                  3.2.4.2 NE40E-M2K
                          Overview
                          Appearance
                          Components
                          Slot Layout
                          Interface Numbering
                          Fixed Interface Board
                          Technical Specifications
              Overview
                    Product Type        Description               BOM                 Model                Earliest Software
                                                                                                           Version
1 of 9                                                                                                                      3/19/2023, 12:23 PM
HedEx Startpage                                                 http://localhost:7890/printtopics.html?time=Sun Mar 19 2023 12:23:23...
                  Table 1 Device attributes
                  Product Type         Description       BOM               Model                 Earliest Software
                                                                                                 Version
                  NE40E-M2K            NE40E-M2K          02351TQD         CR5B0BKP0391          V800R010C10
                                       Integrated Chassis
                                       Components
                  NE40E-M2K            NE40E-M2K          02351TQD-001     CR5B0BKP0391          V800R011C00
                                       Integrated Chassis
                                       Components E
              Appearance
                  Figure 1 Appearance (DC)
                  Figure 2 Appearance (AC)
              Components
                  Figure 3 Components
                  1. Ground terminal          2. Mounting ear        3. Fan module                         4. PIC
                  5. ESD jack                 6. Cable tray          7. Power supply module                -
                  Figure 4 Components
2 of 9                                                                                                            3/19/2023, 12:23 PM
HedEx Startpage                                                     http://localhost:7890/printtopics.html?time=Sun Mar 19 2023 12:23:23...
                  1. Ground terminal              2. Mounting ear      3. Fan module                           4. PIC
                  5. ESD jack                     6. Cable tray        7. Power supply module                  -
              Slot Layout
                  Figure 5 Slot layout (AC)
                  Figure 6 Slot layout (DC)
                  Slot Name               Slot Quantity              Slot ID                  Remarks
                  Table 2 Description of slot layout
                  Slot Name                   Slot Quantity         Slot ID                     Remarks
                  Slots for PICs              2                     slot 1 to 2                 -
                  Fixed interfaces            1                     slot 3                      -
                  Slot for PSUs               2                     slot 4 to 5                 The device cannot use
                                                                                                both AC and DC power
                                                                                                modules.
                  Slot for a fan module       1                     slot 6                      -
              Interface Numbering
                  Service interfaces on the NE40E-M2K are numbered in the following format: 0/subcard slot
3 of 9                                                                                                                3/19/2023, 12:23 PM
HedEx Startpage                                                             http://localhost:7890/printtopics.html?time=Sun Mar 19 2023 12:23:23...
                  number/interface number on the subcard.
                               A subcard slot number is the number of the slot where an interface's subcard resides.
                               A subcard slot number ranges from 1 to 3.
                               An interface number on the subcard starts with 0, and its maximum value is
                               determined by the actual number of interfaces on the subcard.
              Fixed Interface Board
                   Button                        Description
                  Table 3 Buttons
                   Button                      Description
                   RESET                       This button is used to reset the fixed interface board. Press and hold the
                                               button for 3 seconds or longer, the board is reset, and the SYS-STAT
                                               indicator keeps blinking.
                   Indicator        Name                  Color         Status            Description
                  Table 4 Indicators
                   Indicator Name                     Color       Status             Description
                   SYS-         Working status        Green       Steady on          The device is working normally.
                   STAT         indicator
                                                      Red         Steady on          The device generates a hardware alarm.
                                                                                     You can run the display alarm
                                                                                     hardware command to view the
                                                                                     hardware alarm type.
                                                      -           Off                The device is not running or no power is
                                                                                     input.
                   MGMT-        Service satus         Green       Steady on          The link is up.
                   ETH          indicator
                                                      Green       Blink              Data is being received and transmitted.
                                                      -           Off                The link is down.
                   Interface       Interface     Connector        Description       Cable                Optical Type
                   Name            Type          Type                                                    Supported
                  Table 5 Management interfaces
                   Interface        Interface Type        Connector Description        Cable                Optical Type
                   Name                                   Type                                              Supported
                   0-1              100GE/40GE            QSFP28        Interface for Optical fiber         100Gbps QSFP28
                                                                        100GE/40GE                          optical module
4 of 9                                                                                                                        3/19/2023, 12:23 PM
HedEx Startpage                                               http://localhost:7890/printtopics.html?time=Sun Mar 19 2023 12:23:23...
                  Interface   Interface Type   Connector Description        Cable             Optical Type
                  Name                         Type                                           Supported
                                                         optical signal                       40Gbps QSFP+
                                                         input and                            optical module
                                                         output
                                                         NOTE:
                                                         The 100G port
                                                         on the M2K
                                                         panel supports
                                                         the 4x10GE
                                                         breakout
                                                         function but
                                                         has no
                                                         breakout
                                                         indicator.
                  2-21        10GE             SFP+      Interface for Optical fiber          10Gbps SFP+
                                                         10GE optical                         optical module
                                                         signal input                         10Gbps SFP+
                                                         and output                           CWDM optical
                                                                                              module
                                                                                              10Gbps SFP+ BIDI
                                                                                              optical module
                                                                                              10Gbps SFP+
                                                                                              DWDM optical
                                                                                              module
                  22-31       10GE/GE          SFP+/SFP Interface for Optical fiber           10Gbps SFP+
                                                        10GE/GE                               optical module
                                                        optical signal                        10Gbps SFP+
                                                        or GE                                 CWDM optical
                                                        electrical                            module
                                                        signal input                          10Gbps SFP+ BIDI
                                                        and output                            optical module
                                                         NOTE:                                10Gbps SFP+
                                                                                              DWDM optical
                                                         You can run
                                                                                              module
                                                         the set service-
                                                         mode card-                           1.25/9.953
                                                         bandwidth-                           /10.3125Gbps
                                                         mode                                 SFP+ optical
                                                         command to                           module
                                                         change the
                                                         interface
                                                                                              155Mbps eSFP
                                                         bandwidth                            optical module
                                                         mode. For                            155Mbps eSFP
                                                         details, see                         BIDI optical
                                                         "Commands                            module
                                                         Reference" in
                                                         Reference.
                                                                                              1Gbps electrical
                                                                                              module
                                                                                              1.25Gbps eSFP
                                                                                              optical module
                                                                                              1.25Gbps eSFP
                                                                                              CWDM optical
5 of 9                                                                                                          3/19/2023, 12:23 PM
HedEx Startpage                                               http://localhost:7890/printtopics.html?time=Sun Mar 19 2023 12:23:23...
                  Interface   Interface Type   Connector Description     Cable                Optical Type
                  Name                         Type                                           Supported
                                                                                              module
                                                                                              1.25Gbps eSFP
                                                                                              BIDI optical
                                                                                              module
                  32-41       GE               SFP       Interface for   Optical fiber        155Mbps eSFP
                                                         GE optical                           optical module
                                                         signal input                         155Mbps eSFP
                                                         and output                           BIDI optical
                                                                                              module
                                                                                              1Gbps electrical
                                                                                              module
                                                                                              1.25Gbps eSFP
                                                                                              optical module
                                                                                              1.25Gbps eSFP
                                                                                              CWDM optical
                                                                                              module
                                                                                              1.25Gbps eSFP
                                                                                              BIDI optical
                                                                                              module
                  MGMT-ETH    Ethernet         RJ45      It connects to Super category 5      N/A
                              interface                  an NMS.        shielded twisted
                              (10M/100M                                 pair
                              /1000M Base-
                              TX
                              autonegotiation)
                  Console/AUX Console/AUX RJ45           It connects to 8-core shielded       N/A
                              hybrid interface           the console    cable
                                                         for on-site
                                                         system
                                                         configuration.
                                                         Baud rate:
                                                         9600 bit/s
                                                         (default
                                                         value).
                  TOD         TOD interface    RJ45      One-channel     (Shielded or         N/A
                                                         1PPS+TOD        unshielded)
                                                         time signal     straight-through
                                                         input or        cables
                                                         output/one-
                                                         channel
                                                         DCLS input
                                                         and output
                  CLK         CLK/1PPS         RJ45      Used to input 120-ohm clock          N/A
                              interface                  or output      cable
                                                         2-Mbit/s
                                                         clock signals,
                                                         2-MHz clock
6 of 9                                                                                                           3/19/2023, 12:23 PM
HedEx Startpage                                                            http://localhost:7890/printtopics.html?time=Sun Mar 19 2023 12:23:23...
                   Interface        Interface Type      Connector Description          Cable                 Optical Type
                   Name                                 Type                                                 Supported
                                                                      signals, or 1
                                                                      PPS signals.
                  Fixed interfaces of the HUAWEI NE40E-M2 Series do not support the OTN mode. If a colored optical module is
                  used and does not support optical amplifier insertion, the board supports only point-to-point optical transmission.
                  The Interface Bandwidth Mode
                  NE40E-M2K support two port bandwidth allocation modes: eth-2x100G-30x10GF-10xgf-
                  mode(mode1) and eth-2x100g-26x10GF-14xgf-mode(mode2). By default, the port bandwidth
                  allocation mode is eth-2x100G-30x10GF-10xgf-mode.
                  Figure 7   shows the detials of the interface bandwidth mode.
                  You can run the set service-mode card-bandwidth-mode command to change the interface
                  bandwidth mode. For details, see "Commands Reference" in Reference.
                  Figure 7 The interface bandwidth mode of NE40E-M2K
              Technical Specifications
                   Item                                      Specification
                   Item                                        Specification
                   Dimensions (H x W x D)                      88.1 mm x 442 mm x 220 mm (3.47 in. x 17.4 in. x 8.66
                                                               in.)(2U)
                   Weight (empty)                              2.2 kg (4.85 lb)
                   Weight (full configuration)                            DC:11.0 kg (24.26 lb)
                                                                          AC:12.2 kg (26.90 lb)
                   Cabinet installation standard               ETSI 21-inch; IEC 19-inch
7 of 9                                                                                                                          3/19/2023, 12:23 PM
HedEx Startpage                                           http://localhost:7890/printtopics.html?time=Sun Mar 19 2023 12:23:23...
                  Item                        Specification
                  Typical power consumption              DC:271 W
                                                         AC:309 W
                  Typical heat dissipation               DC:879.2 BTU/hour
                                                         AC:1002.5 BTU/hour
                  DC input voltage                       input voltage range: -40V to -72V
                                                         input rated voltage: -48V/-60V
                  AC input voltage                       input voltage range: 180V to 264V
                                                         input rated voltage: 200V to 240V/100V to 127V
                                                         dual live wires
                  MTBF                        26 years
                  MTTR                        2 hours
                  Availability                0.999999614
                  Slot quantity               2
                  Processing unit             16-core 2.0 GHz
                  Flash                       128 MB
                  SDRAM                       16 GB
                  Storage                     4G NAND FLASH
                  Control Plane Redundant     Fixed-configuration, not pluggable
                  Data Plane Redundant        Unpluggable, no backup
                  Redundant fans              If a single fan fails, the system can still work for a short
                                              period of time at an ambient temperature of 40°C.
                  Redundant power supply      1+1
                  Forwarding performance      410 Mpps
                  Switching capacity          1820 Gbps
                  Operating temperature                  Long-term: DC: -20 °C to 65 °C (-4°F to 149°F)
                                                         AC: 0 °C to 45 °C (32°F to 113°F)
                                                         Short-term: AC: -5 °C to 55 °C (23°F to 131°F)
                                                         Enhance: N/A
                                                         Remark: Restriction on the temperature variation
                                                         rate: 30 °C/hour
                  Storage temperature         -40 °C to 70 °C (-40°F to 158°F)
8 of 9                                                                                                       3/19/2023, 12:23 PM
HedEx Startpage                                                  http://localhost:7890/printtopics.html?time=Sun Mar 19 2023 12:23:23...
                     Item                             Specification
                     Relative operating humidity               Long term: 5% to 85% RH, non-condensing
                                                               Short term: 5% to 95% RH, non-condensing
                     Relative storage humidity        5% to 95% RH, non-condensing
                     Long-term operating altitude     <= 4000 m (13123.2 ft.) (For the altitude in the range of
                                                      1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating
                                                      temperature of the NEU100 must decrease by 1°C [33.8°F]
                                                      for every 220 m [721.78 ft.].)
                     Storage altitude                 Lower than 5000 meters