TORK Nsi Guide
TORK Nsi Guide
VDC
                                                                                M   +24
                                                                             CO
                                               E                       M
                                         E SID               CH
                                                                4
                                                                    CO
                                       G
                                  LTA CH 2 CH
                                                3
                              V O
                        L O W     CH
                                     1
                             ORS
                           SEN
                        TO
      2
                  P H O
   EPC
                                                                                            E
                                                                                        BLU
                                                                                             M
                                                                                         CO
                                                                        E
                                                                    BLU MON
                                                                       O M
                                                                     C
                                                      E
                                                   BLU MON                      NG
                                                                                   E
                                                       M
                                                    CO                      ORA          NO
                                                              E
                                                            NG NO
                                 E
                              BLU MON                   ORA
                                  M
                               CO
                          NO                NG
                                               E
                    NGE                 ORA        NO
                ORA
                                                                                 -24
                                                                         A 2 00RRIDE)         S
                                                                       SS OVE 3
                                                                               R
                                                                           (CH
                                        4                                              RED
                                   0R 2
NOVEMBER 2008
DESCRIPTION
Self contained transformer and relay with SPST dry contacts rated at 20 AMP 120VAC, or
277VAC. Internal power source provides for low voltage control of line voltage contacts, thus
eliminating the need for a separate step down transformer.
For multi-channel digital controls, TORK offers output panels, available in groups of 4 or 8
SPECIFICATIONS
Contacts:                 SPST Dry Contacts
Contact Rating:           20 Amps Ballast
                          20 Amps Incandescent (at 120VAC)
                          20 Amps General Purpose
                          1.0 Horsepower @ 120VAC
Temperature Range:        0° to 150°F (-18° to 66°C)
                                     LOW VOLTAGE 2
                                    CONDUCTOR 22GA
                                     CLASS 2 WIRING                                                              N
                                                                                                 INPUT VOLTAGE
                                                                                                                 L
MAINTAINED CONTACT
 FROM MANUAL OR                                                     TRP
    TIME SWITCH                                                                                                   N
   (DRY CONTACT)                                                                                       L
                                                                                                                 N
                                                                                                 INPUT VOLTAGE
                                                                                                                 L
TRP
                                                                                                   L
                                                                                                                 N
NOVEMBER 2008                                                                                                         1
                                                 A DIVISION OF        NSi INDUSTRIES, LLC
LOW VOLTAGE CONTROL OF LIGHTING USING
TRANSFORMER RELAY POWERPACKS
                                                                               TORK TIME SWITCH
                                                                                 (DRY CONTACT)
                                                                                       BLACK
                                                                                BLUE
                                                                                               RED
                 NEUTRAL   WHITE
                           BLACK
                    LINE
                           RED                   TRP-D
                           RED
                                                                                       BLACK
                                                                                BLUE
RED
                 NEUTRAL   WHITE
                           BLACK
                    LINE
                           RED                   TRP-D
                           RED
                                                                           LOW VOLTAGE WIRING
                                                                             MINIMUM 22 AWG
                                                                         MAXIMUM LENGTH OF 500FT
Low voltage wiring:                If three-way switching is required         Standard wall switch or any digi-
Minimum 22AWG                      (eliminate standard wall switch)           tal time switch
Maximum length of 500ft
TRP-D 120 / 277 Vac =
   20amps ballast
   20amps incandescent
2
                                                                                                                          APPLICATIONS GUIDE
SWITCHING LOADS HIGHER THAN THE
TIME SWITCH CONTACTS: SINGLE CIRCUIT CONTROL
For control by TORK digital time switches or lower
amperage mechanical time switches where switching
of higher load capacity is necessary. For example, 1.0
HP exhaust fan is switched by a TORK controller using
simple low voltage wire. TRP may be installed remote                                            TORK DIGITAL CONTROL
from digital controller up to 500’ with #22 AWG low                                               TERMINAL BLOCK
voltage wire.                                                                                  NO        C        NC
                                                                                                                    not used
                                                                                                    BLACK
                                                   WHITE
BLUE
                                                                                                                                  RED
                                 NEUTRAL
                                                   BLACK
                                    LINE           RED                TRP-D
                                                   RED
LOAD
1.0 HP MOTOR
RED
                                                    WHITE
                                   NEUTRAL
                                                    BLACK
                                       LINE         RED                TRP-D
                                                    RED
LOAD
                                                                       1.0 HP MOTOR
                                                                                                                               not used
                                                                                                            BLACK
                                                                                                   BLUE
                                                    WHITE
                                                                                                                                          RED
                                   NEUTRAL
                                                    BLACK
                                       LINE
                                                    RED                TRP-D
                                                    RED
                                                                                                                                                3
                                                                                                                                                3
NOVEMBER 2008                                    A DIVISION OF        NSi INDUSTRIES, LLC
TYPICAL WIRING WITH TORK DIGITAL CONTROL
SWITCHING 208-240 VOLTS
WITH NEUTRAL: USING 2 TRP-D’S
To control 2 separate 120V circuits using 240V 3
wire lines. TORK digital controller is wired to 2
TRP-D’s using low voltage switching. TRP-D’s may be                                   TORK DIGITAL CONTROL
installed remote from digital controller up to 500’ with                                TERMINAL BLOCK
#22 AWG low voltage wire.
                                                                                     NO        C         NC
                                                                                                     not used
                                                                                         BLACK
                                                                                  BLUE
                                                                                                                RED
                                        WHITE
                   N
                                        BLACK
                   L1                   RED                    TRP-D
                                        RED
                   L2
LOAD
                                                                                                     not used
                                                                                         BLACK
                                                                                  BLUE
                                        WHITE
                                                                                                                RED
                                        BLACK
                                        RED                    TRP-D
                                        RED
LOAD
                                                           3           4     5                   6
                                   L1
                                            208 OR 240VAC
                                   L2
LOAD
4
                                                                                                               APPLICATIONS GUIDE
SWITCHING HIGHER VOLTAGE AND/OR
AMPERAGE USING CONTACTORS
To control 120 volt circuits where increased voltage                TYPICAL WIRING WITH TORK CONTACTORS
and/or amperage switching is necessary, close to or                 5401, 5440 AND OTHER CONTROL SYSTEMS
remote from controller. Can switch up to 40 amps per
pole from 120VAC to 480 VAC, one or two circuits              TORK DIGITAL CONTROL
simultaneously. Indoor-outdoor enclosure.                       TERMINAL BLOCK
                                                             NO        C        NC
                                                                                          MECHANICALLY HELD CONTACTOR
                                                                                          SELF CLEARING
                                                                                                OPEN
                                           LINE
                                                                                                CLOSE
                                                  120VAC
NEUTRAL C
120VAC COIL
TORK’s model 5441 contains 4-3PST contactors - 40                   TYPICAL WIRING WITH TORK MODEL 5441
Amp contacts - 8VA coil power per contactor - 120                   MULTIPLE ELECTRICALLY-HELD CONTACTORS
VAC. Electrically-held in one enclosure (indoor only).
Wire close to or remote from controller. Up to 4
contactors may be parallel wired to 1 circuit; time                    TORK TIME SWITCH
controlled, indoor lighting, motor loads, ventilating                   TERMINAL BLOCK
systems, refrigeration ambient defrosting.                      NO     C    NC     NO   C           NC
NEUTRAL
                                                                                           LINE 120/240/277/480VAC
                                                                                           LOAD 40A MAX PER POLE
                                                                                                                        CIRCUIT 2
120VAC COIL
LINE 120/240/277/480VAC
NOVEMBER 2008                                                                                                                                                   5
                                                    A DIVISION OF         NSi INDUSTRIES, LLC
SINGLE CHANNEL
CONTROLLING                                                                      TORK DIGITAL CONTROL        TORK DIGITAL CONTROL
TWO DIFFERENT                                                                         CIRCUIT #1                  CIRCUIT #1
CIRCUITS ALTERNATELY NO C NC NO C NC
                                                                                                                                    LOAD TO Security
Combination day-time control of lighting/night-                                                                                     & Alarm System
time control of security system.                                                                                                    LINE FROM Security
                                                      LINE                                                                          & Alarm System
Use NC of circuit 2 to turn “ON” security sys-                120VAC
tem when circuit 1 turns “OFF”.                                                                  TORK MODEL 5401 CONTACTOR
                                                  NEUTRAL                                                   3PST
                                                                                                        Lighting Load
120VAC COIL
                                                                                             LINE 120/240/277/480VAC
                                                                                             LOAD 40A MAX PER POLE
                                                                                                                                                  CIRCUIT 1
can provide remote timed override of up to 12
                                                         NEUTRAL
hours. A flicker/beep warning can be selected
prior to turn-off.
                                                                                                                   120VAC
                                                                                                                   COIL
                                                                                                                   LINE 120/240/277/480VAC
                                                TORK                                                               TORK MODEL 5401 CONTACTOR
                                                A500 SERIES                                                        3PST
                                                INTERVAL
                                                TIMER
                                                                                                                        LOAD 40A MAX PER POLE
                                                                 OR
                                                  TORK SSA 100/200 SERIES
                                                                                                                                                  CIRCUIT 2
                                                                          BLACK
                                                                                                                   120VAC
                                                                          RED                                      COIL
                                                                                                                   LINE 120/240/277/480VAC
                                                                          GREEN                                    TORK MODEL 5401 CONTACTOR
                                                                                                                   3PST
6
                                                                                                                                  APPLICATIONS GUIDE
CONVERT MAINTAINED TO
MOMENTARY CONTACT
                                                                                                     TORK DIGITAL CONTROL
The SMC-3D will operate low voltage                                                                     TERMINAL BLOCK
latching relays or mechanically held                                                               (MAINTAINED CONTACT INPUT)
contactors with or without remote manual           SMC-3D                                                   NO        C      NC
push button override.                              INPUT: SUSTAINED VOLTAGE 120VAC                                                 H
                                                   MOMENTARY CONTACTS (UNPOWERED)                                                  N
                                                                                                                                     120VAC
The adapter converts a constant applied            30A INRUSH:
                                                         120VAC, 240VAC
120VAC (input) to a 2 second con-
                                                         277VAC, 30VDC           SMC-3D                         120VAC
tact closure at the “ON RELAY” output
closing common and normally open                                                               ON RELAY          OFF RELAY
                                                                                              NC NO C           NC NO C
(C, NO). When the constant applied
120VAC input opens, a 2 second con-
tact closure at the “OFF RELAY” output                                   ON PULSE                                                                     PUSH
between common and normally open (C,            LOW VOLTAGE                                                                                           ON
                                                LATCHING RELAY
NO) occurs. The SMC-3D can be oper-             OR MECHANICALLY          OFF PULSE
ated by any TORK time controller or a           HELD CONTACTOR                                                                                        PUSH
                                                                                                                  H                                   OFF
remote manual SPST standard constant                                      NEUTRAL
                                                                                                       120VAC
                                                                                                                  N
“ON-OFF” switch.
                                                                                                                            TORK DIGITAL CONTROL
                                             ELECTRICALLY HELD CONTACTOR OR MOTOR STARTER                                      TERMINAL BLOCK
The SMC-3D with pulse “ON” an electri-              L       L       L                                                     (MAINTAINED CONTACT INPUT)
cally held contactor or motor starter with                                                                                        NO        C    NC
self contained “ON-OFF” push buttons.
                                                                                                                                                      H
“ON” relay will pulse 2 second “ON”                                                                                                                     120VAC
                                                                                     120VAC COIL                                                      N
and electrically hold the contactor “ON”.
By interrupting the holding circuit of the                                      AUX
contactors “OFF” button across com-
                                                                                                                 SMC-3D            120VAC
                                                                                CONTACTS
mon and normally closed (C, NC) of the                                                                            ON RELAY         OFF RELAY
SMC-3D “OFF” relay the 2 second open-                                                                            NC NO C          NC NO C
ing of common and normally closed (C,                                                                                                           REMOTE SWITCHES OPTIONAL
NC) will allow the electrically held con-        LOAD    LOAD     LOAD
                                                                                                   N
                                                                                                                                                              PUSH
tactors to open, thereby going “OFF”.                                                                                                                         ON
                                                   N       N       N
                                                                                                                                                              PUSH
                                                                                                                                                              OFF
NOVEMBER 2008                                                                                                                                                        7
                                                        A DIVISION OF                 NSi INDUSTRIES, LLC
4 ZONE LIGHTING CONTROLLER WITH PHOTO SENSOR INPUT
AND DRY CONTACT REMOTE OVERRIDE INPUTS
The DLC400BP is a multi-voltage, dedicated 4 zone
lighting controller with photocell input in a NEMA
3 Enclosure. The unit has 30 AMP SPDT heavy duty
contacts, therefore eliminating the need for costly
contactors in most application. Each zone can be
actuated by 1) The photosensor, or 2) Time of day,
or 3) A combination of both. Light level setting at
which lights turn on and off as well as time sched-
ules are assigned independently to each zone, with
the additional capability of remote override inputs
from external switches or local override at the key-
pad.
8
                                                                                                                                 APPLICATIONS GUIDE
UNIVERSAL INPUT
FROM PHOTOCELL                                 TORK MODEL DGUM 100                                                  TORK MODEL DGU 100
                                                                   TERMINAL BLOCK                                                   TERMINAL BLOCK
                                          CLOCK                 (MOMENTARY CONTACTS)                            CLOCK            (MOMENTARY CONTACTS)
                                          INPUT               DRY CONTACTS (UNPOWERED)                          INPUT          DRY CONTACTS (UNPOWERED)
                                          H       N   NO        C    NC   NO      C       NC                    H     N   NO      C    NC            SELF CLEARING
                                                                                                                                              MECHANICALLY HELD CONTACTOR
                                                                                                                                                    OPEN
                                                                ON                OFF                       H
                                                                                                                                                    CLOSE
                                                                                                            N                                       C
Single channel time switch accepts
remote input from any dry maintained
contact closure and photocell or ther-                                                                                                 TORK EPC1
mostat. Use to control outdoor lighting
                                                                                                                                                            OR MAINTAINED SWITCH
                                                                                                                                                             USE EITHER PHOTOCELL
                                                                                                                                                               (BUT NOT BOTH!)
or HVAC.                                                                                                                                     PHOTO
                                                                                                                                            CONTROL
                                                  REMOTE INPUT                                                        REMOTE INPUT
                                                  1       2      3                                                    1    2      3
NOVEMBER 2008                                                                                                                                                                       9
                                                      A DIVISION OF                   NSi INDUSTRIES, LLC
COMBINATION PHOTOCONTROL/TIMED ON-OFF SWITCHING
OF GREATER LOAD CAPACITIES
To control lighting circuits where a
Photocontrol turns “ON” at dusk (controller                           TORK
                                                                  PHOTOELECTRIC
should be set for “ON” before dusk) and
                                                                    CONTROL          TORK DIGITAL CONTROL
“OFF” by preset times of 120VAC control-                                               TERMINAL BLOCK
ler. Controller can be set to turn “ON” early
                                                                                       NO     C       NC
a.m. before dawn, and have Photocontrol                                  PHOTO
turn “OFF” at dawn…turn back “ON” at                                    CONTROL
dusk, and controller turns lights “OFF” during                                                                  TORK MODEL 5401 CONTACTOR
nights when lighting is no longer needed.            TORK MODELS
                                                                                                                   LOAD 40A MAX PER POLE
                                                  2000 / 2001 / 2021
Photocontrol can be wired direct to 120VAC           2101 / 3000
control circuits.
                                                                       WHITE
                                                                       BLACK
                                                                               RED
                                                     NEUTRAL                                      120VAC COIL
                                                             120VAC
                                                      LINE
LINE 120/240/277/480VAC
LIGHTING CONTROLLER
INDEPENDENT LIGHT LEVEL/TIME-OF-DAY OPERATION OF TWO
LIGHTING ZONES (I.E. 2 LEVEL ATRIUM LIGHTING)
The LC200 consists of an electronic control
and an electronic light sensor interacting. The
unit offers separate control of two lighting
zones, each with user settable on/off light
level setpoints. The Electronic control also
offers two digital inputs which will accept
a contact closure from any Tork Timer(s), or
existing EMS system to provide for indepen-
dent Time-Of-Day override.
10
                                                                                                                                                  APPLICATIONS GUIDE
DIGITAL LIGHTING CONTROLLER
MODEL DGLC
1. For wiring to electrically-held contactor - see Fig. 1
2. For coil clearing mechanically-held contactor - see Fig. 2
3. Fig. 1 and Fig. 2 - one circuit can be used to control electronically-held contactor while the other circuit controls
  a mechanically-held contactor.
FIG. 1
                                                                                                               WHITE
                                                                                                               WHITE
                 LINE
                                                                                                   TORK MODEL 5401 CONTACTOR
                   120VAC (DEDICATED)                                                              (OR OTHER ELECTRICALLY HELD CONTACTOR)
                 NEUTRAL                                                                           LINE 120/240/277/480VAC
                                                                                         120VAC
                                                                                            COIL
                 LINE
                   120VAC
                                                                                                       LOAD 40A MAX PER POLE
                 NEUTRAL
                                                                                                   LINE 120/240/277/480VAC
                                                                                         120VAC
                                                                                            COIL
                                                                                                                   WHITE
                LINE                                                                                               WHITE
                  120VAC (DEDICATED)
                NEUTRAL                                                                                                    SELF CLEARING
                                                                                                                    MECHANICALLY HELD CONTACTOR
OPEN
                                                                                                                            CLOSE
                LINE
                  120VAC                                                                                                    C
                NEUTRAL
                                                                                                                           SELF CLEARING
                                                                                                                    MECHANICALLY HELD CONTACTOR
                                                                                                                      WHITE
momentary contact adapter. For operation of mechan-
                                                                                                                                          H
ically-held contactors and low voltage relays where
                                                                                                                              120VAC
remote momentary push button stations are necessary                                                                                       N
or already exist.
                                                                            SMC-3D
                                                                                            120VAC
                                         MOMENTARY CONTACTS
                                         ADAPTER SMC-3D                      ON RELAY
                                                                            NC NO C
                                                                                            OFF RELAY
                                                                                           NC NO C
                                                                ON PULSE                                                               PUSH
                                     LOW VOLTAGE                                                                                       ON
                                     LATCHING RELAY
                                     OR MECHANICALLY            OFF PULSE
                                     HELD CONTACTOR                                                                                    PUSH
                                                                                                 H                                     OFF
                                                                                  120VAC
                                                                 NEUTRAL                         N
12
                                                                                                                      APPLICATIONS GUIDE
                                            LINE
                                                                                            BLACK
                                                                                             RED              RELAY GE RR-7
                                                                                                              OR EQUIVALENT
                                            NEUTRAL                                          BLUE
                                                                  OPTIONAL HALF-WAVE
                                                                   RECTIFIER - 24VAC
                                             TORK MODEL TA 1245Y-75
                                               (75VA TRANSFORMER)
                                                       LINE
                                                       120VAC
                                                       NEUTRAL
                                                                                                     TORKALERT™
                                                                TORK MODEL TA599                    24 VAC HORNS
                                                               TRANSFORMER (40VA)                TA874-G5, TA876-G5
NOVEMBER 2008                                                                                                                          13
                                                              A DIVISION OF        NSi INDUSTRIES, LLC
TIMED OVERRIDE “ON” FOR LIGHTING, HVAC
WITH WARNING OFF INDICATION
COVERS FROM 120 THRU 277 VAC
The LDS / LDS-A is an accessory to any TORK main-                                The LDSH / LDSH-A is an accessory to any TORK
tained contact time switch and is used to extend the                             maintained contact time switch and is used to extend
lighting time after the main time switch turns OFF a                             the time on of lighting, HVAC, and other main build-
lighting circuit. An approximate _ second blink will                             ing loads after the time switch turns OFF. An auxiliary
occur as a warning that the lighting will go OFF in (user                        contact closes, turning on a user selected signal device
selectable) 1 or 5 minute warning period.                                        (i.e. bell, horn, light, or other warning device), which
                                                                                 turns off along with the main load at the end of the user
Remote momentary ON/OFF push button switches can                                 selected 1 or 5 minute warning period.
be connected to the designated terminal of the Lighting
Delay Switch using low voltage # 18 - 22 AWG twisted                             Remote momentary ON/OFF push button switches can
pair wires. Pressing the remote ON button momentarily                            be connected to the designated terminal of the Lighting
during the 1 or 5 minute warning period (before the                              Delay Switch using low voltage # 18 - 22 AWG twisted
lights go out) will extend the time ON for a user select-                        pair wires. Pressing the remote ON button momentarily
able _ hour, I hour, 1-1/2 hour, 2 hours, 6 hours, 9                             during the 1 or 5 minute warning period will extend
hours, or 12 hours. At the end of the extended time a                            the time on (main load) for a user selectable 1/2 hour,
warning blink will again occur, allowing personnel to                            1 hour, 1 1/2 hour, 2 hours, 6 hours, 9 hours or 12
repeat another 12 hour extension if necessary. Pressing                          hours. At the end of the extended time, the user selected
the remote OFF button for 3 to 4 seconds will terminate                          signal device will turn on again, allowing personnel
the extension of time, and initiate the warning blink.                           to repeat another 1/2 hour – 12 hour extension of the
The lights will turn OFF after the 1 or 5 minute warning                         main load. Pressing the remote off button for 3 to 4
period.                                                                          seconds will terminate the extension of time for the main
                                                                                 load and warning circuit. The main load and warn-
                                                                                 ing circuit will turn off after the 1 or 5 minute warning
                                                                                 period.
14
                                                                                                                                           APPLICATIONS GUIDE
                                                                             C    NO         NC          C       NO              NC   C   NO       NC     C    NO    NC
                                                          not used
                                                          BLACK
        N      WHITE
               BLACK
        L
DRY CONTACTS   RED
                                TRP-D                     BLUE
  TO LOAD      RED
                                                          RED                            not used
                                                                                         BLACK
                                 N       WHITE
                                         BLACK
                                 L
                         DRY CONTACTS
                                                             TRP-D                       BLUE
                                         RED
                           TO LOAD       RED
                                                                                         RED
                                                                                                                      not used
                                                                                                                      BLACK
                                                         N             WHITE
                                                                       BLACK
                                                         L
                                                                                        TRP-D                         BLUE
                                                 DRY CONTACTS          RED                                            RED
                                                   TO LOAD             RED
                                                                                                                                               not used
                                                                                                                                               BLACK
                  TRP-D INPUT VOLTAGE : 120 /- 277 VAC                                   N             WHITE
                                                                                                       BLACK
                                                                                         L
                                                                                                                           TRP-D               BLUE
                                                                                 DRY CONTACTS          RED                                     RED
                                                                                   TO LOAD             RED
APPLICATIONS:
  SWITCH CAPACITY
  20A Ballast
  20A Incandescent (at 120VAC)
  20A General Use
  1.0HP at 120VAC
NOVEMBER 2008                                                                                                                                                         15
                                                                     A DIVISION OF                  NSi INDUSTRIES, LLC
TYPICAL WIRING WITH 5401 OR 5441
FOR SWITCHING OF GREATER LOADS
DRY CONTACT OUTPUT
C NO NC C NO NC C NO NC C NO NC
     L
         120 VAC
     N
LOAD 40A MAX PER POLE LOAD 40A MAX PER POLE LOAD 40A MAX PER POLE LOAD 40A MAX PER POLE
APPLICATIONS:
16
                                                                                                                                     APPLICATIONS GUIDE
                                                                                    M
Typical wiring with TORK electromechanical time switch
for automatic switching of POULTRY HOUSE lighting.
Bright lighting to simulate daylight - dim lights for roost-
ing.                                                                                                                           LOW VOLTAGE
                                                                                                                             AUXILLARY SWITCH
                                                                              L            1           X         2               NO             C
                                                                                  BRIDGE
                                          L
                                              120VAC
                                          N
                                                                                   BRIGHT LIGHTING
                                                                                  UP TO 4000 WATTS
                                                                                    DIM LIGHTING
                                                                                  UP TO 2000 WATTS
                                                                                                                                                    not used
                                                                                                                                      BLACK
                                                                                                                                                    BLACK
                                                                                                                              BLUE
                                                                                                                                              RED
                                                                 WHITE
                                                                 BLACK
                                                                 RED
                                                                                      TRP-D
                                                                 RED
                                                                                                   BRIDGE
                                                          L
                                                                 120VAC
                                                          N
                                                                                       SMC-3D
                                                                                                                120VAC
                                                  MOMENTARY CONTACTS
                                                  ADAPTER SMC-3D                        ON RELAY
                                                                                       NC NO C
                                                                                                                 OFF RELAY
                                                                                                                NC NO C
                                                                          ON PULSE                                                                             PUSH
                                               LOW VOLTAGE                                                                                                     ON
                                               LATCHING RELAY
                                               OR MECHANICALLY            OFF PULSE
                                               HELD CONTACTOR                                                                                                  PUSH
                                                                                                                     H                                         OFF
                                                                                                      120VAC
                                                                           NEUTRAL                                   N
NOVEMBER 2008                                                                                                                                                         17
                                                         A DIVISION OF                NSi INDUSTRIES, LLC
MECHANICAL TIME SWITCHES AND PHOTOCONTROL
OPERATING WITH MOMENTARY CONTACT SYSTEM
                                                                                                                                               TORK MODELS
TORK Model 2000, 2001 or 2101 photocontrol is                                                                                                2000/2001/2021
wired in series with Model 1101 or 1102 time switch                                             TORK 1101 SPST                                  2101/3000
for photocontrol ON/timed OFF in connection with an
SMC-3D momentary contact adapter. For operation of
mechanically-held contactors and low voltage relays             REMOVE BRIDGE FROM                      M                                            PHOTO
where remote momentary push button stations are nec-
                                                                  TERMINALS L & 1                                                                   CONTROL
essary or already exist.                                                                            L      1      X          2
                                                                      L
                                                                                                                                               BLACK
                                                                                                                                               RED
                                                                          120VAC
                                                                      N                                                                        WHITE
                                                                                               SMC-3D
                                                                                                                 120VAC
                                                      MOMENTARY CONTACTS
                                                      ADAPTER SMC-3D                            ON RELAY
                                                                                               NC NO C
                                                                                                                  OFF RELAY
                                                                                                                 NC NO C
                                                                                   ON PULSE                                                                   PUSH
                                                   LOW VOLTAGE                                                                                                ON
                                                   LATCHING RELAY
                                                   OR MECHANICALLY                 OFF PULSE
                                                   HELD CONTACTOR                                                                                             PUSH
                                                                                                                      H                                       OFF
                                                                                                        120VAC
                                                                                    NEUTRAL                           N
                         L                                      BLACK
                             120VAC
                                                                WHITE
                         N
                                                                RED
                                                                                                                          NOT USED
                             LIGHTING LOAD
                                                                                                                          BLACK
                                                                                                                                            BLACK
                                                                                                                                     BLUE
                                20A MAX
                                                                                                                                                    RED
                                                      WHITE
                                                      BLACK
                                                                                    TRP-D
                                                          RED
                                                          RED
18
                                                                                                                             APPLICATIONS GUIDE
                                               L
                                                   120VAC
                                               N
                                                                       SMC-3D
                                                                                          120VAC
                                    MOMENTARY CONTACTS
                                    ADAPTER SMC-3D                      ON RELAY
                                                                       NC NO C
                                                                                          OFF RELAY
                                                                                         NC NO C
                                                           ON PULSE                                                              PUSH
                                 LOW VOLTAGE                                                                                     ON
                                 LATCHING RELAY
                                 OR MECHANICALLY           OFF PULSE
                                 HELD CONTACTOR                                                                                  PUSH
                                                                                            H                                    OFF
                                                                                120VAC
                                                            NEUTRAL                         N
                             L
Use TRP-D for direct
                                  120 OR 277 VAC
switching of remote          N
lighting loads by
photocontrol / time
switch.
                                      LIGHT               LIGHT
                                     FIXTURE             FIXTURE          WHITE                                          BLACK
Applicable for                                                            BLACK                                          BLUE
20 Amp Ballasst                                                                               TRP-D                      RED
                                                                          RED
20 Amp Incandescent                                                       RED
  (at 120VAC)
                                                   RED
                                                   BLUE
                                                   BLACK
                                                                                                LOW VOLTAGE
                                                                                                3 CONDUCTOR 22GA CLASS 2 WIRING
NOVEMBER 2008                                                                                                                               19
                                                     A DIVISION OF                NSi INDUSTRIES, LLC
FOR MULTI CIRCUIT CONTROL, A MAXIMUM OF 5 TRP-D
POWERPACKS CAN BE CONNECTED TO ONE OSC5U/OSC10U/
OSC20U/OSCW5P/OSCW15P/OSC2UP
SENSOR
      L
            120 OR 277 VAC                WHITE
      N                                                                   BLACK
               LIGHT             LIGHT    BLACK
              FIXTURE           FIXTURE           TRP-D                   BLUE
                                                                          RED
                                          RED
                                          RED
      L
            120 OR 277 VAC                WHITE
      N                                                                   BLACK
               LIGHT             LIGHT    BLACK
                                                                          BLUE
              FIXTURE           FIXTURE           TRP-D                   RED
                                          RED
                                          RED
      L
            120 OR 277 VAC                WHITE
      N                                                                   BLACK
               LIGHT             LIGHT    BLACK
                                                                          BLUE
              FIXTURE           FIXTURE
                                          RED
                                                  TRP-D                   RED
                                          RED
                             RED
                             BLUE
                             BLACK
                                                          LOW VOLTAGE
                                                          3 CONDUCTOR 22GA CLASS 2 WIRING
                                                          (CONNECT ALL LIKE-COLORED WIRES)
20
                                                                                                                                                APPLICATIONS GUIDE
           LOW VOLTAGE
           3 CONDUCTOR 22GA CLASS 2 WIRING
           (CONNECT ALL LIKE-COLORED WIRES)
                        RED                                     RED                                               WHITE                     N
                        BLUE                                    BLUE                                              BLACK                       120 VAC
                                                                                                                                            L
                                                                                            TRP-D                 RED
                        BLACK                                   BLACK                                             RED
              SELECT A TRANSFORMER
                 SUFFICIENT TO DRIVE
            THE NUMBER OF LATCHING
                         RELAYS USED
            UP TO 20 LATCHING RELAYS
      CAN BE SWITCHED BY ONE SMC-3D
                                          TO LOAD
TO LOAD
TO LOAD
TO LOAD
TO LOAD
TO LOAD
NOVEMBER 2008                                                                                                                                                               21
                                                                    A DIVISION OF               NSi INDUSTRIES, LLC
TIME SWITCH DETERMINING PERIODS DURING
WHICH OCCUPANCY SENSOR IS OPERATING
                                                                                                                  TORK TIME CONTROL
                                           L                                                                       TERMINAL BLOCK
                                               120 OR 277 VAC
                                           N                                                                       NO       C             NC
                                                                WHITE
                                                   LOAD         BLACK
                                                                                                         BLUE
                                                                                                         BLACK
                                                                RED
                                                                             TRP-D
                                                                                                         RED
                                                                RED
                                                                                         LOW VOLTAGE
                                                                                         3 CONDUCTOR 22GA CLASS 2 WIRING
To control what time of day the occupancy sensor is in
operation determined by a TORK digital or mechani-
                                                                                                                                  BLACK
                                                                                                                                          BLUE
                                                                                                                            RED
cal time switch. TRP-D can be mounted close to load
and sensor can be installed up to 500’ away using
#22 AWG low voltage wire. TORK digital or mechan-                                        OSC5U / OSC10U / OSC20U
                                                                                       OSCW5P / OSCW15P / OSC20UP
ical time switch can be installed anywhere between                                          OCCUPANCY SENSOR
the TRP-D and sensor.
                  N
                          120 OR 277 VAC
                   L
                                                                      LOAD
                             TORK OCCUPANCY SENSOR
22
                                                                                                                      APPLICATIONS GUIDE
                       OR
                                                                        GROUND
          TORK ELECTRONIC INTERVAL TIMER                                                               BLACK             RED
                     SSA100                                                                                                         LOAD
                     SSA200                                                                                              GREEN
GROUND
                                                       3-WAY                             3-WAY
                                                     WALL SWITCH                       WALL SWITCH
                                                                                                      BLACK WIRE
                                                                                                      NOT USED
                                                                                                                      BLACK
RED
                                       N               WHITE
                                                       BLACK
                                       L
                                                                        TRP-D
                                                       RED
                                                                                                       LOW VOLTAGE WIRING
                                                       RED                                             MINIMUM 22AWG
NOVEMBER 2008                                                                                                                              23
                                                        A DIVISION OF           NSi INDUSTRIES, LLC
                               NOTES