The BC-30 Vet Auto Hematology Analyzer provides accurate hematology analysis using small sample volumes. It features 23 parameters including eosinophil count and percentage using only two reagents. The compact analyzer has an intuitive touchscreen interface, onboard software, and stores up to 100,000 results. It is suitable for hematology analysis of many species.

Uploaded by

lizlee1209
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views2 pages

BC 30 Vet Brochura

The BC-30 Vet Auto Hematology Analyzer provides accurate hematology analysis using small sample volumes. It features 23 parameters including eosinophil count and percentage using only two reagents. The compact analyzer has an intuitive touchscreen interface, onboard software, and stores up to 100,000 results. It is suitable for hematology analysis of many species.

Uploaded by

lizlee1209
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

BC-30 Vet Auto Hematology Analyzer

Insight and Simplicity

Features
· CBC+4-DIFF, 23 parameters including Eos#, Eos%.
Communication
LAN Port supports HL7 protocol BC-30 Vet
· Throughput:38 T/H (Temperature ≥25C) Support for bi-directional LIS Auto Hematology Analyzer
· Intuitive onboard software with 8.4 inch TFT touch screen
· Temperature control system
· Compact and efficient
· Open vial sampling
Interface
4 USB ports (for external printer, software upgrade, barcode
reader, external WIFI, keyboard and mouse), LAN port (1)
Empowering You Through Simplicity
· 100,000 results storage with histograms
· Original QC, calibrators and reagents Printout
External printer optional

Technical Specifications Operating Environment


Principles Temperature: 10°C~30°C
· Impedance method for WBC, RBC and PLT counting Humidity: 20%~85%
· Cyanide free reagent for hemoglobin test Air pressure: 70kPa~106kPa

Parameters Power Requirement


· 23 parameters: WBC, Neu#, Neu%, Eos#, Eos%, Lym#, Lym%, Mon#, 100V-240V
Mon%, RBC, HGB, MCV, MCH, MCHC, RDW-CV, RDW-SD, HCT, PLT, ≤180VA
MPV, PDW, PCT, P-LCR, P-LCC 50Hz/60Hz
· 4 histograms for WBC, EOS, RBC and PLT NEW
*P-LCC and P-LCR only for dog Dimension and Weight
Dimension: Depth (410 mm) x width (305 mm) x height (400 mm)
Species Weight: ≤20Kg
Dog, Cat, Horse*, Monkey*, Rat*, Mouse*, Rabbit*, Pig*, Sheep*,
Cow*, Goat*, Camel*, Llama*+20 self defined animals
* Coming soon

Reagent
DILUENT
CFL LYSE
PROBE CLEANSER

Sample Volume
Whole blood mode 9uL

Display
8.4 inch TFT Touch Screen

www.mindray.com
P/N:CHN-BC-30 Vet -210285X4P-20190726
©2019 Shenzhen Mindray Bio-Medical Electronics Co.,Ltd. All rights reserved.
Classic Heritage,Intelligence Everywhere Innovative Technology, Elevated Quality
At Mindray we pride ourselves on our dedication and experience in developing better solutions for veterinary labs. Accurate and stable WBC differentiation including Eosinophil using only 2 reagents(Patent
With over 20 years of experience in the hematology field, Mindray has always strived to meet and exceed customers' No. CN201910531135.3)
requirements with innovative solutions. The newly launched BC-30 Vet hematology analyzer is the culmination of that
effort with true 4 part differentiation. Compact yet powerful, full featured yet affordable. Accurate measurement of Eosinophil gives you more diagnostic information
BC-30 Vet utilizes advanced technologies to accurately count Eosinophil
Eosinophilia may suggest allergic reactions (such as allergies, asthma), parasitic infections, skin diseases, blood system
diseases, and other recovery period of infectious diseases, adrenal insufficiency, etc

WIFI Micro sample volume at 9.0μL Reagent Sample


RBC/PLT
No hassle in having Micro sample volume aspiration,
Counting bath Count for RBC/PLT RBCchannel
to connect an extra cable Exclusive parameters including Eos#, Eos%
WBC/HGB

Add lyse for the first time WBC differential WBC channel
LYM Mono Granu
1. Lymphocyte

2. Monocyte
Two-step analysis First time counting
3. Granulocyte
0 100 200

User-friendly interface Add lyse for the Second time Eos

TFT touch screen together with our 4. Eosinophil


powerful software enhances users'
operation and experience Counting bath 0 100 200

Principle of WBC differential

Temperature control system maintains reaction temperature, giving stable results even
Built in printer in cold environment
Timely print out of reports One-button query
without having to setup Simple search by Sample ID yields all BC-30 Vet utilizes a temperature control system to stabilize reaction
a separate printer associated test results and graphics 36
temperature, eliminating the clogging problems and resulting in
in one screen
accurate test results that come from operating in cold environ-

Temperature(C)
27

Counting Bath
9
ments

0
0 10 20 30 40 In low temperature environment, this system maintains the reaction
Room Temperature ( C)  temperature in the proper range, which prevents clogging and
Temperature difference between bath and room temperature ensures more accurate results.
Easy to identify alarm promptly Patented sample
Red, yellow and blue color alarms aspiration button
representing three levels of malfunction, Weekly instead of daily maintenance, lower cost
More convenient and practical
giving you more intuitive and easy to Intelligent maintenance system effectively reduces unnecessary cleaning and cost. Farewell to daily maintenance
observe changes in instrument status
Traditional blood cell analyzers require daily maintenance or risk breakdown due to inadequate maintenance,
which not only increases reagent consumption, but also increases cost. The intelligent maintenance system
allows you to reduce maintenance to every 100 tests or every 7 days, saving time and cost.

The performance is comparable to 5-part hematology analyzer


50 7 5
700
Neu# Lym# Eos# PLT
6 600
40 4
5 500
30 3
4

Lyse stored internally,


400

Flags for abnormal samples


BC-30 Vet

BC-30 Vet

BC-30 Vet
BC-30 Vet
3 2 300
20
y = 0.92x + 0.143 y = 0.96x - 12.01

reagent sensor offers accurate calculation Providing more intuitive clinical information 10 y = 0.946x + 0.475
R2= 0.984
2

1
y = 0.904x + 0.317
R2= 0.805 1
R2= 0.815 200

100
R2= 0.938

Lyse stored internally with sensors that detect volume by different flags 0
0 20 40
0
0 2 4 6 8
0
0 2 4 6
0
0 200 400
60 600 800
and usage, reducing waste and cost BC-5000 Vet BC-5000 Vet BC-5000 Vet BC-5000 Vet

Note: The evaluation benchmark is Mindray BC-5000 Vet