05 - HPL2010-EN. DIL - Removed
05 - HPL2010-EN. DIL - Removed
AC operation DC operation
Rated operational Max. motor rating for Conventional thermal Contact configuration Circuit symbol Can be combined Part no. Price Part no. Price Std. pack Notes
current three-phase motors 50 - 60 Hz current I Ith = Ie AC-1 with auxiliary Article no. See Article no. See
at 60 °C contact price list price list
Ie P P P P P P Ith = Ie
A kW kW kW kW kW kW A
Basic device
Screw terminals
3 pole
7 2.2 3 3.5 1 2.2 2.9 20 1 N/O – A1 1 3 5 13 DILM32-XHI.. DILM7-10(230V50HZ) DILM7-10(24VDC) 1 off Contacts to EN 50 012.
DILA-XHI(V).. 276550 276565 For all DC operated contactors DILM7 - DILM15 the following
A2 2 4 6 14
applies:
7 2.2 3 3.5 1 2.2 2.9 20 – 1 NC A1 1 3 5 21 DILA-XHI(V).. DILM7-01(230V50HZ) DILM7-01(24VDC) • Integrated varistor-suppressor circuit.
276585 276600 For DC operated contactors DILM17 - DILM170 the following
A2 2 4 6 22
applies:
9 2.5 4 4.5 1.5 2.5 3.6 20 1 N/O – A1 1 3 5 13 DILM32-XHI.. DILM9-10(230V50HZ) DILM9-10(24VDC) • Integrated suppressor circuit in actuating electronics
DILA-XHI(V).. 276690 276705 For AC operated contactors DILM115 - DILM170 the following
A2 2 4 6 14
applies:
9 2.5 4 4.5 1.5 2.5 3.6 20 – 1 NC A1 1 3 5 21 DILA-XHI(V).. DILM9-01(230V50HZ) DILM9-01(24VDC) • Integrated suppressor circuit in actuating electronics
276725 276740 For DILM7-01 – DILM38-01 the following applies:
A2 2 4 6 22
• With mirror contact.
12 3.5 5.5 6.5 2 3 4.4 20 1 N/O – A1 1 3 5 13 DILM32-XHI.. DILM12-10(230V50HZ) DILM12-10(24VDC)
DILA-XHI(V).. 276830 276845 1) Electrical lifespan → 5/91
A2 2 4 6 14
AC operation DC operation
Rated operational Max. motor rating for Conventional thermal Contact configuration Circuit symbol Can be combined Part no. Price Part no. Price Std. pack Notes
current three-phase motors 50 - 60 Hz current I Ith = Ie AC-1 with auxiliary Article no. See Article no. See
at 60 °C contact price list price list
Ie P P P P P P Ith = Ie
A kW kW kW kW kW kW A
Basic device
Screw terminals
3 pole
40 12.5 18.5 23 5 9 12 50 – – A1 1 3 5 DILM150-XHI(V).. DILM40(230V50HZ) DILM40(RDC24) 1 off Contacts to EN 50012.
DILM1000- 277766 277780 For all DC operated contactors DILM7 - DILM15 the following
A2 2 4 6
XHI(V).. applies:
50 15.5 22 30 6 10 14 65 – – A1 1 3 5 DILM150-XHI(V).. DILM50(230V50HZ) DILM50(RDC24) • Integrated varistor-suppressor circuit.
DILM1000- 277830 277844 For DC operated contactors DILM17 - DILM170 the following
A2 2 4 6
XHI(V).. applies:
• Integrated suppressor circuit in actuating electronics
65 20 30 35 7 12 17 80 – – A1 1 3 5 DILM150-XHI(V).. DILM65(230V50HZ DILM65(RDC24) For AC operated contactors DILM115 - DILM170 the following
DILM1000- 277894 277908 applies:
A2 2 4 6
XHI(V).. • Integrated suppressor circuit in actuating electronics
72 25 37 35 7 12 17 80 – – A1 1 3 5 DILM150-XHI(V).. DILM72(230V50HZ)1) DILM72(RDC24)1) For DILM7-01 – DILM38-01 the following applies:
DILM1000- 107670 107671 • With mirror contact.
A2 2 4 6
XHI(V)..
1) Electrical lifespan → 5/91
80 25 37 63 12 20 26 90 – – A1 1 3 5 DILM150-XHI(V).. DILM80(230V50HZ) DILM80(RDC24)
DILM1000- 239402 239416
A2 4 6
2
XHI(V)..
95 30 45 75 16 26 35 110 – – A1 1 3 5 DILM150-XHI(V).. DILM95(230V50HZ) DILM95(RDC24)
DILM1000- 239480 239510
A2 2 4 6
XHI(V)..
115 37 55 90 17 28 43 130 – – A1 1 3 5 DILM150-XHI(V).. DILM115(RAC240) DILM115(RDC24)
DILM1000- 239548 239555
A2 2 4 6
XHI(V)..
150 48 75 96 20 33 48 160 – – A1 1 3 5 DILM150-XHI(V).. DILM150(RAC240) DILM150(RDC24)
DILM1000- 239588 239591
A2 4 6
2
XHI(V)..
170 52 90 140 20 33 48 185 – – A1 1 3 5 DILM150-XHI(V).. DILM170(RAC240)1) DILM170(RDC24)1)
DILM1000- 107013 107016
A2 2 4 6
XHI(V).. 3
2 1
Accessories Page
1 Overload relay → Chapter 6
2 Suppressor → 5/54
3 Auxiliary contact module → 5/38
Further actuating voltages → 5/75
Accessories → 5/56
AC operation DC operation
Rated opera- Max. motor rating for Conventional Contact Circuit symbol Part no. Price Part no. Price Std. pack Notes
tional current three-phase motors 50 - 60 Hz free air Article no. See Article no. See
AC-3 AC-3 AC-4 thermal Contact configuration: price list price list
current Ith = Ie = Safety function by
380 V 220 V 380 V 660 V 220 V 380 V 660 V AC-1 at 60 °C
400 V 230 V 400 V 690 V 230 V 400 V 690 V positive opening according
to IEC/EN 60947‐5‐1
Open
Ie P P P P P P Ith = Ie N/O = normally NC = normally
open contact closed contact
A kW kW kW kW kW kW A
Rated Max. motor rating for Conventional Circuit symbol Part no. Price Std. pack Notes
operational three-phase motors 50 - 60 Hz thermal See price
current current Ith = Ie list
AC-1 at 60 °C
AC-3 AC-3 AC-4 Open
380 V 220 V 380 V 660 V 1000 V 220 V 380 V 660 V 1000 V Ith = Ie
400 V 230 V 400 V 690 V 230 V 400 V 690 V
Ie P P P P P P P P A
A kW kW kW kW kW kW kW kW
A1 A11 A1 A11 A1
208201 A4 TX A4
A2 2 4 6 14 22 32 44
300 90 160 195 132 75 132 160 109 350 DILM300A/22(RA250)1) 2)
139556 Directly from the PLC
A 24 V output from (+) L1 (+) L1
the PLC can be (–) N
directly connected (–) N
to the terminals A4/ a
A24. a A10 A2
400 125 200 344 132 92 160 283 132 500 DILM400/22(RA250)3) A10 A2
A11 A1
208209 A11 A1
500 155 250 344 132 112 200 344 132 700 DILM500/22(RA250)3) TY A3
208213 A3 TX A4
A4
24 V
24 V GND
GND
From a low-power command device
580 185 315 560 600 143 250 440 509 800 DILM580/22(RA250)3)
208216 Low-power (+) L1 (+) L1
actuating devices (–) N (–) N
650 205 355 630 600 161 280 494 509 850 DILM650/22(RA250)3) such as PCB relays,
208219 pilot devices or a a
750 240 400 720 800 181 315 556 678 900 DILM750/22(RA250)3) position switches A10 A2 A10 A2
can be directly b b
208222 A11 A1 A11 A1
connected to A10/
820 260 450 750 800 209 355 633 678 1000 DILM820/22(RA250)3) A11. A3 TY A3
208225 A4 TX A4
1000 315 560 1000 1100 260 450 780 1000 1000 DILM1000/22(RA250)3)
267214
1600 500 900 1600 1770 430 750 1300 1650 1800 A1 1 3 5 13 21 31 43 DILM1600/22(RAW250)3) ① Stopping in the event of an emergency (emergency switching off)
106727 ② Max. cable capacitance 6 nF
A2 2 4 6 14 22 32 44
Notes 1) Availability from August 2010. Information relevant for export to North America
Previous DILM185/22 to DILM300/22, see Online Catalog at http://ecat.moeller.net