RT Request-932-14-10-2023

This document is a request for non-destructive testing (NDT) for welding jobs on various pipelines at Occidental of Oman. It details 8 welds to be tested, including replacing leak sections of 4-inch flowlines for two commingled wells, replacing a road crossing for another well, and welds on a pipeline for a water injection terminal. The document provides information on the material, weld numbers, joint types, welding procedures, and NDT required for each weld.

Uploaded by

gopalnaik817
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views1 page

RT Request-932-14-10-2023

This document is a request for non-destructive testing (NDT) for welding jobs on various pipelines at Occidental of Oman. It details 8 welds to be tested, including replacing leak sections of 4-inch flowlines for two commingled wells, replacing a road crossing for another well, and welds on a pipeline for a water injection terminal. The document provides information on the material, weld numbers, joint types, welding procedures, and NDT required for each weld.

Uploaded by

gopalnaik817
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Najed Al Ahliya

Request for NDT

Company : Occidental of Oman, Inc. Contractor :Najed Al Ahliya

Project : Maintenance & Operation Services Contract No : 24000083686 Applicable Code : REFER BELOW

Job Title RT Request no : NAA/RT/WL/0930 Sheet : 01/01


Welder ID PT MT
Material Size /
S/NO Drawing No Material Weld No. Joint Type WPS # Process Cut Cut RT PT Remarks
Sch. Root/Hot Fillup /CAP Weld Weld
edge edge

REPLACE 4"FLOWLINE LEAK SECTION FOR JHL-W05 & JHL-W08 GL (COMMINGLE WELLS) NEAR WL OLD FACILITY MANIFOLD
10746201
1 4 x sch 40 CS GWT-01 WD- FLANGE-PIPE NAA/WPS/001A SMAW YES YES 31.4
JHL-W05 & 08
10746201
2 4 x sch 40 CS GWT-02 WD- FLANGE-PIPE NAA/WPS/001A SMAW YES YES
JHL-W05 & 08

REPLACE 4"FLOWLINE LEAK ROAD CROSSING (RDX) FOR RYN-020 NEAR RAYYAN REMOTE EAST MANIFOLD

10746335
1 4 x sch 40 CS FW-22 WD-22 PIPE-BEND NAA/WPS/001A SMAW YES 31.4
RYN-020
10746335
2 4 x sch 40 CS FW- WD-22 NAA/WPS/001A SMAW YES 31.4
RYN-020

WQT

TULASAYYA
NAA/WPS/001A
1 REDDY 4 x sch 40 CS WD-032 PIPE-PIPE SMAW YES 31.4
REV-02
(WQT-1)
DINESH NAA/WPS/001A
2 4 x sch 40 CS WD-033 PIPE-PIPE SMAW YES 31.4
(WQT-1) REV-02

For NDT Crew For Company

Date Received: 14-10-23 Signature:

Signature: Name & Designation: NAGARAJAN / QC INSPECTOR

Name & Designation: MULAYAM / NDT TECHNICIAN Date: 14-10-2023


Document Control Tag: Revision: 0 Issue Date: 11.09.2019