinged bolts.- Shunt
HRC
Fuses
Clamp
Cage
Connectors
Battery Fuse Box (-ve)Mounting
Cable Entry
Holes
Hall Effect
Transducer
Box Cover
Note :- Hall Effect Transducer has been eliminated and has been
integrated in the regulated battery charger itselfIGBT Based Battery Charger
> It is a 19” switch cabinet rack, force cooled
mounted inside switch board cabinet, with current
and temperature sensors.
» Tt converts transformer’s secondary voltage 30,
415V, AC into 110V, DC for charging battery and
feeding direct voltage loads.
>It has a power capacity of 6.5 Kw.It has following features:
ve
Phase angle control for CVCI charging
Low voltage and current ripples as low as 2% and
THD less than 3%.
Charging dependent on electrolyte temperature which
is monitored by temperature sensor provided inside
battery box.
Soft start and quick shutdownModifications / changes
The Hall Effect transducer provided in Battery fuse
box (to control the charging current of the battery) in
the earlier OEM design coaches has been shifted to
the battery charger itself.
The wiring for the same has also been removedLight Fittings
= Light fittings are provided with injection moulded
and extruded diffuser for defused lighting with
uniformity of illumination and lumen as per UIC
= These fittings are screw less and press fit type.
" Vestibule, toilet, pantry and emergency lighting
works at 110V AC /DC with inverter and poly
carbonate diffusersECH, Gwalior
eading lights are halogen type.
Complete lighting is with high frequency ballast (58
kHz) for flicker free comfort lighting.
Phase IT - ModuleRatings of different lightings
Fluorescent tubes (watt) : 18
Halogen lamp (watt) : 10 (reading lights)Incandescent Lamp
FITTING
AC Duct Panelling
Compartment Light Inside View
Phase IT - Mod:CAMTECH, Gwalior
Inverter/ Ballast
Mounted Along
The Fitting
Fluorescent Light Fitting Inverter
Phase I! - Module No. STC-GS-2Injection Moulded
End Piece
Polycarbonate
Extruded Diffuser
Vestibule Light FittingDoorway Light Fitting
Pha:CAMTECH, Gwalior
Focus Halogen —Off-on Switch Luggage
Adjustment Lamp Rack
Screw Reading Light Fitting
Phase I] - ModuleReading Light Inverter / Ballast
PI ModThank
You