LTE Radio Access, Rel.
TD-LTE 16, Operating Documentation, Issue 02 (HTML) > LTE
BTS and OMS Descriptions > Flexi Multiradio 10 Base Station TD-LTE RF Module and
Remote Radio Head Description
Flexi Remote Radio Head 8TX 3500 (FZQE)
FZQE technical specifications.
Functional description
Table: FZQE functional specification
Property Value
Output power 8x20 W
MIMO yes, 2TX, 4TX, 8TX
Outdoor installation yes
Beamforming yes
SW supported technology TDD-LTE
Frequency range 3400-3600 MHz
Instantaneous bandwidth 60 MHz
Supported bandwidths 5, 10, 15, 20 MHz
Interfaces
Figure: FZQE interfaces
Table: FZQE interfaces
Label on Number of Connector
Interface Additional info
the HW interfaces type
Power connector DC IN 1 3-pole screw Power delivery
terminal
Grounding 2 2xM5 screw
terminal
Antenna connector ANT 8 4.3-10 type RF signal interface to
connector antenna(s)
Calibration BF 1 N type Beamforming calibration
connector
Remote Electrical Tilt RET 1 RS-485 AISG RET modem with DC
feed
External Alarm Connection EAC 1 RJ45 External alarm input
Optical interface OPT 2 SFP Control and user plane
interface to the System
Module
CPRI, 2 x 9.8 Gbps
Local Management Port LMP 1 RJ45 Local maintenance port for
factory usage only.
Functional block diagram
Figure: FZQE functional block diagram
Electrical specifications
Table: FZQE electrical specifications
Property Value
Nominal supply voltage -48.0 V DC
Nominal input voltage range -40.5 V DC to -57.0 V DC
Extended input voltage range -36.0 V DC to -60.0 V DC
This module contains an integrated overvoltage protection (OVP).
Power consumption
Table: FZQE power consumption
Estimated power consumption [W] at 48 V DC input at 23°C. Non-
committed estimated values depend on the final product HW and
RF output SW optimization with +/-10% margin.
Number of TXs power per TX
[W]
55% TX duty 68% TX duty
8 20 523 600
10 361 400
5 297 320
2 232 240
4 20 361 400
10 281 300
5 248 260
2 216 220
2 20 281 300
10 240 250
5 224 230
2 208 210
Installation and mechanical specifications
Table: FZQE installation and mechanical specifications
Property Value
pole/wall installation
Installation options
directly on the wall installation
IP rating IP65
Dimensions and weight
Table: FZQE dimensions and weight
Property Value Dimensions orientation
Height 342 mm (13.5 in.)
Depth 150 mm (5.9 in.)
Width 464 mm (18.27 in.)
Weight 22 kg (48.5 lbs)
Environmental specifications
Table: FZQE environmental specifications
Property Value
Maximum operational temperature +55°C (131°F)
Minimum operational temperature -40°C (-40°F)
LEDs
Table: FZQE LEDs
LED status Description Alarm
RRH - red, stable A critical alarm has occurred or a reset is ongoing (red Critical alarm
stable for max. 5 s, then yellow stable).
RRH - red, blinking A major or minor alarm has occurred. Major or
minor alarm
RRH - yellow, stable Module is on and the status is set to ‘waiting’ or ‘blocked’. No alarm
RRH - yellow, blinking SW download is in progress or configuration is ongoing. No alarm
Module is non-operational at the moment.
RRH - green, stable Module is operational. No alarm
RRH - green, blinking Module is loading software or parameters. No alarm
RRH OPTx port - green, stable SFP link is connected to the System Module or extension No alarm
sub-module.
RRH OPTx port - red, stable SFP is installed, but no fiber or link is present. No alarm
RRH OPTx port - switched off No SFP or SFP power is down. No alarm
RRH TX - green, stable PA power is on. No alarm
RRH TX - green, blinking PA power is off. No alarm
Warnings, cautions or notes related to the product
WARNING! Risk of electric shock.Before turning RF power on, RF ports have to be terminated by
nominal 50Ω load (for example, feeder with antenna). However, if these conditions are not met, the
plastic caps that are delivered within the unused RF ports should remain in place. The plastic caps
isolate RF power from the environment, and thus provide electric shock security in case RF power is
accidentally on.
NOTICE: The RRH should always be mounted in a vertical orientation with connectors on the bottom
side to ensure convection cooling.
Note: The minimum startup voltage is 40.5 V DC. If the input voltage is below/beyond extended
limits, unit might shut down.
Id: © 2016 Nokia Solutions and Networks. All rights reserved.
DN09135257